Lars-Åke Brodin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lars-Åke Brodin has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Reidar Winter
Department of Clinical Physiology, Karolinska University Hospital Huddinge, Stockholm, Sweden
7 shared publications - Jacek Nowak
Department of Clinical Physiology, Karolinska University Hospital in Huddinge, Stockholm, Sweden
5 shared publications - Kambiz Shahgaldi
Department of Cardiology, Karolinska University Hospital, Huddinge, Stockholm, Sweden
5 shared publications - Aristomenis Manouras
Department of Medicine, Karolinska Institutet, Stockholm, Sweden
4 shared publications - Petri Gudmundsson
Department of Biomedical Laboratory Science, Malmö University, Malmö, Sweden
2 shared publications - Anna Abrahamsson
Department of Clinical Physiology, Karolinska University Hospital Huddinge, Stockholm, Sweden
1 shared publication
Latest Publications
- Open Access
- 5 October 2010
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 8 (1) , 45
Three-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation
Three dimensional echocardiography (3DE) approaches the accuracy of cardiac magnetic resonance in measuring left ventricular (LV) volumes and ejection fraction (EF). The multibeat modality in comparison to single-beat (SB) requires breath-hold technique and regular heart rhythm which could limit the use of this technique in patients with atrial fibrillation (AF) due to stitching artifact. The study aimed to investigate whether SB full volume 3DE acquisition reduces inter- and intraobserver variability in assessment of LV volumes and EF in comparison to four-beat (4B) ECG-gated full volume 3DE recording in patients with AF.
- 5 October 2010
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 8 (1) , 45
Open AccessThree-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation
Three dimensional echocardiography (3DE) approaches the accuracy of cardiac magnetic resonance in measuring left ventricular (LV) volumes and ejection fraction (EF). The multibeat modality in comparison to single-beat (SB) requires breath-hold technique and regular heart rhythm which could limit the use of this technique in patients with atrial fibrillation (AF) due to stitching artifact. The study aimed to investigate whether SB full volume 3DE acquisition reduces inter- and intraobserver variability in assessment of LV volumes and EF in comparison to four-beat (4B) ECG-gated full volume 3DE recording in patients with AF.
- Open Access
- 25 August 2009
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 7 (1) , 41
Visually estimated ejection fraction by two dimensional and triplane echocardiography is closely correlated with quantitative ejection fraction by real-time three dimensional echocardiography
Visual assessment of left ventricular ejection fraction (LVEF) is often used in clinical routine despite general recommendations to use quantitative biplane Simpsons (BPS) measurements. Even thou quantitative methods are well validated and from many reasons preferable, the feasibility of visual assessment (eyeballing) is superior. There is to date only sparse data comparing visual EF assessment in comparison to quantitative methods available. The aim of this study was to compare visual EF assessment by two-dimensional echocardiography (2DE) and triplane echocardiography (TPE) using quantitative real-time three-dimensional echocardiography (RT3DE) as the reference method.
- 25 August 2009
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 7 (1) , 41
Open AccessVisually estimated ejection fraction by two dimensional and triplane echocardiography is closely correlated with quantitative ejection fraction by real-time three dimensional echocardiography
Visual assessment of left ventricular ejection fraction (LVEF) is often used in clinical routine despite general recommendations to use quantitative biplane Simpsons (BPS) measurements. Even thou quantitative methods are well validated and from many reasons preferable, the feasibility of visual assessment (eyeballing) is superior. There is to date only sparse data comparing visual EF assessment in comparison to quantitative methods available. The aim of this study was to compare visual EF assessment by two-dimensional echocardiography (2DE) and triplane echocardiography (TPE) using quantitative real-time three-dimensional echocardiography (RT3DE) as the reference method.
- Open Access
- 23 June 2009
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 7 (1) , 29
Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible?
Tissue Doppler (TD) in pulsed mode (spectral TD) and colour TD are the two modalities today available in tissue velocity echocardiography (TVE). Previous studies have shown poor agreement between these two methods when measuring myocardial velocities and displacement. In this study, the concordance between the myocardial velocity and displacement measurements using colour TD and different spectral TD procedures was evaluated.
- 23 June 2009
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 7 (1) , 29
Open AccessAre measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible?
Tissue Doppler (TD) in pulsed mode (spectral TD) and colour TD are the two modalities today available in tissue velocity echocardiography (TVE). Previous studies have shown poor agreement between these two methods when measuring myocardial velocities and displacement. In this study, the concordance between the myocardial velocity and displacement measurements using colour TD and different spectral TD procedures was evaluated.
- Open Access
- 17 March 2009
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 7 (1) , 12
Measurements of left ventricular myocardial longitudinal systolic displacement using spectral and colour tissue Doppler: time for a reassessment?
Echocardiographic measurements of left ventricular (LV) myocardial displacement may produce different results depending on the choice of employed modality and subjective adjustments during data acquisition and analysis.
- 17 March 2009
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 7 (1) , 12
Open AccessMeasurements of left ventricular myocardial longitudinal systolic displacement using spectral and colour tissue Doppler: time for a reassessment?
Echocardiographic measurements of left ventricular (LV) myocardial displacement may produce different results depending on the choice of employed modality and subjective adjustments during data acquisition and analysis.
- Open Access
- 5 August 2008
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 6 (1) , 39
Cardiac incoordination induced by left bundle branch block: its relation with left ventricular systolic function in patients with and without cardiomyopathy
Although left bundle branch block (LBBB) alters the electrical activation of the heart, it is unknown how it might change the process of myocardial coordination (MC) and how it may affect the left ventricular (LV) systolic function. The present study assessed the effects of LBBB on MC in patients with LBBB with and without dilated (DCMP) or ischemic cardiomyopathy (ICMP).
- 5 August 2008
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 6 (1) , 39
Open AccessCardiac incoordination induced by left bundle branch block: its relation with left ventricular systolic function in patients with and without cardiomyopathy
Although left bundle branch block (LBBB) alters the electrical activation of the heart, it is unknown how it might change the process of myocardial coordination (MC) and how it may affect the left ventricular (LV) systolic function. The present study assessed the effects of LBBB on MC in patients with LBBB with and without dilated (DCMP) or ischemic cardiomyopathy (ICMP).
- Open Access
- 4 June 2008
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 6 (1) , 26
Assessment of left ventricular volumes using simplified 3-D echocardiography and computed tomography – a phantom and clinical study
To compare the accuracy of simplified 3-dimensional (3-D) echocardiography vs. multi-slice computed tomography (MSCT) software for the quantification of left ventricular (LV) volumes. Three-D echocardiography (3-planes approach) and MSCT-CardIQ software were calibrated by measuring known volumes of 10 phantoms designed to closely mimic blood-endocardium interface. Subsequently, LV volumes were measured with both the methods in 9 patients referred routinely for coronary angiography and the agreement between the measurements was evaluated. Simplified 3D-echocardiography provided higher degree of agreement between the measured and true phantom volumes (mean difference 0 +/- 1 ml, variation range +4 to -4 ml) than MSCT software (mean difference 6 +/- 5 ml; variation range +22 to -10 ml). The agreement between LV measurements in the patients was considerably poorer, with significantly larger volumes produced by MSCT (mean difference -23 +/- 40 ml, variation between +93 and -138 ml). Simplified 3-D echocardiography provides more accurate assessment of phantom volumes than MSCT-CardIQ software. The discrepancy between the results of LV measurements with the two methods is even greater and does not warrant their interchangeable diagnostic use.
- 4 June 2008
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 6 (1) , 26
Open AccessAssessment of left ventricular volumes using simplified 3-D echocardiography and computed tomography – a phantom and clinical study
To compare the accuracy of simplified 3-dimensional (3-D) echocardiography vs. multi-slice computed tomography (MSCT) software for the quantification of left ventricular (LV) volumes. Three-D echocardiography (3-planes approach) and MSCT-CardIQ software were calibrated by measuring known volumes of 10 phantoms designed to closely mimic blood-endocardium interface. Subsequently, LV volumes were measured with both the methods in 9 patients referred routinely for coronary angiography and the agreement between the measurements was evaluated. Simplified 3D-echocardiography provided higher degree of agreement between the measured and true phantom volumes (mean difference 0 +/- 1 ml, variation range +4 to -4 ml) than MSCT software (mean difference 6 +/- 5 ml; variation range +22 to -10 ml). The agreement between LV measurements in the patients was considerably poorer, with significantly larger volumes produced by MSCT (mean difference -23 +/- 40 ml, variation between +93 and -138 ml). Simplified 3-D echocardiography provides more accurate assessment of phantom volumes than MSCT-CardIQ software. The discrepancy between the results of LV measurements with the two methods is even greater and does not warrant their interchangeable diagnostic use.
- Open Access
- 4 April 2008
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 6 (1) , 13
Flow-volume loops derived from three-dimensional echocardiography: a novel approach to the assessment of left ventricular hemodynamics
This study explores the feasibility of non-invasive evaluation of left ventricular (LV) flow-volume dynamics using 3-dimensional (3D) echocardiography, and the capacity of such an approach to identify altered LV hemodynamic states caused by valvular abnormalities.
- 4 April 2008
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 6 (1) , 13
Open AccessFlow-volume loops derived from three-dimensional echocardiography: a novel approach to the assessment of left ventricular hemodynamics
This study explores the feasibility of non-invasive evaluation of left ventricular (LV) flow-volume dynamics using 3-dimensional (3D) echocardiography, and the capacity of such an approach to identify altered LV hemodynamic states caused by valvular abnormalities.
- Open Access
- 31 October 2006
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 4 (1) , 40
Feasibility of creating estimates of left ventricular flow-volume dynamics using echocardiography
This study explores the feasibility of non-invasive assessment of left ventricular volume and flow relationship throughout cardiac cycle employing echocardiographic methods. Nine healthy individuals and 3 patients with severe left-sided valvular abnormalities were subject to resting echocardiography with automated endocardial border detection allowing real-time estimation of left ventricular volume throughout the cardiac cycle. Global and regional (6 different left ventricular segments) estimates of flow-volume loops were subsequently constructed by plotting acquired instantaneous left ventricular 2-D area data (left ventricular volume) vs. their first derivatives (flow). Flow-volume loop estimates were obtainable in 75% of all echocardiographic images and displayed in normal individuals some regional morphological variation with more pronounced isovolumic events in the paraseptal segments and significantly delayed maximal systolic flow paraapically. In patients with aortic stenosis, maximal systolic flow occurred at a lower estimated left ventricular systolic volume whereas in mitral stenosis, maximal diastolic flow was observed at a higher estimated left ventricular diastolic volume. Aortic regurgitation caused a complex alteration of the estimated flow-volume loop shape during diastole. Non-invasive assessment of left ventricular flow-volume relationship with echocardiography is technically feasible and reveals the existence of regional variation in flow-volume loop morphology. Valvular abnormalities cause a clear and specific alteration of the estimates of the normal systolic or diastolic flow-volume pattern, likely reflecting the underlying pathophysiology.
- 31 October 2006
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 4 (1) , 40
Open AccessFeasibility of creating estimates of left ventricular flow-volume dynamics using echocardiography
This study explores the feasibility of non-invasive assessment of left ventricular volume and flow relationship throughout cardiac cycle employing echocardiographic methods. Nine healthy individuals and 3 patients with severe left-sided valvular abnormalities were subject to resting echocardiography with automated endocardial border detection allowing real-time estimation of left ventricular volume throughout the cardiac cycle. Global and regional (6 different left ventricular segments) estimates of flow-volume loops were subsequently constructed by plotting acquired instantaneous left ventricular 2-D area data (left ventricular volume) vs. their first derivatives (flow). Flow-volume loop estimates were obtainable in 75% of all echocardiographic images and displayed in normal individuals some regional morphological variation with more pronounced isovolumic events in the paraseptal segments and significantly delayed maximal systolic flow paraapically. In patients with aortic stenosis, maximal systolic flow occurred at a lower estimated left ventricular systolic volume whereas in mitral stenosis, maximal diastolic flow was observed at a higher estimated left ventricular diastolic volume. Aortic regurgitation caused a complex alteration of the estimated flow-volume loop shape during diastole. Non-invasive assessment of left ventricular flow-volume relationship with echocardiography is technically feasible and reveals the existence of regional variation in flow-volume loop morphology. Valvular abnormalities cause a clear and specific alteration of the estimates of the normal systolic or diastolic flow-volume pattern, likely reflecting the underlying pathophysiology.