Ayub Valadbeigi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ayub Valadbeigi has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Bahram Jalaei
Iran Univ Med Sci, Sch Rehabil Sci, Dept Audiol, Tehran, Iran
2 shared publications- Bahram Jalaei
Department of Audiology, Rehabilitation Research Center, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran
1 shared publication Farnoush Jarollahi
Iran Univ Med Sci, Sch Rehabil Sci, Dept Audiol, Tehran, Iran
1 shared publication- Farnoush Jarollahi
Rehabilitation Research Center, Department of Audiology, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran
1 shared publication Hamid Haghani
Iran Univ Med Sci, Sch Publ Hlth, Dept Biostat, Tehran, Iran
1 shared publication- Hamid Haghani
Department of Biostatistics, School of Public Health, Iran University of Medical Sciences, Tehran, Iran
1 shared publication
Latest Publications
- Open Access
- 1 January 2022
- Published by Maad Rayan Publishing Company
- Vol. 16 (2) , 93-105
Comparing Sound-Field Speech-Auditory Brainstem Response Components between Cochlear Implant Users with Different Speech Recognition in Noise Scores
Objectives Many studies have suggested that cochlear implant (CI) users vary in terms of speech recognition in noise. Studies in this field attribute this variety partly to subcortical auditory processing. Studying speech-Auditory Brainstem Response (speech-ABR) provides good information about speech processing; thus, this work was designed to compare speech-ABR components between two groups of CI users with good and poor speech recognition in noise scores. Materials & Methods The present study was conducted on two groups of CI users aged 8-10 years old. The first group (CI-good) consisted of 15 children with prelingual CI who had good speech recognition in noise performance. The second group (CI-poor) was matched with the first group, but they had poor speech recognition in noise performance. The speech-ABR test in a sound-field presentation was performed for all the participants. Results The speech-ABR response showed more delay in C, D, E, F, O latencies in CI-poor than CI-good users (P <0.05), meanwhile no significant difference was observed in initial wave (V(t= -0.293, p= 0.771 and A (t= -1.051, p= 0.307). Analysis in spectral-domain showed a weaker representation of fundamental frequency as well as the first formant and high-frequency component of speech stimuli in the CI users with poor auditory performance. Conclusion Results revealed that CI users who showed poor auditory performance in noise performance had deficits in encoding the periodic portion of speech signals at the brainstem level. Also, this study could be as physiological evidence for poorer pitch processing in CI users with poor speech recognition in noise performance.
- 1 January 2022
- Published by Maad Rayan Publishing Company
- Vol. 16 (2) , 93-105
Open AccessComparing Sound-Field Speech-Auditory Brainstem Response Components between Cochlear Implant Users with Different Speech Recognition in Noise Scores
Objectives Many studies have suggested that cochlear implant (CI) users vary in terms of speech recognition in noise. Studies in this field attribute this variety partly to subcortical auditory processing. Studying speech-Auditory Brainstem Response (speech-ABR) provides good information about speech processing; thus, this work was designed to compare speech-ABR components between two groups of CI users with good and poor speech recognition in noise scores. Materials & Methods The present study was conducted on two groups of CI users aged 8-10 years old. The first group (CI-good) consisted of 15 children with prelingual CI who had good speech recognition in noise performance. The second group (CI-poor) was matched with the first group, but they had poor speech recognition in noise performance. The speech-ABR test in a sound-field presentation was performed for all the participants. Results The speech-ABR response showed more delay in C, D, E, F, O latencies in CI-poor than CI-good users (P <0.05), meanwhile no significant difference was observed in initial wave (V(t= -0.293, p= 0.771 and A (t= -1.051, p= 0.307). Analysis in spectral-domain showed a weaker representation of fundamental frequency as well as the first formant and high-frequency component of speech stimuli in the CI users with poor auditory performance. Conclusion Results revealed that CI users who showed poor auditory performance in noise performance had deficits in encoding the periodic portion of speech signals at the brainstem level. Also, this study could be as physiological evidence for poorer pitch processing in CI users with poor speech recognition in noise performance.
- Open Access
- 10 April 2020
- Published by The Korean Audiological Society in Journal of Audiology and Otology
- Vol. 24 (2) , 71-78
Sound-Field Speech Evoked Auditory Brainstem Response in Cochlear-Implant Recipients
Background and Objectives: Currently limited information is available on speech stimuli processing at the subcortical level in the recipients of cochlear implant (CI). Speech processing in the brainstem level is measured using speech-auditory brainstem response (S-ABR). The purpose of the present study was to measure the S-ABR components in the sound-field presentation in CI recipients, and compare with normal hearing (NH) children.Subjects and Methods: In this descriptive-analytical study, participants were divided in two groups: patients with CIs; and NH group. The CI group consisted of 20 prelingual hearing impairment children (mean age=8.90 ± 0.79 years), with ipsilateral CIs (right side). The control group consisted of 20 healthy NH children, with comparable age and sex distribution. The S-ABR was evoked by the 40-ms synthesized /da/ syllable stimulus that was indicated in the sound-field presentation.Results: Sound-field S-ABR measured in the CI recipients indicated statistically significant delayed latencies, than in the NH group. In addition, these results demonstrated that the frequency following response peak amplitude was significantly higher in CI recipients, than in the NH counterparts (p<0.05). Finally, the neural phase locking were significantly lower in CI recipients (p<0.05). Conclusions: The findings of sound-field S-ABR demonstrated that CI recipients have neural encoding deficits in temporal and spectral domains at the brainstem level; therefore, the sound-field S-ABR can be considered an efficient clinical procedure to assess the speech process in CI recipients.
- 10 April 2020
- Published by The Korean Audiological Society in Journal of Audiology and Otology
- Vol. 24 (2) , 71-78
Open AccessSound-Field Speech Evoked Auditory Brainstem Response in Cochlear-Implant Recipients
Background and Objectives: Currently limited information is available on speech stimuli processing at the subcortical level in the recipients of cochlear implant (CI). Speech processing in the brainstem level is measured using speech-auditory brainstem response (S-ABR). The purpose of the present study was to measure the S-ABR components in the sound-field presentation in CI recipients, and compare with normal hearing (NH) children.Subjects and Methods: In this descriptive-analytical study, participants were divided in two groups: patients with CIs; and NH group. The CI group consisted of 20 prelingual hearing impairment children (mean age=8.90 ± 0.79 years), with ipsilateral CIs (right side). The control group consisted of 20 healthy NH children, with comparable age and sex distribution. The S-ABR was evoked by the 40-ms synthesized /da/ syllable stimulus that was indicated in the sound-field presentation.Results: Sound-field S-ABR measured in the CI recipients indicated statistically significant delayed latencies, than in the NH group. In addition, these results demonstrated that the frequency following response peak amplitude was significantly higher in CI recipients, than in the NH counterparts (p<0.05). Finally, the neural phase locking were significantly lower in CI recipients (p<0.05). Conclusions: The findings of sound-field S-ABR demonstrated that CI recipients have neural encoding deficits in temporal and spectral domains at the brainstem level; therefore, the sound-field S-ABR can be considered an efficient clinical procedure to assess the speech process in CI recipients.
- Open Access
- 10 April 2019
- Published by The Korean Audiological Society in Journal of Audiology and Otology
- Vol. 23 (2) , 83-88
Central Auditory Processing Tests as Diagnostic Tools for the Early Identification of Elderly Individuals with Mild Cognitive Impairment
Mild cognitive impairment (MCI) is a disorder that usually occurs in the elderly, leading to dementia in some progressive cases. The purpose of this study is to examine the utility of central auditory processing tests as early diagnostic tools for identifying the elderly with MCI. This study was conducted on 20 elderly patients with MCI and 20 healthy matched peers. The speech perception ability in a quiet environment and in the presence of background noise and also temporal resolution were assessed by using Speech Perception in Noise (SPIN) and Gap in Noise (GIN) tests, respectively. The results indicated that the ability to understand speech in a quiet environment did not differ significantly between the two groups. However, SPIN at the three signal-tonoise ratios and the temporal resolution scores were significantly different between the two groups (p<0.001). Individuals with MCI appear to have poorer speech comprehension in noise and a lower temporal resolution than those of the same age, but without cognitive defects. Considering the utility of these tests in identifying cognitive problems, we propose that since the GIN test seems to be less influenced by intervening factors, this test can therefore, be a useful tool for the early screening of elderly people with cognitive problems.
- 10 April 2019
- Published by The Korean Audiological Society in Journal of Audiology and Otology
- Vol. 23 (2) , 83-88
Open AccessCentral Auditory Processing Tests as Diagnostic Tools for the Early Identification of Elderly Individuals with Mild Cognitive Impairment
Mild cognitive impairment (MCI) is a disorder that usually occurs in the elderly, leading to dementia in some progressive cases. The purpose of this study is to examine the utility of central auditory processing tests as early diagnostic tools for identifying the elderly with MCI. This study was conducted on 20 elderly patients with MCI and 20 healthy matched peers. The speech perception ability in a quiet environment and in the presence of background noise and also temporal resolution were assessed by using Speech Perception in Noise (SPIN) and Gap in Noise (GIN) tests, respectively. The results indicated that the ability to understand speech in a quiet environment did not differ significantly between the two groups. However, SPIN at the three signal-tonoise ratios and the temporal resolution scores were significantly different between the two groups (p<0.001). Individuals with MCI appear to have poorer speech comprehension in noise and a lower temporal resolution than those of the same age, but without cognitive defects. Considering the utility of these tests in identifying cognitive problems, we propose that since the GIN test seems to be less influenced by intervening factors, this test can therefore, be a useful tool for the early screening of elderly people with cognitive problems.