Kristina Blom
Research Subjects
Research Interests
Kristina Blom has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Bodil Hakonen
Medibiome AB, 431 53 Mölndal, Sweden
1 shared publicationEva Larkö
Medibiome AB, 431 53 Mölndal, Sweden
1 shared publicationLinnea K. Lönnberg
Medibiome AB, 431 53 Mölndal, Sweden
1 shared publication
Latest Publications
- Open Access
- 26 February 2015
- Published by Springer Nature in Archives of Public Health
- Vol. 73 (1) , 1-8
Drainage systems, an occluded source of sanitation related outbreaks
Drainage systems and its role in sanitation related outbreaks are evident but still occluded once it has been installed. This current review evaluates if drainage systems can cause infections and thus be of clinical concern. A review of the literature was analyzed. Papers, guidelines, and quality management systems have been considered. Adequate sanitation is fundamental and a prerequisite for safe life and productivity. In contrast, malfunctioning sanitation has been reported to cause outbreaks all over the world. In areas with no sanitation, diarrheal mortality is high and has been shown to decrease by 36% after interventions to improve sanitation. Often, infections are faeces associated and when present in wastewater and sewage sludge poses a high risk of infection upon exposure. Hence, there are working safety guidelines and in industries where infection reduction is essential strict quality assurance systems, i.e. HACCP (hazard analysis critical control points) and GMP (Good Manufacturing Practice) must be complied. Healthcare has recently taken interest in the HACCP system in their efforts to reduce healthcare associated infections as a response to increasing number of ineffective antibiotics and the threat of mortality rate like the pre-antibiotic era. The last few years have called for immediate action to contain the emergence of increasing resistant microorganisms. Resistance is obtained as a result of overuse and misuse of antibiotics in both healthcare and agriculture. Also, by the discharge of antibiotics from manufacturers, healthcare and society. One mechanism of development of novel resistant pathogens has been shown to be by effortless sharing of genetic mobile elements coding for resistance from microbes in the environment to human microbes. These pathogens have been sampled from the drainage systems. These were noticed owing to their possession of an unusual antibiotic resistance profile linking them to the outbreak. Often the cause of sanitation related outbreaks is due to inadequate sanitation and maintenance. However, in general these infections probably go unnoticed. Drainage systems and its maintenance, if neglected, could pose a threat in both community and healthcare causing infections as well as emergence of multi-resistant bacteria that could cause unpredictable clinical manifestations.
- 26 February 2015
- Published by Springer Nature in Archives of Public Health
- Vol. 73 (1) , 1-8
Open AccessDrainage systems, an occluded source of sanitation related outbreaks
Drainage systems and its role in sanitation related outbreaks are evident but still occluded once it has been installed. This current review evaluates if drainage systems can cause infections and thus be of clinical concern. A review of the literature was analyzed. Papers, guidelines, and quality management systems have been considered. Adequate sanitation is fundamental and a prerequisite for safe life and productivity. In contrast, malfunctioning sanitation has been reported to cause outbreaks all over the world. In areas with no sanitation, diarrheal mortality is high and has been shown to decrease by 36% after interventions to improve sanitation. Often, infections are faeces associated and when present in wastewater and sewage sludge poses a high risk of infection upon exposure. Hence, there are working safety guidelines and in industries where infection reduction is essential strict quality assurance systems, i.e. HACCP (hazard analysis critical control points) and GMP (Good Manufacturing Practice) must be complied. Healthcare has recently taken interest in the HACCP system in their efforts to reduce healthcare associated infections as a response to increasing number of ineffective antibiotics and the threat of mortality rate like the pre-antibiotic era. The last few years have called for immediate action to contain the emergence of increasing resistant microorganisms. Resistance is obtained as a result of overuse and misuse of antibiotics in both healthcare and agriculture. Also, by the discharge of antibiotics from manufacturers, healthcare and society. One mechanism of development of novel resistant pathogens has been shown to be by effortless sharing of genetic mobile elements coding for resistance from microbes in the environment to human microbes. These pathogens have been sampled from the drainage systems. These were noticed owing to their possession of an unusual antibiotic resistance profile linking them to the outbreak. Often the cause of sanitation related outbreaks is due to inadequate sanitation and maintenance. However, in general these infections probably go unnoticed. Drainage systems and its maintenance, if neglected, could pose a threat in both community and healthcare causing infections as well as emergence of multi-resistant bacteria that could cause unpredictable clinical manifestations.
- Open Access
- 18 February 2014
- Published by Hindawi Limited in International Journal of Biomaterials
- Vol. 2014, 1-5
A Novel Qualitative and Quantitative Biofilm Assay Based on 3D Soft Tissue
The lack of predictablein vitromethods to analyze antimicrobial activity could play a role in the development of resistance to antibiotics. Current used methods analyze planktonic cells but for the method to be clinically relevant, biofilm inin vivolike conditions ought to be studied. Hence, our group has developed a qualitative and quantitative method within vivolike 3D tissue for prediction of antimicrobial activity in reality. Devices (wound dressings) were applied on top ofPseudomonas aeruginosainoculated Muller-Hinton (MH) agar or 3D synthetic soft tissues (SST) and incubated for 24 hours. The antibacterial activity was then analyzed visually and by viable counts. On MH agar two out of three silver containing devices showed zone of inhibitions (ZOI) and on SST, ZOI were detected for all three. Corroborating results were found upon evaluating the bacterial load in SST and shown to be silver concentration dependent. In conclusion, a novel method was developed combining visual rapid screening and quantitative evaluation of the antimicrobial activity in both tissue and devices. It uses tissue allowing biofilm formation thus mimicking reality closely. These conditions are essential in order to predict antimicrobial activity of medical devices in the task to prevent device related infections.
- 18 February 2014
- Published by Hindawi Limited in International Journal of Biomaterials
- Vol. 2014, 1-5
Open AccessA Novel Qualitative and Quantitative Biofilm Assay Based on 3D Soft Tissue
The lack of predictablein vitromethods to analyze antimicrobial activity could play a role in the development of resistance to antibiotics. Current used methods analyze planktonic cells but for the method to be clinically relevant, biofilm inin vivolike conditions ought to be studied. Hence, our group has developed a qualitative and quantitative method within vivolike 3D tissue for prediction of antimicrobial activity in reality. Devices (wound dressings) were applied on top ofPseudomonas aeruginosainoculated Muller-Hinton (MH) agar or 3D synthetic soft tissues (SST) and incubated for 24 hours. The antibacterial activity was then analyzed visually and by viable counts. On MH agar two out of three silver containing devices showed zone of inhibitions (ZOI) and on SST, ZOI were detected for all three. Corroborating results were found upon evaluating the bacterial load in SST and shown to be silver concentration dependent. In conclusion, a novel method was developed combining visual rapid screening and quantitative evaluation of the antimicrobial activity in both tissue and devices. It uses tissue allowing biofilm formation thus mimicking reality closely. These conditions are essential in order to predict antimicrobial activity of medical devices in the task to prevent device related infections.