Bader Almutairi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bader Almutairi has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Shoaib Usman
Department of Mining and Nuclear Engineering, Missouri University of Science and Technology, Rolla, MO 65401, USA
3 shared publications Cameron S. Goodwin
Rhode Island Atomic Energy Commission, Narragansett, RI, USA
2 shared publications- Syed Bahauddin Alam
National Center for Supercomputing Applications Plasma & Radiological Engineering University of Illinois at Urbana-Champaign 61801 Urbana IL USA
2 shared publications - Abdullah AlFoudari
Energy and Building Research Centre, Kuwait Institute for Scientific Research, P.O. Box 24885, Kuwait City 13109, Kuwait
1 shared publication - Areej AlBanwan
Energy and Building Research Center, Sustainability and Reliability of Infrastructure Program, Kuwait Institute for Scientific Research, P.O. Box 24885 Safat, Kuwait City 13109, Kuwait
1 shared publication - Ayodeji Alajo
Missouri University of Science and Technology
1 shared publication
Latest Publications
- Open Access
Stakeholder Risk Perception of Small Modular Reactor-Based Cogeneration Infrastructure Systems for Electricity and Desalination
Kuwait’s electricity and desalinated water systems are tightly coupled through hydrocarbon-fired cogeneration, while peak demand continues to rise under extreme summer conditions. Small modular reactor (SMR) cogeneration has therefore been discussed as a possible long-term option, although it is not part of the current national energy plan. This study identifies and ranks the risks associated with the construction and development of SMR cogeneration infrastructure in Kuwait from the perspective of construction, energy and institutional stakeholders. A risk catalog was developed from the literature, Kuwait-specific nuclear and energy evidence, interviews and a focus group, and was then rated through a questionnaire completed by 267 professionals. The probability and impact of 55 risk factors were assessed using five-point Likert scales and ranked using the relative index (RII). The reliability of the probability and impact scales was high, with Cronbach’s alpha values of 0.971 and 0.964, respectively. The highest ranked risks were the absence of a national nuclear energy law, the lack of a national nuclear strategy, the absence of an independent regulator, inadequate emergency preparedness and shortage of national nuclear expertise. The findings indicate that institutional and regulatory readiness, rather than technical or financial capability, forms the main constraint on any future SMR cogeneration program in Kuwait.
Open AccessStakeholder Risk Perception of Small Modular Reactor-Based Cogeneration Infrastructure Systems for Electricity and Desalination
Kuwait’s electricity and desalinated water systems are tightly coupled through hydrocarbon-fired cogeneration, while peak demand continues to rise under extreme summer conditions. Small modular reactor (SMR) cogeneration has therefore been discussed as a possible long-term option, although it is not part of the current national energy plan. This study identifies and ranks the risks associated with the construction and development of SMR cogeneration infrastructure in Kuwait from the perspective of construction, energy and institutional stakeholders. A risk catalog was developed from the literature, Kuwait-specific nuclear and energy evidence, interviews and a focus group, and was then rated through a questionnaire completed by 267 professionals. The probability and impact of 55 risk factors were assessed using five-point Likert scales and ranked using the relative index (RII). The reliability of the probability and impact scales was high, with Cronbach’s alpha values of 0.971 and 0.964, respectively. The highest ranked risks were the absence of a national nuclear energy law, the lack of a national nuclear strategy, the absence of an independent regulator, inadequate emergency preparedness and shortage of national nuclear expertise. The findings indicate that institutional and regulatory readiness, rather than technical or financial capability, forms the main constraint on any future SMR cogeneration program in Kuwait.
- Open Access
- 9 January 2023
- Published by MDPI AG in Preprints.org
Explainable, Interpretable & Trustworthy AI for Intelligent Digital Twin: Case Study on Remaining Useful Life
Machine learning (ML) and Artificial Intelligence (AI) are increasingly used in energy and engineering systems, but these models must be fair, unbiased, and explainable. In other words, it is crucial to have confidence in AI's trustworthiness. Machine learning techniques, like neural networks, have helped predict important parameters and improve model performance. But for these AI techniques to be useful for making decisions, they need to be audited, accounted for, and easy to understand. The use of Explainable AI (XAI) and interpretable machine learning (IML) is crucial for the accurate prediction of prognostics, such as remaining useful life (RUL) in a digital twin system to make it intelligent while ensuring that the AI model is transparent in its decision-making processes and that the predictions it generates can be understood and trusted by users. By using AI that is explainable, interpretable, and trustworthy, intelligent digital twin systems can make more accurate predictions of RUL, leading to better maintenance and repair planning and, ultimately, improved system performance. The objective of this paper is to understand the idea of XAI and interpretable ML (IML) and justify the important role of ML/AI in the Digital Twin framework and components, which requires XAI to understand the prediction better. This paper explains the importance of XAI and IML in both local and global aspects to ensure the use of trustworthy ML/AI applications for RUL prediction. This paper used the RUL prediction for the XAI and IML studies and leveraged the integrated python toolbox for interpretable machine learning (PiML)
- 9 January 2023
- Published by MDPI AG in Preprints.org
Open AccessExplainable, Interpretable & Trustworthy AI for Intelligent Digital Twin: Case Study on Remaining Useful Life
Machine learning (ML) and Artificial Intelligence (AI) are increasingly used in energy and engineering systems, but these models must be fair, unbiased, and explainable. In other words, it is crucial to have confidence in AI's trustworthiness. Machine learning techniques, like neural networks, have helped predict important parameters and improve model performance. But for these AI techniques to be useful for making decisions, they need to be audited, accounted for, and easy to understand. The use of Explainable AI (XAI) and interpretable machine learning (IML) is crucial for the accurate prediction of prognostics, such as remaining useful life (RUL) in a digital twin system to make it intelligent while ensuring that the AI model is transparent in its decision-making processes and that the predictions it generates can be understood and trusted by users. By using AI that is explainable, interpretable, and trustworthy, intelligent digital twin systems can make more accurate predictions of RUL, leading to better maintenance and repair planning and, ultimately, improved system performance. The objective of this paper is to understand the idea of XAI and interpretable ML (IML) and justify the important role of ML/AI in the Digital Twin framework and components, which requires XAI to understand the prediction better. This paper explains the importance of XAI and IML in both local and global aspects to ensure the use of trustworthy ML/AI applications for RUL prediction. This paper used the RUL prediction for the XAI and IML studies and leveraged the integrated python toolbox for interpretable machine learning (PiML)
- Open Access
- 17 November 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-15
Experimental evaluation of the deadtime phenomenon for GM detector: deadtime dependence on operating voltages
A detailed analysis of Geiger Mueller counter deadtime dependence on operating voltage is presented in the manuscript using four pairs of radiation sources. Based on two-source method, detector deadtime is calculated for a wide range of operating voltages which revealed a peculiar relationship between the operating voltage and the detector deadtime. In the low voltage range, a distinct drop in deadtime was observed where deadtime reached a value as low as a few microseconds (22 µs for 204Tl, 26 µs for 137Cs, 9 µs for 22Na). This sharp drop in the deadtime is possibly due to reduced recombination with increasing voltage. After the lowest point, the deadtime generally increased rapidly to reach a maximum (292 µs for 204Tl, 277 µs for 137Cs, 258 µs for 22Na). This rapid increase in the deadtime is mainly due to the on-set of charge multiplication. After the maximum deadtime values, there was an exponential decrease in the deadtime reaching an asymptotic low where the manufacturer recommended voltage for operation falls. This pattern of deadtime voltage dependence was repeated for all sources tested with the exception of 54Mn. Low count rates leading to a negative deadtime suggested poor statistical nature of the data collected for 54Mn and the data while being presented here is not used for any inference.
- 17 November 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-15
Open AccessExperimental evaluation of the deadtime phenomenon for GM detector: deadtime dependence on operating voltages
A detailed analysis of Geiger Mueller counter deadtime dependence on operating voltage is presented in the manuscript using four pairs of radiation sources. Based on two-source method, detector deadtime is calculated for a wide range of operating voltages which revealed a peculiar relationship between the operating voltage and the detector deadtime. In the low voltage range, a distinct drop in deadtime was observed where deadtime reached a value as low as a few microseconds (22 µs for 204Tl, 26 µs for 137Cs, 9 µs for 22Na). This sharp drop in the deadtime is possibly due to reduced recombination with increasing voltage. After the lowest point, the deadtime generally increased rapidly to reach a maximum (292 µs for 204Tl, 277 µs for 137Cs, 258 µs for 22Na). This rapid increase in the deadtime is mainly due to the on-set of charge multiplication. After the maximum deadtime values, there was an exponential decrease in the deadtime reaching an asymptotic low where the manufacturer recommended voltage for operation falls. This pattern of deadtime voltage dependence was repeated for all sources tested with the exception of 54Mn. Low count rates leading to a negative deadtime suggested poor statistical nature of the data collected for 54Mn and the data while being presented here is not used for any inference.
- Open Access
- 1 July 2019
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 51 (4) , 1081-1090
Voltage dependent pulse shape analysis of Geiger-Müller counter
- 1 July 2019
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 51 (4) , 1081-1090
Open AccessVoltage dependent pulse shape analysis of Geiger-Müller counter