INIoana Nuta

Ioana Nuta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ioana Nuta has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Critical assessment of the Si-P system: P solubility in the Si-rich region and refining by phosphorus distillation

    by Simon Favre, Ioana Nuta, Guy Chichignoud, Evelyne Fischer, Christian Chatillon


  • Open Access

    Knudsen effusion mass spectrometry: Current and future approaches

    by Nathan S. Jacobson, Jean‐Yves Colle, Valentina Stolyarova, Torsten Markus, Ioana Nuta

    Rationale: Knudsen effusion mass spectrometry (KEMS) has been a powerful tool in physical chemistry since 1954. There are many excellent reviews of the basic principles of KEMS in the literature. In this review, we focus on the current status and potential growth areas for this instrumental technique. Methods: We discuss (1) instrumentation, (2) measurement techniques, and (3) selected novel applications of the technique. Improved heating methods and temperature measurement allow for better control of the Knudsen cell effusive source. Accurate computer models of the effusive beam and its introduction to the ionizer allow optimization of such parameters as sensitivity and removal of background signals. Computer models of the ionizer allow for optimized sensitivity and resolution. Additionally, data acquisition systems specifically tailored to a KEMS system permit improved quantity and quality of data. Results: KEMS is traditionally utilized for thermodynamic measurements of pure compounds and solutions. These measurements can now be strengthened using first principles and model‐based computational thermochemistry. First principles can be used to calculate accurate Gibbs energy functions ( gefs ) for improving third law calculations. Calculated enthalpies of formation and dissociation energies from ab initio methods can be compared to those measured using KEMS. For model‐based thermochemistry, solution parameters can be derived from measured thermochemical data on metallic and nonmetallic solutions. Beyond thermodynamic measurements, KEMS has been used for many specific applications. We select examples for discussion: measurements of phase changes, measurement/control of low‐oxygen potential systems, thermochemistry of ultrahigh‐temperature ceramics, geological applications, nuclear applications, applications to organic and organometallic compounds, and thermochemistry of functional room temperature materials, such as lithium ion batteries. Conclusions: We present an overview of the current status of KEMS and discuss ideas for improving KEMS instrumentation and measurements. We discuss selected KEMS studies to illustrate future directions of KEMS.


  • Thermodynamic assessment of RuO4 oxide

    by Ioana Nuta, Francois Virot, Evelyne Fischer, Christian Chatillon


  • Gaseous phase above Ru–O system: A thermodynamic data assessment

    by Ioana Nuta, Christian Chatillon, Fatima-Zahra Roki, Evelyne Fischer


  • Open Access

    Chromium Carbide Growth by Direct Liquid Injection Chemical Vapor Deposition in Long and Narrow Tubes, Experiments, Modeling and Simulation

    by Alexandre Michau, Francis Maury, Frederic Schuster, Ioana Nuta, Yoan Gazal, Rapahel Boichot, Michel Pons

    Chromium carbide layers were deposited using liquid-injection metal-organic chemical vapor deposition inside long (0.3 to 1 m) and narrow (8 to 24 mm in diameter) metallic tubes. The deposition was carried out using a molecular single-source, bis(benzene)chromium (BBC), as representative of the bis(arene)metal family diluted in toluene and injected with N2 as carrier gas. A multicomponent mass transport model for the simulation of the coupled fluid flow, heat transfer and chemistry was built. The kinetic mechanism of the growth of CrCx films was developed with the help of large-scale experiments to study the depletion of the precursors along the inner wall of the tube. The model fits well in the 400–550 °C temperature range and in the 1.3 × 102 to 7 × 103 Pa pressure range. The pressure is shown to have a pronounced effect on the deposition rate and thickness uniformity of the resulting coating. Below 525 °C the structure, composition and morphology of the films are not affected by changes of total pressure or deposition temperature. The coatings are amorphous and their Cr:C ratio is about 2:1, i.e., intermediate between Cr7C3 and Cr3C2. The model was applied to the design of a long reactor (1 m), with a double injection successively and alternatively undertaken at each end to ensure the best uniformity with sufficient thickness. This innovative concept can be used to optimize industrial deposition processes inside long and narrow tubes and channels.


  • Thermodynamic evaluation of oxidation during brazing process of medium-voltage electrical circuit breakers

    by Ioana Nuta, Christian Chatillon, Francois Chombart, Amélie Moreau

    The present study is a thermodynamic analysis of the different molecular flows occurring during the vacuum brazing of electrical vacuum bottles also called Vacuum Interrupters (mentioned later as VI). Among the available impurities either coming from the Vacuum Interrupters components materials or from vacuum technology, the analysis is focused on the oxygen since this impurity leads to formation of the more stable compounds, i.e. oxides. During the brazing cycles the resistors of the vacuum furnace and the VI materials including some braze components are the main sources of vapours that partly escape or make deposits on colder parts of the furnace. Vaporization and condensation processes are evaluated, their matter flows quantified and finally their interaction with residual oxygen calculated through a balance between input oxygen from vacuum or neutral gas and the different sources of oxygen coming from the parts under treatment. The enrichment of the VI materials and deposits with oxygen is evaluated as well as the limits required for vacuum conditions. The main conclusion is that present vacuum conditions allow correct working of the brazing sequence but in any other temperature steps or ramps, oxygen is trapped as oxides at the surface of the parts or accumulated in the bulk materials of the furnace.


  • Cracking study of pentakis(dimethylamino)tantalum vapors by Knudsen cell mass spectrometry

    by Perrine Violet, Ioana Nuta, Christian Chatillon, Elisabeth Blanquet

    Organometallic molecules are commonly used as gaseous precursors in Atomic Layer Deposition/Chemical Vapor Deposition (ALD/CVD) processes. However, the use of these molecules, which are generally thermally unstable at temperatures close to the deposition temperature, requires an understanding of their gas‐phase chemical behavior. The thermal cracking of the gaseous precursor, pentakis(dimethylamino) tantalum (PDMAT), generally adopted in the ALD/CVD TaN deposition processes, has been studied in the temperature range from 343 to 723K using a specific reactor coupled with a high‐temperature mass spectrometer. This reactor – built as tandem Knudsen cells – consists of two superimposed cells. The first stage reactor – an evaporation cell – provides an input saturated vapor flow operating from room temperature to 333K. The second stage cell, named the cracking cell, operated from 333 to 723K in the present study. Experiments showed the appearance of many gaseous species when the cracking temperature increased and, in particular, dimethylamine, corresponding to the saturated organic branches of PDMAT. Decomposition products of the HNC 2 H 6 branch were observed at relatively high temperature, namely above 633K. This gas‐phase study – as for the preceding saturated one – shows the presence of oxygen‐containing molecules in PDMAT cracked vapor. Thus, it explains the systematic presence of oxygen contamination in the deposited TaN films observed in ALD/CVD industrial processes. Copyright © 2010 John Wiley & Sons, Ltd.


  • A special reactor coupled with a high‐temperature mass spectrometer for the investigation of the vaporization and cracking of organometallic compounds

    by Perrine Violet, Ioana Nuta, Laurent Artaud, Hervé Collas, Elisabeth Blanquet, Christian Chatillon

    A special reactor coupled to a high‐temperature mass spectrometer was specifically designed for the study of vaporization and thermal cracking of organometallic precursors. This reactor has two kinds of settings. One is a single Knudsen effusion cell which enables the analysis of the composition of saturated vapors and the determination of the partial pressure of each gaseous molecule in equilibrium with its condensed phase. This cell is an evaporation/sublimation cell (operating from 243 to 473 K), which can be tightly closed – like a vacuum chamber – in order to protect organometallic compounds against moisture and atmospheric components. This cell can be independently weighed usefully to evaluate the equilibrium vapor pressures of the sample using the mass‐loss method. During experiments, the effusion aperture is externally opened for direct mass spectrometric measurements. The other setting dedicated to the study of thermal decomposition of gaseous molecules consists of a set of tandem cells: the previously described Knudsen cell and a cracking cell (operating from 293 to 973 K). Copyright © 2009 John Wiley & Sons, Ltd.


  • Knudsen cell mass spectrometry applied to the investigation of organometallic precursors vapours

    by Perrine Violet, Ioana Nuta, Christian Chatillon, Elisabeth Blanquet