Tadeusz Siwiec
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tadeusz Siwiec has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Krzysztof Jóźwiakowski
Department of Environmental Engineering, University of Life Sciences in Lublin, Leszczyńskiego 7, 20-069 Lublin, Poland
8 shared publications - Lidia Reczek
Institute of Environmental Engineering, Warsaw University of Life Sciences–SGGW, 02-787 Warsaw, Poland
5 shared publications - Magdalena Maria Michel
Institute of Environmental Engineering, Warsaw University of Life Sciences-SGGW, 02-787 Warsaw, Poland
4 shared publications - Michał Marzec
Department of Environmental Engineering and Geodesy, University of Life Sciences in Lublin, Leszczyńskiego 7, 20-069 Lublin, Poland
4 shared publications - Yuliia Trach
Institute of Civil Engineering, Warsaw University of Life Sciences, 02-776 Warsaw, Poland
4 shared publications - Artur Serafin
Department of Environmental Engineering and Geodesy, University of Life Sciences in Lublin, Leszczyńskiego 7, 20-069 Lublin, Poland
3 shared publications
Latest Publications
- Open Access
- 1 March 2026
- Published by WNGB Scientific Publishing House Sp. z o.o. in Journal of Ecological Engineering
- Vol. 27 (3) , 29-44
Pollutant removal efficiency in a meander flow filter applied in the outflow of a constructed wetland wastewater treatment plant – A case study
The aim of the study was to determine the phosphorus removal efficiency of Rockfos® material used to fill a full-scale meander-flow P-filter. This filter is the final element of a hybrid constructed wetland wastewater treatment plant located in Białka, Dębowa Kłoda commune in southeastern...
- 1 March 2026
- Published by WNGB Scientific Publishing House Sp. z o.o. in Journal of Ecological Engineering
- Vol. 27 (3) , 29-44
Open AccessPollutant removal efficiency in a meander flow filter applied in the outflow of a constructed wetland wastewater treatment plant – A case study
The aim of the study was to determine the phosphorus removal efficiency of Rockfos® material used to fill a full-scale meander-flow P-filter. This filter is the final element of a hybrid constructed wetland wastewater treatment plant located in Białka, Dębowa Kłoda commune in southeastern...
- Open Access
Analysis of the Functional Efficiency of a Prototype Filtration System Dedicated for Natural Swimming Ponds
Water treatment systems in swimming ponds support the natural self-cleaning capabilities of water based on the functions of repository macrophytes in their regeneration zone and the regulation of the internal metabolism of the reservoirs. As part of the project, a functional modular filtration chamber with system multiplication capabilities was designed and created. This element is dedicated to water treatment systems in natural swimming ponds. The prototype system consisted of modular filtration chambers and pump sections, as well as equipment adapted to the conditions prevailing in the eco-pool. An innovative solution for selective shutdown of the filtration chamber without closing the circulation circuit was also used, which forms the basis of a patent application. A verified high-performance adsorbent, Rockfos® modified limestone, was used in the filtration chamber. In order to determine the effective filtration rate for three small test ponds with different flow rates (5 m/h, 10 m/h and 15 m/h), the selected physicochemical parameters of water (temperature, pH, electrolytical conductivity, oxygen saturation, total hardness, nitrites, nitrates, and total phosphorus, including adsorption efficiency and bed absorption capacity) were researched before and after filtration. Tests were also carried out on the composition of fecal bacteria and phyto- and zooplankton. Based on high effective phosphorus filtration efficiency of 32.65% during the operation of the bed, the following were determined: no exceedances of the standards for the tested parameters in relation to the German standards for eco-pools (FLL—Forschungsgesellschaft Landschaftsentwicklung Landschaftsbau e. V., 2011); lower number of fecal pathogens (on average 393—coliform bacteria; 74—Escherichia coli; 34—fecal enterococci, most probably number/100 mL); the lowest share of problematic cyanobacteria in phytoplankton (3 in number and 3—biomass); low chlorophyll a content (2.2 µg/dm3—oligotrophy) and the presence of more favorable smaller forms of zooplankton, an effective filtration speed of 5 m/h. This velocity was recommended in the FLL standards for swimming ponds, which were adopted in this study as a reference for rapid filters. In testing the functional efficiency of a dedicated filtration system for a Type II test pond (50 m2—area and 33 m3—capacity), at a filtration rate of 5 m/h, an average effective phosphorus adsorption efficiency of 18.28–53.98% was observed under the bed work-in-progress conditions. Analyses of other physicochemical water parameters, with appropriate calculations and statistical tests, indicated progressive functional efficiency of the system under bathing conditions.
Open AccessAnalysis of the Functional Efficiency of a Prototype Filtration System Dedicated for Natural Swimming Ponds
Water treatment systems in swimming ponds support the natural self-cleaning capabilities of water based on the functions of repository macrophytes in their regeneration zone and the regulation of the internal metabolism of the reservoirs. As part of the project, a functional modular filtration chamber with system multiplication capabilities was designed and created. This element is dedicated to water treatment systems in natural swimming ponds. The prototype system consisted of modular filtration chambers and pump sections, as well as equipment adapted to the conditions prevailing in the eco-pool. An innovative solution for selective shutdown of the filtration chamber without closing the circulation circuit was also used, which forms the basis of a patent application. A verified high-performance adsorbent, Rockfos® modified limestone, was used in the filtration chamber. In order to determine the effective filtration rate for three small test ponds with different flow rates (5 m/h, 10 m/h and 15 m/h), the selected physicochemical parameters of water (temperature, pH, electrolytical conductivity, oxygen saturation, total hardness, nitrites, nitrates, and total phosphorus, including adsorption efficiency and bed absorption capacity) were researched before and after filtration. Tests were also carried out on the composition of fecal bacteria and phyto- and zooplankton. Based on high effective phosphorus filtration efficiency of 32.65% during the operation of the bed, the following were determined: no exceedances of the standards for the tested parameters in relation to the German standards for eco-pools (FLL—Forschungsgesellschaft Landschaftsentwicklung Landschaftsbau e. V., 2011); lower number of fecal pathogens (on average 393—coliform bacteria; 74—Escherichia coli; 34—fecal enterococci, most probably number/100 mL); the lowest share of problematic cyanobacteria in phytoplankton (3 in number and 3—biomass); low chlorophyll a content (2.2 µg/dm3—oligotrophy) and the presence of more favorable smaller forms of zooplankton, an effective filtration speed of 5 m/h. This velocity was recommended in the FLL standards for swimming ponds, which were adopted in this study as a reference for rapid filters. In testing the functional efficiency of a dedicated filtration system for a Type II test pond (50 m2—area and 33 m3—capacity), at a filtration rate of 5 m/h, an average effective phosphorus adsorption efficiency of 18.28–53.98% was observed under the bed work-in-progress conditions. Analyses of other physicochemical water parameters, with appropriate calculations and statistical tests, indicated progressive functional efficiency of the system under bathing conditions.
- Open Access
- 1 June 2025
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Journal of Ecological Engineering
- Vol. 26 (6) , 298-314
Comparative analysis of phosphorus removal efficiency from water on selected filter beds for use in the natural swimming pond filtration systems
This study aimed to compare the adsorption efficiency of phosphorus and its possible removal using three types of filter materials: modified rock opoka (Rockfos®), iron grit (Sulfur E), and limestone, based on laboratory column studies. Adsorption studies of phosphorus were carried out in...
- 1 June 2025
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Journal of Ecological Engineering
- Vol. 26 (6) , 298-314
Open AccessComparative analysis of phosphorus removal efficiency from water on selected filter beds for use in the natural swimming pond filtration systems
This study aimed to compare the adsorption efficiency of phosphorus and its possible removal using three types of filter materials: modified rock opoka (Rockfos®), iron grit (Sulfur E), and limestone, based on laboratory column studies. Adsorption studies of phosphorus were carried out in...
- Open Access
- 2 February 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (3) , 1525
Water Consumption, Quantity and Quality of Wastewater and Sewage Sludge from Polish Dairies
The peculiarity of the wastewater produced in Polish dairies stems from the frequency and specific technology of cottage cheese production. The aim of this study was to determine the water consumption and the quantity and quality of wastewater and sewage sludge discharged from Polish dairies based on the size of the plant and the production profile of the plant to characterize the wastewater treatment plants (WWTPs). Data were collected from eighteen dairies. Most of them have their own WWTP. Water consumption ranged from 1.5 litres (L) of water per litre of milk processed to 3.71 L/L. The specific volume of wastewater ranged from 1.18 to 5.78 L per L of milk processed. The raw wastewater concentrations were comparable to those of dairy wastewater in other European countries. Despite the disposal of domestic wastewater in WWTPs, the results of the sanitary examinations of the sludge showed it was suitable for agricultural purposes. Its heavy metal also made it applicable on agricultural land. The ratio of the sludge to raw milk processing was between 0.137 and 7.927 kg of sludge per 100 L of milk processed. The amount of sludge produced per pollutant (BOD) load removed ranged from 0.404 to 18.895 kg/kg BODremoved.
- 2 February 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (3) , 1525
Open AccessWater Consumption, Quantity and Quality of Wastewater and Sewage Sludge from Polish Dairies
The peculiarity of the wastewater produced in Polish dairies stems from the frequency and specific technology of cottage cheese production. The aim of this study was to determine the water consumption and the quantity and quality of wastewater and sewage sludge discharged from Polish dairies based on the size of the plant and the production profile of the plant to characterize the wastewater treatment plants (WWTPs). Data were collected from eighteen dairies. Most of them have their own WWTP. Water consumption ranged from 1.5 litres (L) of water per litre of milk processed to 3.71 L/L. The specific volume of wastewater ranged from 1.18 to 5.78 L per L of milk processed. The raw wastewater concentrations were comparable to those of dairy wastewater in other European countries. Despite the disposal of domestic wastewater in WWTPs, the results of the sanitary examinations of the sludge showed it was suitable for agricultural purposes. Its heavy metal also made it applicable on agricultural land. The ratio of the sludge to raw milk processing was between 0.137 and 7.927 kg of sludge per 100 L of milk processed. The amount of sludge produced per pollutant (BOD) load removed ranged from 0.404 to 18.895 kg/kg BODremoved.
- Open Access
- 1 December 2024
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Advances in Science and Technology Research Journal
- Vol. 18 (8) , 319-332
Effect of Rockfos Material Granulation on Phosphorus Sorption Kinetics
The objective of the study was to analyze the kinetics of phosphorus sorption on Rockfos® material in terms of its potential use in water and wastewater treatment. The objective of the study was to ascertain the sorption capacity of the material in relation to its granularity and the predominant...
- 1 December 2024
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Advances in Science and Technology Research Journal
- Vol. 18 (8) , 319-332
Open AccessEffect of Rockfos Material Granulation on Phosphorus Sorption Kinetics
The objective of the study was to analyze the kinetics of phosphorus sorption on Rockfos® material in terms of its potential use in water and wastewater treatment. The objective of the study was to ascertain the sorption capacity of the material in relation to its granularity and the predominant...
- Open Access
- 26 November 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (23) , 10996
Modeling of Phosphate Sorption Process on the Surface of Rockfos® Material Using Langmuir Isotherms
In this study, we aimed to develop a mathematical description of the process of phosphate sorption on Rockfos® material using the Langmuir isotherm and determine the basic parameters for modeling this process. The Rockfos® material was formed through the thermal treatment of opoka at 980 °C and is highly reactive due to its significant calcium and silicon compound content. This study included an evaluation of the phosphate retention efficiency on the material as a function of the phosphate concentration in the initial solution (0.5 mg/L, 1.0 mg/L, and 2.0 mg/L), sorbent grain size (1.0–1.6 mm, 1.6–2.5 mm, and 2.0–5.0 mm), and process temperature (5 °C, 10 °C, 15 °C, 20 °C, and 25 °C). It was found that an increase in the process temperature and the phosphate concentration in the solution favored sorption, while the effect of the sorbent grain size was ambiguous. It was determined that sorption can be described well using the Langmuir linearization of the Langmuir model. Thermodynamic analysis and the separation coefficient suggest that phosphorus sorption on Rockfos® material is primarily based on chemisorption, and the process is endothermic and spontaneous over the entire temperature range. The determined parameters of the tested material, especially the qmax (maximum sorption capacity), provide a basis for the design of a filter for removing phosphate from wastewater, assuming that the load is equal to the inflow to the filter and adheres to the specified requirements for treated wastewater.
- 26 November 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (23) , 10996
Open AccessModeling of Phosphate Sorption Process on the Surface of Rockfos® Material Using Langmuir Isotherms
In this study, we aimed to develop a mathematical description of the process of phosphate sorption on Rockfos® material using the Langmuir isotherm and determine the basic parameters for modeling this process. The Rockfos® material was formed through the thermal treatment of opoka at 980 °C and is highly reactive due to its significant calcium and silicon compound content. This study included an evaluation of the phosphate retention efficiency on the material as a function of the phosphate concentration in the initial solution (0.5 mg/L, 1.0 mg/L, and 2.0 mg/L), sorbent grain size (1.0–1.6 mm, 1.6–2.5 mm, and 2.0–5.0 mm), and process temperature (5 °C, 10 °C, 15 °C, 20 °C, and 25 °C). It was found that an increase in the process temperature and the phosphate concentration in the solution favored sorption, while the effect of the sorbent grain size was ambiguous. It was determined that sorption can be described well using the Langmuir linearization of the Langmuir model. Thermodynamic analysis and the separation coefficient suggest that phosphorus sorption on Rockfos® material is primarily based on chemisorption, and the process is endothermic and spontaneous over the entire temperature range. The determined parameters of the tested material, especially the qmax (maximum sorption capacity), provide a basis for the design of a filter for removing phosphate from wastewater, assuming that the load is equal to the inflow to the filter and adheres to the specified requirements for treated wastewater.
- Open Access
- 1 August 2024
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Journal of Ecological Engineering
- Vol. 25 (8) , 317-324
The Influence of Atmospheric Air Temperature on the Consumption of Natural Gas in Terms of Heating Costs of a Single-Family Building – A Case Study
The aim of this study was to determine the costs of heating a single-family detached home with natural gas during the heating season, considering the variability of atmospheric air temperature. In addition, this study composes a forecast of monthly costs incurred for heating a single-family...
- 1 August 2024
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Journal of Ecological Engineering
- Vol. 25 (8) , 317-324
Open AccessThe Influence of Atmospheric Air Temperature on the Consumption of Natural Gas in Terms of Heating Costs of a Single-Family Building – A Case Study
The aim of this study was to determine the costs of heating a single-family detached home with natural gas during the heating season, considering the variability of atmospheric air temperature. In addition, this study composes a forecast of monthly costs incurred for heating a single-family...
- Open Access
- 1 August 2024
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Advances in Science and Technology Research Journal
- Vol. 18 (4) , 296-311
Efficiency of the Installation to Treatment of Outflow from the Hybrid Constructed Wetland System and Possibility of Reuse of Treated Wastewater in the Household
The purpose of this study was to determine the effectiveness of the operation of a novel installation for treating the outflow from a hybrid constructed wetland system and the possibility of domestic wastewater reuse. The study was carried out in 2022-2023 at a facility located in the Polesie...
- 1 August 2024
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Advances in Science and Technology Research Journal
- Vol. 18 (4) , 296-311
Open AccessEfficiency of the Installation to Treatment of Outflow from the Hybrid Constructed Wetland System and Possibility of Reuse of Treated Wastewater in the Household
The purpose of this study was to determine the effectiveness of the operation of a novel installation for treating the outflow from a hybrid constructed wetland system and the possibility of domestic wastewater reuse. The study was carried out in 2022-2023 at a facility located in the Polesie...
- Open Access
- 31 May 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (11) , 4709
Pollutant Removal Efficiency in a Rainwater Treatment System in Roztocze National Park (Poland)
The aim of this paper was to determine the efficiency of a rainwater treatment installation located near the farm buildings of Roztocze National Park (RNP), Poland. The rainwater treatment system, consisting of two polypropylene filters, one activated carbon filter and a UV lamp, was examined. Samples of raw and treated rainwater were collected once a month from June to December 2023. The study shows that average efficiency of pollutant removal in the analysed rainwater treatment system was not very high and amounted to 38.8% for ammonia, 29.6% for turbidity, 27.9% for NO2, 19.8% for NO3, and 6.9% for copper. The low efficiency values can be explained by the low concentration of these parameters in rainwater from the tanks. The efficiency of removing microbiological contaminants was very high and ranged from approximately 98% to 100%. It was shown that the UV lamp ensures very good disinfection of rainwater. The study shows that rainwater treated using filtration and disinfection (UV lamp) can be used for watering the Polish Konik horses living in the park, as well as for washing vehicles, watering green areas, or flushing toilets. The present findings can be used in the design of a new system for managing rainwater that is planned to be built in the RNP’s Animal Breeding Centre, as well as to prepare other rainwater systems, especially in protected areas.
- 31 May 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (11) , 4709
Open AccessPollutant Removal Efficiency in a Rainwater Treatment System in Roztocze National Park (Poland)
The aim of this paper was to determine the efficiency of a rainwater treatment installation located near the farm buildings of Roztocze National Park (RNP), Poland. The rainwater treatment system, consisting of two polypropylene filters, one activated carbon filter and a UV lamp, was examined. Samples of raw and treated rainwater were collected once a month from June to December 2023. The study shows that average efficiency of pollutant removal in the analysed rainwater treatment system was not very high and amounted to 38.8% for ammonia, 29.6% for turbidity, 27.9% for NO2, 19.8% for NO3, and 6.9% for copper. The low efficiency values can be explained by the low concentration of these parameters in rainwater from the tanks. The efficiency of removing microbiological contaminants was very high and ranged from approximately 98% to 100%. It was shown that the UV lamp ensures very good disinfection of rainwater. The study shows that rainwater treated using filtration and disinfection (UV lamp) can be used for watering the Polish Konik horses living in the park, as well as for washing vehicles, watering green areas, or flushing toilets. The present findings can be used in the design of a new system for managing rainwater that is planned to be built in the RNP’s Animal Breeding Centre, as well as to prepare other rainwater systems, especially in protected areas.
- Open Access
Changes of Water Consumption in a Forester’s Lodge in Polesie National Park (Poland)—Case Study
The object of the present study was to analyse water consumption in a four-person household (park employee housing) located in the village of Kulczyn in Polesie National Park (PNP) in Poland. The wastewater from the buildings was discharged to a hybrid constructed wetland integrated into a closed-loop water system. As part of the study, seasonal, weekly, and daily changes in water consumption and the amount of water used to flush the toilets were determined over a period of one year. It was shown that the average daily water consumption in the entire house was 437 L/d, or 109 L/p/d (litres/person/day). The average daily water consumption per capita was, therefore, similar to that reported for Poland by the European Commission and much lower than that reported for Western European countries (150–250 L/p/d). The highest water withdrawals were recorded in the spring season (March–May) at 117–122 L/p/d, and the lowest in the holiday month of July—88 L/p/d. The highest water consumption levels during the week were recorded on Saturdays—an average of 136 L/p/d, and the lowest on Wednesdays—an average of 92 L/p/d. During the 24 h of a day, the highest water withdrawals were observed late in the evening (10–11 pm) and periodically in the morning (around 10 am), on weekends, and during the holiday period (July and August). It was shown that the amount of water used to flush toilets represented on average about 20% of the total amount of water consumed. This indicates that approximately 88 L/d of water was used to flush the toilets in the homestead under study.
Open AccessChanges of Water Consumption in a Forester’s Lodge in Polesie National Park (Poland)—Case Study
The object of the present study was to analyse water consumption in a four-person household (park employee housing) located in the village of Kulczyn in Polesie National Park (PNP) in Poland. The wastewater from the buildings was discharged to a hybrid constructed wetland integrated into a closed-loop water system. As part of the study, seasonal, weekly, and daily changes in water consumption and the amount of water used to flush the toilets were determined over a period of one year. It was shown that the average daily water consumption in the entire house was 437 L/d, or 109 L/p/d (litres/person/day). The average daily water consumption per capita was, therefore, similar to that reported for Poland by the European Commission and much lower than that reported for Western European countries (150–250 L/p/d). The highest water withdrawals were recorded in the spring season (March–May) at 117–122 L/p/d, and the lowest in the holiday month of July—88 L/p/d. The highest water consumption levels during the week were recorded on Saturdays—an average of 136 L/p/d, and the lowest on Wednesdays—an average of 92 L/p/d. During the 24 h of a day, the highest water withdrawals were observed late in the evening (10–11 pm) and periodically in the morning (around 10 am), on weekends, and during the holiday period (July and August). It was shown that the amount of water used to flush toilets represented on average about 20% of the total amount of water consumed. This indicates that approximately 88 L/d of water was used to flush the toilets in the homestead under study.