Dassonville
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dassonville has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Corinne Mandin
French Authority for Nuclear Safety and Radiation Protection (ASNR), Fontenay-aux-Roses, France
2 shared publications C. Mandin
Univ Paris Est, CSTB, Direct Sante Confort, Observ Qualite Air Interieur, F-77447 Marne La Vallee 2, France
1 shared publication- Christophe Martinsons
Direction Santé, Ambiances et Mobilité, Centre Scientifique et Technique du Bâtiment (CSTB), 38400 Saint Martin d’Hères, France
1 shared publication - Claire de Labrusse
School of Health Sciences (HESAV) HES‐SO University of Applied Sciences and Arts Western Switzerland Lausanne Switzerland
1 shared publication - Guillaume Wyart
CSTB-Scientific and Technical Building Centre, Paris Est University, 84 Avenue Jean Jaurès, 77447 Marne la Vallée Cedex 2, France
1 shared publication - Jacques Ribéron
Département Santé et Confort, Centre Scientifique et Technique du Bâtiment (CSTB), 84 Avenue Jean Jaurès, Champs-sur-Marne, 77447 Marne-la-Vallée CEDEX 2, France
1 shared publication
Latest Publications
- 27 February 2024
- Published by Pelvic Obstetric and Gynaecological Physiotherapy in Journal of Pelvic, Obstetric and Gynaecological Physiotherapy
- Vol. 134, 42-52
Evaluation of a new management approach using a mobile application in the treatment of stress urinary incontinence in women
Pelvic floor muscle training (PFMT) is effective in the treatment of stress urinary incontinence (SUI). The aim of this randomized controlled trial was to investigate a new management approach involving the use of a mobile application (app) along with standard pelvic floor physiotherapy. The study included 30 female participants with SUI who were aged between 30 and 60 years. The women in the intervention group performed exercises at home using an app connected to an intravaginal probe. Those in the control group performed the same exercises using paper-based instructions. The period of the intervention was 3 months, and five parameters were analysed: adherence, compliance, SUI symptoms, pelvic floor functionality and quality of life (QOL). All participants received physiotherapy sessions in parallel with PFMT. The intervention group showed improvements in incontinence symptoms (P = 0.002), QOL (P = 0.003) and pelvic floor functionality over the course of treatment. Improvements in symptoms (P = 0.021), QOL (P = 0.008), and the strength and speed of contractions were observed in the control group. Intergroup tests only identified a significant difference for the PERFECT speed parameter (P = 0.011). A decrease in motivation was noted in both groups. This study did not show that an app connected to a probe was superior to paper-based instructions for PFMT. However, it did confirm that a home exercise programme combined with physiotherapy has a positive impact on SUI symptoms and QOL.
- 27 February 2024
- Published by Pelvic Obstetric and Gynaecological Physiotherapy in Journal of Pelvic, Obstetric and Gynaecological Physiotherapy
- Vol. 134, 42-52
Evaluation of a new management approach using a mobile application in the treatment of stress urinary incontinence in women
Pelvic floor muscle training (PFMT) is effective in the treatment of stress urinary incontinence (SUI). The aim of this randomized controlled trial was to investigate a new management approach involving the use of a mobile application (app) along with standard pelvic floor physiotherapy. The study included 30 female participants with SUI who were aged between 30 and 60 years. The women in the intervention group performed exercises at home using an app connected to an intravaginal probe. Those in the control group performed the same exercises using paper-based instructions. The period of the intervention was 3 months, and five parameters were analysed: adherence, compliance, SUI symptoms, pelvic floor functionality and quality of life (QOL). All participants received physiotherapy sessions in parallel with PFMT. The intervention group showed improvements in incontinence symptoms (P = 0.002), QOL (P = 0.003) and pelvic floor functionality over the course of treatment. Improvements in symptoms (P = 0.021), QOL (P = 0.008), and the strength and speed of contractions were observed in the control group. Intergroup tests only identified a significant difference for the PERFECT speed parameter (P = 0.011). A decrease in motivation was noted in both groups. This study did not show that an app connected to a probe was superior to paper-based instructions for PFMT. However, it did confirm that a home exercise programme combined with physiotherapy has a positive impact on SUI symptoms and QOL.
- Open Access
Review of Parameters Measured to Characterize Classrooms’ Indoor Environmental Quality
As attention to indoor environmental quality (IEQ) grows, a systematic strategy for assessing IEQ in schools needs to be developed. For this purpose, this paper presents a summary of parameters measured in school classrooms to characterize the quality of thermal, acoustic, and visual environments and indoor air quality (IAQ). The summary is based on a review of published literature reporting measurements in schools in Europe and North America in the past ten years. It also summarizes the measurement protocols and measured concentrations. Eighty-eight papers describing measurements in schools were identified and analyzed. No unique standardized measuring method was used in the reviewed studies and different parameters were measured. The most often measured parameters were those describing the thermal environment and IAQ. The former mainly comprised air temperature and relative humidity. The latter mainly comprised concentrations of carbon dioxide, particulate matter, radon, formaldehyde, and some volatile organic compounds. The measured parameters describing acoustic and visual environments mainly comprised noise level, reverberation time, and illuminance. A few studies reported additional measurements of radiant temperature, operative temperature, and speech intelligibility. Measurement protocols from different studies show inconsistency in sampling duration and location and expressed results. Measured concentrations also show high variation between studies, with some pollutants exceeding the threshold values proposed by local and/or international organizations such as the World Health Organization (WHO). This review provides the reference for developing a rating scheme and protocols for uniform characterization of classroom IEQ.
Open AccessReview of Parameters Measured to Characterize Classrooms’ Indoor Environmental Quality
As attention to indoor environmental quality (IEQ) grows, a systematic strategy for assessing IEQ in schools needs to be developed. For this purpose, this paper presents a summary of parameters measured in school classrooms to characterize the quality of thermal, acoustic, and visual environments and indoor air quality (IAQ). The summary is based on a review of published literature reporting measurements in schools in Europe and North America in the past ten years. It also summarizes the measurement protocols and measured concentrations. Eighty-eight papers describing measurements in schools were identified and analyzed. No unique standardized measuring method was used in the reviewed studies and different parameters were measured. The most often measured parameters were those describing the thermal environment and IAQ. The former mainly comprised air temperature and relative humidity. The latter mainly comprised concentrations of carbon dioxide, particulate matter, radon, formaldehyde, and some volatile organic compounds. The measured parameters describing acoustic and visual environments mainly comprised noise level, reverberation time, and illuminance. A few studies reported additional measurements of radiant temperature, operative temperature, and speech intelligibility. Measurement protocols from different studies show inconsistency in sampling duration and location and expressed results. Measured concentrations also show high variation between studies, with some pollutants exceeding the threshold values proposed by local and/or international organizations such as the World Health Organization (WHO). This review provides the reference for developing a rating scheme and protocols for uniform characterization of classroom IEQ.
- Open Access
- 5 November 2015
- Published by MDPI AG in Atmosphere
- Vol. 6 (11) , 1676-1694
Exposure Assessment of Allergens and Metals in Settled Dust in French Nursery and Elementary Schools
The aim of this study was to characterise the contamination in settled dust in French classrooms and to provide an overview of the influencing factors of dust contamination. Cat, dog and dust mite allergens and metals were measured in 51 classrooms at 17 schools. The concentrations of pet allergens in settled dust were generally low (mean value of 0.1 µg·g−1), with carpeted and rug-covered floors presenting higher dust and cat allergen concentrations. The highest metal loadings in dust were observed for manganese (Mn) and copper (Cu), while the lead (Pb) loadings were lower (16 ± 19 µg·m−2) and fell below the French guideline. Higher metal leachability was found for cadmium (Cd), Cu, Pb and strontium (Sr) at values of approximately 80%, which suggest that, in cases of dust ingestion by children, a large proportion should be assimilated through the gastro-intestinal tract. The intra-classroom and intra-school variabilities of the metal concentrations in settled dust were lower than the variability between schools. Classrooms with tiled floors had higher Pb loadings than classrooms with wood or vinyl floors. In addition, wet cleaning less than once a week resulted in greater loadings of Cu and Pb in the settled dust. Lastly, enrichment factors showed that metals in settled dust of classrooms were not only from the contribution of the natural background concentrations in soils.
- 5 November 2015
- Published by MDPI AG in Atmosphere
- Vol. 6 (11) , 1676-1694
Open AccessExposure Assessment of Allergens and Metals in Settled Dust in French Nursery and Elementary Schools
The aim of this study was to characterise the contamination in settled dust in French classrooms and to provide an overview of the influencing factors of dust contamination. Cat, dog and dust mite allergens and metals were measured in 51 classrooms at 17 schools. The concentrations of pet allergens in settled dust were generally low (mean value of 0.1 µg·g−1), with carpeted and rug-covered floors presenting higher dust and cat allergen concentrations. The highest metal loadings in dust were observed for manganese (Mn) and copper (Cu), while the lead (Pb) loadings were lower (16 ± 19 µg·m−2) and fell below the French guideline. Higher metal leachability was found for cadmium (Cd), Cu, Pb and strontium (Sr) at values of approximately 80%, which suggest that, in cases of dust ingestion by children, a large proportion should be assimilated through the gastro-intestinal tract. The intra-classroom and intra-school variabilities of the metal concentrations in settled dust were lower than the variability between schools. Classrooms with tiled floors had higher Pb loadings than classrooms with wood or vinyl floors. In addition, wet cleaning less than once a week resulted in greater loadings of Cu and Pb in the settled dust. Lastly, enrichment factors showed that metals in settled dust of classrooms were not only from the contribution of the natural background concentrations in soils.
- 1 December 2014
- Published by Elsevier in Archives des Maladies Professionnelles et de l'Environnement
- Vol. 75 (6) , 594-606
Pollutions à l’intérieur des espaces clos : sources, niveaux et impact sanitaire. Volet 2 : polluants chimiques
- 1 December 2014
- Published by Elsevier in Archives des Maladies Professionnelles et de l'Environnement
- Vol. 75 (6) , 594-606
Pollutions à l’intérieur des espaces clos : sources, niveaux et impact sanitaire. Volet 2 : polluants chimiques