Anderson Araújo Rocha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anderson Araújo Rocha has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Christiane Duyck
3 shared publications- Mônica Almeida Tostes
Departamento de Odontopediatria, Faculdade de Odontologia, Universidade Federal Fluminense (UFF) – Niterói (RJ), Brazil
2 shared publications Rodolfo Lorençatto
2 shared publications- Yutao Xing
Universidade Federal Fluminense
2 shared publications - Adriana Gioda
Department of Chemistry, Pontifical Catholic University of Rio de Janeiro (PUC-Rio), Rio de Janeiro, Brazil
1 shared publication Aline de Almeida Neves
1 shared publication
Latest Publications
- Open Access
- 27 June 2026
- Published by Taylor & Francis in Petroleum Science and Technology
- p. 1-19
Feasibility study of laser technology for inducing complexation reactions of scale in oil production
- 27 June 2026
- Published by Taylor & Francis in Petroleum Science and Technology
- p. 1-19
Open AccessFeasibility study of laser technology for inducing complexation reactions of scale in oil production
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Anais da Academia Brasileira de Ciências
- Vol. 98 (2) , e20250649
Non-destructive characterization of atmospheric particulate matter using SEM-EDS: Elemental mapping as a tool for chemical composition assessment
The scanning electron microscopy (SEM) technique, coupled with energy dispersive X-ray spectrometry (EDS), is a key tool for characterizing particulate matter (PM), offering advantages such as in natura and non-destructive sample analysis. Published studies typically present SEM images alongside the elemental spectrum from EDS. Less commonly explored in the literature, the EDS elemental maps, performed with successive scans at appropriate resolution, can identify substances even when SEM analysis is compromised. In this present study performed PM analyses via SEM-EDS on samples collected using quartz and fiberglass filters during an environmental monitoring campaign across three regions of Rio de Janeiro, with no filter pre-treatment required. Blank filter characterization revealed that fiberglass filters contained Na, Ba, and Zn (~ 6%), while quartz filters is cleaner. The analysis enabled PM classification as organic/inorganic and natural/anthropogenic. Organic particles in the inland city included pollen and soot from biomass burning, while in the metropolitan area, clusters of small carbon spheres were linked to incomplete fuel combustion. Inorganic particles in the environmental reserve included aluminosilicates from crustal sources, while the inland city had iron-rich particles. Despite the long operation time, EDS elementary maps identified overlapping elements, enabling more accurate determination of PM’s chemical composition.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Anais da Academia Brasileira de Ciências
- Vol. 98 (2) , e20250649
Open AccessNon-destructive characterization of atmospheric particulate matter using SEM-EDS: Elemental mapping as a tool for chemical composition assessment
The scanning electron microscopy (SEM) technique, coupled with energy dispersive X-ray spectrometry (EDS), is a key tool for characterizing particulate matter (PM), offering advantages such as in natura and non-destructive sample analysis. Published studies typically present SEM images alongside the elemental spectrum from EDS. Less commonly explored in the literature, the EDS elemental maps, performed with successive scans at appropriate resolution, can identify substances even when SEM analysis is compromised. In this present study performed PM analyses via SEM-EDS on samples collected using quartz and fiberglass filters during an environmental monitoring campaign across three regions of Rio de Janeiro, with no filter pre-treatment required. Blank filter characterization revealed that fiberglass filters contained Na, Ba, and Zn (~ 6%), while quartz filters is cleaner. The analysis enabled PM classification as organic/inorganic and natural/anthropogenic. Organic particles in the inland city included pollen and soot from biomass burning, while in the metropolitan area, clusters of small carbon spheres were linked to incomplete fuel combustion. Inorganic particles in the environmental reserve included aluminosilicates from crustal sources, while the inland city had iron-rich particles. Despite the long operation time, EDS elementary maps identified overlapping elements, enabling more accurate determination of PM’s chemical composition.
- Open Access
- 28 July 2025
- Published by Wiley in European Journal of Oral Sciences
- Vol. 133 (6) , e70034
Evaluation of Streptococcus mutans biofilm formation on fluoride‐releasing materials used as pit and fissure sealants
This in vitro study evaluated fluoride release and Streptococcus mutans biofilm formation on four types of dental sealants: a giomer, resin‐modified glass ionomer, compomer, and a fluoride‐free composite (control). Discs were prepared as per the manufacturers’ instructions, and they were placed in tubes containing ultrapure water. Fluoride release was measured after 2, 7, and 30 days using ion chromatography, and biofilm formation was analyzed via scanning electron microscopy (SEM). A repeated‐measures linear mixed model with log transformation and Bonferroni‐corrected post‐hoc tests was applied. The resin‐modified glass ionomer showed the highest fluoride release, followed by the giomer, with increasing values over time. Compomer and the fluoride‐free composite exhibited low, stable fluoride levels. SEM confirmed S. mutans biofilm on all materials. These findings highlight distinct fluoride release profiles and suggest that materials with higher fluoride release may offer improved long‐term protection against cariogenic biofilm formation.
- 28 July 2025
- Published by Wiley in European Journal of Oral Sciences
- Vol. 133 (6) , e70034
Open AccessEvaluation of Streptococcus mutans biofilm formation on fluoride‐releasing materials used as pit and fissure sealants
This in vitro study evaluated fluoride release and Streptococcus mutans biofilm formation on four types of dental sealants: a giomer, resin‐modified glass ionomer, compomer, and a fluoride‐free composite (control). Discs were prepared as per the manufacturers’ instructions, and they were placed in tubes containing ultrapure water. Fluoride release was measured after 2, 7, and 30 days using ion chromatography, and biofilm formation was analyzed via scanning electron microscopy (SEM). A repeated‐measures linear mixed model with log transformation and Bonferroni‐corrected post‐hoc tests was applied. The resin‐modified glass ionomer showed the highest fluoride release, followed by the giomer, with increasing values over time. Compomer and the fluoride‐free composite exhibited low, stable fluoride levels. SEM confirmed S. mutans biofilm on all materials. These findings highlight distinct fluoride release profiles and suggest that materials with higher fluoride release may offer improved long‐term protection against cariogenic biofilm formation.
- 1 January 2023
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
Fit-for-Purpose MIP OES Method to Meet the Requirements of the Brazilian Regulations for K and Na in Coconut Water, and Nutritional Assessment
The Brazilian regulations for processed coconut water establish the range concentrations of Na and K, being necessary high-throughput analytical methods, as microwave-induced plasma optical emission spectrometry (MIP OES) for quality control. Samples of natural (green and mature) and processed coconut water were treated by acid decomposition assisted by microwave radiation before their MIP OES analysis. Recoveries for Na and K were 103 and 95%, whereas the relative standard deviation (RSDs) were 7.6 and 1.3%, respectively. The limit of detection (LOD) was 1.77 mg kg-1 for K and 2.31 mg kg-1 for Na. Sodium and K were determined in the ranges of, respectively, 27-490 and 1,600-3,500 mg L-1 in natural samples, whereas in processed samples the ranges were 26-168 and 814-2,054 mg L-1. K-means cluster analysis identified a group of processed samples with compositions similar to green coconut water. All the processed samples were in accordance with the established regulation, except one dehydrated sample for which K content was below the accepted range. Natural coconut water is an excellent source of K in the diet as its daily consumption can supply more than 20% of the recommended daily ingestion of K for adults and 30% for children.
- 1 January 2023
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
Fit-for-Purpose MIP OES Method to Meet the Requirements of the Brazilian Regulations for K and Na in Coconut Water, and Nutritional Assessment
The Brazilian regulations for processed coconut water establish the range concentrations of Na and K, being necessary high-throughput analytical methods, as microwave-induced plasma optical emission spectrometry (MIP OES) for quality control. Samples of natural (green and mature) and processed coconut water were treated by acid decomposition assisted by microwave radiation before their MIP OES analysis. Recoveries for Na and K were 103 and 95%, whereas the relative standard deviation (RSDs) were 7.6 and 1.3%, respectively. The limit of detection (LOD) was 1.77 mg kg-1 for K and 2.31 mg kg-1 for Na. Sodium and K were determined in the ranges of, respectively, 27-490 and 1,600-3,500 mg L-1 in natural samples, whereas in processed samples the ranges were 26-168 and 814-2,054 mg L-1. K-means cluster analysis identified a group of processed samples with compositions similar to green coconut water. All the processed samples were in accordance with the established regulation, except one dehydrated sample for which K content was below the accepted range. Natural coconut water is an excellent source of K in the diet as its daily consumption can supply more than 20% of the recommended daily ingestion of K for adults and 30% for children.
- 1 December 2020
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1140, 41-49
Aerosol dilution as a new sample introduction strategy for microwave-induced plasma optical emission spectrometry
- 1 December 2020
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1140, 41-49
Aerosol dilution as a new sample introduction strategy for microwave-induced plasma optical emission spectrometry
- Open Access
- 1 January 2019
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
- Vol. 30 (6) , 1309-1316
Automatized Separation of Fractions from Petroleum Based on Spectrophotometric Signal Derivative Using Open-Source Hardware for the Determination of Ni and V Linked to Porphyrins
- 1 January 2019
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
- Vol. 30 (6) , 1309-1316
Open AccessAutomatized Separation of Fractions from Petroleum Based on Spectrophotometric Signal Derivative Using Open-Source Hardware for the Determination of Ni and V Linked to Porphyrins
- 10 November 2017
- Published by Medical Journals Sweden AB in Acta Odontologica Scandinavica
- Vol. 76 (3) , 188-194
Effect of dentifrice containing fTCP, CPP-ACP and fluoride in the prevention of enamel demineralization
Objective: To evaluate the effect of different fluoride- and calcium- and/or phosphate-containing products on their ability to prevent enamel demineralization under pH cycling conditions. Material and methods: Enamel bovine specimens were assigned to the following groups: G1-MPP (MI Paste Plus, 0.2% NaF, Recaldent™, GC Corporation Tokyo, Japan); G2-FD (Crest™ Cavity Protection, 0.243% NaF, Procter & Gamble, USA); G3-CLP (Clinpro™ 5000, 1.1% NaF, 3M ESPE, USA); and G4-CO (Control without fluoride, Silica-based dentifrice; Daudt Ltda, Brazil). The specimens were soaked in demineralizing solution for 6 h and remineralizing solution for 18 h alternatively for 10 days. The toothpaste was prepared with deionized water in a 1:3 ratio (w/v) for three minutes daily. The solutions were renewed every 48 h. After cycling, enamel changes were analysed by percentage change of SMH (%SMH) and energy-dispersive X-ray spectroscopy (EDS). The %SMH value observed for G3-CLP (2.9 ± 39.2) was higher than that found in G4-CO (−13.0 ± 20.7), G1-MPP (−8.9 ± 20.9) and G2-FD (−3.9 ± 27.1). The %SMH was similar for all treatment groups (one-way ANOVA and Tukey’s HSD; p < .05). The pH, Ca2+ and Ptotal in the remineralization solutions were not different among all groups (Kruskal–Wallis; p < .05). At 24 h, the Ca2+ concentration in the demineralization solution was significantly lower in G1-MPP. Ca2+ concentration increased in all groups after 48 h, except for G3-CLP. The EDX quantitative analysis showed that the atomic % of elements is lower level at G4-CO. Conclusions: The Clinpro™ 5000 demonstrated having the most protective effect against demineralization; however, the % SMH was similar for all groups.
- 10 November 2017
- Published by Medical Journals Sweden AB in Acta Odontologica Scandinavica
- Vol. 76 (3) , 188-194
Effect of dentifrice containing fTCP, CPP-ACP and fluoride in the prevention of enamel demineralization
Objective: To evaluate the effect of different fluoride- and calcium- and/or phosphate-containing products on their ability to prevent enamel demineralization under pH cycling conditions. Material and methods: Enamel bovine specimens were assigned to the following groups: G1-MPP (MI Paste Plus, 0.2% NaF, Recaldent™, GC Corporation Tokyo, Japan); G2-FD (Crest™ Cavity Protection, 0.243% NaF, Procter & Gamble, USA); G3-CLP (Clinpro™ 5000, 1.1% NaF, 3M ESPE, USA); and G4-CO (Control without fluoride, Silica-based dentifrice; Daudt Ltda, Brazil). The specimens were soaked in demineralizing solution for 6 h and remineralizing solution for 18 h alternatively for 10 days. The toothpaste was prepared with deionized water in a 1:3 ratio (w/v) for three minutes daily. The solutions were renewed every 48 h. After cycling, enamel changes were analysed by percentage change of SMH (%SMH) and energy-dispersive X-ray spectroscopy (EDS). The %SMH value observed for G3-CLP (2.9 ± 39.2) was higher than that found in G4-CO (−13.0 ± 20.7), G1-MPP (−8.9 ± 20.9) and G2-FD (−3.9 ± 27.1). The %SMH was similar for all treatment groups (one-way ANOVA and Tukey’s HSD; p < .05). The pH, Ca2+ and Ptotal in the remineralization solutions were not different among all groups (Kruskal–Wallis; p < .05). At 24 h, the Ca2+ concentration in the demineralization solution was significantly lower in G1-MPP. Ca2+ concentration increased in all groups after 48 h, except for G3-CLP. The EDX quantitative analysis showed that the atomic % of elements is lower level at G4-CO. Conclusions: The Clinpro™ 5000 demonstrated having the most protective effect against demineralization; however, the % SMH was similar for all groups.
- Open Access
- 1 October 1998
- Published by FapUNIFESP (SciELO) in Química Nova
- Vol. 21 (5) , 584-589
Determinação de fósforo orgânico em águas de produção petrolífera por ICP- AES e ICP- MS após pré-concentração em coluna de sílica-C18
Results on the optimization of analytical methods for the determination of phosphorus in phosphino-polycarboxylate (PPCA), used frequently as scale inhibitor during oil production, by ICP-AES and ICP-MS are presented. Due to the complex matrix of production waters (brines) and their high concentration in inorganic phosphorus, the separation of organic phosphorus prior to its determination is necessary. In this work, minicolumns of silica immobilized C18 were used. Optimization of the separation step resulted in the following working conditions: (1) prewashing of the column with methanol (80% v/v); (2) use of a flow rate of 5 mL/min and 10 mL/min, respectively, for the preconditioning step and for percolation of the water sample; (3) final elution of organic phosphorus with 7 mL of buffer of H3BO3/NaOH (0.05 M, pH 9) with a flow rate of 1 mL/min. Sample detection limits (3s) for different combinations of nebulizers and spectrometric methods, based on 10 mL water aliquots, are: ICP-AES -Cross flow (47 mg/L) and Ultrasonic (18 mug/L); ICP-MS -Cross flow (1.2 mug/L), Cyclonic (0.7 mug/L) and Ultrasonic (0.5 mug/L). Typical recoveries of organic phosphorus are between 90 and 95% and the repeatability of the whole procedure is better than 10%. The developed methodology was applied successfully to samples from the oil-well NA 46, platform PNA 2, Campos basin, Brazil. Assessment of the PPCA inhibitor was possible at lower concentrations than achieved by current analytical methods, resulting in benefits such as reduced cost of chemicals, postponed oil production and lower environmental impacts
- 1 October 1998
- Published by FapUNIFESP (SciELO) in Química Nova
- Vol. 21 (5) , 584-589
Open AccessDeterminação de fósforo orgânico em águas de produção petrolífera por ICP- AES e ICP- MS após pré-concentração em coluna de sílica-C18
Results on the optimization of analytical methods for the determination of phosphorus in phosphino-polycarboxylate (PPCA), used frequently as scale inhibitor during oil production, by ICP-AES and ICP-MS are presented. Due to the complex matrix of production waters (brines) and their high concentration in inorganic phosphorus, the separation of organic phosphorus prior to its determination is necessary. In this work, minicolumns of silica immobilized C18 were used. Optimization of the separation step resulted in the following working conditions: (1) prewashing of the column with methanol (80% v/v); (2) use of a flow rate of 5 mL/min and 10 mL/min, respectively, for the preconditioning step and for percolation of the water sample; (3) final elution of organic phosphorus with 7 mL of buffer of H3BO3/NaOH (0.05 M, pH 9) with a flow rate of 1 mL/min. Sample detection limits (3s) for different combinations of nebulizers and spectrometric methods, based on 10 mL water aliquots, are: ICP-AES -Cross flow (47 mg/L) and Ultrasonic (18 mug/L); ICP-MS -Cross flow (1.2 mug/L), Cyclonic (0.7 mug/L) and Ultrasonic (0.5 mug/L). Typical recoveries of organic phosphorus are between 90 and 95% and the repeatability of the whole procedure is better than 10%. The developed methodology was applied successfully to samples from the oil-well NA 46, platform PNA 2, Campos basin, Brazil. Assessment of the PPCA inhibitor was possible at lower concentrations than achieved by current analytical methods, resulting in benefits such as reduced cost of chemicals, postponed oil production and lower environmental impacts