Valerio Pfister
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Valerio Pfister has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Mario Prato
ENEA—Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Brindisi Research Centre, Strada Statale 7, Appia, Km. 706, I-72100 Brindisi, Italy
6 shared publications - Michele Penza
ENEA—Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Laboratory Functional Materials and Technologies for Sustainable Applications, Brindisi Research Centre, Strada Statale 7, Appia, Km. 706, I-72100 Brindisi, Italy
6 shared publications - Domenico Suriano
ENEA—Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Lab. Functional Materials and Technologies for Sustainable Applications, Brindisi Research Center, I-72100 Brindisi, Italy
4 shared publications - Gennaro Cassano
ENEA—Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Laboratory Functional Materials and Technologies for Sustainable Applications, Brindisi Research Centre, Strada Statale 7, Appia, Km. 706, I-72100 Brindisi, Italy
4 shared publications - Angelo Tatì
Department of Sustainability, ENEA, 00123 Rome, Italy
2 shared publications - Vincenza Anna Maria Luprano
ENEA Brindisi Research Centre Cittadella della Ricerca S.S.7 km 706 Brindisi Italy
2 shared publications
Latest Publications
- Open Access
- 7 November 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 118 (1) , 89
An Anemometer Integration in a Low-Cost Air Quality Sensor System: A Real-World Case Study
The field deployment of low-cost air quality sensor systems enables enhanced spatial resolution in air quality monitoring. Although these sensor systems cannot achieve the same accuracy as regulatory monitoring stations, they can attain acceptable levels of confidence and provide Indicative Measurements as regulated by Ambient Air Quality EU Directive. The integration of an anemometer into a system can provide additional information for the classification of the measurement area, the identification of potential sources of pollutant emissions, and the assessment of the device’s operating conditions during measurement. In this study, the measurement capabilities of an Airbox, a low-cost air quality sensor system, were extended through the integration of a DW6410 anemometer (Davis Instruments). The Airbox, designed to transmit data in real-time or near real-time to servers and IoT platforms, was deployed for a duration of 4 months, from October 2021 to February 2022, within the airport area of Grottaglie (Southern Italy). The anemometric measurements and particulate concentration data (PM2.5 and PM10, measured by NextPM sensor, Tera Sensor) were integrated and compared to meteorological open data and data from a regulatory regional air quality control network located in the area around the airport.
- 7 November 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 118 (1) , 89
Open AccessAn Anemometer Integration in a Low-Cost Air Quality Sensor System: A Real-World Case Study
The field deployment of low-cost air quality sensor systems enables enhanced spatial resolution in air quality monitoring. Although these sensor systems cannot achieve the same accuracy as regulatory monitoring stations, they can attain acceptable levels of confidence and provide Indicative Measurements as regulated by Ambient Air Quality EU Directive. The integration of an anemometer into a system can provide additional information for the classification of the measurement area, the identification of potential sources of pollutant emissions, and the assessment of the device’s operating conditions during measurement. In this study, the measurement capabilities of an Airbox, a low-cost air quality sensor system, were extended through the integration of a DW6410 anemometer (Davis Instruments). The Airbox, designed to transmit data in real-time or near real-time to servers and IoT platforms, was deployed for a duration of 4 months, from October 2021 to February 2022, within the airport area of Grottaglie (Southern Italy). The anemometric measurements and particulate concentration data (PM2.5 and PM10, measured by NextPM sensor, Tera Sensor) were integrated and compared to meteorological open data and data from a regulatory regional air quality control network located in the area around the airport.
- Open Access
- 28 October 2025
- Published by MDPI AG in Chemosensors
- Vol. 13 (11) , 380
Networked Low-Cost Sensor Systems for Urban Air Quality Monitoring: A Long-Term Use-Case in Bari (Italy)
A sensor network based on 10 stationary nodes distributed in Bari (Southern Italy) has been deployed for urban air quality (AQ) monitoring. The low-cost sensor systems have been installed in specific sites (e.g., buildings, offices, schools, streets, ports, and airports) to enhance environmental awareness of the citizens and to supplement the expensive official air-monitoring stations with cost-effective sensor nodes at high spatial and temporal resolution. Continuous measurements were performed by low-cost electrochemical gas sensors (CO, NO2, O3), optical particle counter (PM10), and NDIR infrared sensor (CO2), including micro-sensors for temperature and relative humidity. The sensors are operated to assess the performance during a campaign (July 2015–December 2017) of several months for citizen science in sustainable smart cities. Typical values of CO2, measured by distributed nodes, varied from 312 to 494 ppm (2016), and from 371 to 527 ppm (2017), depending on seasonal micro-climate change and site-specific conditions. The results of the AQ-monitoring long-term campaign for selected sensor nodes are presented with a relative error of 26.2% (PM10), 21.7% (O3), 25.5% (NO2), and 79.4% (CO). These interesting results suggest a partial compliance, excluding CO, with Data Quality Objectives (DQO) by the European Air Quality Directive (2008/50/EC) for Indicative (Informative) Measurements.
- 28 October 2025
- Published by MDPI AG in Chemosensors
- Vol. 13 (11) , 380
Open AccessNetworked Low-Cost Sensor Systems for Urban Air Quality Monitoring: A Long-Term Use-Case in Bari (Italy)
A sensor network based on 10 stationary nodes distributed in Bari (Southern Italy) has been deployed for urban air quality (AQ) monitoring. The low-cost sensor systems have been installed in specific sites (e.g., buildings, offices, schools, streets, ports, and airports) to enhance environmental awareness of the citizens and to supplement the expensive official air-monitoring stations with cost-effective sensor nodes at high spatial and temporal resolution. Continuous measurements were performed by low-cost electrochemical gas sensors (CO, NO2, O3), optical particle counter (PM10), and NDIR infrared sensor (CO2), including micro-sensors for temperature and relative humidity. The sensors are operated to assess the performance during a campaign (July 2015–December 2017) of several months for citizen science in sustainable smart cities. Typical values of CO2, measured by distributed nodes, varied from 312 to 494 ppm (2016), and from 371 to 527 ppm (2017), depending on seasonal micro-climate change and site-specific conditions. The results of the AQ-monitoring long-term campaign for selected sensor nodes are presented with a relative error of 26.2% (PM10), 21.7% (O3), 25.5% (NO2), and 79.4% (CO). These interesting results suggest a partial compliance, excluding CO, with Data Quality Objectives (DQO) by the European Air Quality Directive (2008/50/EC) for Indicative (Informative) Measurements.
- Open Access
- 1 October 2025
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 30 (10)
Direct and Indirect Ultrasonic Measurements on Plastered and Unplastered Concrete Columns: A Case Study of an Inhabited Building in Italy
Assessing the condition of concrete in place is an important part of building safety verification programmes. For the study of existing concrete structures, it is important to know the strength of different elements. The assessment of the compressive strength of structures can be carried out by destructive coring tests in varying quantities and calibrated indirect methods, combining destructive coring with non- or semi-destructive techniques. When planning ultrasonic indirect measurements, it must be taken into account that in inhabited houses the columns are covered with plaster that often cannot be easily removed and restored (even more so if, in addition to being a protective covering, it also has a decorative function): indirect measurements can be performed, but it is necessary to evaluate the impact of the presence of plaster. An analytical model has been developed to predict the surface wave propagation velocities in concrete columns, both with and without a plaster covering. The aim is to support the interpretation of time-of-flight measurements in indirect ultrasonic testing.
- 1 October 2025
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 30 (10)
Open AccessDirect and Indirect Ultrasonic Measurements on Plastered and Unplastered Concrete Columns: A Case Study of an Inhabited Building in Italy
Assessing the condition of concrete in place is an important part of building safety verification programmes. For the study of existing concrete structures, it is important to know the strength of different elements. The assessment of the compressive strength of structures can be carried out by destructive coring tests in varying quantities and calibrated indirect methods, combining destructive coring with non- or semi-destructive techniques. When planning ultrasonic indirect measurements, it must be taken into account that in inhabited houses the columns are covered with plaster that often cannot be easily removed and restored (even more so if, in addition to being a protective covering, it also has a decorative function): indirect measurements can be performed, but it is necessary to evaluate the impact of the presence of plaster. An analytical model has been developed to predict the surface wave propagation velocities in concrete columns, both with and without a plaster covering. The aim is to support the interpretation of time-of-flight measurements in indirect ultrasonic testing.
- Open Access
Holistic Assessment for Social Housing Retrofitting: Integrating Seismic, Energy, and Social Aspects in the REHOUSE Project
There are many existing buildings for which seismic rehabilitation interventions are required, especially in earthquake-prone areas like Italy. At the same time, the huge energy cost increase in Europe highlights the need for sustainable techniques that are able to increase the energy efficiency of buildings. These issues are even more significant for weak social groups living in social housing buildings, often in poor and vulnerable conditions. In order to address the solution regarding building renovations from the social, structural, and energy efficiency perspectives, in the framework of the Horizon Europe REHOUSE (Renovation packagEs for HOlistic improvement of EU’s bUildingS Efficiency, maximizing RES generation and cost-effectiveness) Project, this paper proposes an integrated methodology of building assessment that was tested on a social housing building in Margherita di Savoia, a small town of Apulia Region, Italy. In addition to the structural and energy aspects, the social one is particularly important since the building is located in the “Capitanata Area”, considered to be one of the most socially vulnerable areas in Italy. For this reason, an assessment methodology must consider reducing the overall impact of the assessment activities while explaining to tenants the purpose of the assessment and future renovation actions, maintaining the accuracy of the assessment results. Therefore, this study outlines an assessment methodology, demonstrated through its application to the case study building, that integrates the structural, energy, and social aspects, showing that the tenants’ involvement is also crucial for the technical evaluations. The final result is a low-impact approach for the building knowledge gathering needed to start a deep renovation intervention in social housing.
Open AccessHolistic Assessment for Social Housing Retrofitting: Integrating Seismic, Energy, and Social Aspects in the REHOUSE Project
There are many existing buildings for which seismic rehabilitation interventions are required, especially in earthquake-prone areas like Italy. At the same time, the huge energy cost increase in Europe highlights the need for sustainable techniques that are able to increase the energy efficiency of buildings. These issues are even more significant for weak social groups living in social housing buildings, often in poor and vulnerable conditions. In order to address the solution regarding building renovations from the social, structural, and energy efficiency perspectives, in the framework of the Horizon Europe REHOUSE (Renovation packagEs for HOlistic improvement of EU’s bUildingS Efficiency, maximizing RES generation and cost-effectiveness) Project, this paper proposes an integrated methodology of building assessment that was tested on a social housing building in Margherita di Savoia, a small town of Apulia Region, Italy. In addition to the structural and energy aspects, the social one is particularly important since the building is located in the “Capitanata Area”, considered to be one of the most socially vulnerable areas in Italy. For this reason, an assessment methodology must consider reducing the overall impact of the assessment activities while explaining to tenants the purpose of the assessment and future renovation actions, maintaining the accuracy of the assessment results. Therefore, this study outlines an assessment methodology, demonstrated through its application to the case study building, that integrates the structural, energy, and social aspects, showing that the tenants’ involvement is also crucial for the technical evaluations. The final result is a low-impact approach for the building knowledge gathering needed to start a deep renovation intervention in social housing.
- Open Access
- 26 September 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 48 (1) , 27
Field Performance Evaluation of Air Quality Low-Cost Sensors Deployed in a Near-City Space-Airport
Air pollution is a current problem for the environment and public health. Its impact needs to be monitored in urban agglomerates and critical hot spots such as airports. Green aviation with low air emissions is a sustainable goal for the future. The air pollutants are monitored by governmental agencies that employ regulatory monitoring stations, which are very accurate but also very expensive, bulky, and maintenance demands. On the contrary, low-cost sensor systems can offer a proper solution to cover large areas at high spatial-temporal resolution. However, the low-cost air quality sensors are less accurate than reference analyzers operating in the regulatory stations. To enhance the sensor accuracy, field calibration, and data correction with reference instrumentation is a valid strategy to improve sensor data quality. In this study, a sensor system with a selected set of air quality gas sensors (NO2, O3) and particulate matter (PM10, PM2.5) has been developed and deployed in a near-city space-airport at Grottaglie (Southern Italy) to perform measurements in a period of 4 months, from October 2021 to February 2022. The sensor units installed in the Airbox system used for this measurements campaign are the GS+4NO2 (DD Scientific) for NO2 measurements, the O3-3E1F (City Technology, Sensoric) for O3 measurements, and the NextPM (Tera Sensor) for PM10 and PM2.5 measurements. Data gathered by the low-cost air quality sensors have been compared to reference instrumentations both co-located (ca. 1 m distance) together with low-cost sensors (PM10, R2 > 0.87; PM2.5, R2 > 0.50) and a distributed regulatory network of 14 environmental stations operating in the local area around space-airport at a distance ranging from 3 to 26 km.
- 26 September 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 48 (1) , 27
Open AccessField Performance Evaluation of Air Quality Low-Cost Sensors Deployed in a Near-City Space-Airport
Air pollution is a current problem for the environment and public health. Its impact needs to be monitored in urban agglomerates and critical hot spots such as airports. Green aviation with low air emissions is a sustainable goal for the future. The air pollutants are monitored by governmental agencies that employ regulatory monitoring stations, which are very accurate but also very expensive, bulky, and maintenance demands. On the contrary, low-cost sensor systems can offer a proper solution to cover large areas at high spatial-temporal resolution. However, the low-cost air quality sensors are less accurate than reference analyzers operating in the regulatory stations. To enhance the sensor accuracy, field calibration, and data correction with reference instrumentation is a valid strategy to improve sensor data quality. In this study, a sensor system with a selected set of air quality gas sensors (NO2, O3) and particulate matter (PM10, PM2.5) has been developed and deployed in a near-city space-airport at Grottaglie (Southern Italy) to perform measurements in a period of 4 months, from October 2021 to February 2022. The sensor units installed in the Airbox system used for this measurements campaign are the GS+4NO2 (DD Scientific) for NO2 measurements, the O3-3E1F (City Technology, Sensoric) for O3 measurements, and the NextPM (Tera Sensor) for PM10 and PM2.5 measurements. Data gathered by the low-cost air quality sensors have been compared to reference instrumentations both co-located (ca. 1 m distance) together with low-cost sensors (PM10, R2 > 0.87; PM2.5, R2 > 0.50) and a distributed regulatory network of 14 environmental stations operating in the local area around space-airport at a distance ranging from 3 to 26 km.
- Open Access
- 18 September 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 48 (1) , 62
Application of Low-Cost Sensors in Stationary and Mobile Nodes for Urban Air Quality Index Monitoring
The air quality in modern cities and urban areas is strongly affected by chemical pollutants such as toxic gases, volatile organic compounds, and particulate matter. They are monitored by governmental agencies using regulatory monitoring stations, which are highly accurate, but also very expensive, bulky, and maintenance demanding. There is a compulsory need to monitor air quality at high spatial–temporal resolution in smart cities for public health protection and environmental sustainability. Properly calibrated low-cost and low-accuracy sensors are usually deployed in stationary and mobile nodes for urban air quality monitoring. A simple indicator of the current status of urban air pollution is the Air Quality Index (AQI) used to communicate the pollution level under the time-changing trend of a specific pollutant. In this study, continuous measurements have been performed in the city of Bari (southern Italy) by electrochemical gas sensors (NO2, O3, CO), optical particle counters (OPC) for particulate matter (PM10), and NDIR infrared sensors (CO2), including microsensors for temperature and relative humidity. The sensors have been installed in stationary nodes located in urban sites and in a mobile node mounted on a public bus moving on urban routes. AQI data gathered by the low-cost sensors have been compared with reference instrumentations as a case study of citizen science.
- 18 September 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 48 (1) , 62
Open AccessApplication of Low-Cost Sensors in Stationary and Mobile Nodes for Urban Air Quality Index Monitoring
The air quality in modern cities and urban areas is strongly affected by chemical pollutants such as toxic gases, volatile organic compounds, and particulate matter. They are monitored by governmental agencies using regulatory monitoring stations, which are highly accurate, but also very expensive, bulky, and maintenance demanding. There is a compulsory need to monitor air quality at high spatial–temporal resolution in smart cities for public health protection and environmental sustainability. Properly calibrated low-cost and low-accuracy sensors are usually deployed in stationary and mobile nodes for urban air quality monitoring. A simple indicator of the current status of urban air pollution is the Air Quality Index (AQI) used to communicate the pollution level under the time-changing trend of a specific pollutant. In this study, continuous measurements have been performed in the city of Bari (southern Italy) by electrochemical gas sensors (NO2, O3, CO), optical particle counters (OPC) for particulate matter (PM10), and NDIR infrared sensors (CO2), including microsensors for temperature and relative humidity. The sensors have been installed in stationary nodes located in urban sites and in a mobile node mounted on a public bus moving on urban routes. AQI data gathered by the low-cost sensors have been compared with reference instrumentations as a case study of citizen science.
- Open Access
- 5 December 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 898
Wireless Sensors Network Monitoring of Saharan Dust Events in Bari, Italy
A sensors network based on 8 stationary nodes distributed in Bari (Southern Italy) has been deployed for urban air quality monitoring during advection events of Saharan dust in the period 2015–2017. The low-cost sensor-systems have been installed in specific sites (buildings, offices, schools, streets, airport) to assess the PM10 concentration at high spatial and temporal resolution in order to supplement the expensive official air monitoring stations for citizen science purposes. Continuous measurements were performed by a cost-effective optical particle counter (PM10), including temperature and relative humidity sensors. They are operated to assess the performance during a long-term campaign (July 2015–December 2017) of 30 months for smart cities applications. The sensor data quality has been evaluated by comparison to the reference data of the 9 Air Quality Monitoring Stations (AQMS), managed by local environmental agency (ARPA-Puglia) in the Bari city.
- 5 December 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 898
Open AccessWireless Sensors Network Monitoring of Saharan Dust Events in Bari, Italy
A sensors network based on 8 stationary nodes distributed in Bari (Southern Italy) has been deployed for urban air quality monitoring during advection events of Saharan dust in the period 2015–2017. The low-cost sensor-systems have been installed in specific sites (buildings, offices, schools, streets, airport) to assess the PM10 concentration at high spatial and temporal resolution in order to supplement the expensive official air monitoring stations for citizen science purposes. Continuous measurements were performed by a cost-effective optical particle counter (PM10), including temperature and relative humidity sensors. They are operated to assess the performance during a long-term campaign (July 2015–December 2017) of 30 months for smart cities applications. The sensor data quality has been evaluated by comparison to the reference data of the 9 Air Quality Monitoring Stations (AQMS), managed by local environmental agency (ARPA-Puglia) in the Bari city.
- Open Access
- 8 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 573
Urban Air Quality Monitoring with Networked Low-Cost Sensor-Systems
A sensors network based on 11 nodes (10 stationary and 1 mobile mounted on public bus) distributed in Bari (Italy) has been deployed for urban air quality (AQ) monitoring. The low-cost sensor-systems have been installed in specific sites (buildings, offices, schools, streets, port, airport) to enhance environmental awareness of the citizens and to supplement the expensive official air monitoring stations with cost-effective sensor-nodes at high spatial and temporal resolution. Continuous measurements were performed by low-cost electrochemical gas sensors (CO, NO2, O3, SO2), optical particle counter (PM1.0, PM2.5, PM10), NDIR infrared sensor (CO2), photo-ionisation detector (total VOCs), including microsensors for temperature and relative humidity. The sensors are running to assess the performance during a campaign (June 2015–December 2017) of several months for citizen science in sustainable smart cities. The air quality index (AQI) for a given pollutant has been measured and compared to the public reference environmental data. The results of the AQ monitoring long-term campaign for selected sensor-nodes are presented.
- 8 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 573
Open AccessUrban Air Quality Monitoring with Networked Low-Cost Sensor-Systems
A sensors network based on 11 nodes (10 stationary and 1 mobile mounted on public bus) distributed in Bari (Italy) has been deployed for urban air quality (AQ) monitoring. The low-cost sensor-systems have been installed in specific sites (buildings, offices, schools, streets, port, airport) to enhance environmental awareness of the citizens and to supplement the expensive official air monitoring stations with cost-effective sensor-nodes at high spatial and temporal resolution. Continuous measurements were performed by low-cost electrochemical gas sensors (CO, NO2, O3, SO2), optical particle counter (PM1.0, PM2.5, PM10), NDIR infrared sensor (CO2), photo-ionisation detector (total VOCs), including microsensors for temperature and relative humidity. The sensors are running to assess the performance during a campaign (June 2015–December 2017) of several months for citizen science in sustainable smart cities. The air quality index (AQI) for a given pollutant has been measured and compared to the public reference environmental data. The results of the AQ monitoring long-term campaign for selected sensor-nodes are presented.