Zebin Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zebin Zhu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Guanhao Wu
State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, China
7 shared publications Kai Ni
Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
4 shared publicationsQian Zhou
Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
4 shared publicationsGuangyao Xu
Department of Precision Instrument, State Key Laboratory of Precision Measurement Technology and Instruments, Beijing, CHINA
2 shared publicationsShilin Xiong
2 shared publicationsGuanhao Wu
State Key Laboratory of Precision Measurement Technology and Instruments Tsinghua- Foxconn Nanotechnology Research Center, Tsinghua University, Room 3211, Department of Precision Instruments, Tsinghua University , Beijing, 100084, Beijing, CHINA
1 shared publication
Latest Publications
- 7 November 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (23) , 34269-34283
Static pure strain sensing using dual–comb spectroscopy with FBG sensors
We propose a method to precisely characterize the optical response of a fiber Bragg grating (FBG) sensor for static strain sensing by using dual–comb spectroscopy (DCS). By digitally post–correcting the mutual noise between the two combs, a robust and pure strain sensing system is achieved by compensating for the temperature–induced frequency shift of the FBG sensor. The comb–resolved radio–frequency (RF) spectra generated by DCS are obtained. Meanwhile, the stability of the central Bragg frequency of the FBG–reflected spectrum in the RF domain is 0.315 kHz, which is better than the difference of repetition rate (1 kHz). A reference FBG is used for detecting and compensating for the temperature–induced central frequency drift. Finally, a spectral sensitivity of 0.85 pm/µɛ with 0.8 µɛ static strain resolution is achieved.
- 7 November 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (23) , 34269-34283
Static pure strain sensing using dual–comb spectroscopy with FBG sensors
We propose a method to precisely characterize the optical response of a fiber Bragg grating (FBG) sensor for static strain sensing by using dual–comb spectroscopy (DCS). By digitally post–correcting the mutual noise between the two combs, a robust and pure strain sensing system is achieved by compensating for the temperature–induced frequency shift of the FBG sensor. The comb–resolved radio–frequency (RF) spectra generated by DCS are obtained. Meanwhile, the stability of the central Bragg frequency of the FBG–reflected spectrum in the RF domain is 0.315 kHz, which is better than the difference of repetition rate (1 kHz). A reference FBG is used for detecting and compensating for the temperature–induced central frequency drift. Finally, a spectral sensitivity of 0.85 pm/µɛ with 0.8 µɛ static strain resolution is achieved.
- 26 July 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (16) , 22868-22876
Simplified phase-stable dual-comb interferometer for short dynamic range distance measurement
A simplified phase-stable dual-comb interferometer for absolute distance measurement within a short dynamic range is proposed in this paper. The experimental results demonstrate that stable phase-difference information and lower timing jitter can be obtained within a time delay of 2000 ns between the reference interference signal and measurement interference signal. Using the proposed technique, the time-of-flight (TOF) result can link directly to the carrier-wave interferometric (CWI) result in an average time of 20 ms and can reach 2 nm precision in 0.5 s averaging time. Millimeter-scale measurement dynamic range and nanometer-level precision can thus be achieved without additional noise suppression. This method can also be applied at different stand-off distances.
- 26 July 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (16) , 22868-22876
Simplified phase-stable dual-comb interferometer for short dynamic range distance measurement
A simplified phase-stable dual-comb interferometer for absolute distance measurement within a short dynamic range is proposed in this paper. The experimental results demonstrate that stable phase-difference information and lower timing jitter can be obtained within a time delay of 2000 ns between the reference interference signal and measurement interference signal. Using the proposed technique, the time-of-flight (TOF) result can link directly to the carrier-wave interferometric (CWI) result in an average time of 20 ms and can reach 2 nm precision in 0.5 s averaging time. Millimeter-scale measurement dynamic range and nanometer-level precision can thus be achieved without additional noise suppression. This method can also be applied at different stand-off distances.
- 8 February 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (4) , 4660-4671
Two-color phase-stable dual-comb ranging without precise environmental sensing
High-precision long geometrical distance measurement performs a vital role in large-scale manufacturing and future light detection and ranging (LIDAR) for tight formation. Its high precision, fast measurement rate, and large ambiguity range have traditionally made dual-comb ranging (DCR) a powerful tool for absolute distance measurement. However, DCR experiences the same issues caused by the refractive index of air as other laser-based ranging systems. The conventional method used to compensate refractive index of air is through using empirical equations by monitoring environment parameters. This real-time compensation method relies on precise sensors and cannot be easily applied to long-distance measurement. Thus, a two-color compensation method is proposed that requires only two co-propagating lights at different wavelengths, without specific identification of the refractive index of air. In this paper, the two-color method is combined with a low-noise DCR realized by a digital correction method. Mode resolved and phase-stable comb spectra are available for ranging at both two wavelengths with ~200 THz difference. The experimental result demonstrates 46 nm precision and 2.7 m ambiguity range by two-color DCR (TC-DCR) with 0.1 s coherent averaging at 1 kHz repetition rate difference. This method achieves a precision of the order of ~10−8 and an accuracy of the order of ~10−7, which is comparable to the single-color DCR results by empirical equations with environmental sensing. The proposed two-color DCR demonstrates great potential for long-distance measurement in open air.
- 8 February 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (4) , 4660-4671
Two-color phase-stable dual-comb ranging without precise environmental sensing
High-precision long geometrical distance measurement performs a vital role in large-scale manufacturing and future light detection and ranging (LIDAR) for tight formation. Its high precision, fast measurement rate, and large ambiguity range have traditionally made dual-comb ranging (DCR) a powerful tool for absolute distance measurement. However, DCR experiences the same issues caused by the refractive index of air as other laser-based ranging systems. The conventional method used to compensate refractive index of air is through using empirical equations by monitoring environment parameters. This real-time compensation method relies on precise sensors and cannot be easily applied to long-distance measurement. Thus, a two-color compensation method is proposed that requires only two co-propagating lights at different wavelengths, without specific identification of the refractive index of air. In this paper, the two-color method is combined with a low-noise DCR realized by a digital correction method. Mode resolved and phase-stable comb spectra are available for ranging at both two wavelengths with ~200 THz difference. The experimental result demonstrates 46 nm precision and 2.7 m ambiguity range by two-color DCR (TC-DCR) with 0.1 s coherent averaging at 1 kHz repetition rate difference. This method achieves a precision of the order of ~10−8 and an accuracy of the order of ~10−7, which is comparable to the single-color DCR results by empirical equations with environmental sensing. The proposed two-color DCR demonstrates great potential for long-distance measurement in open air.
- Open Access
- 1 December 2018
- Published by Elsevier in Engineering
- Vol. 4 (6) , 772-778
Dual-Comb Ranging
- 1 December 2018
- Published by Elsevier in Engineering
- Vol. 4 (6) , 772-778
Open AccessDual-Comb Ranging
- 15 June 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (13) , 16813-16823
Digital correction method for realizing a phase-stable dual-comb interferometer
A phase-stable dual-comb interferometer measures materials’ broadband optical response functions, including amplitude, frequency, and phase, making it a powerful tool for optical metrology. Normally, the phase-stable dual-comb interferometer is realized via tight phase-locking methods. This paper presents a post-correction algorithm that can compensate for carrier wave phase noise and interferogram timing jitter. The compensating signal is a beat between two combs using a free-running continuous wave laser as an optical intermediary. In our experiment, sub-hertz relative linewidth, ~1 ns relative timing jitter, and 0.2 rad precision in the carrier phase is demonstrated.
- 15 June 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (13) , 16813-16823
Digital correction method for realizing a phase-stable dual-comb interferometer
A phase-stable dual-comb interferometer measures materials’ broadband optical response functions, including amplitude, frequency, and phase, making it a powerful tool for optical metrology. Normally, the phase-stable dual-comb interferometer is realized via tight phase-locking methods. This paper presents a post-correction algorithm that can compensate for carrier wave phase noise and interferogram timing jitter. The compensating signal is a beat between two combs using a free-running continuous wave laser as an optical intermediary. In our experiment, sub-hertz relative linewidth, ~1 ns relative timing jitter, and 0.2 rad precision in the carrier phase is demonstrated.
- Open Access
- 12 March 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-7
Synthetic wavelength interferometry of an optical frequency comb for absolute distance measurement
We present a synthetic-wavelength based heterodyne interferometer of optical frequency combs with wide consecutive measurement range for absolute distance measurement. The synthetic wavelength is derived from two wavelengths obtained by two band-pass filters. The interferometric phase of the synthetic wavelength is used as a marker for the pulse-to-pulse alignment, which greatly improves the accuracy of traditional peak finding method. The consecutive measurement range is enlarged by using long fiber to increase the path length difference of the reference and measurement arms. The length of the long fiber is stabilized according to the interferometric phase of a CW laser. The experimental results show the present system can realize an accuracy of 75 nm in 350 mm consecutive measurement range.
- 12 March 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-7
Open AccessSynthetic wavelength interferometry of an optical frequency comb for absolute distance measurement
We present a synthetic-wavelength based heterodyne interferometer of optical frequency combs with wide consecutive measurement range for absolute distance measurement. The synthetic wavelength is derived from two wavelengths obtained by two band-pass filters. The interferometric phase of the synthetic wavelength is used as a marker for the pulse-to-pulse alignment, which greatly improves the accuracy of traditional peak finding method. The consecutive measurement range is enlarged by using long fiber to increase the path length difference of the reference and measurement arms. The length of the long fiber is stabilized according to the interferometric phase of a CW laser. The experimental results show the present system can realize an accuracy of 75 nm in 350 mm consecutive measurement range.
- 6 March 2018
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (4) , 045007
Improving the accuracy of a dual-comb interferometer by suppressing the relative linewidth
We present a compact system of synchronization for two fiber-based optical frequency comb lasers. We use a free-running continuous wave laser as an intermediary to obtain the relative noise of two combs and employ an intra-cavity electro-optic modulator (EOM) to achieve active phase feedback for fast synchronization. The EOM bandwidth is 150 kHz and the relative linewidth is suppressed markedly from 300 kHz to sub-hertz values. The relative effective timing jitter of the two pulse trains is also decreased from 680 fs to 25 fs. The proposed method shows promise for developing a high-performance, low-cost, fiber-based dual-comb interferometer for ranging or spectroscopy.
- 6 March 2018
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (4) , 045007
Improving the accuracy of a dual-comb interferometer by suppressing the relative linewidth
We present a compact system of synchronization for two fiber-based optical frequency comb lasers. We use a free-running continuous wave laser as an intermediary to obtain the relative noise of two combs and employ an intra-cavity electro-optic modulator (EOM) to achieve active phase feedback for fast synchronization. The EOM bandwidth is 150 kHz and the relative linewidth is suppressed markedly from 300 kHz to sub-hertz values. The relative effective timing jitter of the two pulse trains is also decreased from 680 fs to 25 fs. The proposed method shows promise for developing a high-performance, low-cost, fiber-based dual-comb interferometer for ranging or spectroscopy.
- 26 February 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (5) , 5747-5757
Synthetic-wavelength-based dual-comb interferometry for fast and precise absolute distance measurement
We present an absolute distance measurement system using a phase-stable dual-comb system with 56.09 MHz repetition rate and 2 kHz repetition rate difference. A relative phase stability of 0.1 rad in 0.5 ms between two combs is achieved using a mutual locking scheme. The dual-comb ranging system combines the time-of-flight (TOF) method, synthetic-wavelength interferometry (SWI), and carrier wave interferometry (CWI). Each method provides a particular ambiguity range and resolution, and they can be applied simultaneously and linked to enhance the precision and measurement rate of the ranging system. The experimental results demonstrate that a precision of 1.2 μm is obtained without time averaging, and the precision can be improved to 3 nm with only 10 ms averaging time using the SWI method described in this study. The precision reaches a sub-nanometer when the averaging time exceeds 0.1 s. A system with high accuracy and short averaging time would enhance fast measurement performance in various industrial applications. The ambiguity range is about 2.67 m in our system, we test the performance of the system with 1.5 mm range at 1.5 m distance.
- 26 February 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (5) , 5747-5757
Synthetic-wavelength-based dual-comb interferometry for fast and precise absolute distance measurement
We present an absolute distance measurement system using a phase-stable dual-comb system with 56.09 MHz repetition rate and 2 kHz repetition rate difference. A relative phase stability of 0.1 rad in 0.5 ms between two combs is achieved using a mutual locking scheme. The dual-comb ranging system combines the time-of-flight (TOF) method, synthetic-wavelength interferometry (SWI), and carrier wave interferometry (CWI). Each method provides a particular ambiguity range and resolution, and they can be applied simultaneously and linked to enhance the precision and measurement rate of the ranging system. The experimental results demonstrate that a precision of 1.2 μm is obtained without time averaging, and the precision can be improved to 3 nm with only 10 ms averaging time using the SWI method described in this study. The precision reaches a sub-nanometer when the averaging time exceeds 0.1 s. A system with high accuracy and short averaging time would enhance fast measurement performance in various industrial applications. The ambiguity range is about 2.67 m in our system, we test the performance of the system with 1.5 mm range at 1.5 m distance.