Jiangbo Qian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiangbo Qian has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Ao Liu
North China Electric Power University, Baoding, Hebei Province 071003, People’s Republic of China
3 shared publicationsShuo Wang
2 shared publications- Ao Liu
Yanzhao Electric Power Laboratory, North China Electric Power University, Baoding 071003, China
1 shared publication Cheng Peng
Hebei Key Laboratory of Low-carbon and Efficient Power generation Technology, North China Electric Power University, Baoding, China
1 shared publication- Gengda Li
National Energy Group New Energy Technology Research Institute Company Ltd., Beijing, China
1 shared publication Guanghai Lu
1 shared publication
Latest Publications
- 27 January 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (28) , 285105
Theoretical and Experimental Study on Air Humidity Measurement Using Temperature-Compensated Microwave Coaxial Resonant Cavity
Relative humidity (RH) as an important physical parameter, requires real-time and accurate monitoring of its levels, which is crucial for manufacturing, environmental monitoring, and the medical industry. However, temperature fluctuations in the measurement environment have a significant impact on sensor sensitivity. To this end, this study proposes a λ/2 microwave coaxial resonant cavity with temperature compensation and applies it as a sensing device for RH measurement. First, based on the effective medium theory, a dielectric constant calculation model for humid air was established, and its dielectric properties were analyzed. Subsequently, a comprehensive theoretical measurement model was developed by integrating microwave coaxial resonant cavity theory. Through parameter scanning, the simulation modeling of the resonant cavity was optimized, determining the characteristic dimensions that enable the cavity to achieve high energy absorption efficiency and significant modal isolation characteristics, thereby verifying the global optimality of the structural parameters. Finally, temperature characteristic experiments were conducted to correct measurement errors caused by thermal expansion effects. RH measurement experiments were performed to validate the performance of the designed resonant cavity. The experimental results demonstrate that the resonant cavity achieves a maximum sensitivity of 234 kHz/%RH within the 20%RH–90%RH range, with an overall average sensitivity of 53.34 kHz/%RH. Additionally, it exhibits advantages such as fast response and stable measurement, enabling online monitoring of RH.
- 27 January 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (28) , 285105
Theoretical and Experimental Study on Air Humidity Measurement Using Temperature-Compensated Microwave Coaxial Resonant Cavity
Relative humidity (RH) as an important physical parameter, requires real-time and accurate monitoring of its levels, which is crucial for manufacturing, environmental monitoring, and the medical industry. However, temperature fluctuations in the measurement environment have a significant impact on sensor sensitivity. To this end, this study proposes a λ/2 microwave coaxial resonant cavity with temperature compensation and applies it as a sensing device for RH measurement. First, based on the effective medium theory, a dielectric constant calculation model for humid air was established, and its dielectric properties were analyzed. Subsequently, a comprehensive theoretical measurement model was developed by integrating microwave coaxial resonant cavity theory. Through parameter scanning, the simulation modeling of the resonant cavity was optimized, determining the characteristic dimensions that enable the cavity to achieve high energy absorption efficiency and significant modal isolation characteristics, thereby verifying the global optimality of the structural parameters. Finally, temperature characteristic experiments were conducted to correct measurement errors caused by thermal expansion effects. RH measurement experiments were performed to validate the performance of the designed resonant cavity. The experimental results demonstrate that the resonant cavity achieves a maximum sensitivity of 234 kHz/%RH within the 20%RH–90%RH range, with an overall average sensitivity of 53.34 kHz/%RH. Additionally, it exhibits advantages such as fast response and stable measurement, enabling online monitoring of RH.
- 10 January 2026
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 108
Research on the measurement method of pulverized coal concentration based on microwave loss
- 10 January 2026
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 108
Research on the measurement method of pulverized coal concentration based on microwave loss
- 20 November 2025
- Published by Elsevier in Measurement
- Vol. 259
A temperature-independent coaxial resonant cavity method for comprehensive quality assessment of insulating oil with multiphase impurities
- 20 November 2025
- Published by Elsevier in Measurement
- Vol. 259
A temperature-independent coaxial resonant cavity method for comprehensive quality assessment of insulating oil with multiphase impurities
- Open Access
Icing Detection of Wind Turbine Blades Based on an Improved PP-YOLOE Detection Network
In cold and highly humid regions, wind turbine blades (WTB) are susceptible to icing, which can have a significant impact on the security and economic operation of turbines. Therefore, precise and prompt icing status detection is pivotal for maintaining wind turbine operational normalcy. In this research, an improved PP-YOLOE network is developed for classifying and detecting the icing state of WTB. First, a dataset of WTB icing is constructed based on a wind tunnel laboratory and expanded to improve the generalization of the model. To enhance feature representation, the network architecture was improved by embedding a coordinate attention (CA) mechanism and integrating atrous spatial pyramid pooling (ASPP) to better capture multi-scale contextual information. Moreover, a key innovation of this work is the novel application of a particle swarm optimization (PSO) algorithm to systematically automate hyperparameter tuning. Through ablation experiments and comparative tests, the improved PP-YOLOE network demonstrates superior overall performance on this dataset, achieving a multiple average precision of 0.94. It surpasses the original model across multiple evaluation metrics, indicating a robust and meaningful enhancement. The improved PP-YOLOE network proposed in this study provides a promising and effective method for WTB icing detection. This work provides a paradigm for applying advanced deep learning techniques to enhance intelligent industrial inspection tasks.
Open AccessIcing Detection of Wind Turbine Blades Based on an Improved PP-YOLOE Detection Network
In cold and highly humid regions, wind turbine blades (WTB) are susceptible to icing, which can have a significant impact on the security and economic operation of turbines. Therefore, precise and prompt icing status detection is pivotal for maintaining wind turbine operational normalcy. In this research, an improved PP-YOLOE network is developed for classifying and detecting the icing state of WTB. First, a dataset of WTB icing is constructed based on a wind tunnel laboratory and expanded to improve the generalization of the model. To enhance feature representation, the network architecture was improved by embedding a coordinate attention (CA) mechanism and integrating atrous spatial pyramid pooling (ASPP) to better capture multi-scale contextual information. Moreover, a key innovation of this work is the novel application of a particle swarm optimization (PSO) algorithm to systematically automate hyperparameter tuning. Through ablation experiments and comparative tests, the improved PP-YOLOE network demonstrates superior overall performance on this dataset, achieving a multiple average precision of 0.94. It surpasses the original model across multiple evaluation metrics, indicating a robust and meaningful enhancement. The improved PP-YOLOE network proposed in this study provides a promising and effective method for WTB icing detection. This work provides a paradigm for applying advanced deep learning techniques to enhance intelligent industrial inspection tasks.
- 22 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (5) , 2564-2571
Dielectric Spectroscopy of Aqueous Insulating Oil Based on Maxwell-Wagner Modified Model
The dielectric change law of aqueous insulating oil has an important impact on the safe operation of transformers. In this paper, the integration method is used to modify the Maxwell-wanger non-uniform dielectric model to make it suitable for aqueous insulating oil, and the reliability of the new model is verified. The experimental results show that when the water content is 20 ppm, the maximum error of the real part of the complex dielectric constant of the insulating oil does not exceed 0.0541%, and the maximum error of the imaginary part does not exceed 1.076%. Finally, based on this model, the dielectric spectrum of the aqueous insulating oil is obtained, the variation law of the real part and the imaginary part of the aqueous insulating oil under different conditions are revealed, and the internal reasons for the dielectric properties of the aqueous insulating oil with temperature, frequency, and moisture content are analyzed, which provides an important reference data for the evaluation and online monitoring of the insulation performance of the aqueous insulating oil.
- 22 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (5) , 2564-2571
Dielectric Spectroscopy of Aqueous Insulating Oil Based on Maxwell-Wagner Modified Model
The dielectric change law of aqueous insulating oil has an important impact on the safe operation of transformers. In this paper, the integration method is used to modify the Maxwell-wanger non-uniform dielectric model to make it suitable for aqueous insulating oil, and the reliability of the new model is verified. The experimental results show that when the water content is 20 ppm, the maximum error of the real part of the complex dielectric constant of the insulating oil does not exceed 0.0541%, and the maximum error of the imaginary part does not exceed 1.076%. Finally, based on this model, the dielectric spectrum of the aqueous insulating oil is obtained, the variation law of the real part and the imaginary part of the aqueous insulating oil under different conditions are revealed, and the internal reasons for the dielectric properties of the aqueous insulating oil with temperature, frequency, and moisture content are analyzed, which provides an important reference data for the evaluation and online monitoring of the insulation performance of the aqueous insulating oil.
- 27 December 2022
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 145 (5) , 1-14
Design of Energy Storage for Assisting Extraction Condensing Unit to Peak Regulation and Frequency Modulation
Coupling energy storage system is one of the potential ways to improve the peak regulation and frequency modulation performance for the existing combined heat power plant. Based on the characteristics of energy storage types, achieving the accurate parameter design for multiple energy storage has been a necessary step to coordinate regulation. In this work, heat storage tank for peak regulation and flywheel energy storage for frequency modulation have been carried out, including the parameters design and performance evaluation for their charging (or discharging) rate and capacity, and the collaborative optimization of dual energy storage systems has been realized. First, the effects of increasing peak depth, load change rate (frequency modulation) range, and energy storage parameters are further analyzed. It is worth noting that the power curves of regional thermal and electrical loads would be adjusted according to the set requirements. Results showed that, the set rate of charge and discharge as well as the capacity of energy storage is conducive to improving the peak regulation depth of the system, and the peak regulation depth would reach its limit at 96.35 MW and 40.83 MWh in the calculation cases, respectively. On this basis, the cooperative regulation of dual energy storage can further increase the capability of peak regulation and frequency modulation. The extreme point is that when the charge and discharge rates are both 3 MW, and meanwhile the peak clipping coefficient, a self-defined parameter, reaches 22.34 MW. Furthermore, an example calculation is carried out to verify the reliability of the design method of energy storage parameter. The specific parameters set include the charging and discharging rate of energy storage tank equipment is 61.67 MW, and its capacity is 10.64 MWh, and the charging and discharging rate of flywheel energy storage equipment is 3 MW. The example results confirmed that there was only a very small error between the set results and the calculation results. Finally, the thermal-electric load region has been drawn to contrast the key roles of dual energy storage systems, which indicates that the heat storage tank can be used for peak regulation and flywheel energy storage for frequency modulation. Overall, the parameter design method for dual energy storage can meet the engineering requirements and provide a new direction for the subsequent parameter design of thermal power unit coupled energy storage system.
- 27 December 2022
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 145 (5) , 1-14
Design of Energy Storage for Assisting Extraction Condensing Unit to Peak Regulation and Frequency Modulation
Coupling energy storage system is one of the potential ways to improve the peak regulation and frequency modulation performance for the existing combined heat power plant. Based on the characteristics of energy storage types, achieving the accurate parameter design for multiple energy storage has been a necessary step to coordinate regulation. In this work, heat storage tank for peak regulation and flywheel energy storage for frequency modulation have been carried out, including the parameters design and performance evaluation for their charging (or discharging) rate and capacity, and the collaborative optimization of dual energy storage systems has been realized. First, the effects of increasing peak depth, load change rate (frequency modulation) range, and energy storage parameters are further analyzed. It is worth noting that the power curves of regional thermal and electrical loads would be adjusted according to the set requirements. Results showed that, the set rate of charge and discharge as well as the capacity of energy storage is conducive to improving the peak regulation depth of the system, and the peak regulation depth would reach its limit at 96.35 MW and 40.83 MWh in the calculation cases, respectively. On this basis, the cooperative regulation of dual energy storage can further increase the capability of peak regulation and frequency modulation. The extreme point is that when the charge and discharge rates are both 3 MW, and meanwhile the peak clipping coefficient, a self-defined parameter, reaches 22.34 MW. Furthermore, an example calculation is carried out to verify the reliability of the design method of energy storage parameter. The specific parameters set include the charging and discharging rate of energy storage tank equipment is 61.67 MW, and its capacity is 10.64 MWh, and the charging and discharging rate of flywheel energy storage equipment is 3 MW. The example results confirmed that there was only a very small error between the set results and the calculation results. Finally, the thermal-electric load region has been drawn to contrast the key roles of dual energy storage systems, which indicates that the heat storage tank can be used for peak regulation and flywheel energy storage for frequency modulation. Overall, the parameter design method for dual energy storage can meet the engineering requirements and provide a new direction for the subsequent parameter design of thermal power unit coupled energy storage system.
- Open Access
Modification of the Maxwell–Wagner Heterogeneous Dielectric Model for Heterogeneous Polymers and Emulsions
In heterogeneous polymers and emulsions, the volume fraction of the discrete phase and the frequency of electromagnetic waves affect the accuracy of the dielectric model. The integral method was used to modify the Maxwell–Wagner (M–W) heterogeneous dielectric theory, and a new model for the complex dielectric constant of polymers and emulsions was established. The experimental data were compared with the results of the M–W heterogeneous dielectric integral modification model and other theoretical models for different frequencies and volume fractions of the discrete phase. We discovered that with a decreasing volume fraction of the discrete phase, the dominant frequency range of the integral modification model expanded. When the volume fraction of the discrete phase is 10%, the dominant frequency range reaches 3 GHz. When the volume fraction of the discrete phase is 1%, the dominant frequency range reaches 4 GHz. When the volume fraction of the discrete phase is 0.06%, the dominant frequency range of the real part reaches 9.6 GHz, and the dominant frequency range of the imaginary part reaches 7.2 GHz. These results verify the advantages of the M–W modification model, which provides a theoretical basis to study the dielectric properties of polymers and emulsions, as well as for microwave measurement.
Open AccessModification of the Maxwell–Wagner Heterogeneous Dielectric Model for Heterogeneous Polymers and Emulsions
In heterogeneous polymers and emulsions, the volume fraction of the discrete phase and the frequency of electromagnetic waves affect the accuracy of the dielectric model. The integral method was used to modify the Maxwell–Wagner (M–W) heterogeneous dielectric theory, and a new model for the complex dielectric constant of polymers and emulsions was established. The experimental data were compared with the results of the M–W heterogeneous dielectric integral modification model and other theoretical models for different frequencies and volume fractions of the discrete phase. We discovered that with a decreasing volume fraction of the discrete phase, the dominant frequency range of the integral modification model expanded. When the volume fraction of the discrete phase is 10%, the dominant frequency range reaches 3 GHz. When the volume fraction of the discrete phase is 1%, the dominant frequency range reaches 4 GHz. When the volume fraction of the discrete phase is 0.06%, the dominant frequency range of the real part reaches 9.6 GHz, and the dominant frequency range of the imaginary part reaches 7.2 GHz. These results verify the advantages of the M–W modification model, which provides a theoretical basis to study the dielectric properties of polymers and emulsions, as well as for microwave measurement.
- 21 February 2019
- Published by Springer Nature in The European Physical Journal E
- Vol. 42 (2) , 22
Dielectric properties of wet steam based on a double relaxation time model
The last stages of most steam turbines operate in wet steam, resulting in water erosion of the rotor blades and the reduction of turbine efficiency. Accurate measurement of steam wetness is...
- 21 February 2019
- Published by Springer Nature in The European Physical Journal E
- Vol. 42 (2) , 22
Dielectric properties of wet steam based on a double relaxation time model
The last stages of most steam turbines operate in wet steam, resulting in water erosion of the rotor blades and the reduction of turbine efficiency. Accurate measurement of steam wetness is...