Martijn H. Goedbloed
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Martijn H. Goedbloed has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Marcel A. G. Zevenbergen
Holst Centre, IMEC The Netherlands, 5656AE 31 Eindhoven, The Netherlands
2 shared publications - Greja J. A. M. Brom-Verheijden
Holst Centre, IMEC The Netherlands, 5656AE 31 Eindhoven, The Netherlands
1 shared publication - Van Anh T. Dam
Holst Centre/imec, 5656 AE Eindhoven, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 10 December 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 797
A Microfabricated 4-Electrode Conductivity Sensor with Enhanced Range
Conductivity is a routinely measured parameter to assess impurities in water. Changing the geometry from parallel plate electrodes to planar microfabricated dual-band or interdigitated electrodes, these sensors could be miniaturized. Based on this approach, we designed 2-electrode conductivity sensors and compared their performance with a commercially available device. Adding another electrode pair (either as dual-band or meandering between interdigitated electrodes), a 4-electrode sensor was formed for which the measuring range could be enhanced to 3 × 10−6–12 × 10−3 S/cm.
- 10 December 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 797
Open AccessA Microfabricated 4-Electrode Conductivity Sensor with Enhanced Range
Conductivity is a routinely measured parameter to assess impurities in water. Changing the geometry from parallel plate electrodes to planar microfabricated dual-band or interdigitated electrodes, these sensors could be miniaturized. Based on this approach, we designed 2-electrode conductivity sensors and compared their performance with a commercially available device. Adding another electrode pair (either as dual-band or meandering between interdigitated electrodes), a 4-electrode sensor was formed for which the measuring range could be enhanced to 3 × 10−6–12 × 10−3 S/cm.
- Open Access
- 25 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 464
Solid-Contact Reference Electrode for Ion-Selective Sensors
This work presents a flexible miniaturized ion-selective sensor consisting of a solid-contact reference electrode (RE) and ion-selective electrodes (ISE) fabricated on the same foil. The flexible ion sensor was based on AgCl electrodes screen printed on polyethylene terephthalate foil. The RE was formed by casting a mixture of plasticized polyvinylchloride (PVC) and KCl on the AgCl electrode. The ISE consisted of a stack of AgCl electrode, cellulose gel layer loaded with 0.1 M KCl, and plasticized PVC based ion-selective membrane containing ionophores. The flexible ion sensor showed a sensitivity close to the Nernstian value in a biological relevant range.
- 25 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 464
Open AccessSolid-Contact Reference Electrode for Ion-Selective Sensors
This work presents a flexible miniaturized ion-selective sensor consisting of a solid-contact reference electrode (RE) and ion-selective electrodes (ISE) fabricated on the same foil. The flexible ion sensor was based on AgCl electrodes screen printed on polyethylene terephthalate foil. The RE was formed by casting a mixture of plasticized polyvinylchloride (PVC) and KCl on the AgCl electrode. The ISE consisted of a stack of AgCl electrode, cellulose gel layer loaded with 0.1 M KCl, and plasticized PVC based ion-selective membrane containing ionophores. The flexible ion sensor showed a sensitivity close to the Nernstian value in a biological relevant range.