Chun Yun Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chun Yun Zhang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Guofu Chen
School of Marine Science and Technology, Harbin Institute of Technology (Weihai), Weihai 264209, PR China
2 shared publications Fu Guo Liu
Harbin Institute of Technology (Weihai)
1 shared publicationFuguo Liu
School of Marine Science and Technology, Harbin Institute of Technology (Weihai), Weihai, People’s Republic of China
1 shared publicationJin Zhou
Harbin Institute of Technology (Weihai)
1 shared publicationYuan Yuan Wang
Harbin Institute of Technology (Weihai)
1 shared publicationYuanyuan Wang
School of Marine Science and Technology, Harbin Institute of Technology (Weihai), Weihai, People’s Republic of China
1 shared publication
Latest Publications
- 9 August 2020
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 27 (36) , 44995-45007
Detection of Prorocentrum minimum by hyperbranched rolling circle amplification coupled with lateral flow dipstick
A novel method referred to as hyperbranched rolling circle amplification (HRCA) coupled with lateral flow dipstick (LFD) (HRCA-LFD) here was developed for specific, sensitive, rapid, and simple detection of Prorocentrum minimum. HRCA-LFD relies on a padlock probe (PLP) consisting of a common ligation sequence, two terminal sequences that complement the target DNA, and a manually designed detection probe (LFD probe). The two terminal sequences of the PLP were designed against the species-specific sites of the large subunit ribosomal DNA (LSU rDNA) D1-D2 region of P. minimum. The optimum parameters for HRCA were as follows: PLP concentration of 20 pM, ligation time of 30 min, ligation temperature of 59 °C, enzymic digestion time of 105 min, amplification time of 45 min, and amplification temperature of 58 °C. The HRCA-LFD displaying high specificity could accurately distinguish P. minimum from other microalgae. The detection limit of HRCA-LFD was as low as 1.42 × 10−7 ng μL−1 for genomic DNA, 1.03 × 10−7 ng μL−1 (approximately 27 copies) for recombinant plasmid containing the inserted LSU rDNA D1-D2, and 0.17 cells for crude DNA extract of P. minimum, which was consistently 100 times more sensitive than regular PCR. Interfering test suggested that the performance of HRCA-LFD is stable and would not be affected by other non-target species. The HRCA-LFD results of field samples that are comparable with microscopic examination confirmed that the developed method is competent for detection of target cells in field samples. In conclusion, the developed HRCA-LFD exhibiting stable performance is specific, sensitive, and rapid, which provides a good alternative to traditional microscopic examination for the detection of P. minimum cells in field samples.
- 9 August 2020
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 27 (36) , 44995-45007
Detection of Prorocentrum minimum by hyperbranched rolling circle amplification coupled with lateral flow dipstick
A novel method referred to as hyperbranched rolling circle amplification (HRCA) coupled with lateral flow dipstick (LFD) (HRCA-LFD) here was developed for specific, sensitive, rapid, and simple detection of Prorocentrum minimum. HRCA-LFD relies on a padlock probe (PLP) consisting of a common ligation sequence, two terminal sequences that complement the target DNA, and a manually designed detection probe (LFD probe). The two terminal sequences of the PLP were designed against the species-specific sites of the large subunit ribosomal DNA (LSU rDNA) D1-D2 region of P. minimum. The optimum parameters for HRCA were as follows: PLP concentration of 20 pM, ligation time of 30 min, ligation temperature of 59 °C, enzymic digestion time of 105 min, amplification time of 45 min, and amplification temperature of 58 °C. The HRCA-LFD displaying high specificity could accurately distinguish P. minimum from other microalgae. The detection limit of HRCA-LFD was as low as 1.42 × 10−7 ng μL−1 for genomic DNA, 1.03 × 10−7 ng μL−1 (approximately 27 copies) for recombinant plasmid containing the inserted LSU rDNA D1-D2, and 0.17 cells for crude DNA extract of P. minimum, which was consistently 100 times more sensitive than regular PCR. Interfering test suggested that the performance of HRCA-LFD is stable and would not be affected by other non-target species. The HRCA-LFD results of field samples that are comparable with microscopic examination confirmed that the developed method is competent for detection of target cells in field samples. In conclusion, the developed HRCA-LFD exhibiting stable performance is specific, sensitive, and rapid, which provides a good alternative to traditional microscopic examination for the detection of P. minimum cells in field samples.
- 20 February 2019
- Published by Springer Nature in Journal of Applied Phycology
- Vol. 31 (4) , 2423-2436
Exponential rolling circle amplification coupled with lateral flow dipstick strips as a rapid and sensitive method for the field detection of Karlodinium veneficum
- 20 February 2019
- Published by Springer Nature in Journal of Applied Phycology
- Vol. 31 (4) , 2423-2436
Exponential rolling circle amplification coupled with lateral flow dipstick strips as a rapid and sensitive method for the field detection of Karlodinium veneficum