Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Somayeh Fardindoost has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Electrochemical and Surface-Enhanced Raman Spectroscopy-Based Biosensing Strategies for Wound Infection Detection: Recent Advances and Applications in Point-of-Care Diagnostics

    by Rolla Mohamed, Abbas Sabahi, Somayeh Fardindoost, Mina Hoorfar

    The growing prevalence of chronic wound infections presents a major global healthcare challenge due to delayed healing, prolonged hospitalization, and increased rates of limb amputation. Conventional diagnostic approaches, including clinical assessment, microbiological culture, and laboratory-based analyses, are often limited by subjective interpretation, delayed turnaround times, invasive sampling, and an inability to continuously monitor the dynamic wound microenvironment. Because wound infection involves changes in both host physiology and microbial activity, reliance on a single biomarker may not adequately characterize wound status, highlighting the potential of multimodal point-of-care diagnostic platforms. Recent advances in wearable biosensors, surface-enhanced Raman spectroscopy (SERS), nanomaterials, and artificial intelligence (AI) have supported the development of multimodal approaches for monitoring complementary host- and pathogen-derived biomarkers to facilitate rapid, non-invasive, and continuous wound infection assessment. This review examines selected multimodal biosensing approaches for wound infection detection, with a focus on electrochemical biosensors, SERS, and AI-assisted data analytics within point-of-care diagnostic frameworks. The review discusses (1) key wound infection biomarkers and the fundamental principles of electrochemical and SERS-based sensing; (2) recent developments in multimodal biosensing platforms, advanced plasmonic materials, and AI-assisted data interpretation and multimodal data fusion; and (3) current challenges and future opportunities for the clinical translation of point-of-care wound diagnostics. By combining complementary sensing modalities with AI-driven data analytics, these approaches may support earlier infection detection, continuous non-invasive monitoring, personalized wound management, and more informed clinical decision-making.

  • Optimization of Breath VOC Sensors Using Porous Anti-Humidity Membranes and Machine Learning-Based Humidity Prediction

    by Jung Yoon Sarah An, Somayeh Fardindoost, Mina Hoorfar

    Breath-sensing technologies offer a non-invasive approach for detecting biomarkers in exhaled breath, however, high moisture content in exhaled air often compromises sensor–analyte interactions, reducing sensitivity, selectivity, and reliability. In this study, porous polydimethylsiloxane (PDMS) and UiO-66@PDMS anti-humidity membranes were fabricated via a sugar-cube templating method and integrated with a commercial ethanol-sensitive Figaro gas sensor to systematically enhance sensor performance under high-humidity conditions. The sensors were tested with ethanol, acetone, and their mixture under dry (20–30% RH) and humid (70–80% RH, up to >90% RH) conditions. While porous PDMS membranes mitigated humidity effects, they significantly reduced analyte sensitivity. In contrast, UiO-66@PDMS membranes maintained high sensitivity to ethanol, achieving a 52% response to 50 ppm ethanol under humid conditions, outperforming the membrane-free sensor (41% response) and demonstrating enhanced selectivity and stability. To further improve sensor reliability, five supervised regression models—Gaussian process, random forest (RF), RF with hyperparameter optimization, k-nearest neighbors (KNN), and support vector machine (SVM) with hyperparameter optimization—were trained to predict relative humidity from sensor outputs. The RF model with hyperparameter optimization achieved 98% accuracy and R² = 0.998, providing robust correction of humidity-induced interference. Pearson correlation analysis showed a reduction from 0.708 to 0.190 after membrane integration, quantitatively confirming effective humidity mitigation. These results demonstrate that combining MOF-based anti-humidity membranes with machine learning enables reliable, accurate, and reproducible VOC detection in humid environments, offering a practical and scalable strategy for next-generation breath-based sensors.


  • (undefined)

    by Mostafa Azimzadeh, Patricia Khashayar, Marziyeh Mousazadeh, Maryam Daneshpour, Mohammad Rostami, David R. Goodlett, Karim Manji, Somayeh Fardindoost, Mohsen Akbari, Mina Hoorfar


  • Open Access

    Volatile organic compounds (VOCs) detection for the identification of bacterial infections in clinical wound samples

    by Mostafa Azimzadeh, Patricia Khashayar, Marziyeh Mousazadeh, Maryam Daneshpour, Mohammad Rostami, David R. Goodlett, Karim Manji, Somayeh Fardindoost, Mohsen Akbari, Mina Hoorfar


  • Open Access

    A Droplet-Based Microfluidic Impedance Flow Cytometer for Detection of Micropollutants in Water

    by Mohammadreza Aghel, Somayeh Fardindoost, Nishat Tasnim, Mina Hoorfar

    Microplastics as micropollutants are widely spread in aquatic areas that can have a toxic effect on aquatic life. To reduce the potential risk they pose, it is essential to detect the microplastics and the source of the contamination of the environment. Here, we designed and developed a droplet-based microfluidic impedance flow cytometer for in situ detection of microplastics in water. Impedance spectroscopy enables the direct measurement of the electrical features of microplastics as they move in water, allowing for sizing and identification of concentration. To show the feasibility of the developed method, pure and functionalized polystyrene beads ranging from 500 nm to 6 μm in four size groups and different concentrations were used. Focusing on three different frequencies (4.4 MHz, 11 MHz, and 22.5 MHz), the changes in the signal phase at frequencies of 4.4 MHz and 11 MHz are a strong indicator of microplastic presence. In addition, the functionalized microplastics showed different magnitudes of the measured signal phase than the pure ones. A k-nearest neighbors classification model demonstrated our developed system’s impressive 97.4% sensitivity in accurately identifying microplastics based on concentration. The equivalent circuit model revealed that the double-layer capacity of water droplets is significantly impacted by the presence of the microplastics. Our findings show the potential of droplet-based microfluidic impedance flow cytometry as a practical method for detecting microplastics in water.


  • Open Access

    Exhaled Breath Analysis for Diabetes Diagnosis and Monitoring: Relevance, Challenges and Possibilities

    by Kaushiki Dixit, Somayeh Fardindoost, Adithya Ravishankara, Nishat Tasnim, Mina Hoorfar

    With the global population prevalence of diabetes surpassing 463 million cases in 2019 and diabetes leading to millions of deaths each year, there is a critical need for feasible, rapid, and non-invasive methodologies for continuous blood glucose monitoring in contrast to the current procedures that are either invasive, complicated, or expensive. Breath analysis is a viable methodology for non-invasive diabetes management owing to its potential for multiple disease diagnoses, the nominal requirement of sample processing, and immense sample accessibility; however, the development of functional commercial sensors is challenging due to the low concentration of volatile organic compounds (VOCs) present in exhaled breath and the confounding factors influencing the exhaled breath profile. Given the complexity of the topic and the skyrocketing spread of diabetes, a multifarious review of exhaled breath analysis for diabetes monitoring is essential to track the technological progress in the field and comprehend the obstacles in developing a breath analysis-based diabetes management system. In this review, we consolidate the relevance of exhaled breath analysis through a critical assessment of current technologies and recent advancements in sensing methods to address the shortcomings associated with blood glucose monitoring. We provide a detailed assessment of the intricacies involved in the development of non-invasive diabetes monitoring devices. In addition, we spotlight the need to consider breath biomarker clusters as opposed to standalone biomarkers for the clinical applicability of exhaled breath monitoring. We present potential VOC clusters suitable for diabetes management and highlight the recent buildout of breath sensing methodologies, focusing on novel sensing materials and transduction mechanisms. Finally, we portray a multifaceted comparison of exhaled breath analysis for diabetes monitoring and highlight remaining challenges on the path to realizing breath analysis as a non-invasive healthcare approach.


  • Open Access

    A Novel Approach in Sorting Chirality Species of Single-Wall Carbon Nanotubes Based on an Aqueous Two-Phase System of Polymer-Salt

    by Marziyeh Karandish, Somayeh Fardindoost, Gholamreza Pazuki

    Sorting of distinct (n, m) chirality species of single-wall carbon nanotubes (SWCNTs) is essential for progress in technical applications in the field of electronic and optic devices. The purpose of this study is to investigate the isolation of single-wall carbon nanotubes based on diameters/chirality in a polymer-salt (polyethylene glycol and sodium citrate) aqueous two-phase system (ATPS) a substitute for common polymer-polymer (polyethylene glycol and dextran) system. The ATPS based on polymer-salt used instead of the common polymer-polymer system due to low viscosity, reduced surface tension, and lower cost of sodium citrate compared to the dextran. For this purpose, the ratio of concentrations of polyethylene glycol to sodium citrate as well as the effect of temperature on the isolation are both investigated and the selectivity and the recovery estimated approximately. The absorbance spectra from both top and bottom phases at different polymer and salt contents and at different temperatures show that by using this system in optimal conditions of polymer to salt ratio of 2:1 at temperature of 20 °C, a suitable separation of nanotubes with 85% yield of the chiral groups of 9 and 10 can be obtained.