Jong-Soo Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jong-Soo Kim has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Byoung Kuk Lee
College of Information and Communication Engineering, Sungkyunkwan University, Suwon, Korea
3 shared publications - Dongmyoung Joo
Power System Research Center, Korea Electronics Technology Institute, Seongnam, Republic of Korea
3 shared publications B.K. Lee
College of Information and Communication Engineering Sungkyunkwan University 300 Cheoncheon‐dong, Jangan‐gu Suwon Gyeonggi‐do Republic of Korea
2 shared publications- Chul-Min Kim
Department of Electrical Engineering, Daejin University, Pocheon 11159, Republic of Korea
2 shared publications - Chul-Min Kim
Korea Electronics Technology Institute, Bucheon 14502, Republic of Korea
2 shared publications - Beom-Su Park
Department of Electrical Engineering, Daejin University, Pocheon-si, Korea
1 shared publication
Latest Publications
- 22 May 2026
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 21 (4) , 3503-3513
Effects of Flat-Core Geometry on Magnetic Flux Distribution and Thermal Behavior in Integrated Transformers for High-Frequency LLC Converters
- 22 May 2026
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 21 (4) , 3503-3513
Effects of Flat-Core Geometry on Magnetic Flux Distribution and Thermal Behavior in Integrated Transformers for High-Frequency LLC Converters
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 120851-120859
An Analytical SR Timing Compensation Scheme Considering Switch Output Capacitance for High-Frequency LLC Resonant Converters
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 120851-120859
Open AccessAn Analytical SR Timing Compensation Scheme Considering Switch Output Capacitance for High-Frequency LLC Resonant Converters
- Open Access
- 22 April 2025
- Published by MDPI AG in Electronics
- Vol. 14 (9) , 1701
Optimal Design of Resonant Network for 800 V Class 11.1 kW Wireless Power Transfer System with Double-Sided LCC Compensation Circuit
This study proposes an optimal resonant network design for an 11.1 kW wireless power transfer (WPT) system with a double-sided LCC compensation circuit, targeting 800 V class battery applications. Conventional WPT circuit topologies and design parameters specified in existing standards, such as SAE J2954, are unsuitable for 800 V class battery systems because they impose excessive voltage and current stresses on the resonant network components. To address this, the proposed design focuses on minimizing component stresses while ensuring compliance with the output voltage requirements for 800 V battery charging. A switched capacitor technique is integrated into the resonant network to dynamically adjust the compensation capacitance, enabling seamless adaptation to the constant current–constant voltage charging profile. The feasibility of the WPT system is validated through simulations and experiments, demonstrating an input voltage of 400 VDC, an output voltage range of 560–820 VDC, and a rated power capacity of 11.1 kW. Under rated conditions, the system achieves a peak efficiency of 95%, underscoring its practicality for high-voltage electric vehicle charging applications.
- 22 April 2025
- Published by MDPI AG in Electronics
- Vol. 14 (9) , 1701
Open AccessOptimal Design of Resonant Network for 800 V Class 11.1 kW Wireless Power Transfer System with Double-Sided LCC Compensation Circuit
This study proposes an optimal resonant network design for an 11.1 kW wireless power transfer (WPT) system with a double-sided LCC compensation circuit, targeting 800 V class battery applications. Conventional WPT circuit topologies and design parameters specified in existing standards, such as SAE J2954, are unsuitable for 800 V class battery systems because they impose excessive voltage and current stresses on the resonant network components. To address this, the proposed design focuses on minimizing component stresses while ensuring compliance with the output voltage requirements for 800 V battery charging. A switched capacitor technique is integrated into the resonant network to dynamically adjust the compensation capacitance, enabling seamless adaptation to the constant current–constant voltage charging profile. The feasibility of the WPT system is validated through simulations and experiments, demonstrating an input voltage of 400 VDC, an output voltage range of 560–820 VDC, and a rated power capacity of 11.1 kW. Under rated conditions, the system achieves a peak efficiency of 95%, underscoring its practicality for high-voltage electric vehicle charging applications.
- 2 April 2025
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 20 (4) , 2221-2232
Development of an Efficient Integrated Test Circuit for Overcurrent and Short Circuit Current Testing of the MMC-Based MVDC Valve
- 2 April 2025
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 20 (4) , 2221-2232
Development of an Efficient Integrated Test Circuit for Overcurrent and Short Circuit Current Testing of the MMC-Based MVDC Valve
- Open Access
- 4 October 2024
- Published by MDPI AG in Electronics
- Vol. 13 (19) , 3929
A Control Strategy for Suppressing Zero-Crossing Current of Single-Phase Half-Bridge Active Neutral-Point-Clamped Three-Level Inverter
Multi-level inverters have characteristics suitable for high-voltage and high-power applications through various topology configurations. These reduce harmonic distortion and improve the quality of the output waveform by generating a multi-level output voltage waveform. In particular, an active neutral-point-clamped topology is one of the multi-level inverters advantageous for high-power and medium-voltage applications. It has the advantage of controlling the output waveform more precisely by actively clamping the neutral point using an active switch and diode. However, it has a problem, which is that an unwanted zero-crossing current may occur if an inaccurate switching signal is applied at the time when the polarity of the output voltage changes. In this paper, a control strategy to suppress the zero-crossing current of a single-phase half-bridge three-level active neutral-point-clamped inverter is proposed. The operating principle of a single-phase half-bridge three-level active neutral-point-clamped inverter is identified through an operation mode analysis. In addition, how the switching signal is reflected in an actual digital signal processor is analyzed to determine the situation in which the zero-crossing current occurs. Through this, a control strategy capable of suppressing zero-crossing current is designed. The proposed method prevents a zero-crossing current by appropriately modifying the update timing of reference voltages at the point where the polarity of the output changes. The validity of the proposed method is verified through simulation and experiments. Based on the proposed method, the total harmonic distortion of the output current is significantly reduced from 12.15% to 4.59% in a full-load situation.
- 4 October 2024
- Published by MDPI AG in Electronics
- Vol. 13 (19) , 3929
Open AccessA Control Strategy for Suppressing Zero-Crossing Current of Single-Phase Half-Bridge Active Neutral-Point-Clamped Three-Level Inverter
Multi-level inverters have characteristics suitable for high-voltage and high-power applications through various topology configurations. These reduce harmonic distortion and improve the quality of the output waveform by generating a multi-level output voltage waveform. In particular, an active neutral-point-clamped topology is one of the multi-level inverters advantageous for high-power and medium-voltage applications. It has the advantage of controlling the output waveform more precisely by actively clamping the neutral point using an active switch and diode. However, it has a problem, which is that an unwanted zero-crossing current may occur if an inaccurate switching signal is applied at the time when the polarity of the output voltage changes. In this paper, a control strategy to suppress the zero-crossing current of a single-phase half-bridge three-level active neutral-point-clamped inverter is proposed. The operating principle of a single-phase half-bridge three-level active neutral-point-clamped inverter is identified through an operation mode analysis. In addition, how the switching signal is reflected in an actual digital signal processor is analyzed to determine the situation in which the zero-crossing current occurs. Through this, a control strategy capable of suppressing zero-crossing current is designed. The proposed method prevents a zero-crossing current by appropriately modifying the update timing of reference voltages at the point where the polarity of the output changes. The validity of the proposed method is verified through simulation and experiments. Based on the proposed method, the total harmonic distortion of the output current is significantly reduced from 12.15% to 4.59% in a full-load situation.
- Open Access
- 25 March 2024
- Published by MDPI AG in Electronics
- Vol. 13 (7) , 1203
Highly Reliable Short-Circuit Protection Circuits for Gallium Nitride High-Electron-Mobility Transistors
This paper presents a circuit for detecting and protecting against short circuits in E-mode gallium nitride high-electron-mobility transistors (GaN HEMTs) and analyzes the protection performance of the circuit. GaN HEMTs possess fast switching characteristics that enable high efficiency and power density in power conversion devices. However, these characteristics also pose challenges in protecting against short circuits and overcurrent situations. The proposed method detects short-circuit events by monitoring an instantaneous drop in the DC bus voltage of a circuit with GaN HEMTs applied and uses a bandpass filter to prevent the malfunction of the short-circuit protection circuit during normal switching and ensure highly reliable operation. Using this method, the short-circuit detection time of E-mode GaN HEMTs can be reduced to 257 ns, successfully protecting the device without malfunctions even in severe short-circuit situations occurring at high DC link voltages.
- 25 March 2024
- Published by MDPI AG in Electronics
- Vol. 13 (7) , 1203
Open AccessHighly Reliable Short-Circuit Protection Circuits for Gallium Nitride High-Electron-Mobility Transistors
This paper presents a circuit for detecting and protecting against short circuits in E-mode gallium nitride high-electron-mobility transistors (GaN HEMTs) and analyzes the protection performance of the circuit. GaN HEMTs possess fast switching characteristics that enable high efficiency and power density in power conversion devices. However, these characteristics also pose challenges in protecting against short circuits and overcurrent situations. The proposed method detects short-circuit events by monitoring an instantaneous drop in the DC bus voltage of a circuit with GaN HEMTs applied and uses a bandpass filter to prevent the malfunction of the short-circuit protection circuit during normal switching and ensure highly reliable operation. Using this method, the short-circuit detection time of E-mode GaN HEMTs can be reduced to 257 ns, successfully protecting the device without malfunctions even in severe short-circuit situations occurring at high DC link voltages.
- Open Access
- 28 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 32752-32758
Precise Modeling for Reducing Output Voltage Control Error of RX-Sensorless IPT System
This paper presents RX-Sensorless technologies required in a self-induced type of low power wireless power transfer system. Recently, apart from the fields of smartphone and electrical vehicles which have been arduously studied for application of wireless power transfer, wireless power transfer technologies are being applied to various fields. Among them, there is a very rapidly increasing demand for low power systems in displays, body implant medical devices, drones, electrical kickboards and so on. In order to acquire portability of RX side of low power systems, the most critical factors are power density and efficiency. For this purpose, there have been very much ongoing studies to improve the power density on the RX side. Among various research, most frequently used types of methods involve derivation of output voltage using the physical quantity on the TX side while removing sensors on the RX side. However, in the modeling process to derive output voltage, they fail to properly reflect the parasite components of wireless power transfer and also due to the lack of measures in case of being out of the range of resonance frequency, there tends to be a high error in the output voltage which raises an issue. Therefore, this paper aims to suggest a model which reflects the parasite resistance components and the permeability rate of medium for the TX/RX pads of wireless power transfer systems. By reflecting winding losses and eddy current losses of TX/RX pads to a model, it is possible to reflect the parasite resistance components and using the Neumann formula, it is possible to reflect it to the medium between RX/TX pads. As a result, based on the derived model, it is possible to control the output voltage. Prototypes of hardware are designed and implemented for verifications. According to the computer simulation results and test results, output voltage estimates yield an error in the range of less than or equal to 8% and model-based output voltage control also shows the control range with errors of less than or equal to 5%.
- 28 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 32752-32758
Open AccessPrecise Modeling for Reducing Output Voltage Control Error of RX-Sensorless IPT System
This paper presents RX-Sensorless technologies required in a self-induced type of low power wireless power transfer system. Recently, apart from the fields of smartphone and electrical vehicles which have been arduously studied for application of wireless power transfer, wireless power transfer technologies are being applied to various fields. Among them, there is a very rapidly increasing demand for low power systems in displays, body implant medical devices, drones, electrical kickboards and so on. In order to acquire portability of RX side of low power systems, the most critical factors are power density and efficiency. For this purpose, there have been very much ongoing studies to improve the power density on the RX side. Among various research, most frequently used types of methods involve derivation of output voltage using the physical quantity on the TX side while removing sensors on the RX side. However, in the modeling process to derive output voltage, they fail to properly reflect the parasite components of wireless power transfer and also due to the lack of measures in case of being out of the range of resonance frequency, there tends to be a high error in the output voltage which raises an issue. Therefore, this paper aims to suggest a model which reflects the parasite resistance components and the permeability rate of medium for the TX/RX pads of wireless power transfer systems. By reflecting winding losses and eddy current losses of TX/RX pads to a model, it is possible to reflect the parasite resistance components and using the Neumann formula, it is possible to reflect it to the medium between RX/TX pads. As a result, based on the derived model, it is possible to control the output voltage. Prototypes of hardware are designed and implemented for verifications. According to the computer simulation results and test results, output voltage estimates yield an error in the range of less than or equal to 8% and model-based output voltage control also shows the control range with errors of less than or equal to 5%.
- 19 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 287-288
Stabilization of Phase and Frequency of an S-Band Magnetron by Injection Locking
We demonstrated feasibility of magnetron as a promising candidate for the microwave power units constituting a phased array system which enables long distance wireless power transfer, by stabilizing phase and frequency of an S-band magnetron.
- 19 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 287-288
Stabilization of Phase and Frequency of an S-Band Magnetron by Injection Locking
We demonstrated feasibility of magnetron as a promising candidate for the microwave power units constituting a phased array system which enables long distance wireless power transfer, by stabilizing phase and frequency of an S-band magnetron.
- Open Access
Optimal Design of Multi-Output LLC Resonant Converter with Independently Regulated Synchronous Single-Switched Power-Regulator
This paper presents a tightly regulated multi-output isolated converter that employs only an independently regulated synchronous Single-Switched Post-Regulator (SSPR). The proposed converter is a highly accurate single-ended secondary side post-regulator based on a Series Resonant Converter (SRC); furthermore, it has a voltage-doubler characteristic. The proposed post-regulator requires only one auxiliary switch, in contrast with a bulky and expensive non-isolated DC–DC converter. Moreover, the added voltage-doubler can tightly regulate the slave output current. In addition, the voltage-doubler can improve electromagnetic interference characteristics and reduce switching losses arising from the Zero Current Switching (ZCS) operation of all power switches. The validity of the proposed converter is verified using experimental results obtained via a prototype converter applicable to an LED 3D TV power supply.
Open AccessOptimal Design of Multi-Output LLC Resonant Converter with Independently Regulated Synchronous Single-Switched Power-Regulator
This paper presents a tightly regulated multi-output isolated converter that employs only an independently regulated synchronous Single-Switched Post-Regulator (SSPR). The proposed converter is a highly accurate single-ended secondary side post-regulator based on a Series Resonant Converter (SRC); furthermore, it has a voltage-doubler characteristic. The proposed post-regulator requires only one auxiliary switch, in contrast with a bulky and expensive non-isolated DC–DC converter. Moreover, the added voltage-doubler can tightly regulate the slave output current. In addition, the voltage-doubler can improve electromagnetic interference characteristics and reduce switching losses arising from the Zero Current Switching (ZCS) operation of all power switches. The validity of the proposed converter is verified using experimental results obtained via a prototype converter applicable to an LED 3D TV power supply.
- Open Access
- 27 December 2019
- Published by MDPI AG in Electronics
- Vol. 9 (1) , 38
CRM PFC Converter with New Valley Detection Method for Improving Power System Quality
High efficiency and the power factor of power converters, are very important factors which can improve power system quality. In particular, research on improving low efficiency and the power factor at light-load conditions is essential. A boost power factor correction (PFC) is most commonly used in home appliances, with several operations being at light-loads; the critical conduction mode (CRM) control, fixed ON-time control, and valley detection technique are mainly applied to PFC control. However, these control schemes have the following problems: (1) low efficiency, due to sudden increase in switching frequency at light-loads; and (2) low power factor, due to switching ON-time limitation. This paper presents a new valley detection method that can actively extend the fixed ON-time to overcome these problems. Furthermore, a new valley point detection circuit and an ON-time extension signal generation circuit are proposed and described in detail. The superiority of the proposed method is demonstrated via comparison with two existing CRM PFC control methods, namely fixed ON-time (conventional#1) and existing valley detection (conventional#2) methods. Experimental results at 20% load demonstrate that the proposed method shows an efficiency improvement of 2.1%, compared with the fixed ON-time strategy; and a power factor improvement of 34.9%, compared with the existing valley detection strategy.
- 27 December 2019
- Published by MDPI AG in Electronics
- Vol. 9 (1) , 38
Open AccessCRM PFC Converter with New Valley Detection Method for Improving Power System Quality
High efficiency and the power factor of power converters, are very important factors which can improve power system quality. In particular, research on improving low efficiency and the power factor at light-load conditions is essential. A boost power factor correction (PFC) is most commonly used in home appliances, with several operations being at light-loads; the critical conduction mode (CRM) control, fixed ON-time control, and valley detection technique are mainly applied to PFC control. However, these control schemes have the following problems: (1) low efficiency, due to sudden increase in switching frequency at light-loads; and (2) low power factor, due to switching ON-time limitation. This paper presents a new valley detection method that can actively extend the fixed ON-time to overcome these problems. Furthermore, a new valley point detection circuit and an ON-time extension signal generation circuit are proposed and described in detail. The superiority of the proposed method is demonstrated via comparison with two existing CRM PFC control methods, namely fixed ON-time (conventional#1) and existing valley detection (conventional#2) methods. Experimental results at 20% load demonstrate that the proposed method shows an efficiency improvement of 2.1%, compared with the fixed ON-time strategy; and a power factor improvement of 34.9%, compared with the existing valley detection strategy.