Qiang Gao
Research Subjects
Qiang Gao has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
- Chengxiao Zhang
Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi’an 710062, China
11 shared publications Honglan Qi
Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi’an, China
10 shared publications- Honglan Qi
Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710062, People's Republic of China
10 shared publications Chengxiao Zhang
Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi’an, China
9 shared publicationsYonghua Zhang
Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710062, China; College of Chemistry and Chemical Engineering, and Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang 471934, China
5 shared publicationsJunjie Ai
Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710062, China
4 shared publications
Latest Publications
- 11 September 2025
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 41 (37) , 25556-25564
Spray Modification of Amino-Functionalized g-C3N4 Nanosheets on Screen-Printed Carbon Electrodes for the Electrochemiluminescence Immunoassay of SARS-CoV-2 N Protein Based on Coreactant Release from Polymersome Tags
A signal-on electrochemiluminescence (ECL) immunoassay was developed for the detection of the SARS-CoV-2 N protein using coreactant-encapsulated polymersomes as tags and a graphitic carbon nitride (g-C3N4) nanosheet-modified screen-printed carbon electrode (SPCE) as the working electrode. Poly(ether imide) (PEI)-modified g-C3N4 nanosheets were prepared through ultrasonic exfoliation followed by a supramolecular covalent scaffold strategy. Spray coating, a scalable deposition technique, was employed to modify the SPCE surface with g-C3N4 nanosheets. After thermal curing, the nanosheets adhered firmly to the electrode via binders in the carbon ink, yielding a stable modified SPCE. Immunosensors were constructed by immobilizing capture antibodies on the g-C3N4-modified SPCE. Potassium persulfate, (K2S2O8), the coreactant of g-C3N4, was encapsulated in polymersomes to prepare ECL tags, and probes were fabricated by conjugating SARS-CoV-2 N protein binding aptamers to these polymersomes. Upon recognition of the target protein and sandwich complexes formed on the immunosensor, the subsequent addition of Triton X-100 disrupted the polymersomes, releasing large amounts of K2S2O8, which markedly enhanced the ECL mission of g-C3N4 nanosheets. This amplification enabled highly sensitive detection of the SARS-CoV-2 N protein. These findings demonstrate that controlled release of encapsulated coreactants from polymersome tags is an effective strategy to trigger g-C3N4-based ECL emission for sensitive viral protein detection.
- 11 September 2025
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 41 (37) , 25556-25564
Spray Modification of Amino-Functionalized g-C3N4 Nanosheets on Screen-Printed Carbon Electrodes for the Electrochemiluminescence Immunoassay of SARS-CoV-2 N Protein Based on Coreactant Release from Polymersome Tags
A signal-on electrochemiluminescence (ECL) immunoassay was developed for the detection of the SARS-CoV-2 N protein using coreactant-encapsulated polymersomes as tags and a graphitic carbon nitride (g-C3N4) nanosheet-modified screen-printed carbon electrode (SPCE) as the working electrode. Poly(ether imide) (PEI)-modified g-C3N4 nanosheets were prepared through ultrasonic exfoliation followed by a supramolecular covalent scaffold strategy. Spray coating, a scalable deposition technique, was employed to modify the SPCE surface with g-C3N4 nanosheets. After thermal curing, the nanosheets adhered firmly to the electrode via binders in the carbon ink, yielding a stable modified SPCE. Immunosensors were constructed by immobilizing capture antibodies on the g-C3N4-modified SPCE. Potassium persulfate, (K2S2O8), the coreactant of g-C3N4, was encapsulated in polymersomes to prepare ECL tags, and probes were fabricated by conjugating SARS-CoV-2 N protein binding aptamers to these polymersomes. Upon recognition of the target protein and sandwich complexes formed on the immunosensor, the subsequent addition of Triton X-100 disrupted the polymersomes, releasing large amounts of K2S2O8, which markedly enhanced the ECL mission of g-C3N4 nanosheets. This amplification enabled highly sensitive detection of the SARS-CoV-2 N protein. These findings demonstrate that controlled release of encapsulated coreactants from polymersome tags is an effective strategy to trigger g-C3N4-based ECL emission for sensitive viral protein detection.
- 17 October 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (43) , 17345-17352
Highly Sensitive Electrochemiluminescence Biosensing Method for SARS-CoV-2 N Protein Incorporating the Micelle Probes of Quantum Dots and Dibenzoyl Peroxide Using the Screen-Printed Carbon Electrode Modified with a Carboxyl-Functionalized Graphene
Obtaining stable electrochemiluminescence (ECL) emissions from a hydrophobic luminophore in aqueous solutions and designing a method without the use of an exogenous coreactant are promising for ECL biosensing. Here, a highly sensitive signal-on ECL immunoassay for the SARS-CoV-2 N protein was developed using micelles as an ECL tag. The micelles were prepared by coencapsulating the luminophore hydrophobic CdSe/ZnS quantum dots and coreactant dibenzoyl peroxide within the hydrophobic core of micelles. The ECL probe was obtained by covalently bonding a SARS-CoV-2 N protein-binding aptamer onto the micelle surface. The construction of the immunosensor was initiated by the immobilization of the anti-SARS-CoV-2 N protein antibody onto the screen-printed carbon electrode (SPCE) with a -COOH-functionalized surface. The surface functionalization of SPCEs was achieved through paste-exfoliated graphene, which was modified with a -COOH group through supramolecular-covalent scaffolds on SPCE. Upon achieving sandwich complexes on the immunosensor, an efficient ECL signal response at -1.4 V versus Ag/AgCl was obtained in phosphate buffer solution. The ECL assay was used for the sensitive determination of SARS-CoV-2 N protein with the linear range from 0.01 to 50 ng mL-1, and the detection limit was 3.0 pg mL-1. The immunosensor showed good reproducibility and stability, and the ECL immunoassay was used to determine the SARS-CoV-2 N protein in serum samples. The proposed approach to obtain micelles is versatile for the preparation of stable ECL luminophores by using hydrophobic materials, and the strategy provides an alternative for ECL bioassays based on the coreactant route.
- 17 October 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (43) , 17345-17352
Highly Sensitive Electrochemiluminescence Biosensing Method for SARS-CoV-2 N Protein Incorporating the Micelle Probes of Quantum Dots and Dibenzoyl Peroxide Using the Screen-Printed Carbon Electrode Modified with a Carboxyl-Functionalized Graphene
Obtaining stable electrochemiluminescence (ECL) emissions from a hydrophobic luminophore in aqueous solutions and designing a method without the use of an exogenous coreactant are promising for ECL biosensing. Here, a highly sensitive signal-on ECL immunoassay for the SARS-CoV-2 N protein was developed using micelles as an ECL tag. The micelles were prepared by coencapsulating the luminophore hydrophobic CdSe/ZnS quantum dots and coreactant dibenzoyl peroxide within the hydrophobic core of micelles. The ECL probe was obtained by covalently bonding a SARS-CoV-2 N protein-binding aptamer onto the micelle surface. The construction of the immunosensor was initiated by the immobilization of the anti-SARS-CoV-2 N protein antibody onto the screen-printed carbon electrode (SPCE) with a -COOH-functionalized surface. The surface functionalization of SPCEs was achieved through paste-exfoliated graphene, which was modified with a -COOH group through supramolecular-covalent scaffolds on SPCE. Upon achieving sandwich complexes on the immunosensor, an efficient ECL signal response at -1.4 V versus Ag/AgCl was obtained in phosphate buffer solution. The ECL assay was used for the sensitive determination of SARS-CoV-2 N protein with the linear range from 0.01 to 50 ng mL-1, and the detection limit was 3.0 pg mL-1. The immunosensor showed good reproducibility and stability, and the ECL immunoassay was used to determine the SARS-CoV-2 N protein in serum samples. The proposed approach to obtain micelles is versatile for the preparation of stable ECL luminophores by using hydrophobic materials, and the strategy provides an alternative for ECL bioassays based on the coreactant route.
- Open Access
- 8 April 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (4) , 181
Electrogenerated Chemiluminescence Biosensor for Quantization of Matrix Metalloproteinase-3 in Serum via Target-Induced Cleavage of Oligopeptide
A highly sensitive and selective electrogenerated chemiluminescence (ECL) biosensor was developed for the determination of matrix metalloproteinase 3 (MMP-3) in serum via the target-induced cleavage of an oligopeptide. One ECL probe (named as Ir-peptide) was synthesized by covalently linking a new cyclometalated iridium(III) complex ([(3-pba)2Ir(bpy-COOH)](PF6)) (3-pba = 3-(2-pyridyl) benzaldehyde, bpy-COOH = 4′-methyl-2,2′-bipyridine-4-carboxylic acid) with an oligopeptide (CGVPLSLTMGKGGK). An ECL biosensor was fabricated by firstly casting Nafion and gold nanoparticles (AuNPs) on a glassy carbon electrode and then self-assembling both of the ECL probes, 6-mercapto-1-hexanol and zwitterionic peptide, on the electrode surface, from which the AuNPs could be used to amplify the ECL signal and Ir-peptide could serve as an ECL probe to detect the MMP-3. Thanks to the MMP-3-induced cleavage of the oligopeptide contributing to the decrease in ECL intensity and the amplification of the ECL signal using AuNPs, the ECL biosensor could selectively and sensitively quantify MMP-3 in the concentration range of 10–150 ng·mL−1 and with both a limit of quantification (26.7 ng·mL−1) and a limit of detection (8.0 ng·mL−1) via one-step recognition. In addition, the developed ECL biosensor showed good performance in the quantization of MMP-3 in serum samples, with a recovery of 92.6% ± 2.8%–105.6% ± 5.0%. An increased level of MMP-3 was found in the serum of rheumatoid arthritis patients compared with that of healthy people. This work provides a sensitive and selective biosensing method for the detection of MMP-3 in human serum, which is promising in the identification of patients with rheumatoid arthritis.
- 8 April 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (4) , 181
Open AccessElectrogenerated Chemiluminescence Biosensor for Quantization of Matrix Metalloproteinase-3 in Serum via Target-Induced Cleavage of Oligopeptide
A highly sensitive and selective electrogenerated chemiluminescence (ECL) biosensor was developed for the determination of matrix metalloproteinase 3 (MMP-3) in serum via the target-induced cleavage of an oligopeptide. One ECL probe (named as Ir-peptide) was synthesized by covalently linking a new cyclometalated iridium(III) complex ([(3-pba)2Ir(bpy-COOH)](PF6)) (3-pba = 3-(2-pyridyl) benzaldehyde, bpy-COOH = 4′-methyl-2,2′-bipyridine-4-carboxylic acid) with an oligopeptide (CGVPLSLTMGKGGK). An ECL biosensor was fabricated by firstly casting Nafion and gold nanoparticles (AuNPs) on a glassy carbon electrode and then self-assembling both of the ECL probes, 6-mercapto-1-hexanol and zwitterionic peptide, on the electrode surface, from which the AuNPs could be used to amplify the ECL signal and Ir-peptide could serve as an ECL probe to detect the MMP-3. Thanks to the MMP-3-induced cleavage of the oligopeptide contributing to the decrease in ECL intensity and the amplification of the ECL signal using AuNPs, the ECL biosensor could selectively and sensitively quantify MMP-3 in the concentration range of 10–150 ng·mL−1 and with both a limit of quantification (26.7 ng·mL−1) and a limit of detection (8.0 ng·mL−1) via one-step recognition. In addition, the developed ECL biosensor showed good performance in the quantization of MMP-3 in serum samples, with a recovery of 92.6% ± 2.8%–105.6% ± 5.0%. An increased level of MMP-3 was found in the serum of rheumatoid arthritis patients compared with that of healthy people. This work provides a sensitive and selective biosensing method for the detection of MMP-3 in human serum, which is promising in the identification of patients with rheumatoid arthritis.
- 17 February 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (3) , 1-10
Modified exfoliated graphene functionalized with carboxylic acid-group and thionine on a screen-printed carbon electrode as a platform for an electrochemical enzyme immunosensor
An enzyme immunoassay was developed based on the coulometric measurement of immunoglobulin M (IgM) against Hantaan viruses (HTNV) by using virus-like particles (VLPs) as recognition molecules. The surface functionalization of screen-printed carbon electrodes (SPCEs) was achieved through paste-exfoliated graphene that was modified with a COOH group and a thionine mediator through supramolecular-covalent scaffolds, on SPCEs by using the binder contained in the ink. After the covalent immobilization of the antibody, the sensor was used for the sandwich enzyme immunoassay of IgM against HTNV. By using HTNV VLPs as the second recognization molecules, the resulting sensor efficiently monitored the reaction of IgM against HTNV and anti-IgM antibody with high specificity. By attaching HTNV nucleocapsid protein antibody conjugate with horseradish peroxidase (HRP) onto VLPs, the signal response of the assay was derived from the coulometric measurement of H2O2 reduction mediated by thionine on the electrode surface after the application of a potential (− 0.2 V vs. Ag/AgCl). The ratio of charges measured before or after H2O2 addition was used to quantify IgM because these charges could be used as background charges or total charges, respectively. The ratio exhibited good agreement with IgM concentration within a range 0.1 to 1000 pg mL−1, and a detection limit of 0.06 pg mL−1 was obtained. The assay demonstrated high sensitivity and specificity toward HTNV-specific IgM in serum. Graphical abstract
- 17 February 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (3) , 1-10
Modified exfoliated graphene functionalized with carboxylic acid-group and thionine on a screen-printed carbon electrode as a platform for an electrochemical enzyme immunosensor
An enzyme immunoassay was developed based on the coulometric measurement of immunoglobulin M (IgM) against Hantaan viruses (HTNV) by using virus-like particles (VLPs) as recognition molecules. The surface functionalization of screen-printed carbon electrodes (SPCEs) was achieved through paste-exfoliated graphene that was modified with a COOH group and a thionine mediator through supramolecular-covalent scaffolds, on SPCEs by using the binder contained in the ink. After the covalent immobilization of the antibody, the sensor was used for the sandwich enzyme immunoassay of IgM against HTNV. By using HTNV VLPs as the second recognization molecules, the resulting sensor efficiently monitored the reaction of IgM against HTNV and anti-IgM antibody with high specificity. By attaching HTNV nucleocapsid protein antibody conjugate with horseradish peroxidase (HRP) onto VLPs, the signal response of the assay was derived from the coulometric measurement of H2O2 reduction mediated by thionine on the electrode surface after the application of a potential (− 0.2 V vs. Ag/AgCl). The ratio of charges measured before or after H2O2 addition was used to quantify IgM because these charges could be used as background charges or total charges, respectively. The ratio exhibited good agreement with IgM concentration within a range 0.1 to 1000 pg mL−1, and a detection limit of 0.06 pg mL−1 was obtained. The assay demonstrated high sensitivity and specificity toward HTNV-specific IgM in serum. Graphical abstract
- 31 January 2023
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1253, 340926
Washing-free electrogenerated chemiluminescence magnetic microbiosensors based on target assistant proximity hybridization for multiple protein biomarkers
- 31 January 2023
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1253, 340926
Washing-free electrogenerated chemiluminescence magnetic microbiosensors based on target assistant proximity hybridization for multiple protein biomarkers
- 27 May 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (12) , 8278-8284
Electrochemiluminescence Imaging for the Morphological and Quantitative Analysis of Living Cells under External Stimulation
In this work, a simple electrochemiluminescence (ECL) imaging method based on the cell shield of the ECL emission was developed for the morphological and quantitative analysis of living cells under external stimulation. ECL images of MCF-7 cells cultured on or captured at the glassy carbon electrode (GCE) surface in a solution of tris(2,2’-bipyridyl)-ruthenium (II)-tri-n-propylamine were recorded. Important morphological characteristics of living cells, including cell shape, cell area, average cell boundary, and junction distance between two adjacent cells, were directly obtained using the developed negative ECL imaging method. The ECL images revealed gradual morphological changes in cells on the GCE surface. During the course of H2O2 stimulation of cells on the GCE surface, cells shrunk, rounded up, disengaged from surrounding cells and finally detached from the electrode surface. During the course of electrical stimulation (0.8 V), the cells on the GCE surface exhibited aggregation as demonstrated by increases in the average cell boundary and decreases in the junction distance between two adjacent cells. Additionally, a quantitative method for the sensitive determination of MCF-7 cells with a limit of detection of 29 cells/mL was developed using the negative ECL imaging strategy. This work demonstrates that the proposed negative ECL imaging strategy is a promising approach to assess important morphological characteristics of living cells during the course of external stimulation and to obtain quantitative information of cell concentrations in solution.
- 27 May 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (12) , 8278-8284
Electrochemiluminescence Imaging for the Morphological and Quantitative Analysis of Living Cells under External Stimulation
In this work, a simple electrochemiluminescence (ECL) imaging method based on the cell shield of the ECL emission was developed for the morphological and quantitative analysis of living cells under external stimulation. ECL images of MCF-7 cells cultured on or captured at the glassy carbon electrode (GCE) surface in a solution of tris(2,2’-bipyridyl)-ruthenium (II)-tri-n-propylamine were recorded. Important morphological characteristics of living cells, including cell shape, cell area, average cell boundary, and junction distance between two adjacent cells, were directly obtained using the developed negative ECL imaging method. The ECL images revealed gradual morphological changes in cells on the GCE surface. During the course of H2O2 stimulation of cells on the GCE surface, cells shrunk, rounded up, disengaged from surrounding cells and finally detached from the electrode surface. During the course of electrical stimulation (0.8 V), the cells on the GCE surface exhibited aggregation as demonstrated by increases in the average cell boundary and decreases in the junction distance between two adjacent cells. Additionally, a quantitative method for the sensitive determination of MCF-7 cells with a limit of detection of 29 cells/mL was developed using the negative ECL imaging strategy. This work demonstrates that the proposed negative ECL imaging strategy is a promising approach to assess important morphological characteristics of living cells during the course of external stimulation and to obtain quantitative information of cell concentrations in solution.
- 6 December 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (1) , 884-891
Separation-Free Electrogenerated Chemiluminescence Immunoassay Incorporating Target Assistant Proximity Hybridization and Dynamically Competitive Hybridization of a DNA Signal Probe
A separation-free electrogenerated chemiluminescence (ECL) immunoassay for biomarkers has been developed incorporating target assistant proximity hybridization and dynamically competitive hybridization of DNA ECL signal probe, for the first time. In this work, the biomarkers of acute myocardial infarction including cardiac troponin I (cTnI), cardiac troponin T (cTnT), myoglobin (Myo) were chosen as the model proteins while corresponding antibody was utilized as recognition probe and the DNA5 tagged with ruthenium complex was chosen as an ECL signal probe (DNA5-Ru1). The biosensors were fabricated by covalently coupling the capture probe DNA1 onto the surface of a glassy carbon electrode and then a competitor ss-DNA2 was hybridized with DNA1. When the biosensor was incubated in the solution containing a target protein, the recognition probes (DNA3-Ab1 and DNA4-Ab2), DNA5-Ru1 and the coreactant tri-n-propylamine, the target protein was bounded with two antibodies of the recognition probes and thus induced the sufficient proximity hybridization of DNA3 with DNA1, DNA4 with DNA5-Ru1, and DNA5-Ru1 with DNA1 and unwinding the competitor DNA2 with DNA1, and ECL measurement was performed in separation-free format. It was found that the hybridization base number and length of DNA1 and a competing hybridization of DNA5-Ru1 with DNA2 for DNA1 have important effects. The developed ECL method showed much low detection limit of 0.4 pg/mL for cTnI, 0.5 pg/mL for cTnT, and 0.5 ng/mL for Myo. The fabricated biosensor exhibited stability and reusability. This work demonstrated that the developed ECL immunoassay is a promising separation-free and flexible strategy for quantitation of multiple proteins using one biosensor.
- 6 December 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (1) , 884-891
Separation-Free Electrogenerated Chemiluminescence Immunoassay Incorporating Target Assistant Proximity Hybridization and Dynamically Competitive Hybridization of a DNA Signal Probe
A separation-free electrogenerated chemiluminescence (ECL) immunoassay for biomarkers has been developed incorporating target assistant proximity hybridization and dynamically competitive hybridization of DNA ECL signal probe, for the first time. In this work, the biomarkers of acute myocardial infarction including cardiac troponin I (cTnI), cardiac troponin T (cTnT), myoglobin (Myo) were chosen as the model proteins while corresponding antibody was utilized as recognition probe and the DNA5 tagged with ruthenium complex was chosen as an ECL signal probe (DNA5-Ru1). The biosensors were fabricated by covalently coupling the capture probe DNA1 onto the surface of a glassy carbon electrode and then a competitor ss-DNA2 was hybridized with DNA1. When the biosensor was incubated in the solution containing a target protein, the recognition probes (DNA3-Ab1 and DNA4-Ab2), DNA5-Ru1 and the coreactant tri-n-propylamine, the target protein was bounded with two antibodies of the recognition probes and thus induced the sufficient proximity hybridization of DNA3 with DNA1, DNA4 with DNA5-Ru1, and DNA5-Ru1 with DNA1 and unwinding the competitor DNA2 with DNA1, and ECL measurement was performed in separation-free format. It was found that the hybridization base number and length of DNA1 and a competing hybridization of DNA5-Ru1 with DNA2 for DNA1 have important effects. The developed ECL method showed much low detection limit of 0.4 pg/mL for cTnI, 0.5 pg/mL for cTnT, and 0.5 ng/mL for Myo. The fabricated biosensor exhibited stability and reusability. This work demonstrated that the developed ECL immunoassay is a promising separation-free and flexible strategy for quantitation of multiple proteins using one biosensor.
- 10 June 2019
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 2 (7) , 3052-3058
Ultrasensitive Electrochemiluminescence Aptasensor for Assessment of Protein Heterogeneity in Small Cell Population
Development of sensitive method for assay of proteins secreted from small cell population is important for the assessment of cellular heterogeneity. Here, we developed an ultrasensitive electrochemiluminescence (ECL) aptasensor for secreted protein in small cell population of RAW 264.7 cells for cellular heterogeneity assessment. Tumor necrosis factor-alpha (TNF-α) was chosen as target secreted protein, and specific anti-TNF-α aptamer was chosen as molecule recognition element, while dichlorotris (1,10-phenanthroline) ruthenium(II) hydrate (Ru(phen)32+) was chosen as ECL signal compound. An ECL signal probe was prepared by combining aptamer, Ru(phen)32+ and graphene oxide (GO) through electrostatic interaction and π-π stacking interaction. An aptasensor was fabricated by self-assembly specific aptamer on gold nanoparticles modified electrode for the detection of TNF-α using sandwich assay. High sensitivity and good selectivity were obtained for TNF-α. Parallel analysis was conducted to detect TNF-α secreted by RAW 264.7 cells stimulated by either lipopolysaccharides (LPS) or lupeol for assessing the cell heterogeneity in small cell population and for estimating the intracellular signal transduction in inflammation. Compared to ELISA, our ECL method offers both high sensitivity and good accuracy. The distinct heterogeneity among the secreted protein in small cell population, for the first time, was observed and further correlated to the cell’s nature of cluster growth. The developed ECL method incorporating the amplification of nanomaterial and selectivity of aptamer is promising for sensitive and selective analysis of biomolecules in small cell population.
- 10 June 2019
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 2 (7) , 3052-3058
Ultrasensitive Electrochemiluminescence Aptasensor for Assessment of Protein Heterogeneity in Small Cell Population
Development of sensitive method for assay of proteins secreted from small cell population is important for the assessment of cellular heterogeneity. Here, we developed an ultrasensitive electrochemiluminescence (ECL) aptasensor for secreted protein in small cell population of RAW 264.7 cells for cellular heterogeneity assessment. Tumor necrosis factor-alpha (TNF-α) was chosen as target secreted protein, and specific anti-TNF-α aptamer was chosen as molecule recognition element, while dichlorotris (1,10-phenanthroline) ruthenium(II) hydrate (Ru(phen)32+) was chosen as ECL signal compound. An ECL signal probe was prepared by combining aptamer, Ru(phen)32+ and graphene oxide (GO) through electrostatic interaction and π-π stacking interaction. An aptasensor was fabricated by self-assembly specific aptamer on gold nanoparticles modified electrode for the detection of TNF-α using sandwich assay. High sensitivity and good selectivity were obtained for TNF-α. Parallel analysis was conducted to detect TNF-α secreted by RAW 264.7 cells stimulated by either lipopolysaccharides (LPS) or lupeol for assessing the cell heterogeneity in small cell population and for estimating the intracellular signal transduction in inflammation. Compared to ELISA, our ECL method offers both high sensitivity and good accuracy. The distinct heterogeneity among the secreted protein in small cell population, for the first time, was observed and further correlated to the cell’s nature of cluster growth. The developed ECL method incorporating the amplification of nanomaterial and selectivity of aptamer is promising for sensitive and selective analysis of biomolecules in small cell population.
- 11 February 2019
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 11 (9) , 8807-8817
Improvement of the Biocompatibility and Potential Stability of Chronically Implanted Electrodes Incorporating Coating Cell Membranes
The development of chronically implanted electrodes attracts much attention since these electrodes are much favorable for monitoring changes of neurotransmitters in brain science. The research of this field mainly was only focused on chemical modification to improve the potential stability, less on the biocompatibility. In this work, at the first time, we proposed the concept of cell-membrane electrodes based on a basic hypothesis using animal’s self-cell membrane to reduce animal exclusiveness (hyperacute rejection and chronic rejection). As a proof of concept, we first studied cell-membrane reference electrodes for chronically implanted electrodes. Red cell membrane (RCM) was extracted from the rat’s blood and coated on the chemically modified Ag/AgCl electrodes. It was found that ionic liquid (IL), 1-butyl-2, 3-dimethylimidazolium hexafluorophosphate (BDMI) showed a good performance rather than Nafion used as coating film for protection of silver chloride on Ag wire and support of the cell-membrane. Electrochemical impedance spectra supported that charge transfer resistance nearly kept constant before and after the electrodes were implanted into the rat’s brain tissues for 28 days. Immunohistochemical analysis of the implant sites in rat’s brain tissues indicated that the extent of glial scarring arising from the Ag/AgCl/BDMI/RCM electrodes was smaller than that of both Ag/AgCl/Nafion electrodes and Ag/AgCl/Nafion/RCM electrodes after 28 days of implantation. The RCM-coated Ag/AgCl/IL electrodes showed a relatively potential stability compared with that of RCM-noncoated Ag/AgCl/IL electrodes after 28 days of implantation. Additionally, the current-voltage curve demonstrated that the RCM-coated electrodes can be used as polarized electrodes. This work demonstrated that the RCM which was coated on the Ag/AgCl/IL electrodes can much improve the biocompatibility and potential stability of the RCM-noncoated Ag/AgCl/IL electrodes implanted in rat brain. The cell-membrane coated electrodes will serve as a lighthouse in guiding the design of chronically implanted electrodes for in vivo electrochemical detection.
- 11 February 2019
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 11 (9) , 8807-8817
Improvement of the Biocompatibility and Potential Stability of Chronically Implanted Electrodes Incorporating Coating Cell Membranes
The development of chronically implanted electrodes attracts much attention since these electrodes are much favorable for monitoring changes of neurotransmitters in brain science. The research of this field mainly was only focused on chemical modification to improve the potential stability, less on the biocompatibility. In this work, at the first time, we proposed the concept of cell-membrane electrodes based on a basic hypothesis using animal’s self-cell membrane to reduce animal exclusiveness (hyperacute rejection and chronic rejection). As a proof of concept, we first studied cell-membrane reference electrodes for chronically implanted electrodes. Red cell membrane (RCM) was extracted from the rat’s blood and coated on the chemically modified Ag/AgCl electrodes. It was found that ionic liquid (IL), 1-butyl-2, 3-dimethylimidazolium hexafluorophosphate (BDMI) showed a good performance rather than Nafion used as coating film for protection of silver chloride on Ag wire and support of the cell-membrane. Electrochemical impedance spectra supported that charge transfer resistance nearly kept constant before and after the electrodes were implanted into the rat’s brain tissues for 28 days. Immunohistochemical analysis of the implant sites in rat’s brain tissues indicated that the extent of glial scarring arising from the Ag/AgCl/BDMI/RCM electrodes was smaller than that of both Ag/AgCl/Nafion electrodes and Ag/AgCl/Nafion/RCM electrodes after 28 days of implantation. The RCM-coated Ag/AgCl/IL electrodes showed a relatively potential stability compared with that of RCM-noncoated Ag/AgCl/IL electrodes after 28 days of implantation. Additionally, the current-voltage curve demonstrated that the RCM-coated electrodes can be used as polarized electrodes. This work demonstrated that the RCM which was coated on the Ag/AgCl/IL electrodes can much improve the biocompatibility and potential stability of the RCM-noncoated Ag/AgCl/IL electrodes implanted in rat brain. The cell-membrane coated electrodes will serve as a lighthouse in guiding the design of chronically implanted electrodes for in vivo electrochemical detection.
- 1 February 2019
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 126, 255-260
Combining 3D graphene-like screen-printed carbon electrode with methylene blue-loaded liposomal nanoprobes for phospholipase A2 detection
- 1 February 2019
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 126, 255-260
Combining 3D graphene-like screen-printed carbon electrode with methylene blue-loaded liposomal nanoprobes for phospholipase A2 detection