BJBjørn Erik Juel

Bjørn Erik Juel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bjørn Erik Juel has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Does Cognitive Load Affect Measures of Consciousness?

    by André Sevenius Nilsen, Johan Frederik Storm, Bjørn Erik Juel

    Background: Developing and testing methods for reliably measuring the state of consciousness of individuals is important for both basic research and clinical purposes. In recent years, several promising measures of consciousness, grounded in theoretical developments, have been proposed. However, the degrees to which these measures are affected by changes in brain activity that are not related to changes in the degree of consciousness has not been well tested. In this study, we examined whether several of these measures are modulated by the loading of cognitive resources. Methods: We recorded electroencephalography (EEG) from 12 participants in two conditions: (1) while passively attending to sensory stimuli related to the measures and (2) during increased cognitive load consisting of a demanding working memory task. We investigated whether a set of proposed objective EEG-based measures of consciousness differed between the passive and the cognitively demanding conditions. Results: The P300b event-related potential (sensitive to conscious awareness of deviance from an expected pattern in auditory stimuli) was significantly affected by concurrent performance on a working memory task, whereas various measures based on signal diversity of spontaneous and perturbed EEG were not. Conclusion: Because signal diversity-based measures of spontaneous or perturbed EEG are not sensitive to the degree of cognitive load, we suggest that these measures may be used in clinical situations where attention, sensory processing, or command following might be impaired.

  • Open Access

    EEG Lempel-Ziv complexity varies with sleep stage, but does not seem to track dream experience

    by Arnfinn Aamodt, André Sevenius Nilsen, Rune Markhus, Anikó Kusztor, Fatemeh HasanzadehMoghadam, Nils Kauppi, Benjamin Thürer, Johan Frederik Storm, Bjørn Erik Juel

    In a recent electroencephalography (EEG) sleep study inspired by complexity theories of consciousness, we found that multi-channel signal diversity progressively decreased from wakefulness to slow wave sleep, but failed to find any significant difference between dreaming and non-dreaming awakenings within the same sleep stage (NREM2). However, we did find that multi-channel Lempel-Ziv complexity (LZC) measured over the posterior cortex increased with more perceptual ratings of NREM2 dream experience along a thought-perceptual axis. In this follow-up study, we re-tested our previous findings, using a slightly different approach. Partial sleep-deprivation was followed by evening sleep experiments, with repeated awakenings and immediate dream reports. Participants reported whether they had been dreaming, and were asked to rate how diverse, vivid, perceptual, and thought-like the contents of their dreams were. High density (64 channel) EEG was recorded throughout the experiment, and mean single-channel LZC was calculated for each 30 s sleep epoch. LZC progressively decreased with depth of non-REM sleep. Surprisingly, estimated marginal mean LZC was slightly higher for NREM1 than for wakefulness, but the difference did not remain significant after adjusting for multiple comparisons. We found no significant difference in LZC between dream and non-dream awakenings, nor any significant relationship between LZC and subjective ratings of dream experience, within the same sleep stage (NREM2). The failure to reproduce our own previous finding of a positive correlation between posterior LZC and more perceptual dream experiences, or to find any other correlation between brain signal complexity and subjective experience within NREM2 sleep, raises the question of whether EEG LZC is really a reliable correlate of richness of experience as such, within the same sleep stage.


  • Open Access

    Capacity for consciousness under ketamine anaesthesia is selectively associated with activity in posteromedial cortex in rats

    by A Arena, B E Juel, R Comolatti, S Thon, J F Storm

    It remains unclear how specific cortical regions contribute to the brain’s overall capacity for consciousness. Clarifying this could help distinguish between theories of consciousness. Here, we investigate the association between markers of regionally specific (de)activation and the brain’s overall capacity for consciousness. We recorded electroencephalographic responses to cortical electrical stimulation in six rats and computed Perturbational Complexity Index state-transition (PCIST), which has been extensively validated as an index of the capacity for consciousness in humans. We also estimated the balance between activation and inhibition of specific cortical areas with the ratio between high and low frequency power from spontaneous electroencephalographic activity at each electrode. We repeated these measurements during wakefulness, and during two levels of ketamine anaesthesia: with the minimal dose needed to induce behavioural unresponsiveness and twice this dose. We found that PCIST was only slightly reduced from wakefulness to light ketamine anaesthesia, but dropped significantly with deeper anaesthesia. The high-dose effect was selectively associated with reduced high frequency/low frequency ratio in the posteromedial cortex, which strongly correlated with PCIST. Conversely, behavioural unresponsiveness induced by light ketamine anaesthesia was associated with similar spectral changes in frontal, but not posterior cortical regions. Thus, activity in the posteromedial cortex correlates with the capacity for consciousness, as assessed by PCIST, during different depths of ketamine anaesthesia, in rats, independently of behaviour. These results are discussed in relation to different theories of consciousness.


  • Open Access

    Changes in measures of consciousness during anaesthesia of one hemisphere (Wada test)

    by Sebastian Halder, Bjørn E Juel, André S Nilsen, Lashmi Venkat Raghavan, Johan F Storm


  • Open Access

    Proposed EEG measures of consciousness: a systematic, comparative review.

    by André S Nilsen, Bjørn Juel, Benjamin Thürer, Johan F. Storm

    Knowledge of which brain properties are required for consciousness is essential for improving clinical diagnostics and therapy as well as for investigating consciousness per se. The search for such properties has yielded many methods and measures for distinguishing conscious and apparently unconscious brain states. Here, we present a systematic literature review of 255 electroencephalography (EEG)-based measures of consciousness in humans. We show that measures based on signal diversity and event related potentials appear to be the most consistent. Specifically, spectral entropy, Lempel Ziv complexity, and spectral edge frequency, seem most practical, consistent, and reproducible. However, since most studies did not collect current or retrospective subjective reports about experiences, the states of consciousness were usually assessed from behavior. Hence, the ground truth about presence or absence of phenomenological experience in such cases is often uncertain, thus limiting the conclusions that can be drawn. We provide detailed overviews of general categories and specific measures of consciousness, to serve as a basis for further studies and future development.


  • Open Access

    Increased signal diversity/complexity of spontaneous EEG, but not evoked EEG responses, in ketamine-induced psychedelic state in humans

    by Nadine Farnes, Bjørn E. Juel, André S. Nilsen, Luis G. Romundstad, Johan F. Storm

    How and to what extent electrical brain activity reflects pharmacologically altered states and contents of consciousness, is not well understood. Therefore, we investigated whether measures of evoked and spontaneous electroencephalographic (EEG) signal diversity are altered by sub-anaesthetic levels of ketamine compared to normal wakefulness, and how these measures relate to subjective experience. High-density 62-channel EEG was used to record spontaneous brain activity and responses evoked by transcranial magnetic stimulation (TMS) in 10 healthy volunteers before and during administration of sub-anaesthetic doses of ketamine in an open-label within-subject design. Evoked signal diversity was assessed using the perturbational complexity index (PCI), calculated from EEG responses to TMS perturbations. Signal diversity of spontaneous EEG, with eyes open and eyes closed, was assessed by Lempel Ziv complexity (LZc), amplitude coalition entropy (ACE), and synchrony coalition entropy (SCE). Although no significant difference was found in TMS-evoked complexity (PCI) between the sub-anaesthetic ketamine condition and normal wakefulness, all measures of spontaneous EEG signal diversity (LZc, ACE, SCE) showed significantly increased values in the sub-anaesthetic ketamine condition. This increase in signal diversity correlated with subjective assessment of altered states of consciousness. Moreover, spontaneous signal diversity was significantly higher when participants had eyes open compared to eyes closed, both during normal wakefulness and during influence of sub-anaesthetic ketamine. The results suggest that PCI and spontaneous signal diversity may reflect distinct, complementary aspects of changes in brain properties related to altered states of consciousness: the brain’s capacity for information integration, assessed by PCI, might be indicative of the brain’s ability to sustain consciousness, while spontaneous complexity, as measured by EEG signal diversity, may be indicative of the complexity of conscious content. Thus, sub-anaesthetic ketamine may increase the complexity of the conscious content and the brain activity underlying it, while the level or general capacity for consciousness remains largely unaffected.


  • Open Access

    Validation of a new approach for distinguishing anesthetized from awake state in patients using directed transfer function applied to raw EEG

    by Bjørn E. Juel, Luis Romundstad, Johan F. Storm, Pål G. Larsson

    We test whether a measure based on the directed transfer function (DTF) calculated from short segments of electroencephalography (EEG) time-series can be used to monitor the state of the patients also during sevoflurane anesthesia as it can for patients undergoing propofol anesthesia. We collected and analyzed 25-channel EEG from 7 patients (3 females, ages 41–56 years) undergoing surgical anesthesia with sevoflurane, and quantified the sensor space directed connectivity for every 1-s epoch using DTF. The resulting connectivity parameters were compared to corresponding parameters from our previous study (n = 8, patients anesthetized with propofol and remifentanil, but otherwise using a similar protocol). Statistical comparisons between and within studies were done using permutation statistics, a data driven algorithm based on the DTF-parameters was employed to classify the epochs as coming from awake or anesthetized state. According to results of the permutation tests, DTF-parameter topographies were significantly different between the awake and anesthesia state at the group level. However, the topographies were not significantly different when comparing results computed from sevoflurane and propofol data, neither in the awake nor in anesthetized state. Optimizing the algorithm for simultaneously having high sensitivity and specificity in classification yielded an accuracy of 95.1% (SE = 0.96%), with sensitivity of 98.4% (SE = 0.80%) and specificity of 94.8% (SE = 0.10%). These findings indicate that the DTF changes in a similar manner when humans undergo general anesthesia caused by two distinct anesthetic agents with different molecular mechanisms of action.


  • Open Access

    Validation of a new approach for distinguishing anesthetized from awake state in patients using Directed Transfer Function applied to raw EEG

    by Bjoern Erik Juel, Luis Romundstad, Johan Frederik Storm, Paal Gunnar Larsson

    Aim: In a previous study, we found that the state of wakefulness in patients undergoing general anesthesia with propofol can effectively be monitored with high temporal resolution using an automatic measure of connectivity based on the Directed Transfer Function (DTF) calculated from short segments of electroencephalography (EEG) time-series. The study described here was designed to test whether the same measure can be used to monitor the state of the patients also during sevoflurane anesthesia. Methods: Twenty-five channel EEG recordings were collected from 8 patients undergoing surgical anesthesia with sevoflurane. The EEG data were segmented into one second epochs and labeled as awake or anesthetized in accordance with the clinician’s judgement, and the sensor space directed connectivity was quantified for every epoch using the DTF. The resulting DTF derived connectivity parameters were compared to corresponding parameters from our previous study using permutation statistics. A data driven classification algorithm was then employed to objectively classify the individual 1-second epochs as coming from awake or anesthetized state, using a leave-one-out cross-validation approach. The classifications were made for every epoch using the median DTF parameters across the five preceding 1-second EEG epochs. Results: The DTF derived connectivity parameters showed a significant difference between the awake and sevoflurane-induced general anesthesia at the group level (p0.05 for both comparisons). The classification algorithm reached a maximum accuracy of 96.8% (SE=0.63%). Optimizing the algorithm for simultaneously having high sensitivity and specificity in classification reduced the accuracy to 95.1% (SE=0.96%), with sensitivity of 98.4% (SE=0.80%) and specificity of 94.8% (SE=0.10%). Conclusion: These findings indicate that the DTF changes in a similar manner when humans undergo general anesthesia caused by two distinct anesthetic agents with different molecular mechanisms of action. This seems to support the idea that brain connectivity is related to the level of consciousness in humans, although further studies are needed to clarify whether our results may be contaminated by confounding factors.

  • Open Access

    Evaluating Approximations and Heuristic Measures of Integrated Information

    by André Sevenius Nilsen, Bjørn Erik Juel, William Marshall

    Integrated information theory (IIT) proposes a measure of integrated information, termed Phi (Φ), to capture the level of consciousness of a physical system in a given state. Unfortunately, calculating Φ itself is currently possible only for very small model systems and far from computable for the kinds of system typically associated with consciousness (brains). Here, we considered several proposed heuristic measures and computational approximations, some of which can be applied to larger systems, and tested if they correlate well with Φ. While these measures and approximations capture intuitions underlying IIT and some have had success in practical applications, it has not been shown that they actually quantify the type of integrated information specified by the latest version of IIT and, thus, whether they can be used to test the theory. In this study, we evaluated these approximations and heuristic measures considering how well they estimated the Φ values of model systems and not on the basis of practical or clinical considerations. To do this, we simulated networks consisting of 3–6 binary linear threshold nodes randomly connected with excitatory and inhibitory connections. For each system, we then constructed the system’s state transition probability matrix (TPM) and generated observed data over time from all possible initial conditions. We then calculated Φ, approximations to Φ, and measures based on state differentiation, coalition entropy, state uniqueness, and integrated information. Our findings suggest that Φ can be approximated closely in small binary systems by using one or more of the readily available approximations (r > 0.95) but without major reductions in computational demands. Furthermore, the maximum value of Φ across states (a state-independent quantity) correlated strongly with measures of signal complexity (LZ, rs = 0.722), decoder-based integrated information (Φ*, rs = 0.816), and state differentiation (D1, rs = 0.827). These measures could allow for the efficient estimation of a system’s capacity for high Φ or function as accurate predictors of low- (but not high-)Φ systems. While it is uncertain whether the results extend to larger systems or systems with other dynamics, we stress the importance that measures aimed at being practical alternatives to Φ be, at a minimum, rigorously tested in an environment where the ground truth can be established.


  • Open Access

    Evaluating Approximations and Heuristic Measures of Integrated Information

    by André Sevenius Nilsen, Bjørn Erik Juel, William Marshall, Johan Frederik Storm

    Integrated information theory (IIT) proposes a measure of integrated information (Φ) to capture the level of consciousness for a physical system in a given state. Unfortunately, calculating Φ itself is currently only possible for very small model systems, and far from computable for the kinds of systems typically associated with consciousness (brains). Here, we consider several proposed measures and computational approximations, some of which can be applied to larger systems, and test if they correlate well with Φ. While these measures and approximations capture intuitions underlying IIT and some have had success in practical applications, it has not been shown that they actually quantify the type of integrated information specified by the latest version of IIT. In this study, we evaluated these approximations and heuristic measures, based not on practical or clinical considerations, but rather based on how well they estimate the Φ values of model systems. To do this, we simulated networks consisting of 3–6 binary linear threshold nodes randomly connected with excitatory and inhibitory connections. For each system, we then constructed the system’s state transition probability matrix (TPM), as well as its state transition matrix (STM) over time for all possible initial states. From these matrices, we calculated, approximations to Φ, and measures based on state differentiation, state entropy, state uniqueness, and integrated information. All measures were correlated with Φ in a state dependent and state independent manner. Our findings suggest that Φ can be approximated closely in small binary systems by using one or more of the readily available approximations (r > 0.95), but without major reductions in computational demands. Furthermore, Φ correlated strongly with measures of signal complexity (LZ, rs = 0.722), decoder based integrated information (Φ*, rs = 0.816), and state differentiation (D1, rs = 0.827), on the system level (state independent). These measures could allow for efficient estimation of Φ on a group level, or as accurate predictors of low, but not high, Φ systems. While it’s uncertain whether the results extend to larger systems or systems with other dynamics, we stress the importance that measures aimed at being practical alternatives to Φ are at a minimum rigorously tested in an environment where the ground truth can be established.