MZMiao Zhang

Miao Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Miao Zhang has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Research on Underwater Electric Field-Coupled Wireless Charging System

    by Congling Hou, Jiahao He, Junfeng Liu, Miao Zhang, Wei Wang

    Underwater equipment is widely utilized in marine exploration, where energy supply limitations remain an important factor constraining its endurance, operational range, and performance efficiency. Traditional wired and battery-powered approaches exhibit notable technical shortcomings that compromise the flexibility and autonomy of underwater devices, thereby affecting the stability and efficiency of underwater exploration operations. This study employs electric field coupling wireless power transfer (EC-WPT) technology as its core research foundation to analyze how freshwater environments influence the electric-field coupling mechanism. Considering the characteristics of freshwater environments, the six-capacitor equivalent model is simplified into a π-type equivalent model that facilitates circuit analysis. A freshwater EC-WPT system architecture employing an LC-LC/LCLCL composite compensation topology is proposed, and the system equivalent circuit model is established. The transmission characteristics under both constant-current and constant-voltage operating modes were thoroughly investigated, with clear coupling relationships between circuit parameters identified, enabling effective parameter matching and design optimization. Simulation models of the freshwater EC-WPT system demonstrated stable power transmission under both conditions. Experimental validation using a physical platform confirmed 1 A constant-current output and 24 V constant-voltage output, with close agreement between experimental and simulation data. These findings validate the correctness and engineering feasibility of the proposed topology, theoretical framework, and parameter design methodology, providing valuable theoretical references and design guidelines for wireless power supply systems in fresh water environments.

  • An Integrated Inductor for Circulating Current Suppression in Two Parallel Interleaved VSCs

    by Yuanmao Ye, Yunqi Ma, Bofei Shu, Haolin Chen, Miao Zhang, Lingling Cao

    Parallel interleaved voltage source converters (PI-VSCs) have good performance in the terms of capacity enhancement and the output power quality improvement. However, a set of inductive filters needs to be installed between PI-VSCs to suppress the circulating current. This article presents a three-phase integrated inductor to replace this set of inductive filters. It is composed of six coils and one magnetic core. The core is formed by an outer toroidal and an inner Y-shaped sections, resulting in a simple and symmetrical structure. Mathematical model, theoretical analysis and comparative study are provided. It indicates that the integrated inductor has higher utilization of magnetic cores and it can be designed with smaller size than traditional schemes. Moreover, the proposed inductor has stronger common-mode circulation current suppression capability. This means that it can effectively suppress circulation current without the assistance of complex pulse width modulation algorithms. Its feasibility is effectively demonstrated by both simulation and experiment results.

  • A Bipolar Short-Pulsed Power Supply With Charge Feedback for a DBD Excimer Lamp

    by Xiongmin Tang, Juxiang Zhong, Chenghui Li, Jie Li, Xuecong Li, Miao Zhang

    Generating an optimal excitation voltage for a dielectric barrier discharge (DBD) load with a simple structure remains a significant challenge. To address this issue, this article presents improvements to a high-voltage high-frequency converter and proposes a novel bipolar short-pulsed power supply integrated with charge feedback. Specifically, by replacing the two resistance–capacitance (RC) snubber circuits in the original converter with two charge feedback circuits, the proposed power supply achieves three key enhancements: a sharp increase in the efficiency of the original converter, further suppression of excitation voltage oscillations, and a notable improvement in the rising rate of the excitation voltage. Additionally, the proposed power supply inherits the inherent advantages of the original converter, including the stable generation of bipolar excitation voltage, smooth adjustability of the excitation voltage idle time, and strong adaptability to different DBD excimer lamps. Experimental validation was conducted on a DBD excimer lamp. Under operating conditions of 100kHz, 17kV, and 90W, the power supply achieved an efficiency of 93%. The average voltage rise rate reached $10.638\times 10^{9}$ V/s, representing a 30% improvement over the original converter.

  • Analysis and Experimental Validation of a New High-Voltage High-Frequency Converter for a Dielectric Barrier Discharge Lamp

    by Xiongmin Tang, Chenghui Li, Haoyuan Xie, Zihao Zhao, Miao Zhang, Xuecong Li

    If a bipolar excitation voltage is characterized by a high voltage, a high frequency, a suitable width, a necessary idle time, and a suppressed oscillation, it is conducive to improving the efficiency of a dielectric barrier discharge (DBD) lamp. Unfortunately, this form of excitation voltage is difficult to generate for a DBD lamp in the existing power supplies. To address this issue, a new high-voltage high-frequency converter for a DBD lamp is proposed. The high-frequency bipolar pulse excitation voltage is achieved with two symmetrical resonant circuits. The width of the pulse can be adjusted by changing the value of the resonant capacitance. The duration of the idle time can be altered by changing the operating frequency or the value of the resonant capacitances. The oscillation of the excitation voltage can be suppressed effectively by the unidirectional conductivity of the diodes. Besides the above-mentioned characteristics, the proposed converter possesses the advantages of simple structure and convenient control. Finally, the feasibility of the proposed converter is verified with an experimental prototype.


  • A Novel Fault-Tolerant Multilevel Inverter With Preserved Output Integrity Under Post-Fault

    by Miao Zhang, Shaoli Deng, Jianhang Lu, Dali Zheng, Ningrui Yang

    A novel fault-tolerant multilevel inverter (FT-MLI) with fault output integrity is presented in this article. Source fault tolerance, nine-level output, quadruple boost, and low total standing voltage (TSV) are the key features of the proposed topology. Unlike other FT-MLIs, the proposed FT-MLI can maintain the same level number and magnitude of output voltage in the post-fault condition. The article discusses the operational principles for normal and fault modes, introduces the modulation strategy and capacitance calculation, and outlines the fault tolerance method for the proposed FT-MLI. To optimize for larger capacitor voltage ripple after a fault, a novel pulse width modulation (PWM) is proposed. A comparative study is conducted to evaluate the performance of the proposed topology against other FT-MLIs. Finally, the feasibility of the proposed FT-MLI was verified by simulation and experiment.


  • A Novel Control Strategy for Improving the Performance of Hybrid Active Power Filters

    by Junming Wen, Miao Zhang, Jianhang Lu, YiChuan Guan, Shiyu Wu, Chunshou Feng


  • Analysis and Experimental Validation of an Integrated Current-Source Power Supply With High Power Factor for DBD Applications

    by Xiongmin Tang, Zhihong Lin, Zexin Zhou, Yongquan Chen, Miao Zhang

    An integrated current-source high-frequency pulse excitation power supply with high power factor (PF), low total harmonic distortion (THD) of the input current, and high efficiency for dielectric barrier discharge (DBD) loads is proposed in this article. The proposed power supply consists of a current source unit and a bipolar pulse excitation voltage generation unit. The current source unit is used to generate a current source for the excitation voltage generation unit and achieve a high PF and a low current harmonic distortion in the ac side of the proposed power supply. By planning the modes of the excitation voltage generation unit, not only a bipolar pulse excitation voltage with high rising and falling rates on the DBD loads is generated, but also the soft-switching of all power switches is achieved. The experimental results show that not only a unity PF ( $>$ 0.99) and a low THD ( $<$ 10%) are achieved, but also a bipolar high-frequency (hundreds of kilohertz) pulse excitation voltage with high average rising and falling rates (7.227 $\times$ 109 V/s) for a DBD excimer lamp is generated. Finally, in comparison with different power supplies, the proposed power supply can not only fully take advantage of the potential of the DBD excimer lamp but also has many advantages of high efficiency (92%), integrated structure, and simple driver.


  • Parameter design of active damping-based shunt hybrid active power filters

    by Jianhang Lu, Miao Zhang, Junming Wen, Dali Zheng, Shaoli Deng, Xiang Shi, Ling Yang


  • Open Access

    A Switching Frequency Optimized Space Vector Pulse Width Modulation (SVPWM) Scheme for Cascaded Multilevel Inverters

    by Xiongmin Tang, Junhui Zhang, Zheng Liu, Miao Zhang

    This paper presents a novel switching frequency optimized space vector pulse width modulation (SVPWM) scheme for cascaded multilevel inverters. The proposed SVPWM is developed in a α′β′ coordinate system, in which the voltage vectors have only integer entries and the absolute increment of coordinate values between adjacent vectors is equal to dc-bus voltage of power cells (1 pu). The new SVPWM scheme is built with three categories of switching paths. During each switching path, the change of one phase voltage is limited in 1 pu. This contributes to decrease the number of commutations of switches. The proposed SVPWM scheme is validated on a 7-level cascaded inverter and the results show that it significantly outperforms traditional SVPWM schemes in terms of decreasing the number of switch commutations.