Alana Harrington
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Alana Harrington has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- C. David Mazer
St. Michael’s Hospital, University of Toronto
1 shared publication - Daniel Bonneau
Division of Cardiovascular and Thoracic Surgery, St. Michael's Hospital, University of Toronto, 30 Bond Street, Toronto, Ontario M5B 1W8, Canada
1 shared publication - David Latter
Division of Cardiovascular and Thoracic Surgery, St. Michael's Hospital, University of Toronto, 30 Bond Street, Toronto, Ontario M5B 1W8, Canada
1 shared publication - Hosam Fawzy
Department of Cardio-Thoracic Surgery, Faculty of Medicine, University of Tanta, Egypt
1 shared publication - James Mahoney
Department of Plastic Surgery, University of Toronto, Toronto, Ontario, Canada
1 shared publication - Lee Errett
Division of Cardiovascular and Thoracic Surgery, St. Michael's Hospital, University of Toronto, 30 Bond Street, Toronto, Ontario M5B 1W8, Canada
1 shared publication
Latest Publications
- Open Access
- 7 May 2009
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 4 (1) , 19
Sternal plating for primary and secondary sternal closure; can it improve sternal stability?
Background: Sternal instability with mediastinitis is a very serious complication after median sternotomy. Biomechanical studies have suggested superiority of rigid plate fixation over wire cerclage for sternal fixation. This study tests the hypothesis that sternal closure stability can be improved by adding plate fixation in a human cadaver model. Methods: Midline sternotomy was performed in 18 human cadavers. Four sternal closure techniques were tested: (1) approximation with six interrupted steel wires; (2) approximation with six interrupted cables; (3) closure 1 (wires) or 2 (cables) reinforced with a transverse sternal plate at the sixth rib; (4) Closure using 4 sternal plates alone. Intrathoracic pressure was increased in all techniques while sternal separation was measured by three pairs of sonomicrometry crystals fixed at the upper, middle and lower parts of the sternum until 2.0 mm separation was detected. Differences in displacement pressures were analyzed using repeated measures ANOVA and Regression Coefficients. Results: Intrathoracic pressure required to cause 2.0 mm separation increased significantly from 183.3 ± 123.9 to 301.4 ± 204.5 in wires/cables alone vs. wires/cables plus one plate respectively, and to 355.0 ± 210.4 in the 4 plates group (p < 0.05). Regression Coefficients (95% CI) were 120 (47–194) and 142 (66–219) respectively for the plate groups. Conclusion: Transverse sternal plating with 1 or 4 plates significantly improves sternal stability closure in human cadaver model. Adding a single sternal plate to primary closure improves the strength of sternal closure with traditional wiring potentially reducing the risk of sternal dehiscence and could be considered in high risk patients.
- 7 May 2009
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 4 (1) , 19
Open AccessSternal plating for primary and secondary sternal closure; can it improve sternal stability?
Background: Sternal instability with mediastinitis is a very serious complication after median sternotomy. Biomechanical studies have suggested superiority of rigid plate fixation over wire cerclage for sternal fixation. This study tests the hypothesis that sternal closure stability can be improved by adding plate fixation in a human cadaver model. Methods: Midline sternotomy was performed in 18 human cadavers. Four sternal closure techniques were tested: (1) approximation with six interrupted steel wires; (2) approximation with six interrupted cables; (3) closure 1 (wires) or 2 (cables) reinforced with a transverse sternal plate at the sixth rib; (4) Closure using 4 sternal plates alone. Intrathoracic pressure was increased in all techniques while sternal separation was measured by three pairs of sonomicrometry crystals fixed at the upper, middle and lower parts of the sternum until 2.0 mm separation was detected. Differences in displacement pressures were analyzed using repeated measures ANOVA and Regression Coefficients. Results: Intrathoracic pressure required to cause 2.0 mm separation increased significantly from 183.3 ± 123.9 to 301.4 ± 204.5 in wires/cables alone vs. wires/cables plus one plate respectively, and to 355.0 ± 210.4 in the 4 plates group (p < 0.05). Regression Coefficients (95% CI) were 120 (47–194) and 142 (66–219) respectively for the plate groups. Conclusion: Transverse sternal plating with 1 or 4 plates significantly improves sternal stability closure in human cadaver model. Adding a single sternal plate to primary closure improves the strength of sternal closure with traditional wiring potentially reducing the risk of sternal dehiscence and could be considered in high risk patients.