Gaia Amaranta Taberna
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gaia Amaranta Taberna has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Dante Mantini
Movement Control and Neuroplasticity Research Group, KU Leuven, Leuven, 3001, Belgium
9 shared publications Marco Ganzetti
Movement Control and Neuroplasticity Research Group, KU Leuven, 3001, Leuven, Belgium; Roche Pharma Research and Early Development (pRED), pRED Data & Analytics, Roche Innovation Center Basel, F. Hoffmann-La Roche Ltd, 4070, Basel, Switzerland
5 shared publicationsDante Mantini
4 shared publications- Jessica Samogin
Neuroscience of Movement and Performance Research Group, Department of Movement Sciences, KU Leuven, 3001 Leuven, Belgium
4 shared publications Mingqi Zhao
Movement Control and Neuroplasticity Research Group, KU Leuven, 3001, Leuven, Belgium; Gansu Provincial Key Laboratory of Wearable Computing, School of Information Science and Engineering, Lanzhou University, 730000, Lanzhou, PR China
4 shared publicationsJessica Samogin
Movement Control and Neuroplasticity Research Group, KU Leuven, 3001, Leuven, Belgium
3 shared publications
Latest Publications
- 3 June 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 178, 108704
Large-scale analysis of neural activity and connectivity from high-density electroencephalographic data
- 3 June 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 178, 108704
Large-scale analysis of neural activity and connectivity from high-density electroencephalographic data
- Open Access
- 6 April 2022
- Published by Wiley in Human Brain Mapping
- Vol. 43 (11) , 3404-3415
Frequency‐dependent modulation of neural oscillations across the gait cycle
Balance and walking are fundamental to support common daily activities. Relatively accurate characterizations of normal and impaired gait features were attained at the kinematic and muscular levels. Conversely, the neural processes underlying gait dynamics still need to be elucidated. To shed light on gait‐related modulations of neural activity, we collected high‐density electroencephalography (hdEEG) signals and ankle acceleration data in young healthy participants during treadmill walking. We used the ankle acceleration data to segment each gait cycle in four phases: initial double support, right leg swing, final double support, left leg swing. Then, we processed hdEEG signals to extract neural oscillations in alpha, beta, and gamma bands, and examined event‐related desynchronization/synchronization (ERD/ERS) across gait phases. Our results showed that ERD/ERS modulations for alpha, beta, and gamma bands were strongest in the primary sensorimotor cortex (M1), but were also found in premotor cortex, thalamus and cerebellum. We observed a modulation of neural oscillations across gait phases in M1 and cerebellum, and an interaction between frequency band and gait phase in premotor cortex and thalamus. Furthermore, an ERD/ERS lateralization effect was present in M1 for the alpha and beta bands, and in the cerebellum for the beta and gamma bands. Overall, our findings demonstrate that an electrophysiological source imaging approach based on hdEEG can be used to investigate dynamic neural processes of gait control. Future work on the development of mobile hdEEG‐based brain–body imaging platforms may enable overground walking investigations, with potential applications in the study of gait disorders.
- 6 April 2022
- Published by Wiley in Human Brain Mapping
- Vol. 43 (11) , 3404-3415
Open AccessFrequency‐dependent modulation of neural oscillations across the gait cycle
Balance and walking are fundamental to support common daily activities. Relatively accurate characterizations of normal and impaired gait features were attained at the kinematic and muscular levels. Conversely, the neural processes underlying gait dynamics still need to be elucidated. To shed light on gait‐related modulations of neural activity, we collected high‐density electroencephalography (hdEEG) signals and ankle acceleration data in young healthy participants during treadmill walking. We used the ankle acceleration data to segment each gait cycle in four phases: initial double support, right leg swing, final double support, left leg swing. Then, we processed hdEEG signals to extract neural oscillations in alpha, beta, and gamma bands, and examined event‐related desynchronization/synchronization (ERD/ERS) across gait phases. Our results showed that ERD/ERS modulations for alpha, beta, and gamma bands were strongest in the primary sensorimotor cortex (M1), but were also found in premotor cortex, thalamus and cerebellum. We observed a modulation of neural oscillations across gait phases in M1 and cerebellum, and an interaction between frequency band and gait phase in premotor cortex and thalamus. Furthermore, an ERD/ERS lateralization effect was present in M1 for the alpha and beta bands, and in the cerebellum for the beta and gamma bands. Overall, our findings demonstrate that an electrophysiological source imaging approach based on hdEEG can be used to investigate dynamic neural processes of gait control. Future work on the development of mobile hdEEG‐based brain–body imaging platforms may enable overground walking investigations, with potential applications in the study of gait disorders.
- Open Access
- 3 June 2021
- Published by MDPI AG in Brain Sciences
- Vol. 11 (6) , 741
Detection of Resting-State Functional Connectivity from High-Density Electroencephalography Data: Impact of Head Modeling Strategies
Recent technological advances have been permitted to use high-density electroencephalography (hdEEG) for the estimation of functional connectivity and the mapping of resting-state networks (RSNs). The reliable estimate of activity and connectivity from hdEEG data relies on the creation of an accurate head model, defining how neural currents propagate from the cortex to the sensors placed over the scalp. To the best of our knowledge, no study has been conducted yet to systematically test to what extent head modeling accuracy impacts on EEG-RSN reconstruction. To address this question, we used 256-channel hdEEG data collected in a group of young healthy participants at rest. We first estimated functional connectivity in EEG-RSNs by means of band-limited power envelope correlations, using neural activity estimated with an optimized analysis workflow. Then, we defined a series of head models with different levels of complexity, specifically testing the effect of different electrode positioning techniques and head tissue segmentation methods. We observed that robust EEG-RSNs can be obtained using a realistic head model, and that inaccuracies due to head tissue segmentation impact on RSN reconstruction more than those due to electrode positioning. Additionally, we found that EEG-RSN robustness to head model variations had space and frequency specificity. Overall, our results may contribute to defining a benchmark for assessing the reliability of hdEEG functional connectivity measures.
- 3 June 2021
- Published by MDPI AG in Brain Sciences
- Vol. 11 (6) , 741
Open AccessDetection of Resting-State Functional Connectivity from High-Density Electroencephalography Data: Impact of Head Modeling Strategies
Recent technological advances have been permitted to use high-density electroencephalography (hdEEG) for the estimation of functional connectivity and the mapping of resting-state networks (RSNs). The reliable estimate of activity and connectivity from hdEEG data relies on the creation of an accurate head model, defining how neural currents propagate from the cortex to the sensors placed over the scalp. To the best of our knowledge, no study has been conducted yet to systematically test to what extent head modeling accuracy impacts on EEG-RSN reconstruction. To address this question, we used 256-channel hdEEG data collected in a group of young healthy participants at rest. We first estimated functional connectivity in EEG-RSNs by means of band-limited power envelope correlations, using neural activity estimated with an optimized analysis workflow. Then, we defined a series of head models with different levels of complexity, specifically testing the effect of different electrode positioning techniques and head tissue segmentation methods. We observed that robust EEG-RSNs can be obtained using a realistic head model, and that inaccuracies due to head tissue segmentation impact on RSN reconstruction more than those due to electrode positioning. Additionally, we found that EEG-RSN robustness to head model variations had space and frequency specificity. Overall, our results may contribute to defining a benchmark for assessing the reliability of hdEEG functional connectivity measures.
- Open Access
- 27 January 2021
- Published by Springer Nature in Neuroinformatics
- Vol. 19 (4) , 585-596
Automated Head Tissue Modelling Based on Structural Magnetic Resonance Images for Electroencephalographic Source Reconstruction
In the last years, technological advancements for the analysis of electroencephalography (EEG) recordings have permitted to investigate neural activity and connectivity in the human brain with unprecedented precision and reliability. A crucial element for accurate EEG source reconstruction is the construction of a realistic head model, incorporating information on electrode positions and head tissue distribution. In this paper, we introduce MR-TIM, a toolbox for head tissue modelling from structural magnetic resonance (MR) images. The toolbox consists of three modules: 1) image pre-processing – the raw MR image is denoised and prepared for further analyses; 2) tissue probability mapping – template tissue probability maps (TPMs) in individual space are generated from the MR image; 3) tissue segmentation – information from all the TPMs is integrated such that each voxel in the MR image is assigned to a specific tissue. MR-TIM generates highly realistic 3D masks, five of which are associated with brain structures (brain and cerebellar grey matter, brain and cerebellar white matter, and brainstem) and the remaining seven with other head tissues (cerebrospinal fluid, spongy and compact bones, eyes, muscle, fat and skin). Our validation, conducted on MR images collected in healthy volunteers and patients as well as an MR template image from an open-source repository, demonstrates that MR-TIM is more accurate than alternative approaches for whole-head tissue segmentation. We hope that MR-TIM, by yielding an increased precision in head modelling, will contribute to a more widespread use of EEG as a brain imaging technique.
- 27 January 2021
- Published by Springer Nature in Neuroinformatics
- Vol. 19 (4) , 585-596
Open AccessAutomated Head Tissue Modelling Based on Structural Magnetic Resonance Images for Electroencephalographic Source Reconstruction
In the last years, technological advancements for the analysis of electroencephalography (EEG) recordings have permitted to investigate neural activity and connectivity in the human brain with unprecedented precision and reliability. A crucial element for accurate EEG source reconstruction is the construction of a realistic head model, incorporating information on electrode positions and head tissue distribution. In this paper, we introduce MR-TIM, a toolbox for head tissue modelling from structural magnetic resonance (MR) images. The toolbox consists of three modules: 1) image pre-processing – the raw MR image is denoised and prepared for further analyses; 2) tissue probability mapping – template tissue probability maps (TPMs) in individual space are generated from the MR image; 3) tissue segmentation – information from all the TPMs is integrated such that each voxel in the MR image is assigned to a specific tissue. MR-TIM generates highly realistic 3D masks, five of which are associated with brain structures (brain and cerebellar grey matter, brain and cerebellar white matter, and brainstem) and the remaining seven with other head tissues (cerebrospinal fluid, spongy and compact bones, eyes, muscle, fat and skin). Our validation, conducted on MR images collected in healthy volunteers and patients as well as an MR template image from an open-source repository, demonstrates that MR-TIM is more accurate than alternative approaches for whole-head tissue segmentation. We hope that MR-TIM, by yielding an increased precision in head modelling, will contribute to a more widespread use of EEG as a brain imaging technique.
- Open Access
- 28 July 2020
- Published by Springer Nature in Neuroinformatics
- Vol. 19 (2) , 251-266
RT-NET: real-time reconstruction of neural activity using high-density electroencephalography
High-density electroencephalography (hdEEG) has been successfully used for large-scale investigations of neural activity in the healthy and diseased human brain. Because of their high computational demand, analyses of source-projected hdEEG data are typically performed offline. Here, we present a real-time noninvasive electrophysiology toolbox, RT-NET, which has been specifically developed for online reconstruction of neural activity using hdEEG. RT-NET relies on the Lab Streaming Layer for acquiring raw data from a large number of EEG amplifiers and for streaming the processed data to external applications. RT-NET estimates a spatial filter for artifact removal and source activity reconstruction using a calibration dataset. This spatial filter is then applied to the hdEEG data as they are acquired, thereby ensuring low latencies and computation times. Overall, our analyses show that RT-NET can estimate real-time neural activity with performance comparable to offline analysis methods. It may therefore enable the development of novel brain–computer interface applications such as source-based neurofeedback.
- 28 July 2020
- Published by Springer Nature in Neuroinformatics
- Vol. 19 (2) , 251-266
Open AccessRT-NET: real-time reconstruction of neural activity using high-density electroencephalography
High-density electroencephalography (hdEEG) has been successfully used for large-scale investigations of neural activity in the healthy and diseased human brain. Because of their high computational demand, analyses of source-projected hdEEG data are typically performed offline. Here, we present a real-time noninvasive electrophysiology toolbox, RT-NET, which has been specifically developed for online reconstruction of neural activity using hdEEG. RT-NET relies on the Lab Streaming Layer for acquiring raw data from a large number of EEG amplifiers and for streaming the processed data to external applications. RT-NET estimates a spatial filter for artifact removal and source activity reconstruction using a calibration dataset. This spatial filter is then applied to the hdEEG data as they are acquired, thereby ensuring low latencies and computation times. Overall, our analyses show that RT-NET can estimate real-time neural activity with performance comparable to offline analysis methods. It may therefore enable the development of novel brain–computer interface applications such as source-based neurofeedback.
- Open Access
- 6 September 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
SPOT3D: Spatial positioning toolbox for head markers using 3D scans
Recent studies have highlighted the importance of an accurate individual head model for reliably using high-density electroencephalography (hdEEG) as a brain imaging technique. Correct identification of sensor positions is fundamental for accurately estimating neural activity from hdEEG recordings. We previously introduced a method of automated localization and labelling of hdEEG sensors using an infrared colour-enhanced 3D scanner. Here, we describe an extension of this method, the spatial positioning toolbox for head markers using 3D scans (SPOT3D), which integrates a graphical user interface (GUI). This enables the correction of imprecisions in EEG sensor positioning and the inclusion of additional head markers. The toolbox was validated using 3D scan data collected in four participants wearing a 256-channel hdEEG cap. We quantified the misalignment between the 3D scan and the head shape, and errors in EEG sensor locations. We assessed these parameters after using the automated approach and after manually adjusting its results by means of the GUI. The GUI overcomes the main limitations of the automated method, yielding enhanced precision and reliability of head marker positioning.
- 6 September 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Open AccessSPOT3D: Spatial positioning toolbox for head markers using 3D scans
Recent studies have highlighted the importance of an accurate individual head model for reliably using high-density electroencephalography (hdEEG) as a brain imaging technique. Correct identification of sensor positions is fundamental for accurately estimating neural activity from hdEEG recordings. We previously introduced a method of automated localization and labelling of hdEEG sensors using an infrared colour-enhanced 3D scanner. Here, we describe an extension of this method, the spatial positioning toolbox for head markers using 3D scans (SPOT3D), which integrates a graphical user interface (GUI). This enables the correction of imprecisions in EEG sensor positioning and the inclusion of additional head markers. The toolbox was validated using 3D scan data collected in four participants wearing a 256-channel hdEEG cap. We quantified the misalignment between the 3D scan and the head shape, and errors in EEG sensor locations. We assessed these parameters after using the automated approach and after manually adjusting its results by means of the GUI. The GUI overcomes the main limitations of the automated method, yielding enhanced precision and reliability of head marker positioning.