Varatharajan Thirumurugan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Varatharajan Thirumurugan has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
K.S. Satyanarayanan
7 shared publicationsK. S. Satyanarayanan
Department of Civil Engineering, SRM Institute of Science and Technology, SRM Nagar, Kattankulathur, India
3 shared publications- K. S. Satyanarayanan
Department of Civil Engineering, SRM Institute of Science and Technology, Kattankulathur, India
3 shared publications M. Prakash
3 shared publicationsN. Parthasarathi
3 shared publications- A. Aziz Al-Ayoubi
Department of Civil Engineering, SRM Institute of Science and Technology, Kattankulathur, India
2 shared publications
Latest Publications
- 1 July 2025
- Published by Springer Nature in Asian Journal of Civil Engineering
- Vol. 26 (10) , 4203-4217
Seismic fragility analysis of elevated RC tanks based on IDA and machine learning
- 1 July 2025
- Published by Springer Nature in Asian Journal of Civil Engineering
- Vol. 26 (10) , 4203-4217
Seismic fragility analysis of elevated RC tanks based on IDA and machine learning
- 13 May 2025
- Published by Springer Nature in Asian Journal of Civil Engineering
- Vol. 26 (7) , 3007-3024
A machine learning framework for predicting seismic behavior in elevated reinforced concrete tanks
- 13 May 2025
- Published by Springer Nature in Asian Journal of Civil Engineering
- Vol. 26 (7) , 3007-3024
A machine learning framework for predicting seismic behavior in elevated reinforced concrete tanks
- Open Access
Pressure Optimization in Pneumatic Interfaces Using a Single-Bay Seven-Story Infilled Reinforced Concrete Frame: Experimental and Numerical Investigation
Reinforced concrete infilled frames have been studied over the years along with the infilled openings. To resist the lateral loads that are applied on the frames, stress is transferred from the reinforced concrete (RC) to infill, which leads to brittle collapse. The conventional interface medium, which was considered by researchers and recent studies, was prepared by changing the interface materials between the RC frame and infill panels to different elastic materials. This study focuses on optimizing the interface pressure using a butyl rubber tube, which reduces the stress distribution to the infill panel from the RC frame. A 50% window opening was adopted in this study, which is the optimized size from previous research. The optimization patterns followed linear and nonlinear patterns, such as the same pressures in all stories and varying pressures in all stories. The third story had a 8 PSI pattern and the other stories had a 2 PSI pattern; all stories with 8 PSI patterns achieved the least displacement when compared to other variations. A monotonic static analysis was performed for both the experimental and analytical study. The boundary conditions were pinned, and coupling interfaces were made for the master and slave surfaces. The pressure conditions were applied in various linear and nonlinear patterns to optimize the pressure. A comparative study was performed on the displacement, stiffness, and drift ratio for the critical position of the interface pressure in both the analytical and experimental studies. The difference was approximately 0.53% in the analytical study and 0.37% in the experimental work. The optimization was performed using both an experimental model and an analytical model, which had an error percentage of 0.61%.
Open AccessPressure Optimization in Pneumatic Interfaces Using a Single-Bay Seven-Story Infilled Reinforced Concrete Frame: Experimental and Numerical Investigation
Reinforced concrete infilled frames have been studied over the years along with the infilled openings. To resist the lateral loads that are applied on the frames, stress is transferred from the reinforced concrete (RC) to infill, which leads to brittle collapse. The conventional interface medium, which was considered by researchers and recent studies, was prepared by changing the interface materials between the RC frame and infill panels to different elastic materials. This study focuses on optimizing the interface pressure using a butyl rubber tube, which reduces the stress distribution to the infill panel from the RC frame. A 50% window opening was adopted in this study, which is the optimized size from previous research. The optimization patterns followed linear and nonlinear patterns, such as the same pressures in all stories and varying pressures in all stories. The third story had a 8 PSI pattern and the other stories had a 2 PSI pattern; all stories with 8 PSI patterns achieved the least displacement when compared to other variations. A monotonic static analysis was performed for both the experimental and analytical study. The boundary conditions were pinned, and coupling interfaces were made for the master and slave surfaces. The pressure conditions were applied in various linear and nonlinear patterns to optimize the pressure. A comparative study was performed on the displacement, stiffness, and drift ratio for the critical position of the interface pressure in both the analytical and experimental studies. The difference was approximately 0.53% in the analytical study and 0.37% in the experimental work. The optimization was performed using both an experimental model and an analytical model, which had an error percentage of 0.61%.
- Open Access
- 23 March 2023
- Published by MDPI AG in Journal of Composites Science
- Vol. 7 (4) , 132
Experimental Investigation on Flexural Behaviour of Sustainable Reinforced Concrete Beam with a Smart Mortar Layer
This paper deals with an experimental study of the flexural behavior of sustainable reinforced cement concrete (RCC) beams with a smart mortar layer attached to the concrete mixture. In total, nine RCC beams were cast and tested. Two types of reinforced concrete beams were cast, and three different beams of sizes 1000 × 150 × 200 mm and six different beams of sizes 1500 × 100 × 250 mm were considered. The flexural behavior of these RCC beams was studied in detail. The electrical resistivity of these beams was also calculated, which was derived from the smart mortar layer. Research on the application of smart mortars within structural members is limited. The experimental results showed that the smart mortar layer could sense the damage in the RCC beams and infer the damage through the electrical measurement values, making the beam more sustainable. It was also observed that the relationship between the load and the fractional change in electrical resistance was linear. The fractional change in electrical resistivity was found to steadily increase with the increase in initial loading. A significant decrease in the fractional change in electrical resistivity was seen as the load approached failure. When a layer of mortar with brass fiber was added to the mortar paste, the ultimate load at failure was observed and compared with the reference beam specimen using Araldite paste. Compared to the hybrid brass-carbon fiber-added mortar layer, the brass fiber-added mortar layer increased the fractional change in the electrical resistivity values by 14–18%. Similarly, the ultimate load at failure was increased by 3–8% in the brass fiber-added mortar layer when compared to the hybrid brass-carbon fiber-added mortar layer. Failure of the beam was indicated by a sudden drop in the fractional change in electrical resistivity values.
- 23 March 2023
- Published by MDPI AG in Journal of Composites Science
- Vol. 7 (4) , 132
Open AccessExperimental Investigation on Flexural Behaviour of Sustainable Reinforced Concrete Beam with a Smart Mortar Layer
This paper deals with an experimental study of the flexural behavior of sustainable reinforced cement concrete (RCC) beams with a smart mortar layer attached to the concrete mixture. In total, nine RCC beams were cast and tested. Two types of reinforced concrete beams were cast, and three different beams of sizes 1000 × 150 × 200 mm and six different beams of sizes 1500 × 100 × 250 mm were considered. The flexural behavior of these RCC beams was studied in detail. The electrical resistivity of these beams was also calculated, which was derived from the smart mortar layer. Research on the application of smart mortars within structural members is limited. The experimental results showed that the smart mortar layer could sense the damage in the RCC beams and infer the damage through the electrical measurement values, making the beam more sustainable. It was also observed that the relationship between the load and the fractional change in electrical resistance was linear. The fractional change in electrical resistivity was found to steadily increase with the increase in initial loading. A significant decrease in the fractional change in electrical resistivity was seen as the load approached failure. When a layer of mortar with brass fiber was added to the mortar paste, the ultimate load at failure was observed and compared with the reference beam specimen using Araldite paste. Compared to the hybrid brass-carbon fiber-added mortar layer, the brass fiber-added mortar layer increased the fractional change in the electrical resistivity values by 14–18%. Similarly, the ultimate load at failure was increased by 3–8% in the brass fiber-added mortar layer when compared to the hybrid brass-carbon fiber-added mortar layer. Failure of the beam was indicated by a sudden drop in the fractional change in electrical resistivity values.
- 22 March 2023
- Published by Springer Nature in Asian Journal of Civil Engineering
- Vol. 24 (7) , 2029-2047
Interface pressure optimization in a masonry-infilled single bay seven-storey RC frame with an adaptive pneumatic interface using ANN
- 22 March 2023
- Published by Springer Nature in Asian Journal of Civil Engineering
- Vol. 24 (7) , 2029-2047
Interface pressure optimization in a masonry-infilled single bay seven-storey RC frame with an adaptive pneumatic interface using ANN
- 23 February 2023
- Published by Springer Nature in Asian Journal of Civil Engineering
- Vol. 24 (7) , 1915-1925
Artificial neural network prediction of window openings and positions in reinforced concrete infilled frames with pneumatic interface
- 23 February 2023
- Published by Springer Nature in Asian Journal of Civil Engineering
- Vol. 24 (7) , 1915-1925
Artificial neural network prediction of window openings and positions in reinforced concrete infilled frames with pneumatic interface
- Open Access
- 23 November 2022
- Published by Elsevier in Case Studies in Construction Materials
- Vol. 17
Monitoring the behaviour of seven storeyed RC frame subjected to reversed cyclic loading by nonlinear NDT
- 23 November 2022
- Published by Elsevier in Case Studies in Construction Materials
- Vol. 17
Open AccessMonitoring the behaviour of seven storeyed RC frame subjected to reversed cyclic loading by nonlinear NDT
- Open Access
- 15 July 2022
- Published by MDPI AG in Journal of Composites Science
- Vol. 6 (7) , 208
An Experimental Study on Electrical Properties of Self-Sensing Mortar
Self-sensing cementitious composites are a combination of conventional materials used in the construction industry along with any type of electrically conductive filler material. Research has already been carried out with various types of conductive fillers incorporated into cement mortars to develop a self-sensing material. Carbon fibres have been used as conductive fillers in the past, which is uneconomical. In order to overcome this drawback, brass fibres have been introduced. This study concentrates on the behaviour of self-sensing mortar under two different curing conditions, including air and water curing. The main aim of this paper is to determine the self-sensing ability of various types of smart mortars. For this purpose, an experimental study was carried out, with the addition of various brass fibres of 0.10%, 0.15%, 0.20%, 0.25%, and 0.30% by volume, to determine the electrical properties of cementitious mortar. In addition, different combinations of brass and carbon fibres were considered, such as 95% brass fibre with 5% carbon fibre, 90% brass fibre with 10% carbon fibre, and 85% brass fibre with 15% carbon fibre by volume, to determine the piezoresistive behaviour. A fractional change in electrical resistance was determined for all the mortar cubes. A fractional change in electrical resistance (fcr) is defined as the change in its electrical resistance with respect to its initial resistance (ΔR/R). Additionally, the temperature effects on self-sensing mortar under compressive loading were observed for various temperatures from room temperature to 800 °C (at room temperature, 200 °C, 400 °C, 600 °C, and 800 °C). It was observed that the addition of brass fibre to the cement mortar as an electrically conductive filler improved the self-sensing ability of the mortar. After 28 days of water curing, when compared to conventional mortar, the percentage increase in change in electrical resistance (fcr) was observed to be 26.00%, 26.87%, 27.87%, 38.55%, and 35.00% for 0.10%, 0.15%, 0.20%, 0.25%, and 0.30% addition of brass fibres, respectively. When the smart mortar was exposed to elevated temperatures, the compressive strength of the mortar was reduced. Additionally, the fractional change in electrical resistance values was also reduced with the increase in temperature. In addition to this, the self-sensing ability of smart mortars showed improved performance in water curing rather than in air-cured mortars. Compressive strengths, stress, strain, and change in electrical resistance (fcr) values were determined in this study. Finally, microstructural analysis was also performed to determine the surface topography and chemical composition of the mortar with different fibre combinations.
- 15 July 2022
- Published by MDPI AG in Journal of Composites Science
- Vol. 6 (7) , 208
Open AccessAn Experimental Study on Electrical Properties of Self-Sensing Mortar
Self-sensing cementitious composites are a combination of conventional materials used in the construction industry along with any type of electrically conductive filler material. Research has already been carried out with various types of conductive fillers incorporated into cement mortars to develop a self-sensing material. Carbon fibres have been used as conductive fillers in the past, which is uneconomical. In order to overcome this drawback, brass fibres have been introduced. This study concentrates on the behaviour of self-sensing mortar under two different curing conditions, including air and water curing. The main aim of this paper is to determine the self-sensing ability of various types of smart mortars. For this purpose, an experimental study was carried out, with the addition of various brass fibres of 0.10%, 0.15%, 0.20%, 0.25%, and 0.30% by volume, to determine the electrical properties of cementitious mortar. In addition, different combinations of brass and carbon fibres were considered, such as 95% brass fibre with 5% carbon fibre, 90% brass fibre with 10% carbon fibre, and 85% brass fibre with 15% carbon fibre by volume, to determine the piezoresistive behaviour. A fractional change in electrical resistance was determined for all the mortar cubes. A fractional change in electrical resistance (fcr) is defined as the change in its electrical resistance with respect to its initial resistance (ΔR/R). Additionally, the temperature effects on self-sensing mortar under compressive loading were observed for various temperatures from room temperature to 800 °C (at room temperature, 200 °C, 400 °C, 600 °C, and 800 °C). It was observed that the addition of brass fibre to the cement mortar as an electrically conductive filler improved the self-sensing ability of the mortar. After 28 days of water curing, when compared to conventional mortar, the percentage increase in change in electrical resistance (fcr) was observed to be 26.00%, 26.87%, 27.87%, 38.55%, and 35.00% for 0.10%, 0.15%, 0.20%, 0.25%, and 0.30% addition of brass fibres, respectively. When the smart mortar was exposed to elevated temperatures, the compressive strength of the mortar was reduced. Additionally, the fractional change in electrical resistance values was also reduced with the increase in temperature. In addition to this, the self-sensing ability of smart mortars showed improved performance in water curing rather than in air-cured mortars. Compressive strengths, stress, strain, and change in electrical resistance (fcr) values were determined in this study. Finally, microstructural analysis was also performed to determine the surface topography and chemical composition of the mortar with different fibre combinations.
- 14 May 2022
- Published by Elsevier in Structures
- Vol. 41, 375-388
Progressive collapse evaluation of RC frames under high-temperature conditions: Experimental and finite element investigations
- 14 May 2022
- Published by Elsevier in Structures
- Vol. 41, 375-388
Progressive collapse evaluation of RC frames under high-temperature conditions: Experimental and finite element investigations
- 1 January 2022
- Published by Elsevier in Materials Today: Proceedings
- Vol. 50, 388-393
Experimental study on optimization of smart mortar with the addition of brass fibres
- 1 January 2022
- Published by Elsevier in Materials Today: Proceedings
- Vol. 50, 388-393
Experimental study on optimization of smart mortar with the addition of brass fibres