Christian Weber
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Christian Weber has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Katrin Schmitt
Department of Microsystems Engineering—IMTEK, University of Freiburg, 79110 Freiburg, Germany
4 shared publications - Jürgen Wöllenstein
Laboratory for Gas Sensors, Department of Microsystems Engineering-IMTEK, University of Freiburg, Georges-Köhler-Allee 102, 79110 Freiburg, Germany
3 shared publications - Hassan Yassine
Department of Microsystems Engineering-IMTEK Laboratory for Gas Sensors University of Frei- burg Georges-Köhler-Allee 102 79110 Freiburg Germany
2 shared publications - Andre Eberhardt
Fraunhofer Institute for Physical Measurement Techniques IPM, 79110 Freiburg, Germany
1 shared publication - Hans-Fridtjof Pernau
Fraunhofer Institute for Physical Measurement Techniques IPM, 79110 Freiburg, Germany
1 shared publication - Hendrik Bremer
Fraunhofer Institute for Physical Measurement Techniques IPM, 79110 Freiburg, Germany
1 shared publication
Latest Publications
- Open Access
- 20 April 2026
- Published by The Electrochemical Society in ECS Sensors Plus
- Vol. 5 (2)
Miniaturized Fluorescence-Based Optical Sensor for Real-Time Oxygen Monitoring During Respiration
The increasing demand for real-time oxygen monitoring during respiration is driven by applications in both healthcare and sports, where accurate measurements support medical diagnostics and performance optimization. In this paper, we present the development of a compact optical oxygen sensor. The sensor is based on the principle of fluorescence quenching, in which the fluorescence emission intensity decreases in the presence of oxygen. A pyrene fluorophore embedded in an ethyl cellulose matrix serves as the oxygen-sensitive dye. This work introduces a novel sensing unit designed for seamless integration into a standard T-piece in the field of respiratory medicine. The sensor parts (LED, photodetector and sample holder) were fabricated from aluminum with a base area of 15 mm diameter. The pyrene-ethyl cellulose sensing layer was deposited directly on a cylinder also made of aluminum. This enables easy integration due to the same materials and eliminates the need for a separate glass plate as carrier. The achieved detection resolution is 0.31 vol. % of oxygen during laboratory tests, providing a basis for future research to improve reliability, enhance performance, and explore practical applications in respiratory monitoring.
- 20 April 2026
- Published by The Electrochemical Society in ECS Sensors Plus
- Vol. 5 (2)
Open AccessMiniaturized Fluorescence-Based Optical Sensor for Real-Time Oxygen Monitoring During Respiration
The increasing demand for real-time oxygen monitoring during respiration is driven by applications in both healthcare and sports, where accurate measurements support medical diagnostics and performance optimization. In this paper, we present the development of a compact optical oxygen sensor. The sensor is based on the principle of fluorescence quenching, in which the fluorescence emission intensity decreases in the presence of oxygen. A pyrene fluorophore embedded in an ethyl cellulose matrix serves as the oxygen-sensitive dye. This work introduces a novel sensing unit designed for seamless integration into a standard T-piece in the field of respiratory medicine. The sensor parts (LED, photodetector and sample holder) were fabricated from aluminum with a base area of 15 mm diameter. The pyrene-ethyl cellulose sensing layer was deposited directly on a cylinder also made of aluminum. This enables easy integration due to the same materials and eliminates the need for a separate glass plate as carrier. The achieved detection resolution is 0.31 vol. % of oxygen during laboratory tests, providing a basis for future research to improve reliability, enhance performance, and explore practical applications in respiratory monitoring.
- Open Access
Detection of SO2F2 Using a Photoacoustic Two-Chamber Approach
The wide use of sulfuryl difluoride (SO2F2) for termite control in buildings, warehouses and shipping containers requires the implementation of suitable sensors for reliable detection. SO2F2 is highly toxic to humans and the environment, and moreover, it is a potent greenhouse gas. We developed two photoacoustic two-chamber sensors with the aim to detect two different concentration ranges, 0–1 vol.-% SO2F2 and 0–100 ppm SO2F2, so that different applications can be targeted: the sensor for high concentrations for the effective treatment of buildings, containers, etc., and the sensor for low concentrations as personal safety device. Photoacoustic detectors were designed, fabricated, and then filled with either pure SO2F2 or pure substituent gas, the refrigerant R227ea, to detect SO2F2. Absorption cells with optical path lengths of 50 mm and 1.6 m were built for both concentration ranges. The sensitivity to SO2F2 as well as cross-sensitivities to CO2 and H2O were measured. The results show that concentrations below 1 ppm SO2F2 can be reliably detected, and possible cross-sensitivities can be effectively compensated.
Open AccessDetection of SO2F2 Using a Photoacoustic Two-Chamber Approach
The wide use of sulfuryl difluoride (SO2F2) for termite control in buildings, warehouses and shipping containers requires the implementation of suitable sensors for reliable detection. SO2F2 is highly toxic to humans and the environment, and moreover, it is a potent greenhouse gas. We developed two photoacoustic two-chamber sensors with the aim to detect two different concentration ranges, 0–1 vol.-% SO2F2 and 0–100 ppm SO2F2, so that different applications can be targeted: the sensor for high concentrations for the effective treatment of buildings, containers, etc., and the sensor for low concentrations as personal safety device. Photoacoustic detectors were designed, fabricated, and then filled with either pure SO2F2 or pure substituent gas, the refrigerant R227ea, to detect SO2F2. Absorption cells with optical path lengths of 50 mm and 1.6 m were built for both concentration ranges. The sensitivity to SO2F2 as well as cross-sensitivities to CO2 and H2O were measured. The results show that concentrations below 1 ppm SO2F2 can be reliably detected, and possible cross-sensitivities can be effectively compensated.
- Open Access
Towards a Miniaturized Photoacoustic Detector for the Infrared Spectroscopic Analysis of SO2F2 and Refrigerants
Sulfuryl fluoride (SO2F2) is a toxic and potent greenhouse gas that is currently widely used as a fumigant insecticide in houses, food, and shipping containers. Though it poses a major hazard to humans, its detection is still carried out manually and only on a random basis. In this paper, we present a two-chamber photoacoustic approach for continuous SO2F2 sensing. Because of the high toxicity of SO2F2, the concept is to use a non-toxic substituent gas with similar absorption characteristics in the photoacoustic detector chamber, i.e., to measure SO2F2 indirectly. The refrigerants R227ea, R125, R134a, and propene were identified as possible substituents using a Fourier-transform infrared (FTIR) spectroscopic analysis. The resulting infrared spectra were used to simulate the sensitivity of the substituents of a photoacoustic sensor to SO2F2 in different concentration ranges and at different optical path lengths. The simulations showed that R227ea has the highest sensitivity to SO2F2 among the substituents and is therefore a promising substituent detector gas. Simulations concerning the possible cross-sensitivity of the photoacoustic detectors to H2O and CO2 were also performed. These results are the first step towards the development of a miniaturized, sensitive, and cost-effective photoacoustic sensor system for SO2F2.
Open AccessTowards a Miniaturized Photoacoustic Detector for the Infrared Spectroscopic Analysis of SO2F2 and Refrigerants
Sulfuryl fluoride (SO2F2) is a toxic and potent greenhouse gas that is currently widely used as a fumigant insecticide in houses, food, and shipping containers. Though it poses a major hazard to humans, its detection is still carried out manually and only on a random basis. In this paper, we present a two-chamber photoacoustic approach for continuous SO2F2 sensing. Because of the high toxicity of SO2F2, the concept is to use a non-toxic substituent gas with similar absorption characteristics in the photoacoustic detector chamber, i.e., to measure SO2F2 indirectly. The refrigerants R227ea, R125, R134a, and propene were identified as possible substituents using a Fourier-transform infrared (FTIR) spectroscopic analysis. The resulting infrared spectra were used to simulate the sensitivity of the substituents of a photoacoustic sensor to SO2F2 in different concentration ranges and at different optical path lengths. The simulations showed that R227ea has the highest sensitivity to SO2F2 among the substituents and is therefore a promising substituent detector gas. Simulations concerning the possible cross-sensitivity of the photoacoustic detectors to H2O and CO2 were also performed. These results are the first step towards the development of a miniaturized, sensitive, and cost-effective photoacoustic sensor system for SO2F2.
- Open Access
Resonant Photoacoustic Spectroscopy of NO2 with a UV-LED Based Sensor
Nitrogen dioxide (NO2) is a poisonous trace gas that requires monitoring in urban areas. Accurate measurement in sub-ppm concentrations represents a wide application field for suitable economical sensors. We present a novel approach to measure NO2 with a photoacoustic sensor using a T-shaped resonance cell. An inexpensive UV-LED with a peak wavelength of 405 nm as radiation source as well as a commercial MEMS microphone for acoustic detection were used. In this work, a cell has been developed that enables a “non-contact” feedthrough of the divergent LED beam. Thus, unwanted background noise due to absorption on the inside walls is minimized. As part of the development, an acoustic simulation has been carried out to find the resonance frequencies and to visualize the resulting standing wave patterns in various geometries. The pressure amplitude was calculated for different shapes and sizes. A model iteratively optimized in this way forms the basis of a construction that was built for gas measurement by rapid prototyping methods. The real resonance frequencies were compared to the ones found in simulation. The limit of detection was determined in a nitrogen dioxide measurement to be 200 ppb (6 σ) for a cell made of aluminum.Open AccessResonant Photoacoustic Spectroscopy of NO2 with a UV-LED Based Sensor
Nitrogen dioxide (NO2) is a poisonous trace gas that requires monitoring in urban areas. Accurate measurement in sub-ppm concentrations represents a wide application field for suitable economical sensors. We present a novel approach to measure NO2 with a photoacoustic sensor using a T-shaped resonance cell. An inexpensive UV-LED with a peak wavelength of 405 nm as radiation source as well as a commercial MEMS microphone for acoustic detection were used. In this work, a cell has been developed that enables a “non-contact” feedthrough of the divergent LED beam. Thus, unwanted background noise due to absorption on the inside walls is minimized. As part of the development, an acoustic simulation has been carried out to find the resonance frequencies and to visualize the resulting standing wave patterns in various geometries. The pressure amplitude was calculated for different shapes and sizes. A model iteratively optimized in this way forms the basis of a construction that was built for gas measurement by rapid prototyping methods. The real resonance frequencies were compared to the ones found in simulation. The limit of detection was determined in a nitrogen dioxide measurement to be 200 ppb (6 σ) for a cell made of aluminum.