Supannika Klangphukhiew
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Supannika Klangphukhiew has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Rina Patramanon
Khon Kaen University
3 shared publications - Sirinan Kulchat
Materials Chemistry Research Center Department of Chemistry and Center of Excellence for Innovation in Chemistry Faculty of Science Khon Kaen University Khon Kaen 40002 Thailand
2 shared publications - Apichart Saenchoopa
Department of Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen 40002, Thailand
1 shared publication - Chanon Talodthaisong
Department of Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen 40002, Thailand
1 shared publication - Jureerut Daduang
Department of Clinical Chemistry, Faculty of Associated Medical Sciences, Khon Kaen University, Khon Kaen 40002, Thailand
1 shared publication - Karnpimon Krorakai
Department of Biochemistry, Faculty of Science, Khon Kaen University, Khon Kaen 40000, Thailand
1 shared publication
Latest Publications
- Open Access
- 23 September 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (10) , 351
A Disposable Electrochemical Biosensor Based on Screen-Printed Carbon Electrodes Modified with Silver Nanowires/HPMC/Chitosan/Urease for the Detection of Mercury (II) in Water
This work describes the facile preparation of a disposable electrochemical biosensor for the detection of Hg(II) in water by modifying the surface of a screen-printed carbon electrode (SPCE). The surface modification consists of the immobilization of a composite layer of silver nanowires, hydroxymethyl propyl cellulose, chitosan, and urease (AgNWs/HPMC/CS/Urease). The presence of the composite was confirmed by scanning electron microscopy (SEM) and its excellent conductivity, due chiefly to the electrical properties of silver nanowires, enhanced the sensitivity of the biosensor. Under optimum conditions, the modified SPCE biosensor showed excellent performance for the detection of Hg(II) ions, with an incubation time of 10 min and a linear sensitivity range of 5–25 µM. The limit of detection (LOD) and limit of quantitation (LOQ) were observed to be 3.94 µM and 6.50 µM, respectively. In addition, the disposable and portable biosensor exhibited excellent recoveries for the detection of Hg(II) ions in commercial drinking water samples (101.62–105.26%). The results are correlated with those obtained from inductively coupled plasma optical emission spectrometry (ICP-OES), indicating that our developed sensor is a reliable method for detection of Hg(II) in real water samples. The developed sensor device is a simple, effective, portable, low cost, and user-friendly platform for real-time detection of heavy metal ions in field measurements with potential for other biomedical applications in the future.
- 23 September 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (10) , 351
Open AccessA Disposable Electrochemical Biosensor Based on Screen-Printed Carbon Electrodes Modified with Silver Nanowires/HPMC/Chitosan/Urease for the Detection of Mercury (II) in Water
This work describes the facile preparation of a disposable electrochemical biosensor for the detection of Hg(II) in water by modifying the surface of a screen-printed carbon electrode (SPCE). The surface modification consists of the immobilization of a composite layer of silver nanowires, hydroxymethyl propyl cellulose, chitosan, and urease (AgNWs/HPMC/CS/Urease). The presence of the composite was confirmed by scanning electron microscopy (SEM) and its excellent conductivity, due chiefly to the electrical properties of silver nanowires, enhanced the sensitivity of the biosensor. Under optimum conditions, the modified SPCE biosensor showed excellent performance for the detection of Hg(II) ions, with an incubation time of 10 min and a linear sensitivity range of 5–25 µM. The limit of detection (LOD) and limit of quantitation (LOQ) were observed to be 3.94 µM and 6.50 µM, respectively. In addition, the disposable and portable biosensor exhibited excellent recoveries for the detection of Hg(II) ions in commercial drinking water samples (101.62–105.26%). The results are correlated with those obtained from inductively coupled plasma optical emission spectrometry (ICP-OES), indicating that our developed sensor is a reliable method for detection of Hg(II) in real water samples. The developed sensor device is a simple, effective, portable, low cost, and user-friendly platform for real-time detection of heavy metal ions in field measurements with potential for other biomedical applications in the future.
- Open Access
- 3 January 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (1) , 392
Smartphone-Based NFC Potentiostat for Wireless Electrochemical Sensing
Most electrochemical sensing requires affordable, portable and easy-to-use electrochemical devices for use in point-of-care testing and resource-limited settings. This work presents the design and evaluates the analytical performance of a near-field communication (NFC) potentiostat, a flat card-sized electrochemical device containing a microchip for electrical analysis and an NFC antenna for smartphone connection. The NFC interface is a wireless connection between the microchip and smartphone to simplify measuring units and make the potentiostat into a passive operated device, running without a battery. The proposed potentiostat can perform the common electrochemical techniques including cyclic voltammetry and chronoamperometry with a current range and voltage range of ±20 µA and ±0.8 V. The performance of the NFC potentiostat is compared to a commercial benchtop potentiostat using ferricyanide as a standard solution. The results show that the NFC potentiostat is comparable to a commercial benchtop potentiostat for both cyclic voltammetry and chronoamperometry measurements. The application of the proposed potentiostat is demonstrated by measuring ascorbic acid concentration. As described, the NFC potentiostat, which is compatible with a smartphone, is low-cost, small in size and user-friendly. Thus, the device can be developed for on-site measurement to apply in various fields.
- 3 January 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (1) , 392
Open AccessSmartphone-Based NFC Potentiostat for Wireless Electrochemical Sensing
Most electrochemical sensing requires affordable, portable and easy-to-use electrochemical devices for use in point-of-care testing and resource-limited settings. This work presents the design and evaluates the analytical performance of a near-field communication (NFC) potentiostat, a flat card-sized electrochemical device containing a microchip for electrical analysis and an NFC antenna for smartphone connection. The NFC interface is a wireless connection between the microchip and smartphone to simplify measuring units and make the potentiostat into a passive operated device, running without a battery. The proposed potentiostat can perform the common electrochemical techniques including cyclic voltammetry and chronoamperometry with a current range and voltage range of ±20 µA and ±0.8 V. The performance of the NFC potentiostat is compared to a commercial benchtop potentiostat using ferricyanide as a standard solution. The results show that the NFC potentiostat is comparable to a commercial benchtop potentiostat for both cyclic voltammetry and chronoamperometry measurements. The application of the proposed potentiostat is demonstrated by measuring ascorbic acid concentration. As described, the NFC potentiostat, which is compatible with a smartphone, is low-cost, small in size and user-friendly. Thus, the device can be developed for on-site measurement to apply in various fields.
- Open Access
- 16 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 538
Cortisol Stress Biosensor Based on Molecular Imprinted Polymer
The molecular imprinted polymer (MIP) technique was applied to receptors that could imitate the performance of natural anti-cortisol antibody with high stability. Cortisol-molecular imprinted polymer (cortisol-MIP) was obtained using the multi-step swelling and polymerization protocol with cortisol as a target molecule. The suitable ratio of methacrylic acid:acrylamide :cortisol which allowed the formation of 642.3 ± 35.8 nm homogenous particles was 2:1:1. Cortisol-MIP was integrated to the sensor. It was coated on the disposable screen-printed carbon electrode (SPCE) for portable electrochemical analysis. The physical properties of Cortisol-MIP were characterized by means of electron microscope techniques. The binding characteristics were evaluated via covalent patterns changing in FTIR spectra which were related to voltammetry responses. The SPCE modified with cortisol-MIP was able to perform various detection ranges from 1.28 to 20 nM and the high selectivity compared to three other glucocorticoid analogs.
- 16 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 538
Open AccessCortisol Stress Biosensor Based on Molecular Imprinted Polymer
The molecular imprinted polymer (MIP) technique was applied to receptors that could imitate the performance of natural anti-cortisol antibody with high stability. Cortisol-molecular imprinted polymer (cortisol-MIP) was obtained using the multi-step swelling and polymerization protocol with cortisol as a target molecule. The suitable ratio of methacrylic acid:acrylamide :cortisol which allowed the formation of 642.3 ± 35.8 nm homogenous particles was 2:1:1. Cortisol-MIP was integrated to the sensor. It was coated on the disposable screen-printed carbon electrode (SPCE) for portable electrochemical analysis. The physical properties of Cortisol-MIP were characterized by means of electron microscope techniques. The binding characteristics were evaluated via covalent patterns changing in FTIR spectra which were related to voltammetry responses. The SPCE modified with cortisol-MIP was able to perform various detection ranges from 1.28 to 20 nM and the high selectivity compared to three other glucocorticoid analogs.