Eva Šafaříková
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Eva Šafaříková has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Lukáš Kubala
International Clinical Research Center, St. Anne’s University Hospital , Pekarska 53
3 shared publications - Martin Vala
Brno university of Technology, Faculty of Chemistry, Materials Research Centre, Purkyňova 464/118, Brno 612 00, Czech Republic
3 shared publications - Stanislav Stříteský
Brno University of Technology
3 shared publications Jan Víteček
2 shared publications- Jan Víteček
International Clinical Research Center, St. Anne’s University Hospital , Pekarska 53
2 shared publications Martin Weiter
2 shared publications
Latest Publications
- Open Access
- 20 January 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (3) , 1107
Conductive Polymer PEDOT:PSS-Based Platform for Embryonic Stem-Cell Differentiation
Organic semiconductors are constantly gaining interest in regenerative medicine. Their tunable physico-chemical properties, including electrical conductivity, are very promising for the control of stem-cell differentiation. However, their use for combined material-based and electrical stimulation remains largely underexplored. Therefore, we carried out a study on whether a platform based on the conductive polymer poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) can be beneficial to the differentiation of mouse embryonic stem cells (mESCs). The platform was prepared using the layout of a standard 24-well cell-culture plate. Polyethylene naphthalate foil served as the substrate for the preparation of interdigitated gold electrodes by physical vapor deposition. The PEDOT:PSS pattern was fabricated by precise screen printing over the gold electrodes. The PEDOT:PSS platform was able to produce higher electrical current with the pulsed-direct-current (DC) electrostimulation mode (1 Hz, 200 mV/mm, 100 ms pulse duration) compared to plain gold electrodes. There was a dominant capacitive component. In proof-of-concept experiments, mESCs were able to respond to such electrostimulation by membrane depolarization and elevation of cytosolic calcium. Further, the PEDOT:PSS platform was able to upregulate cardiomyogenesis and potentially inhibit early neurogenesis per se with minor contribution of electrostimulation. Hence, the present work highlights the large potential of PEDOT:PSS in regenerative medicine.
- 20 January 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (3) , 1107
Open AccessConductive Polymer PEDOT:PSS-Based Platform for Embryonic Stem-Cell Differentiation
Organic semiconductors are constantly gaining interest in regenerative medicine. Their tunable physico-chemical properties, including electrical conductivity, are very promising for the control of stem-cell differentiation. However, their use for combined material-based and electrical stimulation remains largely underexplored. Therefore, we carried out a study on whether a platform based on the conductive polymer poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) can be beneficial to the differentiation of mouse embryonic stem cells (mESCs). The platform was prepared using the layout of a standard 24-well cell-culture plate. Polyethylene naphthalate foil served as the substrate for the preparation of interdigitated gold electrodes by physical vapor deposition. The PEDOT:PSS pattern was fabricated by precise screen printing over the gold electrodes. The PEDOT:PSS platform was able to produce higher electrical current with the pulsed-direct-current (DC) electrostimulation mode (1 Hz, 200 mV/mm, 100 ms pulse duration) compared to plain gold electrodes. There was a dominant capacitive component. In proof-of-concept experiments, mESCs were able to respond to such electrostimulation by membrane depolarization and elevation of cytosolic calcium. Further, the PEDOT:PSS platform was able to upregulate cardiomyogenesis and potentially inhibit early neurogenesis per se with minor contribution of electrostimulation. Hence, the present work highlights the large potential of PEDOT:PSS in regenerative medicine.
- 1 May 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 260, 418-425
Evaluation and improvement of organic semiconductors’ biocompatibility towards fibroblasts and cardiomyocytes
- 1 May 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 260, 418-425
Evaluation and improvement of organic semiconductors’ biocompatibility towards fibroblasts and cardiomyocytes
- 23 December 2017
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 106 (4) , 1121-1128
Printing inks of electroactive polymer PEDOT:PSS: The study of biocompatibility, stability, and electrical properties
Biocompatibility tests and a study of the electrical properties of thin films prepared from six electroactive polymer ink formulations based on poly(3,4‐ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) were performed. The aim was to find a suitable formulation of PEDOT:PSS and conditions for preparing thin films in order to construct printed bioelectronic devices for biomedical applications. The stability and electrical properties of such films were tested on organic electrochemical transistor (OECT)‐based sensor platforms and their biocompatibility was evaluated in assays with 3T3 fibroblasts and murine cardiomyocytes. It was found that the thin films prepared from inks without an additive or any thin film post‐treatment provide limited conductivity and stability for use in biomedical applications. These properties were greatly improved by using ethylene glycol and thermal annealing. Addition or post‐treatment by ethylene glycol in combination with thermal annealing provided thin films with electrical resistance and a stability sufficient to be used in sensing of animal cell physiology. These films coated with collagen IV showed good biocompatibility in the assay with 3T3 fibroblasts when compared to standard cell culture plastics. Selected films were then used in assays with murine cardiomyocytes. We observed that these cells were able to attach to the PEDOT:PSS films and form an active sensor element. Spontaneously beating clusters were formed, indicating a good physiological status for the cardiomyocyte cells. These results open the door to construction of cheap printed electronic devices for biointerfacing in biomedical applications. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 1121–1128, 2018.
- 23 December 2017
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 106 (4) , 1121-1128
Printing inks of electroactive polymer PEDOT:PSS: The study of biocompatibility, stability, and electrical properties
Biocompatibility tests and a study of the electrical properties of thin films prepared from six electroactive polymer ink formulations based on poly(3,4‐ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) were performed. The aim was to find a suitable formulation of PEDOT:PSS and conditions for preparing thin films in order to construct printed bioelectronic devices for biomedical applications. The stability and electrical properties of such films were tested on organic electrochemical transistor (OECT)‐based sensor platforms and their biocompatibility was evaluated in assays with 3T3 fibroblasts and murine cardiomyocytes. It was found that the thin films prepared from inks without an additive or any thin film post‐treatment provide limited conductivity and stability for use in biomedical applications. These properties were greatly improved by using ethylene glycol and thermal annealing. Addition or post‐treatment by ethylene glycol in combination with thermal annealing provided thin films with electrical resistance and a stability sufficient to be used in sensing of animal cell physiology. These films coated with collagen IV showed good biocompatibility in the assay with 3T3 fibroblasts when compared to standard cell culture plastics. Selected films were then used in assays with murine cardiomyocytes. We observed that these cells were able to attach to the PEDOT:PSS films and form an active sensor element. Spontaneously beating clusters were formed, indicating a good physiological status for the cardiomyocyte cells. These results open the door to construction of cheap printed electronic devices for biointerfacing in biomedical applications. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 1121–1128, 2018.
- Open Access
- 27 September 2017
- Published by MDPI AG in Applied Sciences
- Vol. 7 (10) , 998
Organic Electrochemical Transistor Microplate for Real-Time Cell Culture Monitoring
Human cell cultures provide a potentially powerful means for pharmacological and toxicological research. A microplate with a multielectrode array of 96 organic electrochemical transistors (OECTs) based on the semiconductive polymer poly(3,4-ethylenedioxythio-phene):poly(styrene sulfonic acid) PEDOT:PSS was developed and fabricated by the screen printing method. It consists of a microplate of a 12 × 8 chimney–well array with transistors on the bottom. The OECT is circular with a channel of 1.5 mm2 in the centre surrounded by the circular gate electrode. The device is designed for electrogenic cell monitoring. Simulations with the electrolyte revealed good electrical characteristics and indicated the setup information of the experimental conditions. A transconductance of g = 1.4 mS was achieved in the wide range of gate voltages Vgs = ±0.4 V when the drain potential Vds = −0.735 V was set and the long term relaxation was compensated for. The time constant 0.15 s limited by the channel-electrolyte charge electrical double layer (EDL) capacitance was measured. The device was tested on a 3T3 fibroblast cell culture and the sudden environmental changes were recorded. The living cells can be observed on the channel of the OECT and during electrical stimulation by gate voltage, as well as during the source current response.
- 27 September 2017
- Published by MDPI AG in Applied Sciences
- Vol. 7 (10) , 998
Open AccessOrganic Electrochemical Transistor Microplate for Real-Time Cell Culture Monitoring
Human cell cultures provide a potentially powerful means for pharmacological and toxicological research. A microplate with a multielectrode array of 96 organic electrochemical transistors (OECTs) based on the semiconductive polymer poly(3,4-ethylenedioxythio-phene):poly(styrene sulfonic acid) PEDOT:PSS was developed and fabricated by the screen printing method. It consists of a microplate of a 12 × 8 chimney–well array with transistors on the bottom. The OECT is circular with a channel of 1.5 mm2 in the centre surrounded by the circular gate electrode. The device is designed for electrogenic cell monitoring. Simulations with the electrolyte revealed good electrical characteristics and indicated the setup information of the experimental conditions. A transconductance of g = 1.4 mS was achieved in the wide range of gate voltages Vgs = ±0.4 V when the drain potential Vds = −0.735 V was set and the long term relaxation was compensated for. The time constant 0.15 s limited by the channel-electrolyte charge electrical double layer (EDL) capacitance was measured. The device was tested on a 3T3 fibroblast cell culture and the sudden environmental changes were recorded. The living cells can be observed on the channel of the OECT and during electrical stimulation by gate voltage, as well as during the source current response.