Francesca Martelletto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Francesca Martelletto has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Luca Doretti
4 shared publicationsSimone Mancin
University of Padova
2 shared publications- Simone Mancin
Department of Management and Engineering, University of Padova, 36100 Vicenza, Italy
2 shared publications Antonio Galgaro
1 shared publicationClaudio Zilio
University of Padova
1 shared publication- Claudio Zilio
University of Padova
1 shared publication
Latest Publications
- Open Access
- 6 January 2026
- Published by Elsevier in Energy Reports
- Vol. 15
Integrated optimization of fin geometry and nanoparticle-enhanced PCMs in shell-and-tube thermal storage systems: A CFD–ML framework
- 6 January 2026
- Published by Elsevier in Energy Reports
- Vol. 15
Open AccessIntegrated optimization of fin geometry and nanoparticle-enhanced PCMs in shell-and-tube thermal storage systems: A CFD–ML framework
- 23 November 2025
- Published by Springer Nature
- p. 264-273
Numerical Analysis of Concrete Thermal Storage with PCMs for Underground Application Integrated with Heat Pump
- 23 November 2025
- Published by Springer Nature
- p. 264-273
Numerical Analysis of Concrete Thermal Storage with PCMs for Underground Application Integrated with Heat Pump
- Open Access
A Comparative Experimental Analysis of a Cold Latent Thermal Storage System Coupled with a Heat Pump/Air Conditioning Unit
The decarbonization of residential cooling systems requires innovative solutions to overcome the mismatch between the renewable energy availability and demand. Integrating latent thermal energy storage (LTES) with heat pump/air conditioning (HP/AC) units can help balance energy use and enhance efficiency. However, the dynamic behavior of such integrated systems, particularly under low-load conditions, remains underexplored. This study investigates a 5 kW HP/AC unit coupled with an 18 kWh LTES system using a bio-based Phase Change Material (PCM) with a melting temperature of 9 °C. Two configurations were tested: charging the LTES using either a thermostatic bath or the HP/AC unit. Key parameters such as the stored energy, temperature distribution, and cooling capacity were analyzed. The results show that, under identical conditions (2 °C inlet temperature, 16 L/min flow rate), the energy stored using the HP/AC unit was only 6.3% lower than with the thermostatic bath. Nevertheless, significant cooling capacity fluctuations occurred with the HP/AC unit due to compressor modulation and anti-frost cycles. The compressor frequency varied from 75 Hz to 25 Hz, and inefficient on-off cycling appeared in the final phase, when the power demand dropped below 1 kW. These findings highlight the importance of integrated system design and control strategies. A co-optimized HP/AC–LTES setup is essential to avoid performance degradation and to fully exploit the benefits of thermal storage in residential cooling.
Open AccessA Comparative Experimental Analysis of a Cold Latent Thermal Storage System Coupled with a Heat Pump/Air Conditioning Unit
The decarbonization of residential cooling systems requires innovative solutions to overcome the mismatch between the renewable energy availability and demand. Integrating latent thermal energy storage (LTES) with heat pump/air conditioning (HP/AC) units can help balance energy use and enhance efficiency. However, the dynamic behavior of such integrated systems, particularly under low-load conditions, remains underexplored. This study investigates a 5 kW HP/AC unit coupled with an 18 kWh LTES system using a bio-based Phase Change Material (PCM) with a melting temperature of 9 °C. Two configurations were tested: charging the LTES using either a thermostatic bath or the HP/AC unit. Key parameters such as the stored energy, temperature distribution, and cooling capacity were analyzed. The results show that, under identical conditions (2 °C inlet temperature, 16 L/min flow rate), the energy stored using the HP/AC unit was only 6.3% lower than with the thermostatic bath. Nevertheless, significant cooling capacity fluctuations occurred with the HP/AC unit due to compressor modulation and anti-frost cycles. The compressor frequency varied from 75 Hz to 25 Hz, and inefficient on-off cycling appeared in the final phase, when the power demand dropped below 1 kW. These findings highlight the importance of integrated system design and control strategies. A co-optimized HP/AC–LTES setup is essential to avoid performance degradation and to fully exploit the benefits of thermal storage in residential cooling.
- 7 May 2024
- Published by Springer Nature
- p. 362-370
A Bioinspired Geometric Modeling Approach Based on Curve Differential Growth
- 7 May 2024
- Published by Springer Nature
- p. 362-370
A Bioinspired Geometric Modeling Approach Based on Curve Differential Growth
- Open Access
- 1 December 2020
- Published by Elsevier in Energy Reports
- Vol. 6, 199-214
Numerical analyses of concrete thermal energy storage systems: effect of the modules’ arrangement
- 1 December 2020
- Published by Elsevier in Energy Reports
- Vol. 6, 199-214
Open AccessNumerical analyses of concrete thermal energy storage systems: effect of the modules’ arrangement
- 1 April 2019
- Published by Elsevier in Journal of Energy Storage
- Vol. 22, 68-79
A simplified analytical approach for concrete sensible thermal energy storages simulation
- 1 April 2019
- Published by Elsevier in Journal of Energy Storage
- Vol. 22, 68-79
A simplified analytical approach for concrete sensible thermal energy storages simulation