JTJames Eric Thornton

James Eric Thornton

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


James Eric Thornton has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Identification and quantitation of clinically relevant microbes in patient samples: Comparison of three k-mer based classifiers for speed, accuracy, and sensitivity

    by George S Watts, James E Thornton, Ken Youens-Clark, Alise J Ponsero, Marvin J Slepian, Emmanuel Menashi, Charles Hu, Wuquan Deng, David G Armstrong, Spenser Reed, et al.

    Infections are a serious health concern worldwide, particularly in vulnerable populations such as the immunocompromised, elderly, and young. Advances in metagenomic sequencing availability, speed, and decreased cost offer the opportunity to supplement or even replace culture-based identification of pathogens with DNA sequence-based diagnostics. Adopting metagenomic analysis for clinical use requires that all aspects of the workflow are optimized and tested, including data analysis and computational time and resources. We tested the accuracy, sensitivity, and resource requirements of three top metagenomic taxonomic classifiers that use fast k-mer based algorithms: Centrifuge, CLARK, and KrakenUniq. Binary mixtures of bacteria showed all three reliably identified organisms down to 1% relative abundance, while only the relative abundance estimates of Centrifuge and CLARK were accurate. All three classifiers identified the organisms present in their default databases from a mock bacterial community of 20 organisms, but only Centrifuge had no false positives. In addition, Centrifuge required far less computational resources and time for analysis. Centrifuge analysis of metagenomes obtained from samples of VAP, infected DFUs, and FN showed Centrifuge identified pathogenic bacteria and one virus that were corroborated by culture or a clinical PCR assay. Importantly, in both diabetic foot ulcer patients, metagenomic sequencing identified pathogens 4–6 weeks before culture. Finally, we show that Centrifuge results were minimally affected by elimination of time-consuming read quality control and host screening steps. Currently, the gold standard for identifying pathogens that are causing infection is to attempt growth in culture followed by identification based on physical characteristics such as shape and metabolic profile. However, many organisms do not grow in culture or are overgrown by faster growing organisms that out-compete them. Another method to identify pathogens in infections is to sequence the DNA in the samples and use that DNA sequence to identify the pathogens present—a process called metagenomic sequencing. Analyzing clinical metagenomic data can be difficult given the amount of data generated, high levels of human DNA contamination and a lack of well-defined bioinformatics methods. In this study, three leading software tools were compared for identification and quantitation of microbes in metagenomic data. One tool, called Centrifuge, reliably identified microbes present at just 1% relative abundance while requiring less computer time and resources than the others to which it was compared. Moreover, we found that Centrifuge results changed minimally when time-consuming quality control and host-screening steps were eliminated. We also examined Centrifuge’s performance in real-word clinical data sets showing that Centrifuge identified the same pathogens as culture.


  • Open Access

    Speed, accuracy, sensitivity and quality control choices for detecting clinically relevant microbes in whole blood from patients

    by James Eric Thornton, George S. Watts, Kenneth Youens-Clark, Lee D. Cranmer, Bonnie L. Hurwitz

    Infections are a serious health concern worldwide, particularly in vulnerable populations such as the immunocompromised, elderly, and young. Advances in metagenomic sequencing availability, speed, and decreased cost offer the opportunity to supplement or replace culture-based identification of pathogens with DNA sequence-based diagnostics. Adopting metagenomic analysis for clinical use requires that all aspects of the pipeline are optimized and tested, including data analysis. We tested the accuracy, sensitivity, and resource requirements of Centrifuge within the context of clinically relevant bacteria. Binary mixtures of bacteria showed Centrifuge reliably identified organisms down to 0.1% relative abundance. A staggered mock bacterial community showed Centrifuge outperformed CLARK while requiring less computing resources. Shotgun metagenomes obtained from whole blood in three febrile neutropenia patients showed Centrifuge could identify both bacteria and viruses as part of a culture-free workflow. Finally, Centrifuge results changed minimally by eliminating time-consuming read quality control and host screening steps. AUTHOR SUMMARY: Immunocompromised patients, such as those with febrile neutropenia (FN), are susceptible to infections, yet cultures fail to identify causative organisms ~80% of the time. High-throughput metagenomic sequencing offers a promising approach for identifying pathogens in clinical samples. Mining through metagenomes can be difficult given the volume of reads, overwhelming human contamination, and lack of well-defined bioinformatics methods. The goal of our study was to assess Centrifuge, a leading tool for the identification and quantitation of microbes, and provide a streamlined bioinformatics workflow real-word data from FN patient blood samples. To ensure the accuracy of the workflow we carefully examined each step using known bacterial mixtures that varied by genetic distance and abundance. We show that Centrifuge reliably identifies microbes present at just 1% relative abundance and requires substantially less computer time and resource than CLARK. Moreover, we found that Centrifuge results changed minimally by quality control and host-screening allowing for further reduction in compute time. Next, we leveraged Centrifuge to identify viruses and bacteria in blood draws for three FN patients, and confirmed suspected pathogens using genome coverage plots. We developed a web-based tool in iMicrobe and detailed protocols to promote re-use.

  • Open Access

    Speed, accuracy, sensitivity and quality control choices for detecting clinically relevant microbes in whole blood from patients v1

    by James E Thornton Jr, George Watts, Ken Youens-Clark, Lee Crammer, Bonnie L Hurwitz

    Infections are a serious health concern worldwide, particularly in vulnerable populations such as the immunocompromised, elderly, and young. Advances in metagenomic sequencing availability, speed, and decreased cost offer the opportunity to supplement or replace culture-based identification of pathogens with DNA sequence-based diagnostics. For metagenomic analysis to be adopted for clinical use, all aspects of the pipeline should be optimized and tested, including data analysis. The accuracy, sensitivity, and resource requirements of Centrifuge were tested within the context of clinically relevant bacteria. Binary mixtures of bacteria showedCentrifuge reliably identified organisms down to 0.1% relative abundance. A staggered mock bacterial community showed Centrifuge outperformed CLARK while requiring less computing resources. Shotgun metagenomes obtained from whole blood in three febrile neutropenia patients showed Centrifuge can identify both bacteria and viruses as part of a culture-free workflow.