Marco A. Escarola-Rosas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marco A. Escarola-Rosas has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Agustin Leobardo Herrera May
Centro de Investigación en Micro y Nanotecnología, Universidad Veracruzana, Boca del Río 94294, Veracruz, Mexico
2 shared publications - Adrian Herrera-Amaya
Depto, Ingeniería Mecánica, Campus Irapuato-Salamanca, Universidad de Guanajuato/Carretera Salamanca-Valle de Santiago Km. 3.5 + 1.8 km, Salamanca, GTO 36885, Mexico
1 shared publication - Francisco López-Huerta
Faculty of Electrical and Electronic Engineering, Universidad Veracruzana, Boca del Río 94294, Veracruz, Mexico
1 shared publication - Hector Vazquez-Leal
Facultad de Instrumentación Electrónica, Universidad Veracruzana, Cto. Gonzalo Aguirre Beltrán S/N, Xalapa 91000, Veracruz, Mexico
1 shared publication - J. Jesús Villegas-Saucillo
Departamento de Ingenieria Electrónica. Línea de Investigación, Bioelectrónica, Tecnológico Nacional de México en Celaya, Celaya 38010, Mexico
1 shared publication - Jaime Martínez-Castillo
Centro de Investigación en Micro y Nanotecnología, Universidad Veracruzana, Boca del Río 94294, Veracruz, Mexico
1 shared publication
Latest Publications
- Open Access
- 27 April 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (9) , 3940
Measurements of the Magnetic Field Variations Related with the Size of V-Shaped Notches in Steel Pipes
Gas and oil pipeline networks require periodic inspections to detect cracks or notches that can cause industrial accidents and environmental contamination. For these inspections, the metal magnetic memory (MMM) method could be used as a non-destructive testing (NDT) technique, which does not need expensive equipment and high-skilled operators. However, more investigations are required to quantify the size and shape of defects in ferromagnetic pipes using the MMM signals. We present experimental measurements of MMM signals around five small V-shaped notches of an ASTM-A36 steel pipe using a three-axis magnetoresistive sensor. The V-shaped notches have different values of depth (500 µm, 1000 µm, 1500 µm, 2000 µm and 2500 µm) and width (1000 µm, 1500 µm, 2000 µm, 3000 µm and 3500 µm). We measured the variations of tangential and normal MMM signals around these defects and their relationships with the size of each defect. The first V-notch defect (500 μm depth and 1000 μm width) registers variations of the tangential and normal MMM signals of 14.32 μT ± 1.62 μT and 27.95 μT ± 1.14 μT, respectively. On the other hand, the fifth V-notch defect (2500 μm depth and 3500 μm width) has variations of the tangential and normal MMM signals of 68.75 μT ± 1.10 μT and 71.37 μT ± 0.72 μT, respectively. The MMM method could be used for real-time monitoring of V-shaped notches in steel pipes. This method does not require special treatment of steel pipes.
- 27 April 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (9) , 3940
Open AccessMeasurements of the Magnetic Field Variations Related with the Size of V-Shaped Notches in Steel Pipes
Gas and oil pipeline networks require periodic inspections to detect cracks or notches that can cause industrial accidents and environmental contamination. For these inspections, the metal magnetic memory (MMM) method could be used as a non-destructive testing (NDT) technique, which does not need expensive equipment and high-skilled operators. However, more investigations are required to quantify the size and shape of defects in ferromagnetic pipes using the MMM signals. We present experimental measurements of MMM signals around five small V-shaped notches of an ASTM-A36 steel pipe using a three-axis magnetoresistive sensor. The V-shaped notches have different values of depth (500 µm, 1000 µm, 1500 µm, 2000 µm and 2500 µm) and width (1000 µm, 1500 µm, 2000 µm, 3000 µm and 3500 µm). We measured the variations of tangential and normal MMM signals around these defects and their relationships with the size of each defect. The first V-notch defect (500 μm depth and 1000 μm width) registers variations of the tangential and normal MMM signals of 14.32 μT ± 1.62 μT and 27.95 μT ± 1.14 μT, respectively. On the other hand, the fifth V-notch defect (2500 μm depth and 3500 μm width) has variations of the tangential and normal MMM signals of 68.75 μT ± 1.10 μT and 71.37 μT ± 0.72 μT, respectively. The MMM method could be used for real-time monitoring of V-shaped notches in steel pipes. This method does not require special treatment of steel pipes.
- Open Access
- 25 June 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (7) , 203
Design and Modeling of Polysilicon Electrothermal Actuators for a MEMS Mirror with Low Power Consumption
Endoscopic optical-coherence tomography (OCT) systems require low cost mirrors with small footprint size, out-of-plane deflections and low bias voltage. These requirements can be achieved with electrothermal actuators based on microelectromechanical systems (MEMS). We present the design and modeling of polysilicon electrothermal actuators for a MEMS mirror (100 μm × 100 μm × 2.25 μm). These actuators are composed by two beam types (2.25 μm thickness) with different cross-section area, which are separated by 2 μm gap. The mirror and actuators are designed through the Sandia Ultra-planar Multi-level MEMS Technology V (SUMMiT V®) process, obtaining a small footprint size (1028 μm × 1028 µm) for actuators of 550 µm length. The actuators have out-of-plane displacements caused by low dc voltages and without use material layers with distinct thermal expansion coefficients. The temperature behavior along the actuators is calculated through analytical models that include terms of heat energy generation, heat conduction and heat energy loss. The force method is used to predict the maximum out-of-plane displacements in the actuator tip as function of supplied voltage. Both analytical models, under steady-state conditions, employ the polysilicon resistivity as function of the temperature. The electrothermal-and structural behavior of the actuators is studied considering different beams dimensions (length and width) and dc bias voltages from 0.5 to 2.5 V. For 2.5 V, the actuator of 550 µm length reaches a maximum temperature, displacement and electrical power of 115 °C, 10.3 µm and 6.3 mW, respectively. The designed actuation mechanism can be useful for MEMS mirrors of different sizes with potential application in endoscopic OCT systems that require low power consumption.
- 25 June 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (7) , 203
Open AccessDesign and Modeling of Polysilicon Electrothermal Actuators for a MEMS Mirror with Low Power Consumption
Endoscopic optical-coherence tomography (OCT) systems require low cost mirrors with small footprint size, out-of-plane deflections and low bias voltage. These requirements can be achieved with electrothermal actuators based on microelectromechanical systems (MEMS). We present the design and modeling of polysilicon electrothermal actuators for a MEMS mirror (100 μm × 100 μm × 2.25 μm). These actuators are composed by two beam types (2.25 μm thickness) with different cross-section area, which are separated by 2 μm gap. The mirror and actuators are designed through the Sandia Ultra-planar Multi-level MEMS Technology V (SUMMiT V®) process, obtaining a small footprint size (1028 μm × 1028 µm) for actuators of 550 µm length. The actuators have out-of-plane displacements caused by low dc voltages and without use material layers with distinct thermal expansion coefficients. The temperature behavior along the actuators is calculated through analytical models that include terms of heat energy generation, heat conduction and heat energy loss. The force method is used to predict the maximum out-of-plane displacements in the actuator tip as function of supplied voltage. Both analytical models, under steady-state conditions, employ the polysilicon resistivity as function of the temperature. The electrothermal-and structural behavior of the actuators is studied considering different beams dimensions (length and width) and dc bias voltages from 0.5 to 2.5 V. For 2.5 V, the actuator of 550 µm length reaches a maximum temperature, displacement and electrical power of 115 °C, 10.3 µm and 6.3 mW, respectively. The designed actuation mechanism can be useful for MEMS mirrors of different sizes with potential application in endoscopic OCT systems that require low power consumption.