JSJakub Sikorski

Jakub Sikorski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jakub Sikorski has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Field Model Identification and Control of a Mobile Electromagnet for Remote Actuation of Soft Robots

    by Alessandro Riccardi, Guilherme P. Furtado, Jakub Sikorski, Marilena Vendittelli, Sarthak Misra

    The actuation of miniaturized robots through external magnetic fields has great potential for medical applications. The controllability properties of the miniaturized robots are affected by magnetic field generation modality. In this work, the magnetic field of a mobile electromagnet, notably capable to generate a desired magnetic field in large 3D workspaces, has been identified first. Then, a control model of the field generation system has been developed to produce a desired magnetic field designed to generate a locomotion gait in a legged miniaturized robot. Preliminary experiments prove the viability of the approach.


  • MagNeed – Needle-Shaped Electromagnets for Localized Actuation Within Compact Workspaces

    by Juan J. Huaroto, Michiel Richter, Mafalda Malafaia, Jayoung Kim, Chang-Sei Kim, Jong-Oh Park, Jakub Sikorski, Sarthak Misra

    Electromagnetic actuation of micro-/milli-sized agents has traditionally relied on large electromagnets positioned at considerable distances from the agents. As a result, the electromagnets consume kilowatts of power to overcome the limited generation of magnetic field gradients. Miniaturized electromagnets offer an alternative approach for reducing power consumption via localized actuation of micro-/milli-sized agents. Typically, the generation of magnetic field gradients in the vicinity of a miniaturized electromagnet is comparable with traditional electromagnetic actuation systems. Miniaturized electromagnets can be positioned near target sites in microfluidic channels or ex vivo vasculatures. Thereby, localized trapping and actuation of magnetic micro-/milli-sized agents are carried out. This study introduces MagNeed – an electromagnetic actuation system composed of three needle-shaped electromagnets (NSEs). MagNeed can determine compact workspaces by positioning the NSEs at different spatial configurations. Each NSE generates magnetic field gradients (up to 3.5 T/m at 5 mm from the NSE tip axis) while keeping a maximum power consumption (0.5 W) and temperature ( $< $ 42 $^{\circ}$ C). MagNeed is complemented by a framework that reconstructs the pose of the NSEs. Experiments test MagNeed and framework on a transparent Teflon tube (5 mm inner diameter). MagNeed demonstrates localized trapping and actuation of a 1 mm NdFeB bead against a flow of water and silica gel particles (1–3 mm diameter).


  • Magnetic Soft Helical Manipulators with Local Dipole Interactions for Flexibility and Forces

    by Michiel Richter, Mert Kaya, Jakub Sikorski, Leon Abelmann, Venkatasubramanian Kalpathy Venkiteswaran, Sarthak Misra

    Magnetic continuum manipulators (MCMs) are a class of continuum robots that can be actuated without direct contact by an external magnetic field. MCMs operating in confined workspaces, such as those targeting medical applications, require flexible magnetic structures that contain combinations of magnetic components and polymers to navigate long and tortuous paths. In cylindrical MCM designs, a significant trade-off exists between magnetic moment and bending flexibility as the ratio between length and diameter decreases. In this study, we propose a new MCM design framework that enables increasing diameter without compromising on flexibility and magnetic moment. Magnetic soft composite helices constitute bending regions of the MCM and are separated by permanent ring magnets. Local dipole interactions between the permanent magnets can reduce bending stiffness, depending on their size and spacing. For the particular segment geometry presented herein, the local dipole interactions result in a 31% increase in angular deflection of composite helices inside an external magnetic field, compared to helices without local interactions. In addition, we demonstrate fabrication, maneuverability, and example applications of a multisegment MCM in a phantom of the abdominal aorta, such as passing contrast dye and guidewires.


  • Design, Sensing, and Control of a Magnetic Compliant Continuum Manipulator

    by Theodosia Lourdes Thomas, Jakub Sikorski, G. K. Ananthasuresh, Venkatasubramanian Kalpathy Venkiteswaran, Sarthak Misra

    Continuum manipulators coupled with magnetic actuation have great potential as steerable instruments for diverse surgical applications. They can be maneuvered inside the human body to reach difficult-to-access surgical sites with contactless actuation. This paper presents a new design of a compliant continuum manipulator of diameter 3 mm and length 70 mm, capable of spatial bending under magnetic actuation. A quasi-static model is developed to estimate the 3D motion of the manipulator. Experiments report an overall mean error in whole shape estimation of the manipulator between the model and the ground truth of 1.7 mm and 4.8 mm, when suspended vertically and horizontally from its base, respectively. Furthermore, fiber Bragg grating (FBG) sensors are integrated with the manipulator to enable shape sensing. Closed-loop control is demonstrated to trace different trajectories with the tip of the manipulator. A square trajectory and a straight line trajectory are generated with an average error in tip position of 4.1 mm between the desired and estimated positions. The potential of the manipulator as a steerable instrument is validated by maneuvering it inside phantoms of a bifurcating arterial system and a heart with visual guidance from a miniature camera.


  • Open Access

    A Flexible Catheter System for Ultrasound-Guided Magnetic Projectile Delivery

    by Jakub Sikorski, Christoff Marthinus Heunis, Rafic Obeid, Venkatasubramanian Kalpathy Venkiteswaran, Sarthak Misra

    Magnetic actuation is a versatiletechnology, widely applied in medical robotics for noncontact steering of flexible instruments and untethered agents. In this article, we exploit the benefits of this technology by developing a magnetically actuated flexible catheter capable of the controlled ejection and retrieval of an untethered magnetic capsule. The catheter is actuated by the advanced robotics for magnetic manipulation system. The scanning ultrasound is used for 3-D shape reconstruction of the catheter, with a mean error of 0.37 mm. We use a closed-loop position controller to steer the catheter, reporting a mean error of 0.82 mm. We develop a dynamic model of the capsule and use it to predict the trajectory of the projectile. We demonstrate the targeting of the capsule utilizing the null-space of the catheter actuation (mean residual tip displacement of 0.8 mm). Finally, we perform a delivery of a capsule to and retrieval from a target inaccessible for the catheter tip, demonstrating the capability of our instrument to reach challenging locations.


  • Open Access

    RobUSt–An Autonomous Robotic Ultrasound System for Medical Imaging

    by Filip Suligoj, Christoff M. Heunis, Jakub Sikorski, Sarthak Misra

    Medical ultrasound (US) systems are widely used for the diagnosis of internal tissues. However, there are challenges associated with acquiring and interpreting US images, such as incorrect US probe placement and limited available spatial information. In this study, we expand the capabilities of medical US imaging using a robotic framework with a high level of autonomy. A 3D camera is used to capture the surface of an anthropomorphic phantom as a point cloud, which is then used for path planning and navigation of the US probe. Robotic positioning of the probe is realised using an impedance controller, which maintains stable contact with the surface during US scanning and compensates for uneven and moving surfaces. Robotic US positioning accuracy is measured to be 1.19± 0.76mm. The mean force along US probe z-direction is measured to be 6.11±1.18N on static surfaces and 6.63±2.18N on moving surfaces. Overall lowest measured force of 1.58N demonstrates constant probe-to-surface contact during scanning. Acquired US images are used for the 3D reconstruction and multi-modal visualization of the surface and the inner anatomical structures of the phantom. Finally, K-means clustering is used to segment different tissues. Best segmentation accuracy of the jugular vein according to Jaccard similarity coefficient is measured to be 0.89. With such an accuracy, this system could substantially improve autonomous US acquisition and enhance the diagnostic confidence of clinicians.


  • MILiMAC: Flexible Catheter With Miniaturized Electromagnets as a Small-Footprint System for Microrobotic Tasks

    by Jakub Sikorski, Sumit Mohanty, Sarthak Misra

    Advancements in medical microrobotics have given rise to an abundance of agents capable of localised interaction with human body in small scales. Nevertheless, clinically-relevant applications of this technology are still limited by the auxiliary infrastructure required for actuation of micro-agents. In this letter, we approach this challenge. Using finite-element analysis, we show that miniaturization of electromagnets can be used to create systems capable of providing magnetic forces adequate for micro-agent steering, while retaining small footprint and power consumption. We use these observations to create MILiMAC (Microrobotic Infrastructure Loaded into Magnetically-Actuated Catheter). MILiMAC is a flexible catheter employing three miniaturized electromagnets to provide localized magnetic actuation at the deeply-seated microsurgery site. We test our approach in a proof-of-concept study deploying MILiMAC inside a test platform to deliver and steer a 600 [ $\boldsymbol{\mu }$ m] ferromagnetic microbead. The bead is steered along a set of user-defined trajectories using closed-loop position control. Across all trajectories the best performance metrics are the mean error of 0.41 [mm] and the steady-state error of 0.27 [mm].


  • The ARMM System - Autonomous Steering of Magnetically-Actuated Catheters: Towards Endovascular Applications

    by Christoff Marthinus Heunis, Yannik P. Wotte, Jakub Sikorski, Guilherme Phillips Furtado, Sarthak Misra

    Robot-assisted technologies are increasingly being developed for their use in endovascular surgery. These technologies can aid clinicians in providing higher precision, increased accuracy, and reproducibility. This paper further extends the clinical feasibility of an autonomous system designed to provide assistance during endovascular procedures. We develop a control strategy that allows a user to guide a magnetic catheter to target sites. The system handles the full synchronization of co-operating manipulators that both actuate a clinical tool. The catheter is positioned using magnetic actuation and proportional-integral (PI) control in conjunction with real-time ultrasound images. Our results indicate an average error between the tracked catheter tip and target positions of 2.09±0.49 mm. We expect that our system will provide a step towards collaborative manipulators employing mobile electromagnets, and possibly improve autonomous catheterization procedures within endovascular surgeries.


  • Bio-Inspired Terrestrial Motion of Magnetic Soft Millirobots

    by Venkatasubramanian Kalpathy Venkiteswaran, Luis Fernando Pena Samaniego, Jakub Sikorski, Sarthak Misra