Xingyu Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xingyu Xie has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Dong Liang
Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences
2 shared publications - Hairong Zheng
Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
2 shared publications - Yunlong Gao
Chinese Academy of Sciences Shenzhen University of Technology: Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences, CHINA
2 shared publications - Zhanli Hu
Research Center for Medical AI, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
2 shared publications - En-Tao Liu
PET Center, Department of Nuclear Medicine, Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, China
1 shared publication - Hang Wang
Harbin Engineering College: Heilongjiang Institute of Technology, CHINA
1 shared publication
Latest Publications
- 15 June 2026
- Published by American Association for the Advancement of Science (AAAS) in Research
- Vol. 9
TNM-Accountable Whole-Body 3D FDG PET/CT Report Drafting via Structured Impressions and Organ-Wise Exemplar Synthesis
Whole-body 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) is central to lung cancer staging, yet report drafting remains time intensive and error sensitive, as a single mislocalized finding can alter TNM stage and treatment decisions. We cast PET/CT report drafting as TNM-accountable decision support and propose RIDE, a 2-stage dual-modality 3-dimensional framework that separates TNM-critical anchoring from narrative completion. Stage I generates TNM-oriented structured impressions from paired PET and CT volumes; stage II performs hierarchical organ-wise exemplar retrieval and prompts a large language model to synthesize complete Findings and Impression conditioned on these inspectable artifacts. We curate a multicenter whole-body FDG PET/CT cohort of 1,583 patients from 3 hospitals, all referred for suspected or confirmed lung cancer, and evaluate it on a held-out test set of 520 cases, including 276 external cases from 2 independent institutions. RIDE achieves the strongest overall drafting performance and cross-site generalization, improving a clinically grounded competency metric by +20.4 on the external set and maintaining high clinician ratings under shift (mean Likert 4.00 internal; 4.17 external) while also delivering the best TNM staging performance among evaluated baselines. These findings support workflow-decomposed, TNM-accountable PET/CT drafting as a promising decision-support approach for human verification, and prospective studies will be valuable for further characterizing its utility in real-world clinical workflows.
- 15 June 2026
- Published by American Association for the Advancement of Science (AAAS) in Research
- Vol. 9
TNM-Accountable Whole-Body 3D FDG PET/CT Report Drafting via Structured Impressions and Organ-Wise Exemplar Synthesis
Whole-body 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) is central to lung cancer staging, yet report drafting remains time intensive and error sensitive, as a single mislocalized finding can alter TNM stage and treatment decisions. We cast PET/CT report drafting as TNM-accountable decision support and propose RIDE, a 2-stage dual-modality 3-dimensional framework that separates TNM-critical anchoring from narrative completion. Stage I generates TNM-oriented structured impressions from paired PET and CT volumes; stage II performs hierarchical organ-wise exemplar retrieval and prompts a large language model to synthesize complete Findings and Impression conditioned on these inspectable artifacts. We curate a multicenter whole-body FDG PET/CT cohort of 1,583 patients from 3 hospitals, all referred for suspected or confirmed lung cancer, and evaluate it on a held-out test set of 520 cases, including 276 external cases from 2 independent institutions. RIDE achieves the strongest overall drafting performance and cross-site generalization, improving a clinically grounded competency metric by +20.4 on the external set and maintaining high clinician ratings under shift (mean Likert 4.00 internal; 4.17 external) while also delivering the best TNM staging performance among evaluated baselines. These findings support workflow-decomposed, TNM-accountable PET/CT drafting as a promising decision-support approach for human verification, and prospective studies will be valuable for further characterizing its utility in real-world clinical workflows.
- 7 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (10) , 7373-7386
Multistage Diffusion Model With Phase Error Correction for Fast PET Imaging
Fast PET imaging is clinically important for reducing motion artifacts and improving patient comfort. While recent diffusion-based deep learning methods have shown promise, they often fail to capture the true PET degradation process, suffer from accumulated inference errors, introduce artifacts, and require extensive reconstruction iterations. To address these challenges, we propose a novel multistage diffusion framework tailored for fast PET imaging. At the coarse level, we design a multistage structure to approximate the temporal non-linear PET degradation process in a data-driven manner, using paired PET images collected under different acquisition duration. A Phase Error Correction Network (PECNet) ensures consistency across stages by correcting accumulated deviations. At the fine level, we introduce a deterministic cold diffusion mechanism, which simulates intra-stage degradation through interpolation between known acquisition durations—significantly reducing reconstruction iterations to as few as 10. Evaluations on [68Ga]FAPI and [18F]FDG PET datasets demonstrate the superiority of our approach, achieving peak PSNRs of 36.2 dB and 39.0 dB, respectively, with average SSIMs over 0.97. Our framework offers high-fidelity PET imaging with fewer iterations, making it practical for accelerated clinical imaging.
- 7 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (10) , 7373-7386
Multistage Diffusion Model With Phase Error Correction for Fast PET Imaging
Fast PET imaging is clinically important for reducing motion artifacts and improving patient comfort. While recent diffusion-based deep learning methods have shown promise, they often fail to capture the true PET degradation process, suffer from accumulated inference errors, introduce artifacts, and require extensive reconstruction iterations. To address these challenges, we propose a novel multistage diffusion framework tailored for fast PET imaging. At the coarse level, we design a multistage structure to approximate the temporal non-linear PET degradation process in a data-driven manner, using paired PET images collected under different acquisition duration. A Phase Error Correction Network (PECNet) ensures consistency across stages by correcting accumulated deviations. At the fine level, we introduce a deterministic cold diffusion mechanism, which simulates intra-stage degradation through interpolation between known acquisition durations—significantly reducing reconstruction iterations to as few as 10. Evaluations on [68Ga]FAPI and [18F]FDG PET datasets demonstrate the superiority of our approach, achieving peak PSNRs of 36.2 dB and 39.0 dB, respectively, with average SSIMs over 0.97. Our framework offers high-fidelity PET imaging with fewer iterations, making it practical for accelerated clinical imaging.
- 21 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (5) , 1767-1776
Dual-Polarized Microwave Imaging Probe
- 21 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (5) , 1767-1776
Dual-Polarized Microwave Imaging Probe