Roman Schaffert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Roman Schaffert has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Anja Borsdorf
Siemens Healthineers AG, 91301 Forchheim, Germany
6 shared publicationsAndreas Maier
Graduate School in Advanced Optical Technologies (SAOT), 91058 Erlangen, Germany
4 shared publicationsJian Wang
Siemens Healthineers AG
4 shared publicationsPeter Fischer
Siemens Healthineers AG
3 shared publications- Andreas Maier
Friedrich-Alexander-Universität Erlangen-Nürnberg
2 shared publications - Jian Wang
Siemens Healthineers AG, 91301 Forchheim, Germany
2 shared publications
Latest Publications
- 16 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (10) , 3159-3174
Learning an Attention Model for Robust 2-D/3-D Registration Using Point-To-Plane Correspondences
Minimally invasive procedures rely on image guidance for navigation at the operation site to avoid large surgical incisions. images are often used for guidance, but important structures may be not well visible. These structures can be overlaid from pre-operative images and accurate alignment can be established using registration. Registration based on the point-to-plane correspondence model was recently proposed and shown to achieve performance. However, registration may still fail in challenging cases due to a large portion of outliers. In this paper, we describe a correspondence weighting scheme to improve the registration performance. By learning an attention model, inlier correspondences get higher attention in the motion estimation while the outlier correspondences are suppressed. Instead of using per-correspondence labels, our objective function allows to train the model directly by minimizing the registration error. We demonstrate a highly increased robustness, e.g. increasing the success rate from 84.9 % to 97.0 % for spine registration. In contrast to previously proposed methods, we also achieve a high accuracy of around 0.5 mm mean re-projection distance. In addition, our method requires a relatively small amount of training data, is able to learn from simulated data, and generalizes to images with additional structures which are not present during training. Furthermore, a single model can be trained for both, different views and different anatomical structures.
- 16 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (10) , 3159-3174
Learning an Attention Model for Robust 2-D/3-D Registration Using Point-To-Plane Correspondences
Minimally invasive procedures rely on image guidance for navigation at the operation site to avoid large surgical incisions. images are often used for guidance, but important structures may be not well visible. These structures can be overlaid from pre-operative images and accurate alignment can be established using registration. Registration based on the point-to-plane correspondence model was recently proposed and shown to achieve performance. However, registration may still fail in challenging cases due to a large portion of outliers. In this paper, we describe a correspondence weighting scheme to improve the registration performance. By learning an attention model, inlier correspondences get higher attention in the motion estimation while the outlier correspondences are suppressed. Instead of using per-correspondence labels, our objective function allows to train the model directly by minimizing the registration error. We demonstrate a highly increased robustness, e.g. increasing the success rate from 84.9 % to 97.0 % for spine registration. In contrast to previously proposed methods, we also achieve a high accuracy of around 0.5 mm mean re-projection distance. In addition, our method requires a relatively small amount of training data, is able to learn from simulated data, and generalizes to images with additional structures which are not present during training. Furthermore, a single model can be trained for both, different views and different anatomical structures.
- 12 February 2020
- Published by Springer Nature
- p. 222-228
Learning-Based Correspondence Estimation for 2-D/3-D Registration
- 12 February 2020
- Published by Springer Nature
- p. 222-228
Learning-Based Correspondence Estimation for 2-D/3-D Registration
- 12 February 2020
- Published by Springer Nature
- p. 230-235
Learning-Based Misalignment Detection for 2-D/3-D Overlays
- 12 February 2020
- Published by Springer Nature
- p. 230-235
Learning-Based Misalignment Detection for 2-D/3-D Overlays
- 13 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (1) , 161-174
Robust Multi-View 2-D/3-D Registration Using Point-To-Plane Correspondence Model
In minimally invasive procedures, the clinician relies on image guidance to observe and navigate the operation site. In order to show structures which are not visible in the live X-ray images, such as vessels or planning annotations, X-ray images can be augmented with pre-operatively acquired images. Accurate image alignment is needed and can be provided by 2-D/3-D registration. In this paper, a multi-view registration method based on the point-to-plane correspondence model is proposed. The correspondence model is extended to be independent of the used camera coordinates and different multi-view registration schemes are introduced and compared. Evaluation is performed for a wide range of clinically relevant registration scenarios. We show for different applications that registration using correspondences from both views simultaneously provides accurate and robust registration, while the performance of the other schemes varies considerably. Our method also outperforms the state-of-the-art method for cerebral angiography registration, achieving a capture range of 18 mm and an accuracy of 0.22±0.07 mm. Furthermore, investigations on the minimum angle between the views are performed in order to provide accurate and robust registration, while minimizing the obstruction to the clinical workflow. We show that small angles around 30° are sufficient to provide reliable registration results.
- 13 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (1) , 161-174
Robust Multi-View 2-D/3-D Registration Using Point-To-Plane Correspondence Model
In minimally invasive procedures, the clinician relies on image guidance to observe and navigate the operation site. In order to show structures which are not visible in the live X-ray images, such as vessels or planning annotations, X-ray images can be augmented with pre-operatively acquired images. Accurate image alignment is needed and can be provided by 2-D/3-D registration. In this paper, a multi-view registration method based on the point-to-plane correspondence model is proposed. The correspondence model is extended to be independent of the used camera coordinates and different multi-view registration schemes are introduced and compared. Evaluation is performed for a wide range of clinically relevant registration scenarios. We show for different applications that registration using correspondences from both views simultaneously provides accurate and robust registration, while the performance of the other schemes varies considerably. Our method also outperforms the state-of-the-art method for cerebral angiography registration, achieving a capture range of 18 mm and an accuracy of 0.22±0.07 mm. Furthermore, investigations on the minimum angle between the views are performed in order to provide accurate and robust registration, while minimizing the obstruction to the clinical workflow. We show that small angles around 30° are sufficient to provide reliable registration results.
- 14 February 2019
- Published by Springer Nature
- p. 140-152
Metric-Driven Learning of Correspondence Weighting for 2-D/3-D Image Registration
- 14 February 2019
- Published by Springer Nature
- p. 140-152
Metric-Driven Learning of Correspondence Weighting for 2-D/3-D Image Registration
- Open Access
Metric-Driven Learning of Correspondence Weighting for 2-D/3-D Image Registration
Registration of pre-operative 3-D volumes to intra-operative 2-D X-ray images is important in minimally invasive medical procedures. Rigid registration can be performed by estimating a global rigid motion that optimizes the alignment of local correspondences. However, inaccurate correspondences challenge the registration performance. To minimize their influence, we estimate optimal weights for correspondences using PointNet. We train the network directly with the criterion to minimize the registration error. We propose an objective function which includes point-to-plane correspondence-based motion estimation and projection error computation, thereby enabling the learning of a weighting strategy that optimally fits the underlying formulation of the registration task in an end-to-end fashion. For single-vertebra registration, we achieve an accuracy of 0.74$\pm$0.26 mm and highly improved robustness. The success rate is increased from 79.3 % to 94.3 % and the capture range from 3 mm to 13 mm.
Open AccessMetric-Driven Learning of Correspondence Weighting for 2-D/3-D Image Registration
Registration of pre-operative 3-D volumes to intra-operative 2-D X-ray images is important in minimally invasive medical procedures. Rigid registration can be performed by estimating a global rigid motion that optimizes the alignment of local correspondences. However, inaccurate correspondences challenge the registration performance. To minimize their influence, we estimate optimal weights for correspondences using PointNet. We train the network directly with the criterion to minimize the registration error. We propose an objective function which includes point-to-plane correspondence-based motion estimation and projection error computation, thereby enabling the learning of a weighting strategy that optimally fits the underlying formulation of the registration task in an end-to-end fashion. For single-vertebra registration, we achieve an accuracy of 0.74$\pm$0.26 mm and highly improved robustness. The success rate is increased from 79.3 % to 94.3 % and the capture range from 3 mm to 13 mm.