Andrea Perego
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andrea Perego has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Iryna V. Zenyuk
University of California
8 shared publications - Fabio Di Fonzo
Istituto Italiano di Tecnologia
3 shared publications Michael Metzger
Robert Bosch LLC
3 shared publicationsMorteza Rezaei Talarposhti
University of California Irvine
3 shared publicationsNathan Craig
Robert Bosch LLC
3 shared publicationsNobumichi Tamura
3 shared publications
Latest Publications
- Open Access
Boosting the performance of polymer electrolyte membrane fuel cells with porous flow fields: Pros and cons
- Open Access
- 2 August 2021
- Published by Wiley in ChemElectroChem
- Vol. 8 (15) , 2846-2857
Hierarchical TiN‐Supported TsFDH Nanobiocatalyst for CO2 Reduction to Formate
The electrochemical reduction of CO2 to value‐added products like formate represents a promising technology for the valorization of carbon dioxide. We propose a proof‐of‐concept bioelectrochemical system (BES) for the reduction of CO2 to formate. For the first time, our device employs a nanostructured titanium nitride (TiN) support for the immobilization of a formate dehydrogenase (FDH) enzyme. The hierarchical TiN nanostructured support exhibits high surface area and wide pore size distribution, achieving high catalytic loading, and is characterized by higher conductivity than other oxide‐based supports employed for FDHs immobilization. We select the oxygen‐tolerant FDH from Thiobacillus sp. KNK65MA (TsFDH) as enzymatic catalyst, which selectively reduces CO2 to formate. We identify an optimal TiN morphology for the enzyme immobilisation through enzymatic assay, reaching a catalyst loading of 59 μg cm−2 of specifically‐adsorbed TsFDH and achieving a complete saturation of the anchoring sites available on the surface. We evaluate the electrochemical CO2 reduction performance of the TiN/TsFDH system, achieving a remarkable HCOO− Faradaic efficiency up to 76 %, a maximum formate yield of 44.1 μmol mg−1FDH h−1 and high stability. Our results show the technological feasibility of BES devices employing novel, nanostructured TiN‐based supports, representing an important step in the optimization of these devices.
- 2 August 2021
- Published by Wiley in ChemElectroChem
- Vol. 8 (15) , 2846-2857
Open AccessHierarchical TiN‐Supported TsFDH Nanobiocatalyst for CO2 Reduction to Formate
The electrochemical reduction of CO2 to value‐added products like formate represents a promising technology for the valorization of carbon dioxide. We propose a proof‐of‐concept bioelectrochemical system (BES) for the reduction of CO2 to formate. For the first time, our device employs a nanostructured titanium nitride (TiN) support for the immobilization of a formate dehydrogenase (FDH) enzyme. The hierarchical TiN nanostructured support exhibits high surface area and wide pore size distribution, achieving high catalytic loading, and is characterized by higher conductivity than other oxide‐based supports employed for FDHs immobilization. We select the oxygen‐tolerant FDH from Thiobacillus sp. KNK65MA (TsFDH) as enzymatic catalyst, which selectively reduces CO2 to formate. We identify an optimal TiN morphology for the enzyme immobilisation through enzymatic assay, reaching a catalyst loading of 59 μg cm−2 of specifically‐adsorbed TsFDH and achieving a complete saturation of the anchoring sites available on the surface. We evaluate the electrochemical CO2 reduction performance of the TiN/TsFDH system, achieving a remarkable HCOO− Faradaic efficiency up to 76 %, a maximum formate yield of 44.1 μmol mg−1FDH h−1 and high stability. Our results show the technological feasibility of BES devices employing novel, nanostructured TiN‐based supports, representing an important step in the optimization of these devices.
- Open Access
- 30 April 2021
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 168 (5) , 054502
Interpreting Ionic Conductivity for Polymer Electrolyte Fuel Cell Catalyst Layers with Electrochemical Impedance Spectroscopy and Transmission Line Modeling
A cathode catalyst layer containing optimally distributed ionomer is critical to reduce the platinum loading and increase its utilization in polymer electrolyte fuel cells. Here, electrochemical impedance spectroscopy (EIS) was used to measure effective ionic conductivity of pseudo catalyst layers (PCLs) at a relative humidity (RH) range of 50%–120%. These results are compared to previous work using the hydrogen pump (HP) method. EIS effective ionic conductivity results reported here are higher than those from the HP because in the HP set-up ionic pathways must be effectively connected through the PCL to be counted, whereas in the EIS measurement, ionomer segments that are in contact with the membrane but are not effectively connected all the way through the PCL can be detected. Double layer capacitances and effective ionic conductivities of Pt/C catalyst layers with various supports and ionomer to carbon (I/C) ratios were studied. High surface area carbon support resulted in a lower effective ionic conductivity compared to the graphitized carbon support due to worse ionomer dispersion. Effective ionic conductivities of Pt/C layers were compared to that of PCLs. On average, effective ionic conductivities of Pt/C layers were higher than PCLs because of possible carbon agglomeration within the PCLs.
- 30 April 2021
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 168 (5) , 054502
Open AccessInterpreting Ionic Conductivity for Polymer Electrolyte Fuel Cell Catalyst Layers with Electrochemical Impedance Spectroscopy and Transmission Line Modeling
A cathode catalyst layer containing optimally distributed ionomer is critical to reduce the platinum loading and increase its utilization in polymer electrolyte fuel cells. Here, electrochemical impedance spectroscopy (EIS) was used to measure effective ionic conductivity of pseudo catalyst layers (PCLs) at a relative humidity (RH) range of 50%–120%. These results are compared to previous work using the hydrogen pump (HP) method. EIS effective ionic conductivity results reported here are higher than those from the HP because in the HP set-up ionic pathways must be effectively connected through the PCL to be counted, whereas in the EIS measurement, ionomer segments that are in contact with the membrane but are not effectively connected all the way through the PCL can be detected. Double layer capacitances and effective ionic conductivities of Pt/C catalyst layers with various supports and ionomer to carbon (I/C) ratios were studied. High surface area carbon support resulted in a lower effective ionic conductivity compared to the graphitized carbon support due to worse ionomer dispersion. Effective ionic conductivities of Pt/C layers were compared to that of PCLs. On average, effective ionic conductivities of Pt/C layers were higher than PCLs because of possible carbon agglomeration within the PCLs.
- Open Access
- 25 November 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 8 (47) , 25283-25289
Humidity-robust scalable metal halide perovskite film deposition for photovoltaic applications
Organic–inorganic perovskite photovoltaics have now achieved power conversion efficiencies at par with silicon devices on a lab-scale. To enable industrial application of the technology, developing a perovskite deposition route compatible with scalable, large-area deposition methods, which exploits safer processing solvents and is robust to variations of the processing parameters, particularly humidity, is highly demanded. To satisfy such constraints altogether, here we introduce a lead iodide–hydroiodic acid–water precursor (PbI2–HI–H2O) that enables the scalable deposition of methylammonium lead triiodide (MAPbI3) films from a safer solvent (acetonitrile – ACN) in a wide range of high moisture levels, spanning from 50 to 80% relative humidity. When exposed to a methylamine (MA) gas flow the PbI2–HI–H2O precursor readily converts to specular perovskite films. If heated, the PbI2–HI–H2O film can be easily reverted to PbI2, further enabling the implementation of two step deposition methods. Our process was tested in an inverted solar cell configuration achieving stabilized power conversion efficiencies of 14% with minimal annealing requirements. Our findings demonstrate an appealing route for a large-area compatible manufacturing of hybrid perovskite photovoltaics in air, at high moisture levels, based on solvents of reduced hazard.
- 25 November 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 8 (47) , 25283-25289
Open AccessHumidity-robust scalable metal halide perovskite film deposition for photovoltaic applications
Organic–inorganic perovskite photovoltaics have now achieved power conversion efficiencies at par with silicon devices on a lab-scale. To enable industrial application of the technology, developing a perovskite deposition route compatible with scalable, large-area deposition methods, which exploits safer processing solvents and is robust to variations of the processing parameters, particularly humidity, is highly demanded. To satisfy such constraints altogether, here we introduce a lead iodide–hydroiodic acid–water precursor (PbI2–HI–H2O) that enables the scalable deposition of methylammonium lead triiodide (MAPbI3) films from a safer solvent (acetonitrile – ACN) in a wide range of high moisture levels, spanning from 50 to 80% relative humidity. When exposed to a methylamine (MA) gas flow the PbI2–HI–H2O precursor readily converts to specular perovskite films. If heated, the PbI2–HI–H2O film can be easily reverted to PbI2, further enabling the implementation of two step deposition methods. Our process was tested in an inverted solar cell configuration achieving stabilized power conversion efficiencies of 14% with minimal annealing requirements. Our findings demonstrate an appealing route for a large-area compatible manufacturing of hybrid perovskite photovoltaics in air, at high moisture levels, based on solvents of reduced hazard.
- 23 November 2020
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2020-02 (36) , 2325
Catalyst Degradation in Polymer Electrolyte Fuel Cells with Multi-Modal Techniques: Understanding Phenomena Under Varied Gas and Relative Humidity
For widespread commercialization of polymer electrolyte fuel cells (PEFCs), cost and durability need to be addressed. Reduction in cost should not negatively affect PEFC durability and performance. At high volume production, platinum (Pt) electro catalyst contributes to 41% of the total fuel cell stack cost for light duty vehicles. This cost contribution increases to 53% for middle and heavy-duty vehicles. When membrane electrode assemblies (MEAs) are designed for durability, this cost will increase further. A complex balance exists between cost, performance and durability. With smaller nanoparticle size better Pt dispersion is achieved which gives improved performance and reduces Pt loading and cost. But this negatively affects durability, as smaller nanoparticles have higher surface energy which causes faster electrocatalyst degradation1. During an actual drive cycle, PEFCs need to operate over a wide range of operating conditions such as temperature (-40C to 120C), potential (0V to 1.5V) and relative humidity which can further accelerate Pt dissolution Under load cycling during typical drive cycle, repeated oxidation and reduction of Pt surface leads to Pt dissolution2. Dissolved Pt ions redeposit on nearby nanoparticles effectively increasing their particle size2. This electrochemical surface area (ECSA) loss via increase in particle size is well known as Ostwald ripening. Some Pt ions are reduced in the electrolyte membrane by crossover hydrogen which leads to formation of a Pt band, usually at the membrane and cathode catalyst layer interface3. At > 1V, carbon corrosion can lead to Pt detachment2. This can happen during start-up/shut down cycles when anode is exposed to hydrogen and air. Such degradation mechanisms need to be studied systematically with effect of operating conditions like gas flow rates, temperature and relative humidity under dynamic load cycling. In this study, we investigate the effect of cathode gas environment and gas flow rates on Pt particle size during aging experiment. A DOE adopted accelerated stress test (AST) protocol simulating the drive cycle operating conditions is used. It consists of a 0.6 V – 0.95 V square wave with 3s hold time at each potential. In situ electrochemical characterization at regular stages is used to identify ECSA loss trends and polarization performance. Figure 1 shows normalized ECSA loss for the four cells cycled in different environments during catalyst AST. Measurements were taken beginning of life (BOL), after 1,000, 5,000, 15,000 and 30,000 cycles. We observed that the cell that was cycled in N2 and 100 % RH degraded the most , having 25 % of ECSA left after 30,000 cycles compared to BOL. Electrochemical measurements are supplemented by detailed post-mortem ex-situ x-ray characterization by using micro x-ray fluorescence, x- ray computed tomography and micro x-ray diffraction, SEM-EDS. 1cm2 active areas of the catalyst layer at the inlet, middle and outlet of the flow field were mapped using micro x-ray diffraction to understand Pt particle size distribution under land/channel. Catalyst layer loading before and after the AST were confirmed using micro x-ray fluorescence. References (1) Cherevko, S.; Kulyk, N.; Mayrhofer, K. J. J. Durability of Platinum-Based Fuel Cell Electrocatalysts: Dissolution of Bulk and Nanoscale Platinum. Nano Energy 2016, 29, 275–298. https://doi.org/10.1016/j.nanoen.2016.03.005. (2) Meier, J. C.; Galeano, C.; Katsounaros, I.; Witte, J.; Bongard, H. J.; Topalov, A. A.; Baldizzone, C.; Mezzavilla, S.; Schüth, F.; Mayrhofer, K. J. J. Design Criteria for Stable Pt/C Fuel Cell Catalysts. Beilstein J. Nanotechnol. 2014, 5 (1), 44–67. https://doi.org/10.3762/bjnano.5.5. (3) Zhang, J.; Litteer, B. A.; Gu, W.; Liu, H.; Gasteiger, H. A. Effect of Hydrogen and Oxygen Partial Pressure on Pt Precipitation within the Membrane of PEMFCs. J. Electrochem. Soc. 2007, 154 (10), B1006. https://doi.org/10.1149/1.2764240. Figure 1
- 23 November 2020
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2020-02 (36) , 2325
Catalyst Degradation in Polymer Electrolyte Fuel Cells with Multi-Modal Techniques: Understanding Phenomena Under Varied Gas and Relative Humidity
For widespread commercialization of polymer electrolyte fuel cells (PEFCs), cost and durability need to be addressed. Reduction in cost should not negatively affect PEFC durability and performance. At high volume production, platinum (Pt) electro catalyst contributes to 41% of the total fuel cell stack cost for light duty vehicles. This cost contribution increases to 53% for middle and heavy-duty vehicles. When membrane electrode assemblies (MEAs) are designed for durability, this cost will increase further. A complex balance exists between cost, performance and durability. With smaller nanoparticle size better Pt dispersion is achieved which gives improved performance and reduces Pt loading and cost. But this negatively affects durability, as smaller nanoparticles have higher surface energy which causes faster electrocatalyst degradation1. During an actual drive cycle, PEFCs need to operate over a wide range of operating conditions such as temperature (-40C to 120C), potential (0V to 1.5V) and relative humidity which can further accelerate Pt dissolution Under load cycling during typical drive cycle, repeated oxidation and reduction of Pt surface leads to Pt dissolution2. Dissolved Pt ions redeposit on nearby nanoparticles effectively increasing their particle size2. This electrochemical surface area (ECSA) loss via increase in particle size is well known as Ostwald ripening. Some Pt ions are reduced in the electrolyte membrane by crossover hydrogen which leads to formation of a Pt band, usually at the membrane and cathode catalyst layer interface3. At > 1V, carbon corrosion can lead to Pt detachment2. This can happen during start-up/shut down cycles when anode is exposed to hydrogen and air. Such degradation mechanisms need to be studied systematically with effect of operating conditions like gas flow rates, temperature and relative humidity under dynamic load cycling. In this study, we investigate the effect of cathode gas environment and gas flow rates on Pt particle size during aging experiment. A DOE adopted accelerated stress test (AST) protocol simulating the drive cycle operating conditions is used. It consists of a 0.6 V – 0.95 V square wave with 3s hold time at each potential. In situ electrochemical characterization at regular stages is used to identify ECSA loss trends and polarization performance. Figure 1 shows normalized ECSA loss for the four cells cycled in different environments during catalyst AST. Measurements were taken beginning of life (BOL), after 1,000, 5,000, 15,000 and 30,000 cycles. We observed that the cell that was cycled in N2 and 100 % RH degraded the most , having 25 % of ECSA left after 30,000 cycles compared to BOL. Electrochemical measurements are supplemented by detailed post-mortem ex-situ x-ray characterization by using micro x-ray fluorescence, x- ray computed tomography and micro x-ray diffraction, SEM-EDS. 1cm2 active areas of the catalyst layer at the inlet, middle and outlet of the flow field were mapped using micro x-ray diffraction to understand Pt particle size distribution under land/channel. Catalyst layer loading before and after the AST were confirmed using micro x-ray fluorescence. References (1) Cherevko, S.; Kulyk, N.; Mayrhofer, K. J. J. Durability of Platinum-Based Fuel Cell Electrocatalysts: Dissolution of Bulk and Nanoscale Platinum. Nano Energy 2016, 29, 275–298. https://doi.org/10.1016/j.nanoen.2016.03.005. (2) Meier, J. C.; Galeano, C.; Katsounaros, I.; Witte, J.; Bongard, H. J.; Topalov, A. A.; Baldizzone, C.; Mezzavilla, S.; Schüth, F.; Mayrhofer, K. J. J. Design Criteria for Stable Pt/C Fuel Cell Catalysts. Beilstein J. Nanotechnol. 2014, 5 (1), 44–67. https://doi.org/10.3762/bjnano.5.5. (3) Zhang, J.; Litteer, B. A.; Gu, W.; Liu, H.; Gasteiger, H. A. Effect of Hydrogen and Oxygen Partial Pressure on Pt Precipitation within the Membrane of PEMFCs. J. Electrochem. Soc. 2007, 154 (10), B1006. https://doi.org/10.1149/1.2764240. Figure 1
- 23 November 2020
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2020-02 (33) , 2162
Evolution of Ionomer Coverage during Accelerated Stress Tests in Polymer Electrolyte Fuel Cells
Despite the current readiness level and the market availability of the polymer electrolyte fuel cells (PEFCs) durability is still a technical challenge that the technology, has to resolve to become competitive with internal combustion engines (ICE). In the automotive sector, the ICE engines typically reach lifetimes of more than a decade. In the nearest future PEFCs can become competitive in the medium to heavy-duty vehicles sector, where the space constraints and the power density requirements are more relaxed, but cell lifetime becomes of critical importance for such vehicles, that drive for up to 100,000 miles per year. Accelerated stress tests (ASTs) are used to assess the lifetime of a PEFC in a limited amount of time. the US Drive Fuel Cell Technical Team of the US DOE adopted several protocols targeting specific components of the cell or ageing phenomena (platinum dissolution or carbon corrosion). In the PEFC cathode electrode ionomer is added to enable proton transport to the electrocatalyst. Ionomer forms thin films around Pt/C agglomerates. The SO3 - groups (from the side chains of PFSA-based polymer ionomers) adsorb onto the platinum surface and reduce its overall specific activity. Additionally, when Nafion ionomer that has crystalline backbone aligns parallel to the catalyst surface it impedes local oxygen transport1 . Recent study did not show direct correlation between SO3 - group coverage and specific mass activity, when the coverage was varied from 0.16 to 0.262 . This may be because even with 0.16 coverage Pt has already been ‘poisoned’ and further addition of ionomer can actually have a positive effect enhancing proton accessibility. Understanding the behavior of the ionomer in the electrode and its evolution during the cell lifetime is of great importance, but at the present the literature does not show durability studies focused on this aspect. In this contribution, we aim to investigate and understand the coverage of the ionomer on Pt and carbon and SO3- groups adsorption in a PEFC during ASTs. CO stripping and displacement were used to probe the ionomer coverage as described by Garrick et al.3 Two types of cells were investigated using carbon corrosion AST: the first one with traditional carbon material and the second one with start/stop tolerant catalyst support. While the tolerant support led to small performance decrease and ECSA loss, the cell without start/stop tolerant support saw a sharp decrease in the ionomer coverage in the electrode between 100 and 500 cycles, that corresponded to a considerable loss in polarization. The ECSA was not changed between 100 to 500 cycles indicating that Pt loss was not a reason for polarization decrease and therefore we attribute the cause of the cell failure mainly to the loss of ionomer. Catalyst AST was also investigated, and the ionomer coverage was measured both in dry and wet conditions to separate the contribution of the interfaces between platinum/ionomer and platinum/water as in Iden and Ohma work4. By comparing the ECSA in dry and wet conditions, we see that while ECSA in wet condition decreases (that corresponds to the total ECSA reachable by protons) the dry ECSA (that considers only the Pt portion contacted by ionomer) remains constant. This behavior, coupled with an ionomer coverage that remains rather constant during the cycling, suggests that Pt dissolution is accelerated in the regions where Pt is not covered by ionomer. This work highlights the importance of the ionomer coverage and its evolution during aging. It suggests the role of ionomer is critical for catalyst stability in both carbon corrosion and catalyst ASTs. References: Shinozaki, K. et al. Special Feature : Popularizing Fuel Cell Vehicles : Designing and Controlling Electrochemical Reactions in the MEA Oxygen Reduction Reaction Activity Measurement for Fuel Cell Catalysts Using the Rotating Disk Electrode Technique. 49, 33–46 (2018). Van Cleve, T. et al. Dictating Pt-Based Electrocatalyst Performance in Polymer Electrolyte Fuel Cells, from Formulation to Application. ACS Appl. Mater. Interfaces 11, 46953–46964 (2019). Garrick, T. R., Moylan, T. E., Yarlagadda, V. & Kongkanand, A. Characterizing Electrolyte and Platinum Interface in PEM Fuel Cells Using CO Displacement. J. Electrochem. Soc. 164, F60–F64 (2017). Iden, H. & Ohma, A. An in situ technique for analyzing ionomer coverage in catalyst layers. J. Electroanal. Chem. 693, 34–41 (2013).
- 23 November 2020
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2020-02 (33) , 2162
Evolution of Ionomer Coverage during Accelerated Stress Tests in Polymer Electrolyte Fuel Cells
Despite the current readiness level and the market availability of the polymer electrolyte fuel cells (PEFCs) durability is still a technical challenge that the technology, has to resolve to become competitive with internal combustion engines (ICE). In the automotive sector, the ICE engines typically reach lifetimes of more than a decade. In the nearest future PEFCs can become competitive in the medium to heavy-duty vehicles sector, where the space constraints and the power density requirements are more relaxed, but cell lifetime becomes of critical importance for such vehicles, that drive for up to 100,000 miles per year. Accelerated stress tests (ASTs) are used to assess the lifetime of a PEFC in a limited amount of time. the US Drive Fuel Cell Technical Team of the US DOE adopted several protocols targeting specific components of the cell or ageing phenomena (platinum dissolution or carbon corrosion). In the PEFC cathode electrode ionomer is added to enable proton transport to the electrocatalyst. Ionomer forms thin films around Pt/C agglomerates. The SO3 - groups (from the side chains of PFSA-based polymer ionomers) adsorb onto the platinum surface and reduce its overall specific activity. Additionally, when Nafion ionomer that has crystalline backbone aligns parallel to the catalyst surface it impedes local oxygen transport1 . Recent study did not show direct correlation between SO3 - group coverage and specific mass activity, when the coverage was varied from 0.16 to 0.262 . This may be because even with 0.16 coverage Pt has already been ‘poisoned’ and further addition of ionomer can actually have a positive effect enhancing proton accessibility. Understanding the behavior of the ionomer in the electrode and its evolution during the cell lifetime is of great importance, but at the present the literature does not show durability studies focused on this aspect. In this contribution, we aim to investigate and understand the coverage of the ionomer on Pt and carbon and SO3- groups adsorption in a PEFC during ASTs. CO stripping and displacement were used to probe the ionomer coverage as described by Garrick et al.3 Two types of cells were investigated using carbon corrosion AST: the first one with traditional carbon material and the second one with start/stop tolerant catalyst support. While the tolerant support led to small performance decrease and ECSA loss, the cell without start/stop tolerant support saw a sharp decrease in the ionomer coverage in the electrode between 100 and 500 cycles, that corresponded to a considerable loss in polarization. The ECSA was not changed between 100 to 500 cycles indicating that Pt loss was not a reason for polarization decrease and therefore we attribute the cause of the cell failure mainly to the loss of ionomer. Catalyst AST was also investigated, and the ionomer coverage was measured both in dry and wet conditions to separate the contribution of the interfaces between platinum/ionomer and platinum/water as in Iden and Ohma work4. By comparing the ECSA in dry and wet conditions, we see that while ECSA in wet condition decreases (that corresponds to the total ECSA reachable by protons) the dry ECSA (that considers only the Pt portion contacted by ionomer) remains constant. This behavior, coupled with an ionomer coverage that remains rather constant during the cycling, suggests that Pt dissolution is accelerated in the regions where Pt is not covered by ionomer. This work highlights the importance of the ionomer coverage and its evolution during aging. It suggests the role of ionomer is critical for catalyst stability in both carbon corrosion and catalyst ASTs. References: Shinozaki, K. et al. Special Feature : Popularizing Fuel Cell Vehicles : Designing and Controlling Electrochemical Reactions in the MEA Oxygen Reduction Reaction Activity Measurement for Fuel Cell Catalysts Using the Rotating Disk Electrode Technique. 49, 33–46 (2018). Van Cleve, T. et al. Dictating Pt-Based Electrocatalyst Performance in Polymer Electrolyte Fuel Cells, from Formulation to Application. ACS Appl. Mater. Interfaces 11, 46953–46964 (2019). Garrick, T. R., Moylan, T. E., Yarlagadda, V. & Kongkanand, A. Characterizing Electrolyte and Platinum Interface in PEM Fuel Cells Using CO Displacement. J. Electrochem. Soc. 164, F60–F64 (2017). Iden, H. & Ohma, A. An in situ technique for analyzing ionomer coverage in catalyst layers. J. Electroanal. Chem. 693, 34–41 (2013).
- Open Access
- 23 November 2020
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2020-02 (53) , 3743
Interpreting Ionic Conductivity for Polymer Electrolyte Fuel Cell Catalyst Layers with Electrochemical Impedance Spectroscopy and Transmission Line Modeling
An optimal cathode catalyst layer with uniform ionomer distribution is critical to reduce the platinum loading and increase the utilization in polymer electrolyte fuel cells (PEFCs). Having well distributed ionomer with low ionomer to carbon (I/C) ratio is desirable, as it will also minimize local oxygen transport resistance. In this work, we used electrochemical impedance spectroscopy (EIS) method and transmission line model (TLM) to measure and evaluate ionic conductivity of pseudo catalyst layers (PCLs) comprised of Vulcan XC72 carbon black and 3M 825 EW ionomer with I/C ratios of 0.3, 0.6, 1 and 1.4 at a relative humidity (RH) range of 50 to 120 %. These results were compared with our previous hydrogen pump (HP) measurements, where PCL was sandwiched between the two membranes and protons had to transport through the entire PCL to be counted towards current. EIS effective ionic conductivity results reported here are higher than the results of HP because in the HP set-up ionic pathways must percolate all the way through the PCL to be effectively counted, whereas in EIS measurement, ionomer segments that are in contact with the membrane but not percolating all the way through the PCL can be detected. Additionally, three effects were studied: 1) hot press, 2) platinum content and carbon black support, and 3) ionomer content or lack of ionomer. Ionic conductivity increased significantly by hot pressing PCL onto the membrane, however, it was independent with respect to the hot press conditions, such as pressure and temperature. Hot pressing with low I/C ratio had more impact than high I/C ratio because at high I/C ratio even without hot press there is a sufficient amount of contact points between catalyst layer and membrane. At high RHs, catalyst layer containing Pt has higher ionic conductivity compared to PCL because of Pt particles being hydrophilic, which helps to distribute the ionomer more uniformly. To investigate the effect of condensed water, PTFE dispersion was used as a binder for Pt/C layer instead of ionomer, resulting ionic conductivity decreased with increasing applied potential at 100% and 120% RH conditions. At lower RHs, ionic conductivity is independent of the applied potentials.
- 23 November 2020
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2020-02 (53) , 3743
Open AccessInterpreting Ionic Conductivity for Polymer Electrolyte Fuel Cell Catalyst Layers with Electrochemical Impedance Spectroscopy and Transmission Line Modeling
An optimal cathode catalyst layer with uniform ionomer distribution is critical to reduce the platinum loading and increase the utilization in polymer electrolyte fuel cells (PEFCs). Having well distributed ionomer with low ionomer to carbon (I/C) ratio is desirable, as it will also minimize local oxygen transport resistance. In this work, we used electrochemical impedance spectroscopy (EIS) method and transmission line model (TLM) to measure and evaluate ionic conductivity of pseudo catalyst layers (PCLs) comprised of Vulcan XC72 carbon black and 3M 825 EW ionomer with I/C ratios of 0.3, 0.6, 1 and 1.4 at a relative humidity (RH) range of 50 to 120 %. These results were compared with our previous hydrogen pump (HP) measurements, where PCL was sandwiched between the two membranes and protons had to transport through the entire PCL to be counted towards current. EIS effective ionic conductivity results reported here are higher than the results of HP because in the HP set-up ionic pathways must percolate all the way through the PCL to be effectively counted, whereas in EIS measurement, ionomer segments that are in contact with the membrane but not percolating all the way through the PCL can be detected. Additionally, three effects were studied: 1) hot press, 2) platinum content and carbon black support, and 3) ionomer content or lack of ionomer. Ionic conductivity increased significantly by hot pressing PCL onto the membrane, however, it was independent with respect to the hot press conditions, such as pressure and temperature. Hot pressing with low I/C ratio had more impact than high I/C ratio because at high I/C ratio even without hot press there is a sufficient amount of contact points between catalyst layer and membrane. At high RHs, catalyst layer containing Pt has higher ionic conductivity compared to PCL because of Pt particles being hydrophilic, which helps to distribute the ionomer more uniformly. To investigate the effect of condensed water, PTFE dispersion was used as a binder for Pt/C layer instead of ionomer, resulting ionic conductivity decreased with increasing applied potential at 100% and 120% RH conditions. At lower RHs, ionic conductivity is independent of the applied potentials.
- 23 November 2020
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2020-02 (33) , 2163
Mapping of Heterogeneous Catalyst Degradation in Polymer Electrolyte Fuel Cells
Durability of cathode catalyst in polymer electrolyte fuel cells (PEFCs) is a key factor, limiting large-scale commercialization of PEFC for transportation applications. The catalyst degradation occurs during operational load profiles switches from ideal to peak, where multiple operational factors affect the degradation rate. The catalyst degrades heterogeneously as the catalyst particles are exposed to local variations throughout the entire catalyst layer during operation. State-of-the-art analytical techniques for studying degradation of Pt catalyst do not possess fine spatial resolution to elucidate such non-uniform degradation behavior at a large electrode level. We report a new methodology to spatially resolve and quantify the heterogeneous Pt catalyst degradation over a large area (several cm2) of aged MEAs based on synchrotron X-ray micro-diffraction. PEFC samples were aged using voltage cycling as an accelerated stress test. The heterogeneity of catalyst degradation at a micrometer length scale was visualized by mapping Pt catalyst particle size after voltage cycling between 0.6V and open circuit potential. We demonstrated in details that the Pt catalyst particle size growth was non-uniform and followed the flow field geometry. The Pt particle size growth was greater in the area under the flow field land, while it was minimal in the area under the flow field channel. Additional non-uniformity was observed with the Pt particle size increasing more rapidly at the gas outlet area of than the Pt particle size at the inlet area. Figure 1
- 23 November 2020
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2020-02 (33) , 2163
Mapping of Heterogeneous Catalyst Degradation in Polymer Electrolyte Fuel Cells
Durability of cathode catalyst in polymer electrolyte fuel cells (PEFCs) is a key factor, limiting large-scale commercialization of PEFC for transportation applications. The catalyst degradation occurs during operational load profiles switches from ideal to peak, where multiple operational factors affect the degradation rate. The catalyst degrades heterogeneously as the catalyst particles are exposed to local variations throughout the entire catalyst layer during operation. State-of-the-art analytical techniques for studying degradation of Pt catalyst do not possess fine spatial resolution to elucidate such non-uniform degradation behavior at a large electrode level. We report a new methodology to spatially resolve and quantify the heterogeneous Pt catalyst degradation over a large area (several cm2) of aged MEAs based on synchrotron X-ray micro-diffraction. PEFC samples were aged using voltage cycling as an accelerated stress test. The heterogeneity of catalyst degradation at a micrometer length scale was visualized by mapping Pt catalyst particle size after voltage cycling between 0.6V and open circuit potential. We demonstrated in details that the Pt catalyst particle size growth was non-uniform and followed the flow field geometry. The Pt particle size growth was greater in the area under the flow field land, while it was minimal in the area under the flow field channel. Additional non-uniformity was observed with the Pt particle size increasing more rapidly at the gas outlet area of than the Pt particle size at the inlet area. Figure 1
- 8 June 2020
- Published by Wiley in Advanced Energy Materials
- Vol. 10 (28) , 2000623
Mapping of Heterogeneous Catalyst Degradation in Polymer Electrolyte Fuel Cells
Pt catalysts in polymer electrolyte fuel cells degrade heterogeneously as the catalyst particles are exposed to local variations throughout the catalyst layer during operation. State‐of‐the‐art analytical techniques for studying degradation of Pt catalysts do not possess fine spatial resolution to elucidate such non‐uniform degradation behavior at a large electrode level. A new methodology is developed to spatially resolve and quantify the heterogeneous Pt catalyst degradation over a large area (several cm2) of aged MEAs based on synchrotron X‐ray microdiffraction. PEFC single cells are aged using voltage cycling as an accelerated stress test and the degradation heterogeneity at a micrometer length scale is visualized by mapping Pt catalyst particle size after voltage cycling. It is demonstrated in detail that the Pt catalyst particle size growth is non‐uniform and follows the flow field geometry. The Pt particle size growth is greater in the area under the flow field land, while it is minimal in the area under the flow field channel. Additional non‐uniformity is observed with the Pt particle size increasing more rapidly at the air outlet area than the Pt particle size at the inlet area.
- 8 June 2020
- Published by Wiley in Advanced Energy Materials
- Vol. 10 (28) , 2000623
Mapping of Heterogeneous Catalyst Degradation in Polymer Electrolyte Fuel Cells
Pt catalysts in polymer electrolyte fuel cells degrade heterogeneously as the catalyst particles are exposed to local variations throughout the catalyst layer during operation. State‐of‐the‐art analytical techniques for studying degradation of Pt catalysts do not possess fine spatial resolution to elucidate such non‐uniform degradation behavior at a large electrode level. A new methodology is developed to spatially resolve and quantify the heterogeneous Pt catalyst degradation over a large area (several cm2) of aged MEAs based on synchrotron X‐ray microdiffraction. PEFC single cells are aged using voltage cycling as an accelerated stress test and the degradation heterogeneity at a micrometer length scale is visualized by mapping Pt catalyst particle size after voltage cycling. It is demonstrated in detail that the Pt catalyst particle size growth is non‐uniform and follows the flow field geometry. The Pt particle size growth is greater in the area under the flow field land, while it is minimal in the area under the flow field channel. Additional non‐uniformity is observed with the Pt particle size increasing more rapidly at the air outlet area than the Pt particle size at the inlet area.
- Open Access
- 5 January 2020
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 167 (8) , 084521
Determining Proton Transport in Pseudo Catalyst Layers Using Hydrogen Pump DC and AC Techniques
Optimizing electrode morphology with a more uniform ionomer distribution is key to reducing ohmic losses and increasing electrocatalyst utilization in polymer electrolyte fuel cells (PEFCs). Inherent ionomer conductivity, volume fraction and tortuosity determine effective ionic conductivity. We use hydrogen pump (HP) method to measure effective ionic conductivity of a pseudo catalyst layer (PCL) comprised of Vulcan XC-72 carbon black and 3M 825 EW ionomer with ionomer to carbon (I/C) ratios of 0.6, 1 and 1.4 and relative humidity (RH) range of 50 to 120%. These direct current (DC) experiments are then compared with electrochemical impedance spectroscopy (EIS). Both DC and EIS methods show good agreement, indicating that EIS can be used as an alternative to DC method in HP experiment. Ionic conductivity for PCL with I/C of 1 and 1.4 was found to be about one order of magnitude higher than I/C of 0.6 for most of the RH range. At 90% RH tortuosities for I/C = 1 and 1.4 were close to 1, whereas tortuosity for I/C = 0.6 was 3. With decrease in relative humidity tortuosities increased linearly and at 50% relative humidity a PCL with I/C = 0.6 had the highest tortuosity of 6.1.
- 5 January 2020
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 167 (8) , 084521
Open AccessDetermining Proton Transport in Pseudo Catalyst Layers Using Hydrogen Pump DC and AC Techniques
Optimizing electrode morphology with a more uniform ionomer distribution is key to reducing ohmic losses and increasing electrocatalyst utilization in polymer electrolyte fuel cells (PEFCs). Inherent ionomer conductivity, volume fraction and tortuosity determine effective ionic conductivity. We use hydrogen pump (HP) method to measure effective ionic conductivity of a pseudo catalyst layer (PCL) comprised of Vulcan XC-72 carbon black and 3M 825 EW ionomer with ionomer to carbon (I/C) ratios of 0.6, 1 and 1.4 and relative humidity (RH) range of 50 to 120%. These direct current (DC) experiments are then compared with electrochemical impedance spectroscopy (EIS). Both DC and EIS methods show good agreement, indicating that EIS can be used as an alternative to DC method in HP experiment. Ionic conductivity for PCL with I/C of 1 and 1.4 was found to be about one order of magnitude higher than I/C of 0.6 for most of the RH range. At 90% RH tortuosities for I/C = 1 and 1.4 were close to 1, whereas tortuosity for I/C = 0.6 was 3. With decrease in relative humidity tortuosities increased linearly and at 50% relative humidity a PCL with I/C = 0.6 had the highest tortuosity of 6.1.