Cara M. Nunez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Cara M. Nunez has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Allison M. Okamura
Department of Mechanical Engineering, Stanford University, Stanford, CA, USA
10 shared publications - Kyle T. Yoshida
Department of Mechanical and Aerospace Engineering, University of California, Los Angeles, CA, USA
6 shared publications - Heather Culbertson
University of Southern California, USA
4 shared publications - Rachel A. G. Adenekan
Department of Mechanical Engineering, Stanford University, Stanford, CA, USA
4 shared publications Allison M. Okamura
Stanford University,Department of Mechanical Engineering,Stanford,CA,94305
3 shared publications- Alexis J. Lowber
Mechanical Engineering Department, Stanford University, Stanford, CA, USA
2 shared publications
Latest Publications
- 1 April 2026
- Published by SAGE Publications in Journal of Diabetes Science and Technology
Smartphone-based App to Assess Diabetic Peripheral Neuropathy
Background: Diabetic peripheral neuropathy (DPN) affects approximately 50% of individuals with diabetes and is a risk factor for amputations. Unfortunately, foot exams and screening tools are inconsistent and miss early-stage nerve damage. A smartphone-based application that delivers controlled vibrations, records patient responses, and computes a vibration perception threshold (SVPT) may present an accessible, precise monitoring avenue. This study assesses the clinical relevance and precision of SVPTs for measuring large-fiber sensory deficits in patients with diabetes. Methods: We measured SVPTs in 71 patients with pre-diabetes or diabetes and compared their efficacy with tuning fork exams. We analyzed the correlation between SVPT and Rydel-Seiffer tuning fork (RSTF) scores, along with their relationship with clinical DPN markers such as hemoglobin A1c (HbA1c), age, and disease duration using multivariable linear regression. Results: The SVPTs moderately correlated with RSTF scores ( R s = −0.43, p = 0.0019). Among adults aged 50 to 69 years, SVPTs correlated significantly with clinical markers [ F (4, 29) = 4.76, p = 0.00447, Multiple R 2 = 0.396, Adjusted R 2 = 0.313, ϵ = 0.167]. The interaction between age and HbA1c was positively associated with SVPTs (β = 0.118, p = 0.001), while SVPTs were negatively associated with diabetes duration (β = −0.098, p = 0.003). Conclusions: We present a clinically relevant, patient-operated smartphone application for large-fiber sensory monitoring, tested on patients with varying DPN risk. This novel platform has the potential to provide a precise, reliable, and accessible avenue for identifying individuals at risk of developing DPN complications, prior to overt clinical manifestation.
- 1 April 2026
- Published by SAGE Publications in Journal of Diabetes Science and Technology
Smartphone-based App to Assess Diabetic Peripheral Neuropathy
Background: Diabetic peripheral neuropathy (DPN) affects approximately 50% of individuals with diabetes and is a risk factor for amputations. Unfortunately, foot exams and screening tools are inconsistent and miss early-stage nerve damage. A smartphone-based application that delivers controlled vibrations, records patient responses, and computes a vibration perception threshold (SVPT) may present an accessible, precise monitoring avenue. This study assesses the clinical relevance and precision of SVPTs for measuring large-fiber sensory deficits in patients with diabetes. Methods: We measured SVPTs in 71 patients with pre-diabetes or diabetes and compared their efficacy with tuning fork exams. We analyzed the correlation between SVPT and Rydel-Seiffer tuning fork (RSTF) scores, along with their relationship with clinical DPN markers such as hemoglobin A1c (HbA1c), age, and disease duration using multivariable linear regression. Results: The SVPTs moderately correlated with RSTF scores ( R s = −0.43, p = 0.0019). Among adults aged 50 to 69 years, SVPTs correlated significantly with clinical markers [ F (4, 29) = 4.76, p = 0.00447, Multiple R 2 = 0.396, Adjusted R 2 = 0.313, ϵ = 0.167]. The interaction between age and HbA1c was positively associated with SVPTs (β = 0.118, p = 0.001), while SVPTs were negatively associated with diabetes duration (β = −0.098, p = 0.003). Conclusions: We present a clinically relevant, patient-operated smartphone application for large-fiber sensory monitoring, tested on patients with varying DPN risk. This novel platform has the potential to provide a precise, reliable, and accessible avenue for identifying individuals at risk of developing DPN complications, prior to overt clinical manifestation.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 18 (4) , 1085-1086
Correction to “Cognitive and Physical Activities Impair Perception of Smartphone Vibrations”
In [1], Figs. 4, 5, 6, and 7 were incorrectly published. Below are the correct figures and their corresponding captions:
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 18 (4) , 1085-1086
Correction to “Cognitive and Physical Activities Impair Perception of Smartphone Vibrations”
In [1], Figs. 4, 5, 6, and 7 were incorrectly published. Below are the correct figures and their corresponding captions:
- Open Access
Smartphone-based App to Assess Diabetic Peripheral Neuropathy
Background: Diabetic peripheral neuropathy (DPN) affects approximately 50% of individuals with diabetes and is a risk factor for amputations. Unfortunately, foot exams and screening tools are inconsistent and miss early-stage nerve damage. A smartphone-based application that delivers controlled vibrations, records patient responses, and computes a vibration perception thresh-old (SVPT) may present an accessible, precise monitoring avenue. This study assesses the clinical relevance and precision of SVPTs for measuring large-fiber sensory deficits in patients with diabetes. Methods: We measured SVPTs in 71 patients with pre-diabetes or diabetes and compared their efficacy with tuning fork exams. We analyzed the correlation between SVPT and Rydel-Seiffer tuning fork (RSTF) scores, along with their relationship with clinical DPN markers such as hemoglobin A1c (HbA1c), age, and disease duration using multivariable linear regression. Results: SVPTs moderately correlated with RSTF scores ( Rs = −0.43, p = 0.0019). Among adults aged 50 to 69, SVPTs correlated significantly with clinical markers ( F (4, 29) = 4.76, p = 0.00447, Multiple R 2 = 0.396, Adjusted R 2 = 0.313, ɛ = 0.167). The interaction between age and HbA1c was positively associated with SVPTs ( β = 0.118, p = 0.001), while SVPTs were negatively associated with diabetes duration ( β = −0.098, p = 0.003). Conclusions: We present a clinically relevant, patient-operated smartphone application for large-fiber sensory monitoring, tested on patients with varying DPN risk. This novel platform has the potential to provide a precise, reliable, and accessible avenue for identifying individuals at risk of developing DPN complications, prior to overt clinical manifestation.
Open AccessSmartphone-based App to Assess Diabetic Peripheral Neuropathy
Background: Diabetic peripheral neuropathy (DPN) affects approximately 50% of individuals with diabetes and is a risk factor for amputations. Unfortunately, foot exams and screening tools are inconsistent and miss early-stage nerve damage. A smartphone-based application that delivers controlled vibrations, records patient responses, and computes a vibration perception thresh-old (SVPT) may present an accessible, precise monitoring avenue. This study assesses the clinical relevance and precision of SVPTs for measuring large-fiber sensory deficits in patients with diabetes. Methods: We measured SVPTs in 71 patients with pre-diabetes or diabetes and compared their efficacy with tuning fork exams. We analyzed the correlation between SVPT and Rydel-Seiffer tuning fork (RSTF) scores, along with their relationship with clinical DPN markers such as hemoglobin A1c (HbA1c), age, and disease duration using multivariable linear regression. Results: SVPTs moderately correlated with RSTF scores ( Rs = −0.43, p = 0.0019). Among adults aged 50 to 69, SVPTs correlated significantly with clinical markers ( F (4, 29) = 4.76, p = 0.00447, Multiple R 2 = 0.396, Adjusted R 2 = 0.313, ɛ = 0.167). The interaction between age and HbA1c was positively associated with SVPTs ( β = 0.118, p = 0.001), while SVPTs were negatively associated with diabetes duration ( β = −0.098, p = 0.003). Conclusions: We present a clinically relevant, patient-operated smartphone application for large-fiber sensory monitoring, tested on patients with varying DPN risk. This novel platform has the potential to provide a precise, reliable, and accessible avenue for identifying individuals at risk of developing DPN complications, prior to overt clinical manifestation.
- 30 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 18 (2) , 423-429
Gamifying Haptics User Studies: Comparison of Response Times From Smartphone Interfaces
Haptics user studies are often restricted to a set, physical location and use methods that do not captivate the user. Applying game design elements can create an entertaining environment and increase user engagement. Using ubiquitous tools, like smartphones, to conduct haptics user studies could allow researchers to access larger participant groups while a gamified approach could facilitate the data collection by making the experiment more enjoyable. To explore this concept, this work presents a gamified version of an existing psychophysical experiment that investigates response time to multisensory cues using a smartphone based on “Whac-A-Mole”. We conducted a user study to compare our gamified interface with an existing psychophysical interface with thirteen participants exploring the response time from eighteen combinations of auditory, haptic, and visual stimuli at different levels of intensities and participant preferences for both interfaces. The results demonstrate that the gamified interface successfully captured similar trends in response times and significantly elevated participant enjoyment ($p$ < 0.003), but did not result in equivalent response times to the original interface. This work shows the benefits and drawbacks of following a gamification approach when designing haptics user studies and discusses factors and trade-offs to consider when gamifying studies.
- 30 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 18 (2) , 423-429
Gamifying Haptics User Studies: Comparison of Response Times From Smartphone Interfaces
Haptics user studies are often restricted to a set, physical location and use methods that do not captivate the user. Applying game design elements can create an entertaining environment and increase user engagement. Using ubiquitous tools, like smartphones, to conduct haptics user studies could allow researchers to access larger participant groups while a gamified approach could facilitate the data collection by making the experiment more enjoyable. To explore this concept, this work presents a gamified version of an existing psychophysical experiment that investigates response time to multisensory cues using a smartphone based on “Whac-A-Mole”. We conducted a user study to compare our gamified interface with an existing psychophysical interface with thirteen participants exploring the response time from eighteen combinations of auditory, haptic, and visual stimuli at different levels of intensities and participant preferences for both interfaces. The results demonstrate that the gamified interface successfully captured similar trends in response times and significantly elevated participant enjoyment ($p$ < 0.003), but did not result in equivalent response times to the original interface. This work shows the benefits and drawbacks of following a gamification approach when designing haptics user studies and discusses factors and trade-offs to consider when gamifying studies.
- 5 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 17 (4) , 970-977
A Comparative Analysis of Smartphone and Standard Tools for Touch Perception Assessment Across Multiple Body Sites
Tactile perception plays an important role in activities of daily living, and it can be impaired in individuals with certain medical conditions. The most common tools used to assess tactile sensation, the Semmes-Weinstein monofilaments and the 128 Hz tuning fork, have poor repeatability and resolution. Long term, we aim to provide a repeatable, high-resolution testing platform that can be used to assess vibrotactile perception through smartphones without the need for an experimenter to be present to conduct the test. We present a smartphone-based vibration perception measurement platform and compare its performance to measurements from standard monofilament and tuning fork tests. We conducted a user study with 36 healthy adults in which we tested each tool on the hand, wrist, and foot, to assess how well our smartphone-based vibration perception thresholds (VPTs) detect known trends obtained from standard tests. The smartphone platform detected statistically significant changes in VPT between the index finger and foot and also between the feet of younger adults and older adults. Our smartphone-based VPT had a moderate correlation to tuning fork-based VPT. Our overarching objective is to develop an accessible smartphone-based platform that can eventually be used to measure disease progression and regression.
- 5 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 17 (4) , 970-977
A Comparative Analysis of Smartphone and Standard Tools for Touch Perception Assessment Across Multiple Body Sites
Tactile perception plays an important role in activities of daily living, and it can be impaired in individuals with certain medical conditions. The most common tools used to assess tactile sensation, the Semmes-Weinstein monofilaments and the 128 Hz tuning fork, have poor repeatability and resolution. Long term, we aim to provide a repeatable, high-resolution testing platform that can be used to assess vibrotactile perception through smartphones without the need for an experimenter to be present to conduct the test. We present a smartphone-based vibration perception measurement platform and compare its performance to measurements from standard monofilament and tuning fork tests. We conducted a user study with 36 healthy adults in which we tested each tool on the hand, wrist, and foot, to assess how well our smartphone-based vibration perception thresholds (VPTs) detect known trends obtained from standard tests. The smartphone platform detected statistically significant changes in VPT between the index finger and foot and also between the feet of younger adults and older adults. Our smartphone-based VPT had a moderate correlation to tuning fork-based VPT. Our overarching objective is to develop an accessible smartphone-based platform that can eventually be used to measure disease progression and regression.
- 29 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (1) , 26-35
Design and Evaluation of Haptic Guidance in Ultrasound-Based Needle-Insertion Procedures
Objective: This article presents two haptic guidance systems designed to help a clinician keep an ultrasound probe steady when completing ultrasound-assisted needle insertion tasks. These procedures demand spatial reasoning and hand-eye coordination because the clinician must align a needle with the ultrasound probe and extrapolate the needle trajectory using only a 2D ultrasound image. Past research has shown that visual guidance helps the clinician align the needle, but does not help the clinician keep the ultrasound probe steady, sometimes resulting in a failed procedure. Methods: We created two separate haptic guidance systems to provide feedback if the user tilts the ultrasound probe away from the desired setpoint using (1) vibrotactile stimulation provided by a voice coil motor or (2) distributed tactile pressure provided by a pneumatic mechanism. Results: Both systems significantly reduced probe deviation and correction time to errors during a needle insertion task. We also tested the two feedback systems in a more clinically relevant setup and showed that the perceptibility of the feedback was not affected by the addition of a sterile bag placed over the actuators and gloves worn by the user. Conclusion: These studies show that both types of haptic feedback are promising for helping the user keep the ultrasound probe steady during ultrasound-assisted needle insertion tasks. Survey results indicated that users preferred the pneumatic system over the vibrotactile system. Significance: Haptic feedback may improve user performance in ultrasound-based needle-insertion procedures and shows promise in training for needle-insertion tasks and other medical procedures where guidance is required.
- 29 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (1) , 26-35
Design and Evaluation of Haptic Guidance in Ultrasound-Based Needle-Insertion Procedures
Objective: This article presents two haptic guidance systems designed to help a clinician keep an ultrasound probe steady when completing ultrasound-assisted needle insertion tasks. These procedures demand spatial reasoning and hand-eye coordination because the clinician must align a needle with the ultrasound probe and extrapolate the needle trajectory using only a 2D ultrasound image. Past research has shown that visual guidance helps the clinician align the needle, but does not help the clinician keep the ultrasound probe steady, sometimes resulting in a failed procedure. Methods: We created two separate haptic guidance systems to provide feedback if the user tilts the ultrasound probe away from the desired setpoint using (1) vibrotactile stimulation provided by a voice coil motor or (2) distributed tactile pressure provided by a pneumatic mechanism. Results: Both systems significantly reduced probe deviation and correction time to errors during a needle insertion task. We also tested the two feedback systems in a more clinically relevant setup and showed that the perceptibility of the feedback was not affected by the addition of a sterile bag placed over the actuators and gloves worn by the user. Conclusion: These studies show that both types of haptic feedback are promising for helping the user keep the ultrasound probe steady during ultrasound-assisted needle insertion tasks. Survey results indicated that users preferred the pneumatic system over the vibrotactile system. Significance: Haptic feedback may improve user performance in ultrasound-based needle-insertion procedures and shows promise in training for needle-insertion tasks and other medical procedures where guidance is required.
- 28 June 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 8 (79) , eadd4649
A compact DEA-based soft peristaltic pump for power and control of fluidic robots
Fluid-driven robotic systems typically use bulky and rigid power supplies, considerably limiting their mobility and flexibility. Although various forms of low-profile soft pumps have been demonstrated, they either are limited to specific working fluids or generate limited flow rates or pressures, making them ill-suited for widespread robotics applications. In this work, we introduce a class of centimeter-scale soft peristaltic pumps for power and control of fluidic robots. An array of high power density robust dielectric elastomer actuators (DEAs) (each weighing 1.7 grams) were adopted as soft motors, operated in a programmed pattern to produce pressure waves in a fluidic channel. We investigated and optimized the dynamic performance of the pump by analyzing the interaction between the DEAs and the fluidic channel with a fluid-structure interaction finite element model. Our soft pump achieved a maximum blocked pressure of 12.5 kilopascals and a run-out flow rate of 39 milliliters per minute with a response time of less than 0.1 second. The pump can generate bidirectional flow and adjustable pressure through control of drive parameters such as voltage and phase shift. Furthermore, the use of peristalsis makes the pump compatible with various liquids. To illustrate the versatility of the pump, we demonstrate mixing a cocktail, powering custom actuators for haptic devices, and performing closed-loop control of a soft fluidic actuator. This compact soft peristaltic pump opens up possibilities for future on-board power sources for fluid-driven robots in a variety of applications, including food handling, manufacturing, and biomedical therapeutics.
- 28 June 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 8 (79) , eadd4649
A compact DEA-based soft peristaltic pump for power and control of fluidic robots
Fluid-driven robotic systems typically use bulky and rigid power supplies, considerably limiting their mobility and flexibility. Although various forms of low-profile soft pumps have been demonstrated, they either are limited to specific working fluids or generate limited flow rates or pressures, making them ill-suited for widespread robotics applications. In this work, we introduce a class of centimeter-scale soft peristaltic pumps for power and control of fluidic robots. An array of high power density robust dielectric elastomer actuators (DEAs) (each weighing 1.7 grams) were adopted as soft motors, operated in a programmed pattern to produce pressure waves in a fluidic channel. We investigated and optimized the dynamic performance of the pump by analyzing the interaction between the DEAs and the fluidic channel with a fluid-structure interaction finite element model. Our soft pump achieved a maximum blocked pressure of 12.5 kilopascals and a run-out flow rate of 39 milliliters per minute with a response time of less than 0.1 second. The pump can generate bidirectional flow and adjustable pressure through control of drive parameters such as voltage and phase shift. Furthermore, the use of peristalsis makes the pump compatible with various liquids. To illustrate the versatility of the pump, we demonstrate mixing a cocktail, powering custom actuators for haptic devices, and performing closed-loop control of a soft fluidic actuator. This compact soft peristaltic pump opens up possibilities for future on-board power sources for fluid-driven robots in a variety of applications, including food handling, manufacturing, and biomedical therapeutics.
- 23 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 16 (4) , 672-679
Cognitive and Physical Activities Impair Perception of Smartphone Vibrations
Vibration feedback is common in everyday devices, from virtual reality systems to smartphones. However, cognitive and physical activities may impede our ability to sense vibrations from devices. In this study, we develop and characterize a smartphone platform to investigate how a shape-memory task (cognitive activity) and walking (physical activity) impair human perception of smartphone vibrations. We measured how Apple's Core Haptics Framework parameters can be used for haptics research, namely how hapticIntensity modulates amplitudes of 230 Hz vibrations. A 23-person user study found that physical ( $p< 0.001$ ) and cognitive ( $p=0.004$ ) activity increase vibration perception thresholds. Cognitive activity also increases vibration response time ( $p< 0.001$ ). This work also introduces a smartphone platform that can be used for out-of-lab vibration perception testing. Researchers can use our smartphone platform and results to design better haptic devices for diverse, unique populations.
- 23 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 16 (4) , 672-679
Cognitive and Physical Activities Impair Perception of Smartphone Vibrations
Vibration feedback is common in everyday devices, from virtual reality systems to smartphones. However, cognitive and physical activities may impede our ability to sense vibrations from devices. In this study, we develop and characterize a smartphone platform to investigate how a shape-memory task (cognitive activity) and walking (physical activity) impair human perception of smartphone vibrations. We measured how Apple's Core Haptics Framework parameters can be used for haptics research, namely how hapticIntensity modulates amplitudes of 230 Hz vibrations. A 23-person user study found that physical ( $p< 0.001$ ) and cognitive ( $p=0.004$ ) activity increase vibration perception thresholds. Cognitive activity also increases vibration response time ( $p< 0.001$ ). This work also introduces a smartphone platform that can be used for out-of-lab vibration perception testing. Researchers can use our smartphone platform and results to design better haptic devices for diverse, unique populations.
- 23 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 591-598
A Large-Area Wearable Soft Haptic Device Using Stacked Pneumatic Pouch Actuation
While haptics research has traditionally focused on the fingertips and hands, other locations on the body provide large areas of skin that could be utilized to relay large-area haptic sensations. Researchers have thus developed wearable devices that use distributed vibrotactile actuators and distributed pneumatic force displays, but these methods have limitations. In prior work, we presented a novel actuation technique involving stacking pneumatic pouches and evaluated the actuator output. In this work, we developed a wearable haptic device using this actuation technique and evaluated how the actuator output is perceived. We conducted a user study with 20 participants to evaluate users' perception thresholds, ability to localize, and ability to detect differences in contact area and compare their perception using the stacked pneumatic pouch actuation to traditional single-layer pouch actuation. We also used our device with stacked pneumatic actuation in a demonstration of a haptic hug that replicates the dynamics, pressure profile, and mapping to the human back, showcasing how this actuation technique can be used to create novel haptic stimuli.
- 23 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 591-598
A Large-Area Wearable Soft Haptic Device Using Stacked Pneumatic Pouch Actuation
While haptics research has traditionally focused on the fingertips and hands, other locations on the body provide large areas of skin that could be utilized to relay large-area haptic sensations. Researchers have thus developed wearable devices that use distributed vibrotactile actuators and distributed pneumatic force displays, but these methods have limitations. In prior work, we presented a novel actuation technique involving stacking pneumatic pouches and evaluated the actuator output. In this work, we developed a wearable haptic device using this actuation technique and evaluated how the actuator output is perceived. We conducted a user study with 20 participants to evaluate users' perception thresholds, ability to localize, and ability to detect differences in contact area and compare their perception using the stacked pneumatic pouch actuation to traditional single-layer pouch actuation. We also used our device with stacked pneumatic actuation in a demonstration of a haptic hug that replicates the dynamics, pressure profile, and mapping to the human back, showcasing how this actuation technique can be used to create novel haptic stimuli.