Carmen Llacer Moscardo
Research Subjects
Research Interests
Carmen Llacer Moscardo has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Claire Lemanski
Département de Cancérologie Radiothérapie et de Radiophysique, CRLC Val d'Aurelle-Paul Lamarque, Montpellier, France
2 shared publications - David Azria
Département de Cancérologie Radiothérapie et de Radiophysique, CRLC Val d'Aurelle-Paul Lamarque, Montpellier, France
2 shared publications - Jean-Bernard Dubois
Département de Cancérologie Radiothérapie et de Radiophysique, CRLC Val d'Aurelle-Paul Lamarque, Montpellier, France
2 shared publications - Norbert Aillères
Département de Cancérologie Radiothérapie et de Radiophysique, CRLC Val d'Aurelle-Paul Lamarque, Montpellier, France
2 shared publications - Pascal Fenoglietto
Département de Cancérologie Radiothérapie et de Radiophysique, CRLC Val d'Aurelle-Paul Lamarque, Montpellier, France
2 shared publications - Sophie Gourgou
Unité de Biostatistiques, CRLC Val d'Aurelle-Paul Lamarque, Montpellier, France
2 shared publications
Latest Publications
- Open Access
- 13 October 2010
- Published by Springer Nature in Radiation Oncology
- Vol. 5 (1) , 92
Plan comparison of volumetric-modulated arc therapy (RapidArc) and conventional intensity-modulated radiation therapy (IMRT) in anal canal cancer
Background: To compare volumetric-modulated arc therapy (RapidArc) plans with conventional intensity-modulated radiation therapy (IMRT) plans in anal canal cancers. Methods: Ten patients with anal canal carcinoma previously treated with IMRT in our institution were selected for this study. For each patient, three plans were generated with the planning CT scan: one using a fixed beam IMRT, and two plans using the RapidArc technique: a single (RA1) and a double (RA2) modulated arc therapy. The treatment plan was designed to deliver in one process with simultaneous integrated boost (SIB) a dose of 59.4 Gy to the planning target volume (PTV2) based on the gross disease in a 1.8 Gy-daily fraction, 5 days a week. At the same time, the subclinical disease (PTV1) was planned to receive 49.5 Gy in a 1.5 Gy-daily fraction. Plans were normalized to 99% of the PTV2 that received 95% of the prescribed dose. Planning objectives were 95% of the PTV1 will receive 95% of the prescribed dose and no more than 2% of the PTV will receive more than 107%. Dose-volume histograms (DVH) for the target volume and the organs at risk (bowel tract, bladder, iliac crests, femoral heads, genitalia/perineum, and healthy tissue) were compared for these different techniques. Monitor units (MU) and delivery treatment time were also reported. Results: All plans achieved fulfilled objectives. Both IMRT and RA2 resulted in superior coverage of PTV than RA1 that was slightly inferior for conformity and homogeneity (p < 0.05). Conformity index (CI95%) for the PTV2 was 1.15 ± 0.15 (RA2), 1.28 ± 0.22 (IMRT), and 1.79 ± 0.5 (RA1). Homogeneity (D5% - D95%) for PTV2 was 3.21 ± 1.16 Gy (RA2), 2.98 ± 0.7 Gy (IMRT), and 4.3 ± 1.3 Gy (RA1). RapidArc showed to be superior to IMRT in terms of organ at risk sparing. For bowel tract, the mean dose was reduced of 4 Gy by RA2 compared to IMRT. Similar trends were observed for bladder, femoral heads, and genitalia. The DVH of iliac crests and healthy tissue resulted in comparable sparing for the low doses (V10 and V20). Compared to IMRT, mean MUs for each fraction was significantly reduced with RapidArc (p = 0.0002) and the treatment time was reduced by a 6-fold extent. Conclusion: For patients suffering from anal canal cancer, RapidArc with 2 arcs was able to deliver equivalent treatment plan to IMRT in terms of PTV coverage. It provided a better organ at risk sparing and significant reductions of MU and treatment time per fraction.
- 13 October 2010
- Published by Springer Nature in Radiation Oncology
- Vol. 5 (1) , 92
Open AccessPlan comparison of volumetric-modulated arc therapy (RapidArc) and conventional intensity-modulated radiation therapy (IMRT) in anal canal cancer
Background: To compare volumetric-modulated arc therapy (RapidArc) plans with conventional intensity-modulated radiation therapy (IMRT) plans in anal canal cancers. Methods: Ten patients with anal canal carcinoma previously treated with IMRT in our institution were selected for this study. For each patient, three plans were generated with the planning CT scan: one using a fixed beam IMRT, and two plans using the RapidArc technique: a single (RA1) and a double (RA2) modulated arc therapy. The treatment plan was designed to deliver in one process with simultaneous integrated boost (SIB) a dose of 59.4 Gy to the planning target volume (PTV2) based on the gross disease in a 1.8 Gy-daily fraction, 5 days a week. At the same time, the subclinical disease (PTV1) was planned to receive 49.5 Gy in a 1.5 Gy-daily fraction. Plans were normalized to 99% of the PTV2 that received 95% of the prescribed dose. Planning objectives were 95% of the PTV1 will receive 95% of the prescribed dose and no more than 2% of the PTV will receive more than 107%. Dose-volume histograms (DVH) for the target volume and the organs at risk (bowel tract, bladder, iliac crests, femoral heads, genitalia/perineum, and healthy tissue) were compared for these different techniques. Monitor units (MU) and delivery treatment time were also reported. Results: All plans achieved fulfilled objectives. Both IMRT and RA2 resulted in superior coverage of PTV than RA1 that was slightly inferior for conformity and homogeneity (p < 0.05). Conformity index (CI95%) for the PTV2 was 1.15 ± 0.15 (RA2), 1.28 ± 0.22 (IMRT), and 1.79 ± 0.5 (RA1). Homogeneity (D5% - D95%) for PTV2 was 3.21 ± 1.16 Gy (RA2), 2.98 ± 0.7 Gy (IMRT), and 4.3 ± 1.3 Gy (RA1). RapidArc showed to be superior to IMRT in terms of organ at risk sparing. For bowel tract, the mean dose was reduced of 4 Gy by RA2 compared to IMRT. Similar trends were observed for bladder, femoral heads, and genitalia. The DVH of iliac crests and healthy tissue resulted in comparable sparing for the low doses (V10 and V20). Compared to IMRT, mean MUs for each fraction was significantly reduced with RapidArc (p = 0.0002) and the treatment time was reduced by a 6-fold extent. Conclusion: For patients suffering from anal canal cancer, RapidArc with 2 arcs was able to deliver equivalent treatment plan to IMRT in terms of PTV coverage. It provided a better organ at risk sparing and significant reductions of MU and treatment time per fraction.
- Open Access
- 20 September 2010
- Published by Springer Nature in Radiation Oncology
- Vol. 5 (1) , 83
Feasibility study of volumetric modulated arc therapy for the treatment of retroperitoneal sarcomas
Radiotherapy for retroperitoneal sarcomas remains controversial and a technical challenge considering the threshold of contiguous critical organs tolerance. We performed consecutive RapidArc dosimetric plans in preoperative or postoperative setting.
- 20 September 2010
- Published by Springer Nature in Radiation Oncology
- Vol. 5 (1) , 83
Open AccessFeasibility study of volumetric modulated arc therapy for the treatment of retroperitoneal sarcomas
Radiotherapy for retroperitoneal sarcomas remains controversial and a technical challenge considering the threshold of contiguous critical organs tolerance. We performed consecutive RapidArc dosimetric plans in preoperative or postoperative setting.
- Open Access
- 1 December 2007
- Published by Springer Nature in Radiation Oncology
- Vol. 2 (1) , 41
Optimal organ-sparing intensity-modulated radiation therapy (IMRT) regimen for the treatment of locally advanced anal canal carcinoma: a comparison of conventional and IMRT plans
Background: To compare the dosimetric advantage of three different intensity-modulated radiation therapy (IMRT) plans to a three dimensional (3D) conventional radiation treatment for anal cancer with regards to organs-at-risk (OAR) avoidance, including iliac bone marrow. Methods: Five patients with T1-3 N0-1 anal cancer and five with T4 and/or N2-3 tumors were selected. Clinical tumor volume (CTV) included tumor, anal canal and inguinal, peri-rectal, and internal/external iliac nodes (plus pre-sacral nodes for T4/N2-3 tumors). Four plans were generated: (A) AP/PA with 3D conformal boost, (B) pelvic IMRT with conformal boost (C) pelvic IMRT with IMRT boost and (D) IMRT with simultaneous integrated boost (SIB). The dose for plans (A) to (C) was 45 Gy/25 followed by a 14.4 Gy/8 boost, and the total dose for plan (D) (SIB) was 59.4 Gy/33. Coverage of both PTV and the volume of OAR (small bowel, genitalia, iliac crest and femoral heads) receiving more than 10, 20, 30, and 40 Gy (V10, V20, V30, V40) were compared using non parametric statistics. Results: Compared to plan (A), IMRT plans (B) to (D) significantly reduced the V30 and V40 of small bowel, bladder and genitalia for all patients. The V10 and V20 of iliac crests were similar for the N0-1 group but were significantly reduced with IMRT for the N2-3/T4 group (V20 for A = 50.2% compared to B = 33%, C = 32.8%, D = 34.3%). There was no statistical difference between 2-phase (arm C) and single-phase (SIB, arm D) IMRT plans. Conclusion: IMRT is superior to 3D conformal radiation treatment for anal carcinoma with respect to OAR sparing, including bone marrow sparing.
- 1 December 2007
- Published by Springer Nature in Radiation Oncology
- Vol. 2 (1) , 41
Open AccessOptimal organ-sparing intensity-modulated radiation therapy (IMRT) regimen for the treatment of locally advanced anal canal carcinoma: a comparison of conventional and IMRT plans
Background: To compare the dosimetric advantage of three different intensity-modulated radiation therapy (IMRT) plans to a three dimensional (3D) conventional radiation treatment for anal cancer with regards to organs-at-risk (OAR) avoidance, including iliac bone marrow. Methods: Five patients with T1-3 N0-1 anal cancer and five with T4 and/or N2-3 tumors were selected. Clinical tumor volume (CTV) included tumor, anal canal and inguinal, peri-rectal, and internal/external iliac nodes (plus pre-sacral nodes for T4/N2-3 tumors). Four plans were generated: (A) AP/PA with 3D conformal boost, (B) pelvic IMRT with conformal boost (C) pelvic IMRT with IMRT boost and (D) IMRT with simultaneous integrated boost (SIB). The dose for plans (A) to (C) was 45 Gy/25 followed by a 14.4 Gy/8 boost, and the total dose for plan (D) (SIB) was 59.4 Gy/33. Coverage of both PTV and the volume of OAR (small bowel, genitalia, iliac crest and femoral heads) receiving more than 10, 20, 30, and 40 Gy (V10, V20, V30, V40) were compared using non parametric statistics. Results: Compared to plan (A), IMRT plans (B) to (D) significantly reduced the V30 and V40 of small bowel, bladder and genitalia for all patients. The V10 and V20 of iliac crests were similar for the N0-1 group but were significantly reduced with IMRT for the N2-3/T4 group (V20 for A = 50.2% compared to B = 33%, C = 32.8%, D = 34.3%). There was no statistical difference between 2-phase (arm C) and single-phase (SIB, arm D) IMRT plans. Conclusion: IMRT is superior to 3D conformal radiation treatment for anal carcinoma with respect to OAR sparing, including bone marrow sparing.