Alessandro Nilberto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alessandro Nilberto has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Edward Canepa
Department of Mechanical, Energy, Management and Transport Engineering, DIME, Università degli Studi di Genova, via Montallegro, 1, I-16145 Genova, Italy
3 shared publications - Andrea Bonfiglio
Department of Electrical, Electronic, Telecommunications Engineering and Naval Architecture, University of Genoa, 16126 Genoa, Italy
1 shared publication - Federico Delfino
Department of Electrical, Electronics and Telecommunication Engineering and Naval Architecture (DITEN), University of Genoa, Via Opera Pia 11a, 16145 Genoa, Italy
1 shared publication - Massimo Brignone
Department of Naval, Electrical, and ICT Engineering, University of Genova, I-16145 Genoa, Italy
1 shared publication - Renato Procopio
Department of Naval, Electronic, Electrical and Telecommunication Engineering, University of Genoa, Genoa, Italy
1 shared publication
Latest Publications
- Open Access
Experimental Flame Front Characterisation in a Lean Premix Burner Operating with Syngas Simplified Model Fuel
The recent growing attention to energy saving and environmental protection issues has brought attention to the possibility of exploiting syngas from gasification of biomass and coal for the firing of industrial plants included in the, so called, Integrated Gasification Combined Cycle power plants. In order to improve knowledge on the employ of syngas in lean premixed turbulent flames, a large scale swirl stabilized gas-turbine burner has been operated with a simplified model of H2 enriched syngas from coal gasification. The experimental campaign has been performed at atmospheric pressure, with operating conditions derived from scaling the real gas turbines. The results are reported here and consist of OH-PLIF (OH Planar Laser Induced Fluorescence) measurements, carried out at decreasing equivalence of air/fuel ratio conditions and analysed together with the mean aerodynamic characterisation of the burner flow field in isothermal conditions obtained through LDV (Laser Doppler Velocimetry) and PIV (Particle Image Velocimetry) measurements. The OH concentration distributions have been analysed statistically in order to obtain information about the location of the most reactive zones, and an algorithm has been applied to the data in order to identify the flame fronts. In addition, the flame front locations have been successively interpreted statistically to obtain information about their main features and their dependence on the air to fuel ratio behaviour.
Open AccessExperimental Flame Front Characterisation in a Lean Premix Burner Operating with Syngas Simplified Model Fuel
The recent growing attention to energy saving and environmental protection issues has brought attention to the possibility of exploiting syngas from gasification of biomass and coal for the firing of industrial plants included in the, so called, Integrated Gasification Combined Cycle power plants. In order to improve knowledge on the employ of syngas in lean premixed turbulent flames, a large scale swirl stabilized gas-turbine burner has been operated with a simplified model of H2 enriched syngas from coal gasification. The experimental campaign has been performed at atmospheric pressure, with operating conditions derived from scaling the real gas turbines. The results are reported here and consist of OH-PLIF (OH Planar Laser Induced Fluorescence) measurements, carried out at decreasing equivalence of air/fuel ratio conditions and analysed together with the mean aerodynamic characterisation of the burner flow field in isothermal conditions obtained through LDV (Laser Doppler Velocimetry) and PIV (Particle Image Velocimetry) measurements. The OH concentration distributions have been analysed statistically in order to obtain information about the location of the most reactive zones, and an algorithm has been applied to the data in order to identify the flame fronts. In addition, the flame front locations have been successively interpreted statistically to obtain information about their main features and their dependence on the air to fuel ratio behaviour.
- Open Access
- 16 April 2019
- Published by MDPI AG in Preprints.org
Experimental Flame Front Characterisation in a Lean Premix Burner Operating with Syngas Simplified Model
The recent growing attention to energy saving and environmental protection issues has brought to attention the possibility of exploiting syngas from gasification of biomass and coal for the firing of industrial plants included the so called Integrated Gasification Combined Cycle ones. In order to improve the knowledge about the employ of syngas in lean premixed turbulent flames, a large scale swirl stabilized gas-turbine burner has been operated with a simplified model of H2 enriched syngas from coal gasification. The experimental campaign has been performed at atmospheric pressure with operating conditions derived from scaling the real gas turbines ones. The results are here reported and consist of OH-PLIF measurements carried out at decreasing air equivalence ratio conditions and are analysed together with the mean aerodynamic characterisation of the burner flowfield in isothermal condition. The OH concentration distributions have been analysed statistically in order to obtain information about the location of the most reactive zones and an algorithm has been applied to the data in order to identify the flame fronts. In addition, the flame front locations have been successively interpreted statistically in order to obtain information about their main features and about their dependence on the air to fuel ratio behaviour.
- 16 April 2019
- Published by MDPI AG in Preprints.org
Open AccessExperimental Flame Front Characterisation in a Lean Premix Burner Operating with Syngas Simplified Model
The recent growing attention to energy saving and environmental protection issues has brought to attention the possibility of exploiting syngas from gasification of biomass and coal for the firing of industrial plants included the so called Integrated Gasification Combined Cycle ones. In order to improve the knowledge about the employ of syngas in lean premixed turbulent flames, a large scale swirl stabilized gas-turbine burner has been operated with a simplified model of H2 enriched syngas from coal gasification. The experimental campaign has been performed at atmospheric pressure with operating conditions derived from scaling the real gas turbines ones. The results are here reported and consist of OH-PLIF measurements carried out at decreasing air equivalence ratio conditions and are analysed together with the mean aerodynamic characterisation of the burner flowfield in isothermal condition. The OH concentration distributions have been analysed statistically in order to obtain information about the location of the most reactive zones and an algorithm has been applied to the data in order to identify the flame fronts. In addition, the flame front locations have been successively interpreted statistically in order to obtain information about their main features and about their dependence on the air to fuel ratio behaviour.
- Open Access
- 10 December 2018
- Published by MDPI AG in Preprints.org
Experimental Flame Front Characterisation in a Lean Premix Burner Operating at Syngas
The recent growing attention to energy saving and environmental protection issues has brought to attention the possibility of exploiting syngas from gasification of biomass and coal for the firing of industrial plants included the so called Integrated Gasification Combined Cycle ones. In order to acquire a detailed knowledge about the behaviour of lean turbulent premixed flames, the present work resent the results of an experimental characterisation of a prototypical gas turbine burner operated at atmospheric pressure at condition scaled from real gas turbines ones. The results here presented derive from OH-PLIF measurements carried out at decreasing air equivalence ratio conditions and are analysed together with a mean aerodynamic characterisation of the burner operating in isothermal condition. The OH concentration distributions have been analysed statistically in order to obtain information about the location of the most reactive zones and an algorithm has been applied to the data sets in order to identify the flame fronts. In addition, the flame front locations have been successively interpreted statistically in order to obtain information about their main features and about their dependence on the air to fuel ratio behaviour.
- 10 December 2018
- Published by MDPI AG in Preprints.org
Open AccessExperimental Flame Front Characterisation in a Lean Premix Burner Operating at Syngas
The recent growing attention to energy saving and environmental protection issues has brought to attention the possibility of exploiting syngas from gasification of biomass and coal for the firing of industrial plants included the so called Integrated Gasification Combined Cycle ones. In order to acquire a detailed knowledge about the behaviour of lean turbulent premixed flames, the present work resent the results of an experimental characterisation of a prototypical gas turbine burner operated at atmospheric pressure at condition scaled from real gas turbines ones. The results here presented derive from OH-PLIF measurements carried out at decreasing air equivalence ratio conditions and are analysed together with a mean aerodynamic characterisation of the burner operating in isothermal condition. The OH concentration distributions have been analysed statistically in order to obtain information about the location of the most reactive zones and an algorithm has been applied to the data sets in order to identify the flame fronts. In addition, the flame front locations have been successively interpreted statistically in order to obtain information about their main features and about their dependence on the air to fuel ratio behaviour.
- Open Access
Definition and Experimental Validation of a Simplified Model for a Microgrid Thermal Network and its Integration into Energy Management Systems
The present paper aims at defining a simplified but effective model of a thermal network that links the thermal power generation with the resulting temperature time profile in a heated or refrigerated environment. For this purpose, an equivalent electric circuit is proposed together with an experimental procedure to evaluate its input parameters. The paper also highlights the simplicity of implementation of the proposed model into a microgrid Energy Management System. This allows the optimal operation of the thermal network to be achieved on the basis of available data (desired temperature profile) instead of a less realistic basis (such as the desired thermal power profile). The validation of the proposed model is performed on the Savona Campus Smart Polygeneration Microgrid (SPM) with the following steps: (i) identification of the parameters involved in the equivalent circuit (performed by minimizing the difference between the temperature profile, as calculated with the proposed model, and the measured one in a set of training days); (ii) test of the model accuracy on a set of testing days (comparing the measured temperature profiles with the calculated ones); (iii) implementation of the model into an Energy Management System in order to optimize the thermal generation starting from a desired temperature hourly profile.
Open AccessDefinition and Experimental Validation of a Simplified Model for a Microgrid Thermal Network and its Integration into Energy Management Systems
The present paper aims at defining a simplified but effective model of a thermal network that links the thermal power generation with the resulting temperature time profile in a heated or refrigerated environment. For this purpose, an equivalent electric circuit is proposed together with an experimental procedure to evaluate its input parameters. The paper also highlights the simplicity of implementation of the proposed model into a microgrid Energy Management System. This allows the optimal operation of the thermal network to be achieved on the basis of available data (desired temperature profile) instead of a less realistic basis (such as the desired thermal power profile). The validation of the proposed model is performed on the Savona Campus Smart Polygeneration Microgrid (SPM) with the following steps: (i) identification of the parameters involved in the equivalent circuit (performed by minimizing the difference between the temperature profile, as calculated with the proposed model, and the measured one in a set of training days); (ii) test of the model accuracy on a set of testing days (comparing the measured temperature profiles with the calculated ones); (iii) implementation of the model into an Energy Management System in order to optimize the thermal generation starting from a desired temperature hourly profile.