Manuel García
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Manuel García has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Juan Ródenas
University of Castilla-La Mancha
9 shared publications - Raúl Alcaraz
Research Group in Electronic, Biomedical and Telecommunication Engineering, University of Castilla-La Mancha, 16071 Cuenca, Spain
8 shared publications - Jose Joaquin Rieta
BioMIT.org, Electronic Engineering Department, Universitat Politecnica de Valencia, 46022 Valencia, Spain
6 shared publications - Pilar Escribano
University of Castilla-La Mancha
4 shared publications - Alejandro Macho
UNED
1 shared publication - Elio Sancristobal
UNED (Spain)
1 shared publication
Latest Publications
- 31 August 2024
- Published by Springer Nature
- p. 129-137
Automatic Detection of High-Quality Fibrillatory Waves Segments from Atrial Fibrillation Electrocardiographic Recordings
- 31 August 2024
- Published by Springer Nature
- p. 129-137
Automatic Detection of High-Quality Fibrillatory Waves Segments from Atrial Fibrillation Electrocardiographic Recordings
- Open Access
A novel wavelet-based filtering strategy to remove powerline interference from electrocardiograms with atrial fibrillation
"Objective: The electrocardiogram (ECG) is currently the most widely used recording to diagnose cardiac disorders, including the most common supraventricular arrhythmia, such as atrial fibrillation (AF). However, different types of electrical disturbances, in which power-line interference (PLI) is a major problem, can mask and distort the original ECG morphology. This is a significant issue in the context of AF, because accurate characterization of fibrillatory waves (f-waves) is unavoidably required to improve current knowledge about its mechanisms. This work introduces a new algorithm able to reduce high levels of PLI and preserve, simultaneously, the original ECG morphology. Approach: The method is based on stationary wavelet transform shrinking and makes use of a new thresholding function designed to work successfully in a wide variety of scenarios. In fact, it has been validated in a general context with 48 ECG recordings obtained from pathological and non-pathological conditions, as well as in the particular context of AF, where 380 synthesized and 20 long-term real ECG recordings were analyzed. Main results: In both situations, the algorithm has reported a notably better performance than common methods designed for the same purpose. Moreover, its effectiveness has proven to be optimal for dealing with ECG recordings affected by AF, since f-waves remained almost intact after removing very high levels of noise. Significance: The proposed algorithm may facilitate a reliable characterization of the f-waves, preventing them from not being masked by the PLI nor distorted by an unsuitable filtering applied to ECG recordings with AF."
Open AccessA novel wavelet-based filtering strategy to remove powerline interference from electrocardiograms with atrial fibrillation
"Objective: The electrocardiogram (ECG) is currently the most widely used recording to diagnose cardiac disorders, including the most common supraventricular arrhythmia, such as atrial fibrillation (AF). However, different types of electrical disturbances, in which power-line interference (PLI) is a major problem, can mask and distort the original ECG morphology. This is a significant issue in the context of AF, because accurate characterization of fibrillatory waves (f-waves) is unavoidably required to improve current knowledge about its mechanisms. This work introduces a new algorithm able to reduce high levels of PLI and preserve, simultaneously, the original ECG morphology. Approach: The method is based on stationary wavelet transform shrinking and makes use of a new thresholding function designed to work successfully in a wide variety of scenarios. In fact, it has been validated in a general context with 48 ECG recordings obtained from pathological and non-pathological conditions, as well as in the particular context of AF, where 380 synthesized and 20 long-term real ECG recordings were analyzed. Main results: In both situations, the algorithm has reported a notably better performance than common methods designed for the same purpose. Moreover, its effectiveness has proven to be optimal for dealing with ECG recordings affected by AF, since f-waves remained almost intact after removing very high levels of noise. Significance: The proposed algorithm may facilitate a reliable characterization of the f-waves, preventing them from not being masked by the PLI nor distorted by an unsuitable filtering applied to ECG recordings with AF."
- Open Access
Novel Entropy-Based Metrics for Long-Term Atrial Fibrillation Recurrence Prediction Following Surgical Ablation: Insights from Preoperative Electrocardiographic Analysis
Atrial fibrillation (AF) is a prevalent cardiac arrhythmia often treated concomitantly with other cardiac interventions through the Cox–Maze procedure. This highly invasive intervention is still linked to a long-term recurrence rate of approximately 35% in permanent AF patients. The aim of this study is to preoperatively predict long-term AF recurrence post-surgery through the analysis of atrial activity (AA) organization from non-invasive electrocardiographic (ECG) recordings. A dataset comprising ECGs from 53 patients with permanent AF who had undergone Cox–Maze concomitant surgery was analyzed. The AA was extracted from the lead V1 of these recordings and then characterized using novel predictors, such as the mean and standard deviation of the relative wavelet energy ( and ) across different scales, and an entropy-based metric that computes the stationary wavelet entropy variability (). The individual predictors exhibited limited predictive capabilities to anticipate the outcome of the procedure, with the yielding a classification accuracy (Acc) of 68.07%. However, the assessment of the for the seventh scale (), which encompassed frequencies associated with the AA, stood out as the most promising individual predictor, with sensitivity (Se) and specificity (Sp) values of 80.83% and 67.09%, respectively, and an Acc of almost 75%. Diverse multivariate decision tree-based models were constructed for prediction, giving priority to simplicity in the interpretation of the forecasting methodology. In fact, the combination of the and consistently outperformed the individual predictors and excelled in predicting post-surgery outcomes one year after the Cox–Maze procedure, with Se, Sp, and Acc values of approximately 80%, thus surpassing the results of previous studies based on anatomical predictors associated with atrial function or clinical data. These findings emphasize the crucial role of preoperative patient-specific ECG signal analysis in tailoring post-surgical care, enhancing clinical decision making, and improving long-term clinical outcomes.Open AccessNovel Entropy-Based Metrics for Long-Term Atrial Fibrillation Recurrence Prediction Following Surgical Ablation: Insights from Preoperative Electrocardiographic Analysis
Atrial fibrillation (AF) is a prevalent cardiac arrhythmia often treated concomitantly with other cardiac interventions through the Cox–Maze procedure. This highly invasive intervention is still linked to a long-term recurrence rate of approximately 35% in permanent AF patients. The aim of this study is to preoperatively predict long-term AF recurrence post-surgery through the analysis of atrial activity (AA) organization from non-invasive electrocardiographic (ECG) recordings. A dataset comprising ECGs from 53 patients with permanent AF who had undergone Cox–Maze concomitant surgery was analyzed. The AA was extracted from the lead V1 of these recordings and then characterized using novel predictors, such as the mean and standard deviation of the relative wavelet energy ( and ) across different scales, and an entropy-based metric that computes the stationary wavelet entropy variability (). The individual predictors exhibited limited predictive capabilities to anticipate the outcome of the procedure, with the yielding a classification accuracy (Acc) of 68.07%. However, the assessment of the for the seventh scale (), which encompassed frequencies associated with the AA, stood out as the most promising individual predictor, with sensitivity (Se) and specificity (Sp) values of 80.83% and 67.09%, respectively, and an Acc of almost 75%. Diverse multivariate decision tree-based models were constructed for prediction, giving priority to simplicity in the interpretation of the forecasting methodology. In fact, the combination of the and consistently outperformed the individual predictors and excelled in predicting post-surgery outcomes one year after the Cox–Maze procedure, with Se, Sp, and Acc values of approximately 80%, thus surpassing the results of previous studies based on anatomical predictors associated with atrial function or clinical data. These findings emphasize the crucial role of preoperative patient-specific ECG signal analysis in tailoring post-surgical care, enhancing clinical decision making, and improving long-term clinical outcomes. - Open Access
- 14 October 2022
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 12 (10) , 1721
Preoperative Prediction of Catheter Ablation Outcome in Persistent Atrial Fibrillation Patients through Spectral Organization Analysis of the Surface Fibrillatory Waves
Catheter ablation (CA) is a commonly used treatment for persistent atrial fibrillation (AF). Since its medium/long-term success rate remains limited, preoperative prediction of its outcome is gaining clinical interest to optimally select candidates for the procedure. Among predictors based on the surface electrocardiogram, the dominant frequency (DF) and harmonic exponential decay () of the fibrillatory waves (f-waves) have reported promising but clinically insufficient results. Hence, the main goal of this work was to conduct a broader analysis of the f-wave harmonic spectral structure to improve CA outcome prediction through several entropy-based measures computed on different frequency bands. On a database of 151 persistent AF patients under radio-frequency CA and a follow-up of 9 months, the newly introduced parameters discriminated between patients who relapsed to AF and those who maintained SR at about 70%, which was statistically superior to the DF and approximately similar to . They also provided complementary information to through different combinations in multivariate models based on lineal discriminant analysis and report classification performance improvement of about 5%. These results suggest that the presence of larger harmonics and a proportionally smaller DF peak is associated with a decreased probability of AF recurrence after CA.- 14 October 2022
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 12 (10) , 1721
Open AccessPreoperative Prediction of Catheter Ablation Outcome in Persistent Atrial Fibrillation Patients through Spectral Organization Analysis of the Surface Fibrillatory Waves
Catheter ablation (CA) is a commonly used treatment for persistent atrial fibrillation (AF). Since its medium/long-term success rate remains limited, preoperative prediction of its outcome is gaining clinical interest to optimally select candidates for the procedure. Among predictors based on the surface electrocardiogram, the dominant frequency (DF) and harmonic exponential decay () of the fibrillatory waves (f-waves) have reported promising but clinically insufficient results. Hence, the main goal of this work was to conduct a broader analysis of the f-wave harmonic spectral structure to improve CA outcome prediction through several entropy-based measures computed on different frequency bands. On a database of 151 persistent AF patients under radio-frequency CA and a follow-up of 9 months, the newly introduced parameters discriminated between patients who relapsed to AF and those who maintained SR at about 70%, which was statistically superior to the DF and approximately similar to . They also provided complementary information to through different combinations in multivariate models based on lineal discriminant analysis and report classification performance improvement of about 5%. These results suggest that the presence of larger harmonics and a proportionally smaller DF peak is associated with a decreased probability of AF recurrence after CA. - 4 September 2020
- Published by Wiley in Computer Applications in Engineering Education
- Vol. 29 (4) , 911-930
Dynamic reconfiguration in FPAA for technical and nontechnical education in a global environment
Some engineering concepts have been proven to be very important not only in engineering degrees but in several areas. This knowledge is difficult to grasp under certain circumstances, and sometimes prior training is needed. This is a special challenge in full or part remote education. Simulations may help in this area, but truly experimental lab practices are crucial to grasp all the required knowledge and not only for fundamental information but for complex or indirect knowledge, where students can apply what they have learnt in classes. In this paper, we have worked on a concept to help professors and students to get new concepts in a more time‐efficient and safe manner, using dynamic reconfiguration in Field‐Programmable Analog Array. This solution can be easily applied to traditional or remote labs in less time than usual practices, so students can learn more in the same amount of time, especially when time is a constraint.
- 4 September 2020
- Published by Wiley in Computer Applications in Engineering Education
- Vol. 29 (4) , 911-930
Dynamic reconfiguration in FPAA for technical and nontechnical education in a global environment
Some engineering concepts have been proven to be very important not only in engineering degrees but in several areas. This knowledge is difficult to grasp under certain circumstances, and sometimes prior training is needed. This is a special challenge in full or part remote education. Simulations may help in this area, but truly experimental lab practices are crucial to grasp all the required knowledge and not only for fundamental information but for complex or indirect knowledge, where students can apply what they have learnt in classes. In this paper, we have worked on a concept to help professors and students to get new concepts in a more time‐efficient and safe manner, using dynamic reconfiguration in Field‐Programmable Analog Array. This solution can be easily applied to traditional or remote labs in less time than usual practices, so students can learn more in the same amount of time, especially when time is a constraint.
- 1 November 2018
- Published by IOP Publishing in Physiological Measurement
- Vol. 39 (11) , 115006
A novel wavelet-based filtering strategy to remove powerline interference from electrocardiograms with atrial fibrillation
Objective : The electrocardiogram (ECG) is currently the most widely used recording to diagnose cardiac disorders, including the most common supraventricular arrhythmia, such as atrial fibrillation (AF). However, different types of electrical disturbances, in which power-line interference (PLI) is a major problem, can mask and distort the original ECG morphology. This is a significant issue in the context of AF, because accurate characterization of fibrillatory waves ( f -waves) is unavoidably required to improve current knowledge about its mechanisms. This work introduces a new algorithm able to reduce high levels of PLI and preserve, simultaneously, the original ECG morphology. Approach : The method is based on stationary wavelet transform shrinking and makes use of a new thresholding function designed to work successfully in a wide variety of scenarios. In fact, it has been validated in a general context with 48 ECG recordings obtained from pathological and non-pathological conditions, as well as in the particular context of AF, where 380 synthesized and 20 long-term real ECG recordings were analyzed. Main results : In both situations, the algorithm has reported a notably better performance than common methods designed for the same purpose. Moreover, its effectiveness has proven to be optimal for dealing with ECG recordings affected by AF, since f -waves remained almost intact after removing very high levels of noise. Significance : The proposed algorithm may facilitate a reliable characterization of the f -waves, preventing them from not being masked by the PLI nor distorted by an unsuitable filtering applied to ECG recordings with AF.
- 1 November 2018
- Published by IOP Publishing in Physiological Measurement
- Vol. 39 (11) , 115006
A novel wavelet-based filtering strategy to remove powerline interference from electrocardiograms with atrial fibrillation
Objective : The electrocardiogram (ECG) is currently the most widely used recording to diagnose cardiac disorders, including the most common supraventricular arrhythmia, such as atrial fibrillation (AF). However, different types of electrical disturbances, in which power-line interference (PLI) is a major problem, can mask and distort the original ECG morphology. This is a significant issue in the context of AF, because accurate characterization of fibrillatory waves ( f -waves) is unavoidably required to improve current knowledge about its mechanisms. This work introduces a new algorithm able to reduce high levels of PLI and preserve, simultaneously, the original ECG morphology. Approach : The method is based on stationary wavelet transform shrinking and makes use of a new thresholding function designed to work successfully in a wide variety of scenarios. In fact, it has been validated in a general context with 48 ECG recordings obtained from pathological and non-pathological conditions, as well as in the particular context of AF, where 380 synthesized and 20 long-term real ECG recordings were analyzed. Main results : In both situations, the algorithm has reported a notably better performance than common methods designed for the same purpose. Moreover, its effectiveness has proven to be optimal for dealing with ECG recordings affected by AF, since f -waves remained almost intact after removing very high levels of noise. Significance : The proposed algorithm may facilitate a reliable characterization of the f -waves, preventing them from not being masked by the PLI nor distorted by an unsuitable filtering applied to ECG recordings with AF.
- Open Access
- 26 October 2017
- Published by Wiley in Complexity
- Vol. 2017, 1-13
Combined Nonlinear Analysis of Atrial and Ventricular Series for Automated Screening of Atrial Fibrillation
Atrial fibrillation (AF) is the most common cardiac arrhythmia in clinical practice. It often starts with asymptomatic and short episodes, which are difficult to detect without the assistance of automatic monitoring tools. The vast majority of methods proposed for this purpose are based on quantifying the irregular ventricular response (i.e., RR series) during the arrhythmia. However, although AF totally alters the atrial activity (AA) reflected on the electrocardiogram (ECG), replacing stable P-waves by chaotic and time-variant fibrillatory waves, this information has still not been explored for automated screening of AF. Hence, a pioneering AF detector based on quantifying the variability over time of the AA morphological pattern is here proposed. Results from two public reference databases have proven that the proposed method outperforms current state-of-the-art algorithms, reporting accuracy higher than 90%. A less false positive rate in the presence of other arrhythmias different from AF was also noticed. Finally, the combination of this algorithm with the classical analysis of RR series variability also yielded a promising trade-off between AF accuracy and detection delay. Indeed, this combination provided similar accuracy than RR-based methods, but with a significantly shorter delay of 10 beats.
- 26 October 2017
- Published by Wiley in Complexity
- Vol. 2017, 1-13
Open AccessCombined Nonlinear Analysis of Atrial and Ventricular Series for Automated Screening of Atrial Fibrillation
Atrial fibrillation (AF) is the most common cardiac arrhythmia in clinical practice. It often starts with asymptomatic and short episodes, which are difficult to detect without the assistance of automatic monitoring tools. The vast majority of methods proposed for this purpose are based on quantifying the irregular ventricular response (i.e., RR series) during the arrhythmia. However, although AF totally alters the atrial activity (AA) reflected on the electrocardiogram (ECG), replacing stable P-waves by chaotic and time-variant fibrillatory waves, this information has still not been explored for automated screening of AF. Hence, a pioneering AF detector based on quantifying the variability over time of the AA morphological pattern is here proposed. Results from two public reference databases have proven that the proposed method outperforms current state-of-the-art algorithms, reporting accuracy higher than 90%. A less false positive rate in the presence of other arrhythmias different from AF was also noticed. Finally, the combination of this algorithm with the classical analysis of RR series variability also yielded a promising trade-off between AF accuracy and detection delay. Indeed, this combination provided similar accuracy than RR-based methods, but with a significantly shorter delay of 10 beats.
- 1 July 2016
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 131, 157-168
Application of the relative wavelet energy to heart rate independent detection of atrial fibrillation
- 1 July 2016
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 131, 157-168
Application of the relative wavelet energy to heart rate independent detection of atrial fibrillation