Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yin-Yu Chang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enhancement of a Magnetically Controlled Cathodic Arc Source for the Deposition of Multi-Component Hard Nitride Coatings

    by Van-Tien Tang, Yin-Yu Chang, Yi-Ru Chen

    The creation of coatings by the cathodic arc evaporation method has outstanding advantages: these coatings are highly durable and wear-resistant, especially since the method has an intense ionization process and the atoms can penetrate deep into the surface substrates, resulting in excellent adhesion. Furthermore, this approach provides precise control over the chemical composition and thickness of the coating, ensuring consistent quality across the entire surface. However, uneven evaporation and ejection of molten metal droplets from the cathode during cathode arc deposition produce particles and droplets, resulting in an uneven coating surface. This study presents a new design for a magnetically controlled cathode arc source to effectively reduce particles and droplets during the cathodic arc deposition of multi-component alloy targets for nitride-based hard coatings. The study compares the performance of a new source with a conventional magnetic-controlled arc source for depositing TiAlNbSiN and AlCrSiN films. In the conventional source, the magnetic field is generated by a permanent magnet (PM), whereas in the new source, it is generated and controlled using an electromagnet (EM). Both films are produced using multi-component alloy targets (TiAlNbSi and AlCrSi) with identical composition ratios. The plasma characteristics of the two different arc sources are investigated using an optical emission spectrometer (OES), and the surface morphology, structural characteristics, deposition rate, uniformity, and surface roughness (Sa) are examined using scanning electron microscopy (SEM). When the EM was applied to have high plasma density, the hardness of the TiAlNbSiN film deposited with the novel arc source measured 31.2 ± 1.9 GPa, which is higher than that of the PM arc source (28.3 ± 1.4 GPa). In contrast, the AlCrSiN film created using a typical arc source exhibited a hardness of only 25.5 ± 0.6 GPa. This lower hardness may be due to insufficient ion kinetic energy to enhance stress blocking and increase hardness, or the presence of the h-AlN phase in the film, which was not detected by XRD. The electromagnet arc source, with its adequate ion bombardment velocity, facilitated a complementary effect between grain growth and stress blocking, leading to a remarkable hardness of 32.6 ± 0.5 GPa.


  • Open Access

    Improvement of Tribological Performance of TiAlNbN Hard Coatings by Adding AlCrN

    by Yin-Yu Chang, Kai-Chun Huang

    In tribological applications, the degradation of alloy nitride coatings is an issue of increasing concern. The drawbacks of monolayer hard coatings can be overcome using a multilayer coating system. In this study, single-layer TiAlNbN and multilayer TiAlNbN/AlCrN coatings with AlCrN layer addition into TiAlNbN were prepared by cathodic arc evaporation (CAE). The multilayer TiAlNbN/AlCrN showed B1 NaCl structure, and the columnar structure continued from the bottom interlayer of CrN to the top multilayers without interruption. After AlCrN addition, the TiAlNbN/AlCrN coating consisted of TiAlNbN and AlCrN multilayers with a periodic thickness of 13.2 nm. The layer thicknesses of the TiAlNbN and AlCrN were 7 nm and 6.2 nm, respectively. The template growth of the TiAlNbN and AlCrN sublayers stabilized the cubic phases. The introduction of bottom CrN and the TiAlNbN/CrN transition layers possessed com-position-gradient that improved the adhesion strength of the coatings. The hardness of the deposited TiAlNbN was 30.2 ± 1.3 GPa. The TiAlNbN/AlCrN had higher hardness of 31.7 ± 3.5 GPa and improved tribological performance (wear rate = 8.2 ± 0.6 × 10−7 mm3/Nm) than those of TiAlNbN, which were because the multilayer architecture with AlCrN addition effectively resisted abrasion wear.


  • Open Access

    Biocompatibility and Microstructure-Based Stress Analyses of TiNbZrTa Composite Films

    by Bo-Wei Lai, Yin-Yu Chang, Tzong-Ming Shieh, Heng-Li Huang

    Background: the clinical application of orthopedic or dental implants improves the quality of the lives of patients. However, the long-term use of implants may lead to implant loosening and related complications. The purpose of this study is to deposit titanium (Ti)-niobium (Nb)-zirconium (Zr)-tantalum (Ta) alloys on the surface of Ti-6Al-4V to increase structural strength and biocompatibility for the possible future application of implants. Materials and methods: Ti, Nb, Zr, and Ta served as the materials for the surface modification of the titanium alloy. TiNbZr and TiNbZrTa coatings were produced using cathodic arc evaporation, and a small amount of nitrogen was added to produce TiNbZrTa(N) film. Annealing and oxidation were then conducted to produce TiNbZrTa-O and TiNbZrTa(N)-O coatings. In this study, biological tests and finite element analyses of those five alloy films, as well as uncoated Ti-6Al-4V, were performed. Human osteosarcoma cells (MG-63) and mouse fibroblast cells (L-929) were used to analyze cytotoxicity, cell viability, and cell morphology, and the bone differentiation of MG-63 was evaluated in an alkaline phosphatase experiment. Furthermore, for measuring the gene expression level of L-929, reverse transcription quantitative real-time polymerase chain reaction (RT-qPCR) was conducted. The three-dimensional (3D) computational models of the coated and uncoated sample films were constructed using images of transmission electron microscopy and computer-aided design software and, then, the stress distributions of all models were evaluated by finite element analysis. Result: the cytotoxicity test revealed that the surface treatment had no significant cytotoxic effects on MG-63 and L-929 cells. According to the results of the cell viability of L-929, more cell activity was observed in the surface-treated experimental group than in the control group; for MG-63, the cell viability of the coated samples was similar to that of the uncoated samples. In the cell morphology analysis, both MG-63 and L-929 exhibited attached filopodia and lamellipodia, verifying that the cells were well attached. The alkaline phosphatase experiment demonstrated that the surface treatment did not affect the characteristics of early osteogenic differentiation, whereas RT-qPCR analysis showed that surface treatment can promote better performance of L-929 cells in collagen, type I, α1, and fibronectin 1. Finally, the results of the finite element analysis revealed that the coated TiNb interlayer can effectively reduce the stress concentration inside the layered coatings. Conclusions: TiNbZrTa series films deposited using cathodic arc evaporation had excellent biocompatibility with titanium alloys, particularly in regard to soft tissue cells, which exhibited an active performance. The finite element analysis verified that the TiNb interlayer can reduce the stress concentration inside TiNbZrTa series films, increasing their suitability for application in biomedical implants in the future.


  • Open Access

    Tribological and Mechanical Properties of Multicomponent CrVTiNbZr(N) Coatings

    by Yin-Yu Chang, Cheng-Hsi Chung

    Multi-element material coating systems have received much attention for improving the mechanical performance in industry. However, they are still focused on ternary systems and seldom beyond quaternary ones. High entropy alloy (HEA) bulk material and thin films are systems that are each comprised of at least five principal metal elements in equally matched proportions, and some of them are found possessing much higher strength than traditional alloys. In this study, CrVTiNbZr high entropy alloy and nitrogen contained CrVTiNbZr(N) nitride coatings were synthesized using high ionization cathodic-arc deposition. A chromium-vanadium alloy target, a titanium-niobium alloy target and a pure zirconium target were used for the deposition. By controlling the nitrogen content and cathode current, the CrNbTiVZr(N) coating with gradient or multilayered composition control possessed different microstructures and mechanical properties. The effect of the nitrogen content on the chemical composition, microstructure and mechanical properties of the CrVTiNbZr(N) coatings was investigated. Compact columnar microstructure was obtained for the synthesized CrVTiNbZr(N) coatings. The CrVTiNbZrN coating (HEAN-N165), which was deposited with nitrogen flow rate of 165 standard cubic centimeters per minute (sccm), exhibited slightly blurred columnar and multilayered structures containing CrVN, TiNbN and ZrN. The design of multilayered CrVTiNbZrN coatings showed good adhesion strength. Improvement of adhesion strength was obtained with composition-gradient interlayers. The CrVTiNbZrN coating with nitrogen content higher than 50 at.% possessed the highest hardness (25.2 GPa) and the resistance to plastic deformation H3/E*2 (0.2 GPa) value, and therefore the lowest wear rate was obtained because of high abrasion wear resistance.


  • Open Access

    Deposition of Multicomponent AlTiCrMoN Protective Coatings for Metal Cutting Applications

    by Yin-Yu Chang, Chih-Cheng Chuang

    The high potential of the protective coatings for metal machining applications using the physical vapor deposition (PVD) processes is one to be valued, and will accelerate development of the multicomponent coating design and increase the cutting efficiency. In this study, nanostructured AlTiCrMoN coatings in a multilayered structure were fabricated using cathodic-arc deposition (CAD). Controlling the cathode current of both CrMo and AlTi alloy targets in a nitrogen environment, multilayered AlTiN/CrMoN coatings were deposited. The AlTiN and AlTiN/CrMoN multilayered coatings exhibit a face-centered cubic (fcc) structure with columnar morphologies. The highest hardness of 35.6 ± 1.5 GPa was obtained for the AlTiN coating; however, the H3/E*2 and H/E* values were the lowest (0.124 and 0.059, respectively). The multilayered AlTiN/CrMoN coatings possessed higher H3/E*2 and H/E* values of up to 0.157 and 0.071, respectively. The present study investigated the cutting performance of end mills in the milling of SUS316L stainless steel. The cutting performance was evaluated in terms of cutting length and tool wear. Because of high resistance to adhesive and abrasive wear, the end mills coated with multilayered AlTiN/CrMoN showed less flank wear than monolithic AlTiN. The introduction of CrMoN sublayers improved the cutting tool life of AlTiN.


  • Open Access

    Fabrication of a Novel Ta(Zn)O Thin Film on Titanium by Magnetron Sputtering and Plasma Electrolytic Oxidation for Cell Biocompatibilities and Antibacterial Applications

    by Heng-Li Huang, Ming-Tzu Tsai, Yin-Yu Chang, Yi-Jyun Lin, Jui-Ting Hsu

    Pure titanium (Ti) and titanium alloys are widely used as artificial implant materials for biomedical applications. The excellent biocompatibility of Ti has been attributed to the presence of a natural or artificial surface layer of titanium dioxide. Zinc oxide and tantalum oxide thin films are recognized due to their outstanding antibacterial properties. In this study, high power impulse magnetron sputtering (HiPIMS) was used for the deposition of tantalum oxide and zinc-doped Ta(Zn)O thin films on Ti with rough and porous surface, which was pretreated by plasma electrolytic oxidation (PEO). Surface morphology, antibacterial property as well as cell biocompatibility were analyzed. The antibacterial effect was studied individually for the Gram-positive and Gram-negative bacteria Staphylococcus aureus (S. aureus) and Actinobacillus actinomycetemcomitans (A. actinomycetemcomitans). The deposited Ta (Zn)O coating was composed of amorphous tantalum oxide and crystalline ZnO. The antibacterial results on the tantalum oxide and Ta(Zn)O coated Ti indicated a significant inhibition of both S. aureus and A. actinomycetemcomitans bacteria when compared with the uncoated Ti samples. The deposited Ta(Zn)O showed the best antibacterial performance. The Ta(Zn)O coated Ti showed lower level of the cell viability in MG-63 cells compared to other groups, indicating that Zn-doped Ta(Zn)O coatings may restrict the cell viability of hard tissue-derived MG-63 cells. However, the biocompatibility tests demonstrated that the tantalum oxide and Ta(Zn)O coatings improved cell attachment and cell growth in human skin fibroblasts. The cytotoxicity was found similar between the Ta2O5 and Ta(Zn)O coated Ti. By adopting a first PEO surface modification and a subsequent HiPIMS coating deposition, we synthetized amorphous tantalum oxide and Ta(Zn)O coatings that improved titanium surface properties and morphologies, making them a good surface treatment for titanium-based implants.


  • Open Access

    Effect of Plasma Nitriding Pretreatment on the Mechanical Properties of AlCrSiN-Coated Tool Steels

    by Yin-Yu Chang, Siddhant Amrutwar

    Surface modification of steel has been reported to improve hardness and other mechanical properties, such as increase in resistance, for reducing plastic deformation, fatigue, and wear. Duplex surface treatment, such as a combination of plasma nitriding and physical vapor deposition, achieves superior mechanical properties and resistance to wear. In this study, the plasma nitriding process was conducted prior to the deposition of hard coatings on the SKH9 substrate. This process was done by a proper mixture of nitrogen/hydrogen gas at suitable duty cycle, pressure, and voltage with proper temperature. Later on, the deposition of gradient AlCrSiN coatings synthesized by a cathodic-arc deposition process was performed. During the deposition of AlCrSiN, CrN, AlCrN/CrN, and AlCrSiN/AlCrN were deposited as gradient interlayers to improve adhesion between the coatings and nitrided steels. A repetitive impact test (200k–400k times) was performed at room temperature and at high temperature (~500 °C) to assess impact resistance. The results showed that the tribological impact resistance for the synthesized AlCrSiN increased because of a progressive hardness support. The combination of plasma nitriding and AlCrSiN hard coatings is capable of increasing the life of molding dies and metal forging dies in mass production.


  • Open Access

    Effects of Laser Texture Oxidation and High-Temperature Annealing of TiV Alloy Thin Films on Mechanical and Antibacterial Properties and Cytotoxicity

    by Yin-Yu Chang, Jia-Hao Zhang, Heng-Li Huang

    Titanium dioxide and vanadium oxides have been applied extensively in industrial and medical fields. The objective of this study was to develop various composite structures of titanium and vanadium oxide (Ti-V-O) coatings on pure titanium through high-temperature annealing and laser texturing oxidation, separately; additionally, surface morphologies, tribological and hydrophilic properties, and antibacterial and biocompatibility abilities of these Ti-V-O coatings were evaluated. TiV alloy thin films were deposited on pure titanium and then annealed to form Ti-V-O coatings through thermal oxidation and laser texturing oxidation. Ball-on-disc wear tests and contact angle tests were conducted to evaluate the tribological properties and wettability of the coatings, respectively. The antibacterial activity of the coatings was estimated by SYTO9 nucleic acid staining with Staphylococcus aureus (Gram-positive bacteria). The cell cytotoxicity of the coatings was analyzed following the ISO 10995-5:2009 standard with human skin fibroblast cells. The Ti-V-O coatings, subjected to annealing at 700 °C, demonstrated higher hardness (Hv 1171) and a lower friction coefficient (0.6). The highest hardness (Hv 2711) and the lowest friction coefficient (0.52) were obtained for the Ti-V-O after laser surface texturing oxidation at 100 kHz. The oxide coating obtained from 100 kHz laser texturing oxidation exhibited the lotus effect because of its systematic textured microstructures, and displayed superhydrophobic surface properties. Compared with the unannealed TiV coating, both the samples with high-temperature annealing and laser surface texturing oxidation had excellent antibacterial properties to Staphylococcus aureus. However, the Ti-V-O thin films exhibited notable cell cytotoxicity. Although the cell viability on Ti-V-O coatings were not ideal, this study confirmed improvement in surface hardness, tribology, and antibacterial performance in Ti-V-O coatings, which may have potential for use in biomedical tools, devices, and equipment.