AHAriadi Hazmi

Ariadi Hazmi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ariadi Hazmi has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Pengukuran Radiasi Elektromagnetik Frekuensi Sangat Tinggi (VHF) Petir Compact Intracloud Discharges

    by Primas Emeraldi, Ariadi Hazmi

    Pengukuran Radiasi Elektromagnetik Frekuensi Sangat Tinggi (VHF) Petir Compact Intracloud Discharges

  • Open Access

    Karakteristik Medan Listrik Atmosfer Kota Padang dan Hubungannya dengan Sambaran Petir Awan ke Tanah

    by Primas Emeraldi, Ariadi Hazmi

    The possibility of using Electric Field Mill data as parameter of lightning warning sistem requires atmospheric electric field data comparisons with lightning detection sistems. Transient electric field from lightning detektor compare with continues atmospheric electric field during thunderstorm.Based on atmospheric electric field measurement in Padang during the period of January - August 2015 there were 219 times thunderstorm events. In the event of thunderstorm,there is one or two thunderstorm event per day with average thunderstorm duration 173.48 minute per thunderstorm. There is no relations between the number of cloud to ground lightning strikes with the duration of the thunderstorm. Thunderstorm with 634 minute duration produces 2 cloud to ground lightning strikes while thunderstorm with shorter duration for 114 minute produces 13 cloud to ground lightning strikes. Keywords : Thunderstorm, Atmospheric Electric Field,Electric Field Mill Abstrak—Penggunaan data Electric Field Mill (EFM) dalam sistem peringatan bahaya petir membutuhkan kajian perbandingan data medan listrik atmosfer dengan sistem deteksi petir. Data dari detektor petir dibandingkan dengan data perubahan medan litrik statis selama proses badai petir. Berdasarkan pengukuran medan listrik atmosfer di kota Padang selama periode Januari – Agustus 2015 diperoleh data yaitu terdapat sebanyak 219 kali badai petir. Dalam satu hari terjadi satu sampai dua kali badai petir dengan durasi rata rata per badai petir adalah 173,48 menit. Setiap badai petir tidak selalu menghasilkan sambaran petir awan ke tanah. Tidak ada hubungan langsung antara jumlah sambaran petir awan ke tanah dengan lamanya durasi badai petir. Badai petir dengan durasi terlama pada tanggal 12 April 2015 dengan durasi 638 menit menghasilkan 2 kali sambaran petir awan ke tanah. Sedangkan badai petir pada 30 Januari 2015 dengan durasi 114 menit bisa menghasilkan 13 kali sambaran petir awan ke tanah. Kata Kunci : Badai Petir, Medan Listrik Atmosfer, Electric Field Mill

  • Open Access

    Characterization of Positive Cloud to Ground Flashes Observed in Indonesia

    by Ariadi Hazmi, Primas Emeraldi, Muhammad Imran Hamid, Nobuyuki Takagi, Daohong Wang

    The characteristics of 77 electric field changes of positive cloud to ground (CG) flashes in the tropics of Indonesia were investigated. It was found that the arithmetic mean (AM) and geometric mean (GM) values for 0%–100% and 10%–90% rise time were 12.7 μs, 11.9 μs and 6.1 μs, 5.8 μs, respectively. The percentages of single, double, and triple strokes of lightning flashes were 83% (64 cases), 16% (12 cases), and 1% (1 case), respectively. The AM and GM of the interstroke intervals and the return stroke (RS) amplitude ratios were 163.9 ms, 0.29, and 13.3 ms, 0.26, respectively. Furthermore, it was also found that 7 (9%) of 77 positive CG flashes had double peak return stroke waveforms with AM and GM values for 0%–100% and 10%–90% rise time of subsequent return strokes that were 6.7 μs, 6.4 μs and 4.1 μs, 4 μs, respectively. We inferred that these double peaks are produced by two ground terminations with a time interval varying from 7 to 560 μs.


  • Open Access

    Sistem Deteksi Petir Multistation Dengan Metode Time Of Arrival

    by Dasrinal Tessal, Primas Emeraldi, Ariadi Hazmi

    This study was done at ligtning detection system in Padang. The systems was consist of 3 electric field sensors with synchronous satelite GPS. Time of arrival and sensors coordinate was taken from each sensors. This data was used to calculate ligtning location by Time of Arrival Linear Spherical method. Then the distances between lighting and sensor can be calculated. The distances will compared with electric field waveforms recorded at lightning sensor to testing validity our results. After validity, lightning current peak can be calculated. 8 of 20 data sample are valid with lowest lightning current peak is -1,001 kA dan highest value is -2,661 kA. Keywords : Lightning, Lightning Detection System, Time of Arrival Ligtning Current Peak. Abstrak Penelitian ini dilakukan pada sistem deteksi petir yang dibangun di kota Padang. Sistem terdiri dari 3 sensor medan listrik dan GPS yang tersinkronisasi. Perbedaan waktu datang dan koordinat sensor didapatkan dari masing-masing sensor. Data ini digunakan untuk mendapatkan lokasi kejadian petir dengan metode Time of Arrival Linear Spherical. Setelah lokasi petir didapatkan maka jarak antara stasiun dengan lokasi kejadian petir dapat diketahui. Jarak sensor dengan petir dibandingkan dengan parameter gelombang medan listrik yang terekam sehingga dapat diketahui validnya hasil perhitungan. Setelah hasil perhitungan valid maka arus puncak dapat ditentukan. Dari 20 data tersebut terdapat 8 data yang bentuk gelombang medan listriknya sesuai dengan jarak antara sensor dengan lokasi petir dengan arus puncak petir yang terendah berada pada nilai -1,001 kA dan tertinggi berada pada nilai -22,661 kA. Kata Kunci: Pembangkit Listrik Tenaga Hybrid, Diesel Generator, Photovoltaic Array, HOMER, Optimalisasi, TNPC

  • Open Access

    Sistem Informasi Petir (SIP) Dengan Metode Lightning Distribution (LD) di Wilayah Sumatera Barat

    by Andrew Kurniawan Vadreas, Primas Emeraldi, Ariadi Hazmi

    This paper mapped 200 locations of lightning strikes in West Sumatra province. Mapping the location of lightning strikes as part of Lightning Information System was designed with the method of Lightning Distribution (LD). To get the location of lightning strikes obtained from the calculation reflection of ionosphere method to determine the distance of a lightning strike from stations of lightning and methods of Magnetic Direction Finding (MDF) to get directions from the lightning strike. Direction data obtained processed to generate a lightning incident location, then that location will be displayed on Google Maps. After that in the process of Lightning Distribution method which is a form of lightning strike density mapping by using the "File Format" grid, where each grid was measured to be 1 x 1 km2 called the Local Density Flash (LFD). If there are multiple point strikes on the grid will change the color that is on the map fit how many number of strikes on the grid which is a Probabilistic computation Flash Density (PFD). The depiction of the scale of danger lightning in the form of variations color changes at the point where the bolt of green color represents the minimum number density of lightning strikes that contains a single point and the red color represents the maximum number density of strikes which contains more than ten points strike. Based on the color distribution of lightning strikes and Payakumbuh Agam area has the highest rate of lightning strikes in the study period. Key words: reflection ionosphere, magnetic direction finding (MDF), lightning distribution, lightning information system, and google maps API. Abstrak Paper ini memetakan 200 lokasi sambaran petir di daerah Sumatera Barat. Pemetaan lokasi sambaran petir sebagai bagian dari Sistem Informasi Petir (SIP) dirancang dengan metode Lightning Distribution (LD). Lokasi sambaran petir diperoleh menggunakan metode refleksi ionosfer untuk mengetahui jarak sambaran petir dari stasiun pendeteksi petir dan metode Magnetic Direction Finding (MDF) untuk mendapatkan arah dari sambaran petir. Data arah kemudian diproses untuk menghasilkansuatulokasikejadianpetir, kemudian lokasitersebutakan ditampilkan pada Google Maps. Setelah itu di proses dengan metode Lightning Distribution yang merupakan bentuk pemetaan kerapatan sambaran petir dengan menggunakan “Format File grid”, dimana setiap grid diukur sebesar 1 x 1 km2 yang disebut dengan Local Flash Density (LFD). Jika terdapat beberapa titik sambaran pada satu grid akan merubah warna yang ada pada peta sesuai seberapa banyak jumlah sambaran pada satu grid yang merupakan perhitungan Probabilistic Flash Density (PFD). Penggambaran besarnya skala bahaya petir berupa variasi perubahan warna pada titik sambaran dimana warna hijau mewakili jumlah minimum kerapatan sambaran yang berisikan satu titik sambaran dan warna merah mewakili jumlah maximum kerapatan sambaran yang berisikan lebih dari sepuluh titik sambaran. Berdasarkan warna distribusi sambaran petir daerah Kabupaten Agam dan Payakumbuh memiliki tingkat sambaran petir tertinggi pada periode penelitian ini. Kata kunci :          refleksi ionosfer, magnetic direction finding (MDF), lightning distribution, sistem informasi petir, dangoogle maps API

  • Open Access

    Teknologi Sistem Plasma Radio –Frekuensi (RF) Untuk Menghilangkan Bakteri Escherichia Coli Pada Air Minum

    by Dean Corio, Ariadi Hazmi, Reni Desmiarti

    Refill drinking water is a source of public drinking water in Indonesia, but the quality is not guaranteed. less optimal means of water treatment to remove pollutants in Drinking Water Refill (AMIU), especially for raw water containing total coliforms and fecal coliforms cause AMIU quality is uncontrolled. The use of radio frequency plasma technology on AMIU processing system can be used as a solution. Induced plasma system by radio frequency in water can form the active compound. The active compounds will react to microorganisms and causing microorganisms be reduced. In testing wastewater 35,000 MPN (100 %), with plasma frequency of 3,3 MHz, the bacteria can degrade to 6 % and with frequency of 3,7 MHz bacteria can degrade to 0,07 %. 23.000 MPN testing river water (100 %), with plasma frequency of 3,3 MHz setting can degrade the bacteria to 9 % and with 3,7 MHz frequency setting can degrade the bacteria to 6 %. Keyword : plasma, radio frequency, total coliform, fecal coliform Abstrak Air minum isi ulang merupakan salah satu sumber air minum masyarakat di Indonesia, namun kualitasnya tidak terjamin. Kurang optimalnya alat pengolah air guna menghilangkan polutan produk pada Air Minum Isi Ulang (AMIU), terutama untuk air baku yang mengandung total coliforms maupun fecal coliforms menyebabkan kualitas AMIU tidak terkontrol dengan baik. Penggunaan teknologi plasma radio frekuensi pada sistem pengolahan AMIU bisa dijadikan solusi. Sistem plasma yang terinduksi melalui radio frekuensi pada air dapat membentuk senyawa aktif. Senyawa aktif ini akan bereaksi terhadap mikroorganisme dan menyebabkan mikroorganisme mati. Pada pengujian air limbah 350.000 MPN (100 %), dengan frekuensi plasma 3,3 MHz dapat mendegradasi bakteri sampai 6 % dan dengan settingan frekuensi 3,7 MHz dapat mendegradasi bakteri hingga 0,07 %. Pada pengujian air sungai 23.000 MPN (100 %), dengan settingan frekuensi plasma 3,3 MHz dapat mendegradasi bakteri hingga 9 % dan dengan settingan frekuensi 3,7 MHz dapat mendegradasi bakteri hinggaa 6 %. Kata kunci : plasma, radio frekuensi, total coliform, fecal coliform.

  • Open Access

    Karakteristik Preliminary Breakdown Petir Downward Leader Sebelum Sambaran Negatif Pertama

    by Zulka Hendri, Ariadi Hazmi

    A hundred lightning flash was observed in Padang city, West Sumatera at January until Mei 2013. The lightning that use to analyze is proceeding with preliminary breakdown pulse (PBP) train and followed by first negative return stroke (RS). Fast antenna capacitive was used to record electric field that produced of lightning flash. PBP-RS separation and pre-return stroke duration was used to analyze. Arithmetic and geometric mean of PPB-RS separation is 50,62ms and 31,73ms respectively. Arithmetic and geometric mean of pre-return stroke duration is 54,44ms and 33,92ms respectively. We have find two type of preliminary breakdown pulse train are; (1) the pulse train that dominant positive pulse at first half cycle (2) the pulse train that dominant negative pulse at first half cycle. The first type of pulse train have the PPB-RS separation and pre-return stroke duration that longer than the second type. The place that near with equator have PPB-RS separation and pre-return stroke duration that longer than the place far from equator (this conclusion we get from compare the result of our research with the result that produce from the other previous researchers). Keywords : lightning flash, preliminary breakdown, PPB-RS separation,  pre-return stroke duration.  Penelitian ini dilakukan terhadap 100 kejadian petir di Kota Padang Sumatera Barat dari bulan Januari sampai Mei 2013. Petir yang dianalisis diawali oleh deretan pulsa preliminary breakdown (PPB) yang terjadi sebelum sambaran negatif pertama dari awan ke tanah. Sinyal petir di rekam dengan memanfaatkan antena medan listrik (fast antenna). Analisis yang dilakukan yaitu PPB-RS separation dan pre-return stroke duration. Analisis PPB-RS separation menghasilkan rata-rata aritmatik 50,62 ms dan rata-rata geometriknya 31,73 ms. Analisis pre-return stroke duration menghasilkan rata-rata aritmatik 54,44 ms dan rata-rata geometriknya 33,92 ms. Dua tipe deretan pulsa PB yang ditemukan dalam penelitian ini yaitu; (1) deretan pulsa yang didominasi oleh pulsa-pulsa dengan polaritas positif pada setengah siklus pertama, (2) deretan pulsa yang didominasi oleh pulsa-pulsa dengan polaritas negatif pada setengah siklus pertamanya. Deretan pulsa dengan tipe pertama memiliki PPB-RS separation dan pre-return stroke duration yang lebih lama dibandingkan deretan pulsa dengan tipe ke dua. Daerah yang dekat dengan khatulistiwa cenderung memiliki PPB-RS separation dan pre-return stroke duration yang lebih lama dibandingkan daerah yang jauh dari khatulistiwa. Kesimpulan ini diperoleh dengan membandingkan data hasil penelitian ini dengan hasil penelitian yang dilakukan oleh peneliti sebelumnya di beberapa daerah berbeda. Kata Kunci : petir, preliminary breakdown, PPB-RS separation, pre-return stroke duration.