Parastoo Dehkordi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Parastoo Dehkordi has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Ainara Garde
Dep. of ESAII, Centre for Biomedical Engineering Research, Technical University of Catalonia (UPC), c./ Gargallo, 5, 08028, Barcelona, Spain
1 shared publication - Ajay K. Verma
School of Electrical Engineering and Computer Science, University of North Dakota, Grand Forks, ND 58202, USA
1 shared publication Farzad Khosrow-Khavar
Heart Force Inc, Vancouver, British Columbia, CANADA
1 shared publication- Guy Albert Dumont
Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
1 shared publication - Jau-Shin Lou
Department of Neurology, Sanford Health, Fargo, ND 58103, USA
1 shared publication - John Mark Ansermino
University of British Columbia
1 shared publication
Latest Publications
- 1 May 2020
- Published by IOP Publishing in Physiological Measurement
- Vol. 41 (5) , 055004
Investigating the estimation of cardiac time intervals using gyrocardiography
Objective : Assessment of cardiac time intervals (CTIs) is essential for monitoring cardiac performance. Recently, gyrocardiography (GCG) has been introduced as a non-invasive technology for cardiac monitoring. GCG measures the chest’s angular precordial vibrations caused by myocardium wall motion using a gyroscope sensor attached to the sternum. In this study, we investigated the accuracy and reproducibility of estimating CTIs from the GCG recordings of 50 adults. Approach : We proposed five fiducial points for the GCG waveforms associated with the opening and closure of aortic and mitral valves. Two annotators annotated the suggested points on each cardiac cycle. The points were compared to the corresponding opening and closing of cardiac valves delineated on Tissue Doppler imaging (TDI) recordings. The fiducial points were annotated on seismocardiography (SCG) and impedance cardiography (ICG) signals recorded simultaneously. Main results : For estimating the timing of mitral valve closure, aortic valve opening, aortic valve closure, and mitral valve opening, 40%, 67%, 75%, and 70% of GCG annotations fell in the corresponding echocardiography ranges, respectively. The results showed moderate-to-excellent (r = 0.4-0.92; p-value < 0.01) correlation between the measured and the reference CTls. A myocardial performance index (Tei index) adapted using joint GCG and SCG resulted in a moderate correlation (r = 0.4; p-value < 0.001). Significance : The findings showed that the CTIs can be easily measured using GCG. Also, we found that using SCG and GCG recordings together could provide an opportunity to estimate CTIs more accurately, and make it possible to calculate the Tei index as an indicator of myocardial performance.
- 1 May 2020
- Published by IOP Publishing in Physiological Measurement
- Vol. 41 (5) , 055004
Investigating the estimation of cardiac time intervals using gyrocardiography
Objective : Assessment of cardiac time intervals (CTIs) is essential for monitoring cardiac performance. Recently, gyrocardiography (GCG) has been introduced as a non-invasive technology for cardiac monitoring. GCG measures the chest’s angular precordial vibrations caused by myocardium wall motion using a gyroscope sensor attached to the sternum. In this study, we investigated the accuracy and reproducibility of estimating CTIs from the GCG recordings of 50 adults. Approach : We proposed five fiducial points for the GCG waveforms associated with the opening and closure of aortic and mitral valves. Two annotators annotated the suggested points on each cardiac cycle. The points were compared to the corresponding opening and closing of cardiac valves delineated on Tissue Doppler imaging (TDI) recordings. The fiducial points were annotated on seismocardiography (SCG) and impedance cardiography (ICG) signals recorded simultaneously. Main results : For estimating the timing of mitral valve closure, aortic valve opening, aortic valve closure, and mitral valve opening, 40%, 67%, 75%, and 70% of GCG annotations fell in the corresponding echocardiography ranges, respectively. The results showed moderate-to-excellent (r = 0.4-0.92; p-value < 0.01) correlation between the measured and the reference CTls. A myocardial performance index (Tei index) adapted using joint GCG and SCG resulted in a moderate correlation (r = 0.4; p-value < 0.001). Significance : The findings showed that the CTIs can be easily measured using GCG. Also, we found that using SCG and GCG recordings together could provide an opportunity to estimate CTIs more accurately, and make it possible to calculate the Tei index as an indicator of myocardial performance.
- Open Access
- 10 July 2019
- Published by MDPI AG in Brain Sciences
- Vol. 9 (7) , 162
Relationship between Ischemic Stroke and Pulse Rate Variability as a Surrogate of Heart Rate Variability
Autonomic reflex ascertains cardiovascular homeostasis during standing. Impaired autonomic reflex could lead to dizziness and falls while standing; this is prevalent in stroke survivors. Pulse rate variability (PRV) has been utilized in the literature in lieu of heart rate variability (HRV) for ambulatory and portable monitoring of autonomic reflex predominantly in young, healthy individuals. Here, we compared the PRV with gold standard HRV for monitoring autonomic reflex in ischemic stroke survivors. Continuous blood pressure and electrocardiography were acquired from ischemic stroke survivors (64 ± 1 years) and age-matched controls (65 ± 2 years) during a 10-minute sit-to-stand test. Beat-by-beat heart period (represented by RR and peak-to-peak (PP) intervals), systolic blood pressure (SBP), diastolic blood pressure (DBP), and pulse arrival time (PAT), an indicator of arterial stiffness, were derived. Time and frequency domain HRV (from RR intervals) and PRV (from PP intervals) metrics were extracted. PAT was lower (248 ± 7 ms vs. 270 ± 8 ms, p < 0.05) suggesting higher arterial stiffness in stroke survivors compared to controls during standing. Further, compared to controls, the agreement between HRV and PRV was impaired in stroke survivors while standing. The study outcomes suggest that caution should be exercised when considering PRV as a surrogate of HRV for monitoring autonomic cardiovascular control while standing in stroke survivors.
- 10 July 2019
- Published by MDPI AG in Brain Sciences
- Vol. 9 (7) , 162
Open AccessRelationship between Ischemic Stroke and Pulse Rate Variability as a Surrogate of Heart Rate Variability
Autonomic reflex ascertains cardiovascular homeostasis during standing. Impaired autonomic reflex could lead to dizziness and falls while standing; this is prevalent in stroke survivors. Pulse rate variability (PRV) has been utilized in the literature in lieu of heart rate variability (HRV) for ambulatory and portable monitoring of autonomic reflex predominantly in young, healthy individuals. Here, we compared the PRV with gold standard HRV for monitoring autonomic reflex in ischemic stroke survivors. Continuous blood pressure and electrocardiography were acquired from ischemic stroke survivors (64 ± 1 years) and age-matched controls (65 ± 2 years) during a 10-minute sit-to-stand test. Beat-by-beat heart period (represented by RR and peak-to-peak (PP) intervals), systolic blood pressure (SBP), diastolic blood pressure (DBP), and pulse arrival time (PAT), an indicator of arterial stiffness, were derived. Time and frequency domain HRV (from RR intervals) and PRV (from PP intervals) metrics were extracted. PAT was lower (248 ± 7 ms vs. 270 ± 8 ms, p < 0.05) suggesting higher arterial stiffness in stroke survivors compared to controls during standing. Further, compared to controls, the agreement between HRV and PRV was impaired in stroke survivors while standing. The study outcomes suggest that caution should be exercised when considering PRV as a surrogate of HRV for monitoring autonomic cardiovascular control while standing in stroke survivors.
- Open Access
Correntropy-Based Pulse Rate Variability Analysis in Children with Sleep Disordered Breathing
Pulse rate variability (PRV), an alternative measure of heart rate variability (HRV), is altered during obstructive sleep apnea. Correntropy spectral density (CSD) is a novel spectral analysis that includes nonlinear information. We recruited 160 children and recorded SpO2 and photoplethysmography (PPG), alongside standard polysomnography. PPG signals were divided into 1-min epochs and apnea/hypoapnea (A/H) epochs labeled. CSD was applied to the pulse-to-pulse interval time series (PPIs) and five features extracted: the total spectral power (TP: 0.01–0.6 Hz), the power in the very low frequency band (VLF: 0.01–0.04 Hz), the normalized power in the low and high frequency bands (LFn: 0.04–0.15 Hz, HFn: 0.15–0.6 Hz), and the LF/HF ratio. Nonlinearity was assessed with the surrogate data technique. Multivariate logistic regression models were developed for CSD and power spectral density (PSD) analysis to detect epochs with A/H events. The CSD-based features and model identified epochs with and without A/H events more accurately relative to PSD-based analysis (area under the curve (AUC) 0.72 vs. 0.67) due to the nonlinearity of the data. In conclusion, CSD-based PRV analysis provided enhanced performance in detecting A/H epochs, however, a combination with overnight SpO2 analysis is suggested for optimal results.
Open AccessCorrentropy-Based Pulse Rate Variability Analysis in Children with Sleep Disordered Breathing
Pulse rate variability (PRV), an alternative measure of heart rate variability (HRV), is altered during obstructive sleep apnea. Correntropy spectral density (CSD) is a novel spectral analysis that includes nonlinear information. We recruited 160 children and recorded SpO2 and photoplethysmography (PPG), alongside standard polysomnography. PPG signals were divided into 1-min epochs and apnea/hypoapnea (A/H) epochs labeled. CSD was applied to the pulse-to-pulse interval time series (PPIs) and five features extracted: the total spectral power (TP: 0.01–0.6 Hz), the power in the very low frequency band (VLF: 0.01–0.04 Hz), the normalized power in the low and high frequency bands (LFn: 0.04–0.15 Hz, HFn: 0.15–0.6 Hz), and the LF/HF ratio. Nonlinearity was assessed with the surrogate data technique. Multivariate logistic regression models were developed for CSD and power spectral density (PSD) analysis to detect epochs with A/H events. The CSD-based features and model identified epochs with and without A/H events more accurately relative to PSD-based analysis (area under the curve (AUC) 0.72 vs. 0.67) due to the nonlinearity of the data. In conclusion, CSD-based PRV analysis provided enhanced performance in detecting A/H epochs, however, a combination with overnight SpO2 analysis is suggested for optimal results.