Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yasue Mitsukura has a total of 105 co-authors. Here are the top co-authors by number of shared publications:

  • Kota Watanabe

    Affiliation Department of Orthopedic Surgery, School of Medicine, Keio University, Tokyo, Japan

    7 shared publications
  • Satoshi Suzuki

    Affiliation Department of Orthopedic Surgery, School of Medicine, Keio University, Tokyo, Japan

    7 shared publications
  • Takahito Uchida

    Affiliations Department of Neuropsychiatry, School of Medicine, Keio University, Tokyo, Japan, Uchida Clinic, Tokyo, Japan

    7 shared publications
  • Brian Sumali

    Faculty of Science and Technology, Keio University, Yokohama, Japan

    6 shared publications
  • Brian Sumali

    Affiliation Faculty of Science and Technology, Keio University, Yokohama, Kanagawa, Japan

    6 shared publications
  • Gengtao Lin

    Affiliation Graduate School of Science and Technology, Keio University, Yokohama, Kanagawa, Japan

    6 shared publications

Latest Publications

  • Open Access

    EEG spectral biomarkers of postoperative delirium in spinal surgery: A high-resolution analysis

    by Gengtao Lin, Takahito Uchida, Kota Watanabe, Satoshi Suzuki, Masaya Nakamura, Yasue Mitsukura, Hiroyoshi Takeuchi

    Background: Postoperative delirium is common in older adults following spinal surgery, yet current EEG-based detection methods rely on broad conventional frequency bands that may obscure clinically meaningful oscillatory changes. More granular spectral approaches may reveal candidate frequency-specific features that could improve diagnostic performance. Methods: We recorded single-electrode frontal EEG (Fp1) from 47 patients at four perioperative timepoints and compared traditional band-level power with high-resolution 1-Hz spectral analysis (1–45 Hz). Group differences were evaluated using non-parametric statistics with FDR correction, and diagnostic accuracy was assessed using AUROC and threshold-optimized metrics. All diagnostics thresholds were derived and evaluated in the same dataset. Results: Seven patients (14.9%) developed delirium. Conventional band analysis detected only reduced theta power during active delirium (|r| = 0.31; AUROC = 0.53). In contrast, 1-Hz analysis revealed a richer pattern: elevated 1-Hz power (|r| = 0.27), reduced 3–7 Hz power (|r| = 0.25–0.27), and increased 14–15 Hz power (|r| = 0.22–0.26). The 23-Hz narrow-band feature achieved the best discrimination (AUROC = 0.74), despite showing no significant effect within the traditional beta band (12–30 Hz). Several frequencies remained altered even after clinical resolution of delirium. Conclusions: In this exploratory analysis, high-resolution spectral analysis identified candidate frequency-specific EEG features that distinguished delirium cases more accurately than conventional frequency bands in this cohort. Broadband averaging may not detect frequency-specific oscillatory patterns; adopting finer spectral resolution could enhance the utility of single-channel EEG for routine clinical monitoring.

  • Open Access

    Ropinirole hydrochloride mitigates oxidative stress and neuroinflammation via the PI3K–mTOR pathway in TDP-43 hiPSC-derived microglial-like cells

    by Kagistia Hana Utami, Tatsuya Kozaki, Satoru Morimoto, Hirotaka Watanabe, Kensuke Okada, Nevin Tham, Shinichi Takahashi, Yasue Mitsukura, Hideyuki Okano

    Background: Amyotrophic lateral sclerosis (ALS) is a fatal neurodegenerative disorder characterized by progressive motor neuron loss accompanied by neuroinflammation, oxidative stress, and impaired proteostasis, with pathological aggregation of TDP-43 as its defining hallmark. Microglia are recognized as central contributors to ALS pathogenesis, yet the mechanisms underlying their intrinsic dysfunction in the context of TDP-43 remain insufficiently characterized. Methods: We characterized microglia-like cells (iMGLs) differentiated from isogenic TDP-43 M337V human induced pluripotent stem cell lines. We performed integrated functional assays, transcriptomic profiling and drug repurposing analysis to systematically compare mutant and control iMGLs. To assess therapeutic potential, we evaluated the effects of ROPI, a dopamine D2 receptor agonist previously advanced to clinical trials for ALS, on disease-relevant phenotypes in TDP-43 iMGLs. Results: TDP-43 M337V/M337V iMGLs presented ALS-associated abnormalities, including cytoplasmic TDP-43 accumulation with impaired phagocytosis and elevated oxidative stress, impaired autophagy and mitophagy, altered cytokine profiles, and reduced ferritin levels. Building on our previous identification of ropinirole hydrochloride as neuroprotective for ALS motor neurons, we now show that it confers therapeutic benefits in mitigating microglial pathology. ROPI treatment significantly reduced oxidative stress and caspase-3/7 activity and partially restored cytokine homeostasis in TDP-43 M337V/M337V iMGLs, independent of autophagy/mitophagy modulation. Transcriptomic profiling revealed that ropinirole modulated disease-associated gene expression signatures involving protein folding, extracellular matrix organization, and oxidative stress responses. Furthermore, connectivity map–based analysis prioritized PI3K-Akt-mTOR inhibitors as candidates for reversing TDP-43 iMGL signatures, and ropinirole was found to modulate mTOR signaling. These converging lines of evidence support a mechanistic role for ropinirole in restoring microglial homeostasis via PI3K-mTOR pathway regulation. Taken together, our findings position ropinirole as a promising candidate dual action therapeutic candidate capable of targeting both neuronal and microglial dysfunction in ALS, suggesting broader applicability of ropinirole in modulating neuroinflammatory cascades across other neurodegenerative conditions. Conclusion: Ropinirole broadens ALS therapy from motor neurons to microglia, underscoring its promise for integrated and clinically meaningful treatment strategies.

  • Development of Benefit-Effect Assessment Method for Improving Social Acceptance of Urban Air Mobility

    by Susumu Hara, Satoshi Kusano, Yasue Mitsukura, Hiroko Kamide, Yasuo Sasaki

    In recent years, urban air mobility (UAM) technologies have been studied worldwide. However, social acceptance of UAMs and drones remains underexplored. Without adequate research, the anticipated “aerial industrial revolution” from drone use and flying vehicles may face social issues. To address this, the authors’ group proposed a social acceptance evaluation method combining subjective questionnaires with objective stress evaluations using a Kansei Analyzer based on a simple electroencephalograph and confirmed the effectiveness of this method. Related studies have assessed subjective stress from drone noise, but stress varies by the applications of the UAMs and stakeholders. It is critical to assess the stress people perceive from noise for each application and each stakeholder. This study evaluates sensitivity indices, including stress, for UAM uses, focusing on people uninvolved with UAMs, who face the greatest disadvantages. We conduct statistical tests for changes in cognitive sensitivities and physiological stress that is affected by the instruction in benefits of the UAM applications, focusing on residents uninvolved with UAMs, who face the greatest disadvantages. The study concludes with a summary of the benefit-effect assessment results.


  • Open Access

    Violet light could improve sleep quality and blood glucose levels in healthy individuals: A pilot study

    by Tomonobu Kato, Yasue Mitsukura

    Light is perceived through the retina, the light-sensing tissue layer of the eye, and can directly influence the brain. Light exposure triggers various biological responses that improve sleep quality and stabilize mood. Recently, violet light, exhibiting a unique wavelength of 360–400 nm, has garnered significant attention due to its perception through a specific receptor, marking a novel research area. Herein, we used “violet light glasses” that directly emit violet light into the human eye and investigated their effects on healthy humans in real-life settings. This study demonstrated that two hours of violet light exposure in the morning enhanced sleep quality in approximately 20% of the healthy participants and was also associated with improved blood glucose levels. Although this was a pilot study due to its small sample size, our findings indicate that violet light could potentially promote health benefits in humans.


  • Open Access

    A Novel Approach for Pulse Signals Extraction and Heart Rate Estimation With Hilbert Space Orthogonalization Using Event-Based Camera

    by Hayato Nakamura, Gengtao Lin, Yasue Mitsukura

    This paper presents a novel signal processing pipeline for estimating pulse signals, onset peaks, and heart rate using an event-based camera (EVS). EVS capture changes in brightness as a series of events, including both spatially induced events triggered by motion artifacts and temporally induced events caused by changes in skin luminance. When reconstructing pulse signals, spatially induced ON- and OFF-events within the region of interest (ROI) often occur simultaneously, canceling each other out and compromising signal stability. Additionally, biases between ON- and OFF-events can cause peak inversions under certain conditions, further destabilizing the signal. The proposed method addresses these challenges and temporal characteristics of EVS by defining event streams in a Hilbert space and applying Gram-Schmidt orthogonalization to isolate the temporally induced event stream. This enables robust estimation of pulse signals, heart rate through frequency analysis, and onset peak detection. To our knowledge, this is the first study that applies orthogonalization in Hilbert space to improve the signal processing of event-based pulse waves. The performance of the proposed approach is evaluated by comparing the extracted parameters with ground truth photoplethysmography (PPG) signals under three different lighting conditions. In the setup combining a green LED and a green optical filter, the method achieves a mean absolute error (MAE) of 1.13 BPM, a root mean square error (RMSE) of 1.69 BPM, and a peak detection accuracy of 92.72%. These results demonstrate the effectiveness of the proposed event-based method and highlight the potential of EVS for non-contact heart rate monitoring.


  • Open Access

    Advancing non-human primate welfare: An automated facial recognition system for unrestrained cynomolgus monkeys

    by Yosuke Numata, Brian Sumali, Ken’iChiro Hayashida, Hideshi Tsusaki, Yasue Mitsukura

    Cynomolgus monkeys (Macaca fascicularis) are vital in biomedical research, particularly for drug development and studying neurological diseases. However, accurately identifying individuals in group housing environments remains a significant challenge. This paper presents a near real-time facial recognition system tailored for cynomolgus monkeys, utilizing a fine-tuned Detectron2 model for face detection, followed by eigenface-based classification with Support Vector Machine (SVM) and radial basis function (RBF) kernel. The system achieved an accuracy of 97.65% in 10-fold cross-validation and identified individuals in under 1 minute under ideal conditions. This method eliminates the need for invasive identification techniques, potentially reducing stress and improving animal welfare, and has the potential to reduce the need for individualized housing or specialized enclosures. Additionally, as the system reduces the time and labor required for identifying monkeys, it might benefit research facilities with high turnover rates. This method could improve identification in non-human primate research while minimizing stress associated with traditional techniques.


  • Open Access

    Effect of carbonated water on cerebral blood flow in the frontal region: a study using near-infrared spectroscopy

    by Wataru Kosugi, Brian Sumali, Nozomu Hamada, Yasue Mitsukura

    Introduction: Carbonated water (CarbW) affects the swallowing function associated with the action of the brainstem. In addition, CarbW ingestion promotes mean blood flow in the middle cerebral artery, which is associated with blood flow to the frontal and temporal lobes. In this milieu, studies regarding the effect of drinking CarbW on brain activity are of significance. In the present study, we compared the changes in cerebral blood flow in the frontal region before and after the ingestion of CarbW or uncarbonated water (SW).Methods: Near-infrared spectroscopy was used to continuously measure the cerebral blood flow at 22 channels in the frontal region of 13 healthy young adults for 10 min before and after the ingestion of CarbW or SW. We statistically compared the changes in oxyhemoglobin concentration before and after the ingestion of CarbW or SW.Results: Compared with that before CarbW ingestion, the oxyhemoglobin concentration in the left frontal region increased after CarbW ingestion. In particular, a significant increase (p < 0.05) was observed in the ch21 region. On the contrary, no marked increase or decrease in cerebral blood flow was observed after SW ingestion compared with that before ingestion.Discussion: The activated part of the frontal region (ch21) corresponds to the vicinity of the orbitofrontal cortex, which is reportedly activated by rewarding stimuli. In addition, as the orbitofrontal cortex is located at the terminal end of the reward pathway of the mesocortical system, CarbW ingestion might have acted on the dopaminergic reward pathway of the mesocortical system.


  • Open Access

    Variability of autonomic nerve activity in dry eye with decreased tear stability

    by Minako Kaido, Reiko Arita, Yasue Mitsukura, Reiko Ishida, Kazuo Tsubota

    The autonomic nervous system plays a crucial role in the maintenance of homeostasis. Neurogenic inflammation due to decreased stability of tear film may induce changes in autonomic nerve activity, which could be associated with symptom expression.This study aimed to measure biological parameters that represent autonomic nerve activity in dry eye (DE)s caused by tear film dysfunction and investigate their relationship with symptom intensity. This prospective, cross-sectional, comparative study evaluated 34 eyes of 34 participants (mean age: 52.5 ± 13.4 years; range: 20–81 years) without keratoconjunctival damage. Nineteen eyes in the DE group showed DE symptoms and tear break-up time (TBUT) of ≤5 seconds (short TBUT DE); the 15 eyes in the non-DE group showed no DE symptoms. Autonomic nerve activity was measured for 10 minutes—starting and ending 5 minutes before and after instilling ophthalmic solution—and evaluated using the low-frequency component (LF) to the high-frequency component (HF) ratio of heart rate variability (autonomic balance). The pre-ophthalmic solution administration LF/HF ratio was not significantly different (P = 0.59) between the two groups, however, the standard deviation of the LF/HF ratio (LF/HF-SD) tended to be higher in the DE group than that in the non-DE group (P = 0.086). The DE symptom intensity was significantly related to LF/HF-SD (P = 0.005), which significantly decreased after ophthalmic solution administration in the DE group (P = 0.04). The large fluctuations in autonomic balance may be key for the understanding of the mechanism underlying DE symptoms.


  • Simultaneous multiple-stimulus auditory brain–computer interface with semi-supervised learning and prior probability distribution tuning

    by Mikito Ogino, Nozomu Hamada, Yasue Mitsukura

    Objective. Auditory brain–computer interfaces (BCIs) enable users to select commands based on the brain activity elicited by auditory stimuli. However, existing auditory BCI paradigms cannot increase the number of available commands without decreasing the selection speed, because each stimulus needs to be presented independently and sequentially under the standard oddball paradigm. To solve this problem, we propose a double-stimulus paradigm that simultaneously presents multiple auditory stimuli. Approach. For addition to an existing auditory BCI paradigm, the best discriminable sound was chosen following a subjective assessment. The new sound was located on the right-hand side and presented simultaneously with an existing sound from the left-hand side. A total of six sounds were used for implementing the auditory BCI with a 6 × 6 letter matrix. We employ semi-supervised learning (SSL) and prior probability distribution tuning to improve the accuracy of the paradigm. The SSL method involved updating of the classifier weights, and their prior probability distributions were adjusted using the following three types of distributions: uniform, empirical, and extended empirical (e-empirical). The performance was evaluated based on the BCI accuracy and information transfer rate (ITR). Main results. The double-stimulus paradigm resulted in a BCI accuracy of 67.89 ± 11.46% and an ITR of 2.67 ± 1.09 bits min −1 , in the absence of SSL and with uniform distribution. The proposed combination of SSL with e-empirical distribution improved the BCI accuracy and ITR to 74.59 ± 12.12% and 3.37 ± 1.27 bits min −1 , respectively. The event-related potential analysis revealed that contralateral and right-hemispheric dominances contributed to the BCI performance improvement. Significance. Our study demonstrated that a BCI based on multiple simultaneous auditory stimuli, incorporating SSL and e-empirical prior distribution, can increase the number of commands without sacrificing typing speed beyond the acceptable level of accuracy.


  • Open Access

    Contactless continuous heart rate monitoring system using ballistocardiography

    by Brian Sumali, Yasue Mitsukura, Toshihiko Nishimura

    Cardiovascular disease is the number one cause of death in the world and is a serious problem. In the case of cardiopulmonary arrest due to myocardial infarction, the survival rate is as low as 13.3% one month after resuscitation, which birthed the need for continuous heart monitoring. In this study, we develop a Ballistocardiogram (BCG) measurement system using a load cell installed on a chair and a heart rate estimation algorithm that is robust to waveform changes, with the aim of constructing a non-contact heart rate acquisition system. The proposed system was evaluated by utilizing data obtained from 13 healthy subjects and 1 subject with abnormal ECG who were simultaneously measured with ECG. The output of the BCG system was confirmed to change with the same period as the ECG data obtained as the correct answer, and the synchronization of the R-peak positions was confirmed for all cases. As a result of comparing the heart rate intervals estimated from BCG and those obtained from ECG, it was confirmed that the same heart rate variability (HRV) features could be obtained even for abnormal ECG subject.