Zipin Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zipin Zhang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Jiali Zhai
Anhui University of Chinese Medicine, School of Pharmacy, Hefei 230012, China
3 shared publicationsLei Tian
Anhui University of Chinese Medicine, School of Pharmacy, Hefei, 230012, China
3 shared publications- Zuzhi Zhao
Anhui Medical University, School of Basic Medical Sciences, Hefei, 230032, China
3 shared publications Can Peng
Anhui University of Chinese Medicine, School of Pharmacy, Hefei 230012, China
1 shared publicationHongsu Zhao
Anhui University of Chinese Medicine, School of Pharmacy, Hefei 230012, China
1 shared publicationMengmeng Song
Anhui Medical University, School of Basic Medical Sciences, Hefei, 230032, China
1 shared publication
Latest Publications
- 27 January 2023
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (6) , 1265-1274
A regenerable electrochemical sensor for electro-inactive cyclovirobuxine D detection in biological samples
A regenerable electrochemical sensor for CVB-D with using polymerized bromothymol blue (poly-BTB) as both a recognition element and an electrochemical probe, and the current decrease as the signal read-out.
- 27 January 2023
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (6) , 1265-1274
A regenerable electrochemical sensor for electro-inactive cyclovirobuxine D detection in biological samples
A regenerable electrochemical sensor for CVB-D with using polymerized bromothymol blue (poly-BTB) as both a recognition element and an electrochemical probe, and the current decrease as the signal read-out.
- 22 May 2020
- Published by Springer Nature in Microchimica Acta
- Vol. 187 (6) , 1-9
Integrating brucine with carbon nanotubes toward electrochemical sensing of hydroxylamine
Based on the intrinsic electrochemical features of brucine integrated with carbon nanotubes (brucine/SWNTs), dimeric quinoid brucine was electrochemically generated by electroactivation of a brucine/SWNTs-modified GC electrode and used as a novel electrocatalyst for efficient electro-oxidation of hydroxylamine (HA). The electrocatalytic activity was investigated with cyclic voltammetry in the range pH 2.0 to pH 11.0, and the best electrocatalytic performance of the electrocatalyst was obtained at pH 10.0. By taking advantage of the electrocatalytic activity of the dimeric quinoid brucine toward HA, we have developed an electrochemical sensor for HA measurements based on a brucine/SWNTS-modified GC electrode using amperometry with the applied potential of + 0.1 V (vs. Ag/AgCl). Under the optimized conditions, the current response toward HA concentration shows a linear relationship in the dynamic ranges of 0.1–10 μM and 10–1000 μM with a detection limit of 0.021 μM based on the 3σ criterion. The sensor was used to assay HA in pharmaceuticals including hydroxyurea tablets and pralidoxime iodide injections with satisfactory results. The spike-and-recovery for samples of tap water (n = 9) and lake water (n = 9) was within 97.17–100.16%. Schematic illustration of electrochemical sensing of hydroxylamine (HA) enabled by integrating brucine with single-walled carbon nanotube (brucine/SWNTs) based on electro-activation of brucine/SWNTs-modified GC electrode
- 22 May 2020
- Published by Springer Nature in Microchimica Acta
- Vol. 187 (6) , 1-9
Integrating brucine with carbon nanotubes toward electrochemical sensing of hydroxylamine
Based on the intrinsic electrochemical features of brucine integrated with carbon nanotubes (brucine/SWNTs), dimeric quinoid brucine was electrochemically generated by electroactivation of a brucine/SWNTs-modified GC electrode and used as a novel electrocatalyst for efficient electro-oxidation of hydroxylamine (HA). The electrocatalytic activity was investigated with cyclic voltammetry in the range pH 2.0 to pH 11.0, and the best electrocatalytic performance of the electrocatalyst was obtained at pH 10.0. By taking advantage of the electrocatalytic activity of the dimeric quinoid brucine toward HA, we have developed an electrochemical sensor for HA measurements based on a brucine/SWNTS-modified GC electrode using amperometry with the applied potential of + 0.1 V (vs. Ag/AgCl). Under the optimized conditions, the current response toward HA concentration shows a linear relationship in the dynamic ranges of 0.1–10 μM and 10–1000 μM with a detection limit of 0.021 μM based on the 3σ criterion. The sensor was used to assay HA in pharmaceuticals including hydroxyurea tablets and pralidoxime iodide injections with satisfactory results. The spike-and-recovery for samples of tap water (n = 9) and lake water (n = 9) was within 97.17–100.16%. Schematic illustration of electrochemical sensing of hydroxylamine (HA) enabled by integrating brucine with single-walled carbon nanotube (brucine/SWNTs) based on electro-activation of brucine/SWNTs-modified GC electrode
- 1 February 2019
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 11 (10) , 1324-1330
A facile voltammetric method for detection of heparin in plasma based on the polyethylenimine modified electrode
The development of a technically simple yet effective method for the quantification of heparin in plasma is of great importance because of its high biological and clinical relevance. This study demonstrates a facile and cost-effective voltammetric method for detection of heparin in plasma based on the polyethylenimine (PEI) modified electrode. Herein, PEI was immobilized onto the electrode surface via carbon nanotubes and the redox probe ferricyanide (i.e., Fe(CN)6 3−) was afterwards confined owing to the electrostatic interaction between Fe(CN)6 3− and PEI. The presence of heparin caused Fe(CN)6 3− to be removed from the electrode surface because of the higher affinity of PEI toward heparin than toward Fe(CN)6 3−, which validates heparin detection using the current decrease of confined Fe(CN)6 3− as the signal readout. The method shows dynamic linear concentration of heparin in the ranges of 0.1–2 U mL−1 and 2–20 U mL−1 which cover the clinically relevant levels of heparin. With the animal experiments, the method has been demonstrated to be highly selective and quite effective for heparin level quantification in plasma. This study offers a facile voltammetric method for heparin detection with less technically demanding and simple operating procedures, which could be envisaged to find more biological and clinical applications associated with heparin.
- 1 February 2019
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 11 (10) , 1324-1330
A facile voltammetric method for detection of heparin in plasma based on the polyethylenimine modified electrode
The development of a technically simple yet effective method for the quantification of heparin in plasma is of great importance because of its high biological and clinical relevance. This study demonstrates a facile and cost-effective voltammetric method for detection of heparin in plasma based on the polyethylenimine (PEI) modified electrode. Herein, PEI was immobilized onto the electrode surface via carbon nanotubes and the redox probe ferricyanide (i.e., Fe(CN)6 3−) was afterwards confined owing to the electrostatic interaction between Fe(CN)6 3− and PEI. The presence of heparin caused Fe(CN)6 3− to be removed from the electrode surface because of the higher affinity of PEI toward heparin than toward Fe(CN)6 3−, which validates heparin detection using the current decrease of confined Fe(CN)6 3− as the signal readout. The method shows dynamic linear concentration of heparin in the ranges of 0.1–2 U mL−1 and 2–20 U mL−1 which cover the clinically relevant levels of heparin. With the animal experiments, the method has been demonstrated to be highly selective and quite effective for heparin level quantification in plasma. This study offers a facile voltammetric method for heparin detection with less technically demanding and simple operating procedures, which could be envisaged to find more biological and clinical applications associated with heparin.