Estefanía M Olmos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Estefanía M Olmos has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Abraham Otero
Department of Information Technologies, Institute of Technology, Universidad San Pablo-CEU, CEU Universities, Campus Montepríncipe, 28660, Boadilla del Monte, Spain
1 shared publication - Carlos Oscar Sanchez Sorzano
Centro Nacional de Biotecnologia, Consejo Superior de Investigaciones Cientificas
1 shared publication - Jose Maria Carazo
Centro Nacional de Biotecnología (CNB-CSIC), Madrid, Spain
1 shared publication
Latest Publications
- Open Access
- 1 January 2009
- Published by Springer Nature in BMC Structural Biology
- Vol. 9 (1) , 18
Error analysis in the determination of the electron microscopical contrast transfer function parameters from experimental power Spectra
The transmission electron microscope is used to acquire structural information of macromolecular complexes. However, as any other imaging device, it introduces optical aberrations that must be corrected if high-resolution structural information is to be obtained. The set of all aberrations are usually modeled in Fourier space by the so-called Contrast Transfer Function (CTF). Before correcting for the CTF, we must first estimate it from the electron micrographs. This is usually done by estimating a number of parameters specifying a theoretical model of the CTF. This estimation is performed by minimizing some error measure between the theoretical Power Spectrum Density (PSD) and the experimentally observed PSD. The high noise present in the micrographs, the possible local minima of the error function for estimating the CTF parameters, and the cross-talking between CTF parameters may cause errors in the estimated CTF parameters.
- 1 January 2009
- Published by Springer Nature in BMC Structural Biology
- Vol. 9 (1) , 18
Open AccessError analysis in the determination of the electron microscopical contrast transfer function parameters from experimental power Spectra
The transmission electron microscope is used to acquire structural information of macromolecular complexes. However, as any other imaging device, it introduces optical aberrations that must be corrected if high-resolution structural information is to be obtained. The set of all aberrations are usually modeled in Fourier space by the so-called Contrast Transfer Function (CTF). Before correcting for the CTF, we must first estimate it from the electron micrographs. This is usually done by estimating a number of parameters specifying a theoretical model of the CTF. This estimation is performed by minimizing some error measure between the theoretical Power Spectrum Density (PSD) and the experimentally observed PSD. The high noise present in the micrographs, the possible local minima of the error function for estimating the CTF parameters, and the cross-talking between CTF parameters may cause errors in the estimated CTF parameters.