Saeb F Khoury
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Saeb F Khoury has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Koustubh D Ashtekar
Department of Mechanical, Industrial and Nuclear Engineering, 601B Rhodes Hall, University of Cincinnati, Clifton Avenue, Cincinnati, OH, USA
1 shared publication - Lloyd H Back
Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA, USA
1 shared publication - Mohamed Effat
Division of Cardiovascular Health and Disease, University of Cincinnati College of Medicine, Cincinnati OH, USA
1 shared publication - Rupak Kumar Banerjee
Department of Biomedical Engineering, University of Cincinnati, Veterans Affairs Medical Center, Cincinnati, OH, USA
1 shared publication - Tarek Helmy
Department of Internal Med-Cardiology, MSB, University of Cincinnati, Cincinnati, OH, USA
1 shared publication
Latest Publications
- Open Access
- 1 January 2008
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 7 (1) , 24
Hemodynamic diagnostics of epicardial coronary stenoses: in-vitro experimental and computational study
The severity of epicardial coronary stenosis can be assessed by invasive measurements of trans-stenotic pressure drop and flow. A pressure or flow sensor-tipped guidewire inserted across the coronary stenosis causes an overestimation in true trans-stenotic pressure drop and reduction in coronary flow. This may mask the true severity of coronary stenosis. In order to unmask the true severity of epicardial stenosis, we evaluate a diagnostic parameter, which is obtained from fundamental fluid dynamics principles. This experimental and numerical study focuses on the characterization of the diagnostic parameter, pressure drop coefficient, and also evaluates the pressure recovery downstream of stenoses. Three models of coronary stenosis namely, moderate, intermediate and severe stenosis, were manufactured and tested in the in-vitro set-up simulating the epicardial coronary network. The trans-stenotic pressure drop and flow distal to stenosis models were measured by non-invasive method, using external pressure and flow sensors, and by invasive method, following guidewire insertion across the stenosis. The viscous and momentum-change components of the pressure drop for various flow rates were evaluated from quadratic relation between pressure drop and flow. Finally, the pressure drop coefficient (CDPe) was calculated as the ratio of pressure drop and distal dynamic pressure. The pressure recovery factor (η) was calculated as the ratio of pressure recovery coefficient and the area blockage. The mean pressure drop-flow characteristics before and during guidewire insertion indicated that increasing stenosis causes a shift in dominance from viscous pressure to momentum forces. However, for intermediate (~80%) area stenosis, which is between moderate (~65%) and severe (~90%) area stenoses, both losses were similar in magnitude. Therefore, guidewire insertion plays a critical role in evaluating the hemodynamic severity of coronary stenosis. More importantly, mean CDPe increased (17 ± 3.3 to 287 ± 52, n = 3, p < 0.01) and mean η decreased (0.54 ± 0.04 to 0.37 ± 0.05, p < 0.01) from moderate to severe stenosis during guidewire insertion. The wide range of CDPe is not affected that much by the presence of guidewire. CDPe can be used in clinical practice to evaluate the true severity of coronary stenosis due to its significant difference between values measured at moderate and severe stenoses.
- 1 January 2008
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 7 (1) , 24
Open AccessHemodynamic diagnostics of epicardial coronary stenoses: in-vitro experimental and computational study
The severity of epicardial coronary stenosis can be assessed by invasive measurements of trans-stenotic pressure drop and flow. A pressure or flow sensor-tipped guidewire inserted across the coronary stenosis causes an overestimation in true trans-stenotic pressure drop and reduction in coronary flow. This may mask the true severity of coronary stenosis. In order to unmask the true severity of epicardial stenosis, we evaluate a diagnostic parameter, which is obtained from fundamental fluid dynamics principles. This experimental and numerical study focuses on the characterization of the diagnostic parameter, pressure drop coefficient, and also evaluates the pressure recovery downstream of stenoses. Three models of coronary stenosis namely, moderate, intermediate and severe stenosis, were manufactured and tested in the in-vitro set-up simulating the epicardial coronary network. The trans-stenotic pressure drop and flow distal to stenosis models were measured by non-invasive method, using external pressure and flow sensors, and by invasive method, following guidewire insertion across the stenosis. The viscous and momentum-change components of the pressure drop for various flow rates were evaluated from quadratic relation between pressure drop and flow. Finally, the pressure drop coefficient (CDPe) was calculated as the ratio of pressure drop and distal dynamic pressure. The pressure recovery factor (η) was calculated as the ratio of pressure recovery coefficient and the area blockage. The mean pressure drop-flow characteristics before and during guidewire insertion indicated that increasing stenosis causes a shift in dominance from viscous pressure to momentum forces. However, for intermediate (~80%) area stenosis, which is between moderate (~65%) and severe (~90%) area stenoses, both losses were similar in magnitude. Therefore, guidewire insertion plays a critical role in evaluating the hemodynamic severity of coronary stenosis. More importantly, mean CDPe increased (17 ± 3.3 to 287 ± 52, n = 3, p < 0.01) and mean η decreased (0.54 ± 0.04 to 0.37 ± 0.05, p < 0.01) from moderate to severe stenosis during guidewire insertion. The wide range of CDPe is not affected that much by the presence of guidewire. CDPe can be used in clinical practice to evaluate the true severity of coronary stenosis due to its significant difference between values measured at moderate and severe stenoses.