HAHossam Ahmad

Hossam Ahmad

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hossam Ahmad has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Andreas Klehr

    Ferdinand-Braun-Institut, Leibniz-Institut für Höchstfrequenztechnik Optoelectronics Department Gustav-Kirchhoff-Str. 4 12489 Berlin Germany

    1 shared publication
  • Bernd Sumpf

    Ferdinand-Braun-Institut, Leibniz-Institut für Höchstfrequenztechnik Optoelectronics Department Gustav-Kirchhoff-Str. 4 12489 Berlin Germany

    1 shared publication
  • Heinz-Detlef Kronfeldt

    Institut für Optik und Atomare Physik Technische Universitä t Berlin Sekr. EW 0-1 Hardenbergstraße, 36 10623 Berlin Germany

    1 shared publication
  • Kay Sowoidnich

    Ferdinand‐Braun‐Institut (FBH) Berlin Germany

    1 shared publication

Latest Publications

  • Open Access

    Insitu Raman Setup for Deep Ocean Investigations Applying Two 1000 m Optical Fiber Cables and a 785 nm High Power Diode Laser

    by Hossam Ahmad, Bernd Sumpf, Kay Sowoidnich, Andreas Klehr, Heinz-Detlef Kronfeldt

    A laboratory Raman-set-up is used to demonstrate the feasibility of deep ocean measurements using 1000 m long low OH optical fibres for the excitation of the substances under study and the collection of the Raman photons. As excitation laser a 785 nm broad area distributed feedback (DFB-BA) high-power diode laser with an optical power of 1.25 W and a spectral emission width below 0.6 nm suitable for Raman spectroscopy was used.After passing beam shaping and focusing optics, a 1000 m long fiber, and a pressure-resistant optode275 mW of optical power were available at the sample. The optode also collects the Raman photons and focuses the light into the second 1000 m long fibre, which transfers the light into a spectrometer. To determine the reachable signal-to-noise ratio, Raman spectra were taken from natural minerals (sulfates, carbonates, sulfur). Even for weak Raman-signal and short integration times of 0.5 s per spectrum, the signal-to-noise ratio of 60 would be suitable for the in-situ Raman spectroscopy in deep ocean applications. Even longer optical fibres would increase to integration time up to 60 s. The shown set-up offers the opportunity to used different laser sources and spectrometers on board of a ship, only the fibres and the optode had to be suitable for deep sea conditions.