Anthony J. Boyle
Research Subjects
Anthony J. Boyle has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Duncan J. Maitland
Department of Biomedical Engineering, Texas A&M University, College Station, USA
2 shared publications - David F. Kallmes
Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905
1 shared publication Douglas Follmer
Department of Biomedical Engineering; Texas A&M University; 3120 TAMU College Station Texas 77843
1 shared publication- Jennifer N. Rodriguez
Department of Biomedical Engineering, Texas A&M University, 3120 TAMU, College Station, Texas, 77843
1 shared publication - Jesse Bryant
Department of Biomedical Engineering; Texas A&M University; 3120 TAMU College Station Texas 77843
1 shared publication - John Horn
Department of Biomedical Engineering; Texas A&M University; 3120 TAMU College Station Texas 77843
1 shared publication
Latest Publications
- Open Access
Increased X-ray Visualization of Shape Memory Polymer Foams by Chemical Incorporation of Iodine Motifs
Shape memory polymers can be programmed into a secondary geometry and recovered to their primary geometry with the application of a controlled stimulus. Porous shape memory polymer foam scaffolds that respond to body temperature show particular promise for embolic medical applications. A limitation for the minimally invasive delivery of these materials is an inherent lack of X-ray contrast. In this work, a triiodobenzene containing a monomer was incorporated into a shape memory polymer foam material system to chemically impart X-ray visibility and increase material toughness. Composition and process changes enabled further control over material density and thermomechanical properties. The proposed material system demonstrates a wide range of tailorable functional properties for the design of embolic medical devices, including X-ray visibility, expansion rate, and porosity. Enhanced visualization of these materials can improve the acute performance of medical devices used to treat vascular malformations, and the material porosity provides a healing scaffold for durable occlusion.
Open AccessIncreased X-ray Visualization of Shape Memory Polymer Foams by Chemical Incorporation of Iodine Motifs
Shape memory polymers can be programmed into a secondary geometry and recovered to their primary geometry with the application of a controlled stimulus. Porous shape memory polymer foam scaffolds that respond to body temperature show particular promise for embolic medical applications. A limitation for the minimally invasive delivery of these materials is an inherent lack of X-ray contrast. In this work, a triiodobenzene containing a monomer was incorporated into a shape memory polymer foam material system to chemically impart X-ray visibility and increase material toughness. Composition and process changes enabled further control over material density and thermomechanical properties. The proposed material system demonstrates a wide range of tailorable functional properties for the design of embolic medical devices, including X-ray visibility, expansion rate, and porosity. Enhanced visualization of these materials can improve the acute performance of medical devices used to treat vascular malformations, and the material porosity provides a healing scaffold for durable occlusion.
- 7 July 2014
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 103 (4) , 1577-1594
Design and biocompatibility of endovascular aneurysm filling devices
The rupture of an intracranial aneurysm, which can result in severe mental disabilities or death, affects approximately 30,000 people in the United States annually. The traditional surgical method of treating these arterial malformations involves a full craniotomy procedure, wherein a clip is placed around the aneurysm neck. In recent decades, research and device development have focused on new endovascular treatment methods to occlude the aneurysm void space. These methods, some of which are currently in clinical use, utilize metal, polymeric, or hybrid devices delivered via catheter to the aneurysm site. In this review, we present several such devices, including those that have been approved for clinical use, and some that are currently in development. We present several design requirements for a successful aneurysm filling device and discuss the success or failure of current and past technologies. We also present novel polymeric‐based aneurysm filling methods that are currently being tested in animal models that could result in superior healing. © 2014 Wiley Periodicals, Inc. J Biomed Mater Res Part A 103A: 1577–1594, 2015.
- 7 July 2014
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 103 (4) , 1577-1594
Design and biocompatibility of endovascular aneurysm filling devices
The rupture of an intracranial aneurysm, which can result in severe mental disabilities or death, affects approximately 30,000 people in the United States annually. The traditional surgical method of treating these arterial malformations involves a full craniotomy procedure, wherein a clip is placed around the aneurysm neck. In recent decades, research and device development have focused on new endovascular treatment methods to occlude the aneurysm void space. These methods, some of which are currently in clinical use, utilize metal, polymeric, or hybrid devices delivered via catheter to the aneurysm site. In this review, we present several such devices, including those that have been approved for clinical use, and some that are currently in development. We present several design requirements for a successful aneurysm filling device and discuss the success or failure of current and past technologies. We also present novel polymeric‐based aneurysm filling methods that are currently being tested in animal models that could result in superior healing. © 2014 Wiley Periodicals, Inc. J Biomed Mater Res Part A 103A: 1577–1594, 2015.