Mark Bowers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mark Bowers has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Leanne Harmann
Department of Medicine, Division of Cardiovascular Medicine, Medical College of Wisconsin, Milwaukee WI 53226, USA
2 shared publications - John F LaDisa
Department of Medicine, Marquette University, 1120 W. Wisconsin Avenue, Wilwaukee, WI 53233, USA
1 shared publication - Ramin Artang
Division of Cardiovascular Medicine, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
1 shared publication - Raymond Q. Migrino
Phoenix VA and U Arizona Coll Med-Phoenix, Phoenix, AZ
1 shared publication - Raymond Q. Migrino
Office of Research, Phoenix Veterans Affairs Health Care System, Phoenix, Arizona
1 shared publication - Robert W. Prost
Departments of Radiology and Biophysics, Medical College of Wisconsin, Milwaukee, WI 53226 USA
1 shared publication
Latest Publications
- Open Access
- 1 January 2011
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 13 (1) , 37
Carotid plaque regression following 6-month statin therapy assessed by 3T cardiovascular magnetic resonance: comparison with ultrasound intima media thickness
- 1 January 2011
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 13 (1) , 37
Open AccessCarotid plaque regression following 6-month statin therapy assessed by 3T cardiovascular magnetic resonance: comparison with ultrasound intima media thickness
- Open Access
- 31 March 2009
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 7 (1) , 16
Left atrial volume measurement with automated border detection by 3-dimensional echocardiography: comparison with magnetic resonance imaging
Left atrial size is an important marker for adverse cardiovascular events. There is general consensus that left atrial volume index (LAVI) is the best measurement of size. The current LAVI measurement techniques are laborious. Semi-automated measurement with a 3-dimensional echocardiography (3DE) system may be a practical clinical alternative to measure LAVI, but it has not been adequately evaluated against Magnetic Resonance Imaging (MRI) gold standard. The aim of this study was to compare the accuracy of a commercially available 3D algorithm for measurement of LAVI against LAVI obtained from MRI and Area Length Method (ALM). In 27 consecutive subjects referred for cardiac MRI (age 54 +/- 13 years, 63% male), LAVI was measured using 3 imaging modalities: 3DE, ALM, MRI and the results were correlated. ALM was measured using standard American Society of Echocardiography guidelines. The time required to measure LAVI by 3DE and ALM were compared. There was a significant correlation in systolic and diastolic LA volumes and left atrial ejection fraction between 3DE and MRI (r = 0.86 for systole, r = 0.76 for diastole, r = 0.88 for ejection fraction, P < 0.0001 for all). There was also significant correlation of diastolic volumes between 3DE and ALM (r = 0.77, P < 0.0001). The time to obtain LAVI was shorter using 3DE versus ALM (56 +/- 8 vs 135 +/- 55 seconds, P < 0.0001). Three-dimensional echocardiography with semiautomatic border detection is a practical alternative for obtaining the left atrial volume in a time-efficient manner compared to the current standard.
- 31 March 2009
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 7 (1) , 16
Open AccessLeft atrial volume measurement with automated border detection by 3-dimensional echocardiography: comparison with magnetic resonance imaging
Left atrial size is an important marker for adverse cardiovascular events. There is general consensus that left atrial volume index (LAVI) is the best measurement of size. The current LAVI measurement techniques are laborious. Semi-automated measurement with a 3-dimensional echocardiography (3DE) system may be a practical clinical alternative to measure LAVI, but it has not been adequately evaluated against Magnetic Resonance Imaging (MRI) gold standard. The aim of this study was to compare the accuracy of a commercially available 3D algorithm for measurement of LAVI against LAVI obtained from MRI and Area Length Method (ALM). In 27 consecutive subjects referred for cardiac MRI (age 54 +/- 13 years, 63% male), LAVI was measured using 3 imaging modalities: 3DE, ALM, MRI and the results were correlated. ALM was measured using standard American Society of Echocardiography guidelines. The time required to measure LAVI by 3DE and ALM were compared. There was a significant correlation in systolic and diastolic LA volumes and left atrial ejection fraction between 3DE and MRI (r = 0.86 for systole, r = 0.76 for diastole, r = 0.88 for ejection fraction, P < 0.0001 for all). There was also significant correlation of diastolic volumes between 3DE and ALM (r = 0.77, P < 0.0001). The time to obtain LAVI was shorter using 3DE versus ALM (56 +/- 8 vs 135 +/- 55 seconds, P < 0.0001). Three-dimensional echocardiography with semiautomatic border detection is a practical alternative for obtaining the left atrial volume in a time-efficient manner compared to the current standard.