JSJosé Augusto Sedrez-Porto

José Augusto Sedrez-Porto

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


José Augusto Sedrez-Porto has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    New material perspective for endocrown restorations: effects on mechanical performance and fracture behavior

    by José Augusto Sedrez-Porto, Eliseu Aldrighi Münchow, Lisia Lorea Valente, Maximiliano Sergio Cenci, Tatiana Pereira-Cenci

    The aim of this study was to investigate the mechanical performance and the fracture behavior of endocrown restorations prepared using distinct restorative materials. A total of 42 sound molars with similar crown size and shape were cut at 2 mm above the cementoenamel junction and endodontically treated. They were categorized according to the restorative material used to fabricate endocrown restorations (n=7), namely, conventional composite (Filtek™ Z350 XT), bulk fill composite (Filtek™ Bulk Fill), conventional composite modeled using resin adhesives (SBMP: Scotchbond™ Multipurpose Adhesive; or SBU: Scotchbond™ Universal Adhesive), and IPS e.max lithium disilicate (Ivoclar Vivadent; positive control). Unprepared sound teeth were used as negative control. All endocrowns were bonded using a self-adhesive cement (Rely-X™ U200). The teeth were submitted to fatigue (Byocycle) and fracture (EMIC DL500) testing. Load-to-fracture (in N) and work-of-fracture (Wf, in J/m2) values were analyzed by ANOVA (p < 0.05). The endocrowns did not fracture or de-bond upon fatigue, showing similar load-to-fracture and work-of-fracture values, regardless of the restorative material (p > 0.05). The endocrowns fabricated by combining Z350 and SBMP had the least harsh fractures, in contrast to endocrowns prepared using Z350 only, which exhibited an equilibrium between repairable and irrepairable fractures. The e.max endocrowns exhibited more aggressive failures (root fracture) than other groups, resulting in higher rates of irrepairable fractures. In conclusion, dental practitioners may satisfactorily restore severely damaged nonvital teeth using the endocrown technique. Composite endocrowns prepared using resin adhesive as modeler liquid or using bulk fill material may result in less aggressive failures, thus providing a new material perspective for endocrown restorations.


  • Open Access

    Translucency and color stability of resin composite and dental adhesives as modeling liquids – A one-year evaluation

    by José Augusto Sedrez-Porto, Eliseu Aldrighi Münchow, Maximiliano Sérgio Cenci, Tatiana Pereira-Cenci

    The aim of this study is to evaluate the influence of modeling liquids on the translucency and color shade of resin composites (RCs) after one year of storage. RC specimens were prepared using either a conventional insertion technique (control; without modeling liquid) or a restorative dental modeling insertion technique (RDMIT) with dental adhesives as modeling liquids (Scotchbond™ Multi-Purpose [SBMP; 3M ESPE] or Adper™ Single Bond 2 [SB; 3M ESPE]). The initial colors of the specimens were obtained with a digital spectrophotometer and the CIEL*a*b* color system, after which specimens were stored (37°C) in distilled water or red wine for 12 months. Color measurements were reassessed after 6 and 12 months of storage, and scanning electron microscopy was performed after 12 months. Translucency and color change (ΔE*) were calculated and analyzed using ANOVA and Tukey’s test (α = 5%). RC samples prepared via RDMIT showed a translucency similar to that of control samples. ΔE* was also less intense for RCs containing SBMP than for RCs containing SB. Specimens stored in wine showed a clear pattern of degradation, especially in the control group, and surface degradation seemed to be less intense for specimens prepared with SBMP and SB than for specimens without. Specimens stored in water did not show clear evidence of surface degradation. RDMIT appears to be an interesting approach to reduce ΔE* in RCs over time without negative effects on the translucency of the material. However, the modeling liquid should feature a hydrophobic composition, similar to that used in the SBMP group, the achieve the best results.


  • Top Cited Papers

    Endocrown restorations: A systematic review and meta-analysis

    by José Augusto Sedrez-Porto, Wellington Luiz de Oliveira da Rosa, Adriana Fernandes da Silva, Eliseu Aldrighi Münchow, Tatiana Pereira-Cenci


  • Use of dental adhesives as modeler liquid of resin composites

    by Eliseu Aldrighi Münchow, José Augusto Sedrez-Porto, Evandro Piva, Tatiana Pereira-Cenci, Maximiliano Sergio Cenci


  • Open Access

    Effects of modeling liquid/resin and polishing on the color change of resin composite

    by José Augusto Sedrez-Porto, Eliseu Aldrighi Münchow, Lucas Pradebon Brondani, Maximiliano Sergio Cenci, Tatiana Pereira-Cenci

    Modeling liquids/resins have been used to build up resin composite (RC) restorations, although there is a lack of information regarding their effects on the color stability of the latter. Therefore, the purpose of the present study was to evaluate the effects of the presence of modeling liquid between layers of RC and the finishing/polishing state of the material on color change in specimens exposed to red wine staining over time. Specimens were prepared by placing four increments (±0.5 mm thick) of RC (Filtek™ Z350 XT, 3M ESPE) into molds; half of which were prepared by applying modeling liquid (Scotchbond™ Multi-Purpose™ Adhesive, SBMP, 3M ESPE) between the layers of RC, whereas the other half were prepared without SBMP (control). Light-activation was performed after application of the final RC layer using a light-emitting diode (Radii, SDI) curing unit with an irradiance of 900 mW/cm2 for 20 s. Each group was divided according to the surface finishing protocol (n = 7): nothing (non-polished) or polishing with Sof-Lex™/diamond paste (polished). Initial colors of the specimens were evaluated with a digital spectrophotometer and the CIEL*a*b* color system. The specimens were stored in wine (37°C) for 12 months, and the color measurements were reassessed after 4, 6, and 12 months of storage. Scanning electron microscopy (SEM) analysis was performed at the end. Data were analyzed using ANOVA and Tukey’s test (α = 5%). The presence of SBMP resulted in lower overall color change of the RC as compared with the control. The non-polished specimens exhibited a significantly higher color change than the polished specimens. SEM images corroborated the previous findings. In summary, the use of modeling liquid between layers of RC shows potential for application to reduce or delay the staining process of RC over time. Moreover, polishing is essential to provide increased color stability of the RC restoration.


  • Open Access

    Impairment of resin cement application on the bond strength of indirect composite restorations

    by Jovito Adiel Skupien, José Augusto Sedrez Porto, Eliseu Aldrighi Münchow, Maximiliano Sérgio Cenci, Tatiana Pereira-Cenci

    The aims of this study were to evaluate the effect of immediate and delayed resin cement application on the microtensile bond strength of indirect composite resin restorations and, to evaluate adhesive strategies (for regular resin cement or humidity parameters for self-adhesive resin cement). Forty-five enamel/dentin discs (0.5 mm height and 10 mm of diameter) obtained from bovine teeth were divided into nine groups (n = 5). For regular cement, the variation factors were cementation technique at three levels (immediate cementation, 5 or 30 min after adhesive system application); and type of adhesive system at two levels (three- or two-step). For self-adhesive cement, the dentin moisture was the source of variation at three levels (normal, dry, or wet cementation). The specimens were submitted to microtensile bond strength (μTBS) testing using a universal testing machine. Data were analyzed by ANOVA, Tukey’s test, and linear regression. Regular cement and three-step etch-and-rinse adhesive system showed the highest values of bond strength (25.21 MPa–30 min of delay). Only for this condition, three-step adhesive showed higher bond strength than the two-step adhesive. Nevertheless, the linear regression showed that irrespective of the strategy, the use of the two-step approach when compared with three-step adhesive system decreased μTBS (p < 0.001). The failure analysis showed predominant adhesive failures for all tested groups. All groups had comparable values of bond strength to bovine dentin when the same materials were used, even in suboptimal clinical conditions.


  • Invited Commentary: Should Occlusal Splints Be a Routine Prescription for Diagnosed Bruxers Undergoing Implant Therapy?

    by Mauro Mesko, Rita Almeida, José Porto, Clarissa Koller, Wellington Rosa, Noéli Boscato

    Despite the documented excellent clinical performance of dental implants, concerns linger regarding the best way to protect the restored dentition in patients with bruxism. This is because of the risk of occlusal overload that is reported to cause biological and biomechanical failures in the implant-prosthesis system. To better distribute occlusal loads to the rigid components of the prosthesis and to the interface between bone and implant during parafunctional movements, several dentists prescribe acrylic resin occlusal splints for nocturnal use by patients considered at risk. However, it is unclear whether this recommendation is based on scientific evidence or expert clinical opinion. This report reflects our effort to employ the systematic review protocol to assess whether there is scientific evidence to recommend an occlusal splint in bruxers after implant therapy.