Wei Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wei Li has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Guang-Zhong Yang
Shanghai Key Laboratory of Flexible Medical Robotics, Tongren Hospital, Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China
2 shared publications - Anzhu Gao
Shanghai Jiao Tong University
1 shared publication Benny Lo
Hamlyn Centre for Robotic Surgery, Imperial College London, London, U.K.
1 shared publicationCarlo A. Seneci
1 shared publication- Dandan Zhang
Department of Bioengineering, Imperial College London, London, UK
1 shared publication - Daniel Bautista-Salinas
The Hamlyn Centre for Robotic Surgery Institute of Global Health and Innovation Imperial College London South Kensington Campus London SW7 2AZ UK
1 shared publication
Latest Publications
- Open Access
- 1 December 2021
- Published by Elsevier in International Journal of Cardiology Congenital Heart Disease
- Vol. 6, 100285
ASD or PFO: State-of-the-art echocardiography says it all
- 1 December 2021
- Published by Elsevier in International Journal of Cardiology Congenital Heart Disease
- Vol. 6, 100285
Open AccessASD or PFO: State-of-the-art echocardiography says it all
- 17 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 3 (1) , 257-260
Towards a Snake-Like Flexible Robot for Endoscopic Submucosal Dissection
The advance of flexible robots enables a more efficient and safer way to perform endoscopic submucosal dissection surgery. The robot should be flexible enough for easy insertion and able to maintain a rigid shape to transmit the forces applied on instrumentation during the operation. This paper presents a snake-like flexible endoscope design which consists of an active snake robot and a passive flexible body. The active section is composed of metal printed spring-like joints actuated by tendons arranged in a novel fashion. To analyse the performance and clinical feasibility of the proposed flexible robot, Finite Element Analysis, workspace analysis, path following accuracy and force test have been performed. The results have shown that the robot can reach a minimum retro-flex bending radius of 23 mm and the distance errors of each joint when advancing along a simulated colon path are analysed. Validation of the proposed robot demonstrates its potential for ESD surgeries.
- 17 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 3 (1) , 257-260
Towards a Snake-Like Flexible Robot for Endoscopic Submucosal Dissection
The advance of flexible robots enables a more efficient and safer way to perform endoscopic submucosal dissection surgery. The robot should be flexible enough for easy insertion and able to maintain a rigid shape to transmit the forces applied on instrumentation during the operation. This paper presents a snake-like flexible endoscope design which consists of an active snake robot and a passive flexible body. The active section is composed of metal printed spring-like joints actuated by tendons arranged in a novel fashion. To analyse the performance and clinical feasibility of the proposed flexible robot, Finite Element Analysis, workspace analysis, path following accuracy and force test have been performed. The results have shown that the robot can reach a minimum retro-flex bending radius of 23 mm and the distance errors of each joint when advancing along a simulated colon path are analysed. Validation of the proposed robot demonstrates its potential for ESD surgeries.
- Open Access
- 11 October 2019
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 15 (1) , 15-25
A microsurgical robot research platform for robot-assisted microsurgery research and training
Purpose: Ocular surgery, ear, nose and throat surgery and neurosurgery are typical types of microsurgery. A versatile training platform can assist microsurgical skills development and accelerate the uptake of robot-assisted microsurgery (RAMS). However, the currently available platforms are mainly designed for macro-scale minimally invasive surgery. There is a need to develop a dedicated microsurgical robot research platform for both research and clinical training. Methods: A microsurgical robot research platform (MRRP) is introduced in this paper. The hardware system includes a slave robot with bimanual manipulators, two master controllers and a vision system. It is flexible to support multiple microsurgical tools. The software architecture is developed based on the robot operating system, which is extensible at high-level control. The selection of master–slave mapping strategy was explored, while comparisons were made between different interfaces. Results: Experimental verification was conducted based on two microsurgical tasks for training evaluation, i.e. trajectory following and targeting. User study results indicated that the proposed hybrid interface is more effective than the traditional approach in terms of frequency of clutching, task completion time and ease of control. Conclusion: Results indicated that the MRRP can be utilized for microsurgical skills training, since motion kinematic data and vision data can provide objective means of verification and scoring. The proposed system can further be used for verifying high-level control algorithms and task automation for RAMS research.
- 11 October 2019
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 15 (1) , 15-25
Open AccessA microsurgical robot research platform for robot-assisted microsurgery research and training
Purpose: Ocular surgery, ear, nose and throat surgery and neurosurgery are typical types of microsurgery. A versatile training platform can assist microsurgical skills development and accelerate the uptake of robot-assisted microsurgery (RAMS). However, the currently available platforms are mainly designed for macro-scale minimally invasive surgery. There is a need to develop a dedicated microsurgical robot research platform for both research and clinical training. Methods: A microsurgical robot research platform (MRRP) is introduced in this paper. The hardware system includes a slave robot with bimanual manipulators, two master controllers and a vision system. It is flexible to support multiple microsurgical tools. The software architecture is developed based on the robot operating system, which is extensible at high-level control. The selection of master–slave mapping strategy was explored, while comparisons were made between different interfaces. Results: Experimental verification was conducted based on two microsurgical tasks for training evaluation, i.e. trajectory following and targeting. User study results indicated that the proposed hybrid interface is more effective than the traditional approach in terms of frequency of clutching, task completion time and ease of control. Conclusion: Results indicated that the MRRP can be utilized for microsurgical skills training, since motion kinematic data and vision data can provide objective means of verification and scoring. The proposed system can further be used for verifying high-level control algorithms and task automation for RAMS research.
- 24 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 24 (2) , 517-526
Design, Fabrication, and Testing a Semiautomatic Sewing Device for Personalized Stent Graft Manufacturing
- 24 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 24 (2) , 517-526
Design, Fabrication, and Testing a Semiautomatic Sewing Device for Personalized Stent Graft Manufacturing