ASAlexandru Serban

Alexandru Serban

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alexandru Serban has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimization of Cryogenic Gas Separation Systems Based on Exergetic Analysis—The Claude–Heylandt Cycle for Oxygen Separation

    by Dănuț-Cristian Urduza, Lavinia Grosu, Alexandru Serban, Adalia Andreea Percembli (Chelmuș), Alexandru Dobrovicescu

    In cryogenic air liquefaction systems, a major share of the mechanical energy consumption is associated with exergy destruction caused by heat transfer in recuperative heat exchangers. This study investigated the exergetic optimization of cryogenic gas separation systems by focusing on the Claude–Heylandt cycle as an advanced structural modification of the classical Linde–Hampson scheme. An exergy-based analysis demonstrates that minimizing mechanical energy consumption requires a progressive reduction in the temperature difference between the hot forward stream and the cold returning stream toward the cold end of the heat exchanger. This condition was achieved by extracting a fraction of the high-pressure stream and expanding it in a parallel expander, thereby creating a controlled imbalance in the heat capacities between the two streams. The proposed configuration reduces the share of exergy destruction associated with heat transfer in the recuperative heat exchanger from 14% to 3.5%, leading to a fourfold increase in the exergetic efficiency, together with a 3.6-fold increase in the liquefied air fraction compared with the Linde–Hampson cycle operating under identical conditions. The effects of key decision parameters, including the compression pressure, imposed temperature differences, and expander inlet temperature, were systematically analyzed. The study was further extended by integrating an air separation column into the Claude–Heylandt cycle and optimizing its configuration based on entropy generation minimization. The optimal liquid-air feeding height and threshold number of rectification trays were identified, beyond which further structural complexity yielded no thermodynamic benefit. The results highlight the effectiveness of exergy-based optimization as a unified design criterion for both cryogenic liquefaction and separation processes.

  • Open Access

    Evolution of Colorimetry in 3D-Printed Samples Exposed to External Weather Conditions, Used in Smart Façades

    by Dan-Radu Baraboi, Gabriel Năstase, Răzvan Sima, Alexandru Șerban

    The successful deployment of 3D printing in outdoor applications is contingent upon the selection of materials capable of withstanding the degrading effects of weather. This study evaluates the colorimetric performance of various 3D-printed polymers exposed to natural weathering conditions in Brasov, Romania, from November 2024 to March 2025. Color changes were monitored through spectrophotometry using a PCE-XXM 20 color meter, and data were recorded in the LAB color space. The results indicate substantial differences in color stability among the tested materials, with some exhibiting unacceptable levels of fading and discoloration. These findings have significant implications for the design and implementation of outdoor 3D-printed products in climates analogous to that of Brasov, underscoring the importance of selecting materials with demonstrated resistance to weathering and color change.


  • Open Access

    Structural Optimization of Cryogenic Gas Liquefaction Based on Exergetic Principles—The Linde–Hampson Cycle

    by Dănuț Cristian Urduza, Lavinia Grosu, Adalia Andreea Percembli (Chelmuș), Alexandru Șerban, Alexandru Dobrovicescu

    Air liquefaction systems are essential in cryogenic engineering and energy storage, yet their performance is often constrained by significant exergy destruction. This study develops an exergy-based assessment of the Linde–Hampson air liquefaction cycle to identify dominant sources of inefficiency and explore strategies for improvement. The analysis shows that throttling (≈41%) and compression (≈40%) represent the major contributions to exergy losses, followed by finite-temperature heat transfer (≈15%) in the recuperative heat exchanger. To mitigate these losses, fractional throttling and optimized inlet conditions are proposed, leading to reduced compressor work and improved overall efficiency. A comparative study of a two-stage throttling configuration demonstrates a decrease in throttling-related exergy destruction to approximately 30%. Reverse Pinch analysis is employed to verify the thermal coupling of hot and cold streams and to determine the minimum feasible temperature difference. The design optimization of the recuperative heat exchanger identifies an optimal velocity ratio that minimizes pressure losses and quantifies how compression pressure affects the required heat transfer surface area. The results provide a systematic framework for improving the thermodynamic performance of air liquefaction cycles, highlighting exergy analysis as a powerful tool for guiding structural modifications and functional optimization.


  • Open Access

    Isochoric Supercooling Organ Preservation System

    by Gabriel Năstase, Florin Botea, George-Andrei Beșchea, Ștefan-Ioan Câmpean, Alexandru Barcu, Ion Neacșu, Vlad Herlea, Irinel Popescu, Tammy T. Chang, Boris Rubinsky, et al.

    This technical paper introduces a novel organ preservation system based on isochoric (constant volume) supercooling. The system is designed to enhance the stability of the metastable supercooling state, offering potential long-term preservation of large biological organs at subfreezing temperatures without the need for cryoprotectant additives. Detailed technical designs and usage protocols are provided for researchers interested in exploring this field. The paper also presents a control system based on the thermodynamics of isochoric freezing, utilizing pressure monitoring for process control. Sham experiments were performed using whole pig liver sourced from a local food supplier to evaluate the system’s ability to sustain supercooling without ice nucleation for extended periods. The results demonstrated sustained supercooling without ice nucleation in pig liver tissue for 24 and 48 h. These findings suggest the potential of this technology for large-volume, cryoprotectant-free organ preservation with real-time control over the preservation process. The simplicity of the isochoric supercooling device and the design details provided in the paper are expected to serve as encouragement for other researchers in the field to pursue further research on isochoric supercooling. However, final evidence that these preserved organs can be successfully transplanted is still lacking.


  • Open Access

    New Perspective on Performances and Limits of Solar Fresh Air Cooling in Different Climatic Conditions

    by Ancuta C. Abrudan, Octavian G. Pop, Alexandru Serban, Mugur C. Balan

    The study carried out by simulation, concerns the thermal behavior of an office building’s solar fresh air cooling system, based on a LiBr-H2O absorption chiller in different climatic conditions. The coefficient of performance (COP) and the solar fraction were considered performance parameters and were analyzed with respect to the operating limits—the risk of crystallization and maintaining at least a minimum degassing zone. A new correlation between the required solar hot temperature and the cooling water temperature was established and then embedded in another new correlation between the COP and the cooling water temperature that was used in simulations during the whole cooling season corresponding to each location. It was found that—the solar hot water should be maintained in the range of (80–100) °C depending on the cooling water temperature, the COP of the solar LiBr-H2O absorption chiller with or without cold storage tank could reach (76.5–82.4)% depending on the location, and the solar fraction could reach (29.5–62.0)% without cold storage tank and could exceed 100% with cold storage tank, and the excess cooling power being available to cover other types of cooling loads—through the building envelope, from lighting, and from occupants, etc.


  • Open Access

    New Perspective on Performances and Limits of Solar Fresh Air Cooling in Different Climatic Conditions

    by Ancuta C. Abrudan, Octavian G. Pop, Alexandru Serban, Mugur C. Balan

    The study carried out by simulation, concerns the thermal behavior of an office building’s solar fresh air cooling system, based on a LiBr-H2O absorption chiller in different climatic conditions. The coefficient of performance (COP) and the solar fraction were considered performance parameters and were analyzed with respect to the operating limits: risk of crystallization and maintaining at least a minimum degassing zone. A new correlation between the required solar hot temperature and the cooling water temperature was established and then embedded in another new correlation between the COP and the cooling water temperature that was used in simulations during the whole cooling season corresponding to each location. It was found that: the solar hot water should be maintained in the range of (80-100) °C depending on the cooling water temperature, the COP of the solar LiBr-H2O absorption chiller with or without cold storage tank can reach (76.5-82.4) % depending on the location, and the solar fraction can reach (29.5-62.0) % without cold storage tank and can exceed 100 % with cold storage tank, the excess cooling power being available to cover other types of cooling loads: through the building envelope, from lighting, from occupants, etc.

  • Open Access

    Economic and Environmental Analysis of Investing in Solar Water Heating Systems

    by Alexandru Şerban, Nicoleta Bărbuţă-Mişu, Nicoleta Ciucescu, Simona Paraschiv, Spiru Paraschiv

    Solar water heating (SWH) systems can provide a significant part of the heat energy that is required in the residential sector. The use of SWH systems is motivated by the desire to reduce energy consumption and especially to reduce a major source of greenhouse gas (GHG) emissions. The purposes of the present paper consist in: assessing the solar potential; analysing the possibility of using solar energy to heat water for residential applications in Romania; investigating the economic potential of SWH systems; and their contribution to saving energy and reducing CO2 emissions. The results showed that if solar systems are used, the annual energy savings amount to approximately 71%, and the reduction of GHG emissions into the atmosphere are of 18.5 tonnes of CO2 over the lifespan of the system, with a discounted payback period of 6.8–8.6 years, in accordance with the savings achieved depending on system characteristics, the solar radiation available, ambient air temperature and on heating load characteristics. Financially, the installation of SWH systems determines net savings of 805–1151 Euro in a 25-year period in the absence of governmental subsidies. According to the sensitivity analysis, installing a SWH system with subsidies of up to 50% determines the reduction of the discounted payback period to 3.1–3.9 years and the increase of net savings to 1570–1916 Euro. These results indicate that investing in these systems is cost-effective for Romanian households as long as the governmental subsidies increase.