Rajan Kanhirodan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rajan Kanhirodan has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Chelur K. Rasmi
Nanobioimaging Laboratory, IAP, Indian Institute of Science 1 , Bangalore 560012, India
1 shared publicationKalyanee Shirlekar
Molecular Reproduction, Development and Genetics, Indian Institute of Science 4 , Bangalore 560012, India
1 shared publication- Manob Jyoti Saikia
Biomedical Sensors & Systems Lab, University of Memphis, Memphis, TN 38152, USA
1 shared publication - Partha Pratim Mondal
Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore, India.
1 shared publication - Rakesh Manjappa
Department of Radiation Oncology, Stanford University School of Medicine
1 shared publication Ram Mohan Vasu
Department of Instrumentation and Applied Physics
1 shared publication
Latest Publications
- 11 December 2017
- Published by AIP Publishing in Applied Physics Letters
- Vol. 111 (24) , 243702
Integrated light-sheet imaging and flow-based enquiry (iLIFE) system for 3D in-vivo imaging of multicellular organism
We propose and demonstrate a light-sheet-based 3D interrogation system on a microfluidic platform for screening biological specimens during flow. To achieve this, a diffraction-limited light-sheet (with a large field-of-view) is employed to optically section the specimens flowing through the microfluidic channel. This necessitates optimization of the parameters for the illumination sub-system (illumination intensity, light-sheet width, and thickness), microfluidic specimen platform (channel-width and flow-rate), and detection sub-system (camera exposure time and frame rate). Once optimized, these parameters facilitate cross-sectional imaging and 3D reconstruction of biological specimens. The proposed integrated light-sheet imaging and flow-based enquiry (iLIFE) imaging technique enables single-shot sectional imaging of a range of specimens of varying dimensions, ranging from a single cell (HeLa cell) to a multicellular organism (C. elegans). 3D reconstruction of the entire C. elegans is achieved in real-time and with an exposure time of few hundred micro-seconds. A maximum likelihood technique is developed and optimized for the iLIFE imaging system. We observed an intracellular resolution for mitochondria-labeled HeLa cells, which demonstrates the dynamic resolution of the iLIFE system. The proposed technique is a step towards achieving flow-based 3D imaging. We expect potential applications in diverse fields such as structural biology and biophysics.
- 11 December 2017
- Published by AIP Publishing in Applied Physics Letters
- Vol. 111 (24) , 243702
Integrated light-sheet imaging and flow-based enquiry (iLIFE) system for 3D in-vivo imaging of multicellular organism
We propose and demonstrate a light-sheet-based 3D interrogation system on a microfluidic platform for screening biological specimens during flow. To achieve this, a diffraction-limited light-sheet (with a large field-of-view) is employed to optically section the specimens flowing through the microfluidic channel. This necessitates optimization of the parameters for the illumination sub-system (illumination intensity, light-sheet width, and thickness), microfluidic specimen platform (channel-width and flow-rate), and detection sub-system (camera exposure time and frame rate). Once optimized, these parameters facilitate cross-sectional imaging and 3D reconstruction of biological specimens. The proposed integrated light-sheet imaging and flow-based enquiry (iLIFE) imaging technique enables single-shot sectional imaging of a range of specimens of varying dimensions, ranging from a single cell (HeLa cell) to a multicellular organism (C. elegans). 3D reconstruction of the entire C. elegans is achieved in real-time and with an exposure time of few hundred micro-seconds. A maximum likelihood technique is developed and optimized for the iLIFE imaging system. We observed an intracellular resolution for mitochondria-labeled HeLa cells, which demonstrates the dynamic resolution of the iLIFE system. The proposed technique is a step towards achieving flow-based 3D imaging. We expect potential applications in diverse fields such as structural biology and biophysics.
- Open Access
- 10 April 2014
- Published by Wiley in International Journal of Biomedical Imaging
- Vol. 2014, 1-13
High-Speed GPU-Based Fully Three-Dimensional Diffuse Optical Tomographic System
We have developed a graphics processor unit (GPU-) based high-speed fully 3D system for diffuse optical tomography (DOT). The reduction in execution time of 3D DOT algorithm, a severely ill-posed problem, is made possible through the use of (1) an algorithmic improvement that uses Broyden approach for updating the Jacobian matrix and thereby updating the parameter matrix and (2) the multinode multithreaded GPU and CUDA (Compute Unified Device Architecture) software architecture. Two different GPU implementations of DOT programs are developed in this study: (1) conventional C language program augmented by GPU CUDA and CULA routines (C GPU), (2) MATLAB program supported by MATLAB parallel computing toolkit for GPU (MATLAB GPU). The computation time of the algorithm on host CPU and the GPU system is presented for C and Matlab implementations. The forward computation uses finite element method (FEM) and the problem domain is discretized into 14610, 30823, and 66514 tetrahedral elements. The reconstruction time, so achieved for one iteration of the DOT reconstruction for 14610 elements, is 0.52 seconds for a C based GPU program for 2-plane measurements. The corresponding MATLAB based GPU program took 0.86 seconds. The maximum number of reconstructed frames so achieved is 2 frames per second.
- 10 April 2014
- Published by Wiley in International Journal of Biomedical Imaging
- Vol. 2014, 1-13
Open AccessHigh-Speed GPU-Based Fully Three-Dimensional Diffuse Optical Tomographic System
We have developed a graphics processor unit (GPU-) based high-speed fully 3D system for diffuse optical tomography (DOT). The reduction in execution time of 3D DOT algorithm, a severely ill-posed problem, is made possible through the use of (1) an algorithmic improvement that uses Broyden approach for updating the Jacobian matrix and thereby updating the parameter matrix and (2) the multinode multithreaded GPU and CUDA (Compute Unified Device Architecture) software architecture. Two different GPU implementations of DOT programs are developed in this study: (1) conventional C language program augmented by GPU CUDA and CULA routines (C GPU), (2) MATLAB program supported by MATLAB parallel computing toolkit for GPU (MATLAB GPU). The computation time of the algorithm on host CPU and the GPU system is presented for C and Matlab implementations. The forward computation uses finite element method (FEM) and the problem domain is discretized into 14610, 30823, and 66514 tetrahedral elements. The reconstruction time, so achieved for one iteration of the DOT reconstruction for 14610 elements, is 0.52 seconds for a C based GPU program for 2-plane measurements. The corresponding MATLAB based GPU program took 0.86 seconds. The maximum number of reconstructed frames so achieved is 2 frames per second.
- 1 January 2014
- Published by Optica Publishing Group
- p. BS3A.51
Polarized light Monte Carlo simulations of Depolarization contrast from Gold Nanoparticles
Polarized light Monte Carlo model is investigated for interaction in turbid media containing nanoparticles as contrast agents. Depolarization of linear and circular polarized backscattered light is analyzed for different size of nanoparticles.
- 1 January 2014
- Published by Optica Publishing Group
- p. BS3A.51
Polarized light Monte Carlo simulations of Depolarization contrast from Gold Nanoparticles
Polarized light Monte Carlo model is investigated for interaction in turbid media containing nanoparticles as contrast agents. Depolarization of linear and circular polarized backscattered light is analyzed for different size of nanoparticles.