Marwan Mahmoud
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marwan Mahmoud has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Kamaruzzaman Sopian
Mechanical Engineering Department, Universiti Teknologi Petronas, Seri Iskandar, Malaysia
12 shared publications - Tamer Khatib
An-Najah National University
11 shared publications Azah Mohamed
Department of Electrical, Electronic & System Engineering, Faculty of Engineering & Built Environment , Universiti Kebangsaan Malaysia , Bangi , Selangor , Malaysia
8 shared publicationsA. Mohamed
Institute of Networked & Embedded Systems/Lakeside Labs, Alpen-Adria-Universität Klagenfurt, Klagenfurt, Austria
3 shared publications- Imad Ibrik
An-Najah National University
3 shared publications - Moien Ali Omar
Electrical Engineering Department, Faculty of Engineering, An-Najah National University, Nablus P400, Palestine
3 shared publications
Latest Publications
- Open Access
- 8 April 2021
- Published by Center of Biomass and Renewable Energy Scientia Academy in International Journal of Renewable Energy Development
- Vol. 10 (4) , 687-697
Improvement Approach for Matching PV-array and Inverter of Grid Connected PV Systems Verified by a Case Study
Correct matching between PV array and inverter improves the inverter efficiency, increases the annual produced energy, decreases the clipping losses of the inverter, and prevent to a large extent the inverter frequent shut downs during clear sunny days of high solar radiation and low ambient temperature. Therefore, this paper presents a new methodology for selecting the appropriate peak power of the PV array with respect to the inverter output AC rated power taking into account the local daily distribution of solar radiation and ambient temperature. In addition, the proposed methodology specifies the appropriate number of PV modules in each string and the number of parallel strings connected to the input of the inverteraccording to its specifications and to PV cell temperature. Mathematically modeling of system parameters and components are presented and used in the simulation to investigate the different scenarios. The paper presents also a case study using simulation to find the optimal matching parameters of a PV array connected to an inverter with the specifications: 6 kW rated output power, an input mpp voltage range of 333-500 V, 6.2 kW maximum input DC power, and an output AC voltage of 230 Vrms. Considering the local climate conditions in West Bank, the simulation resulted a peak power of 7 kW for the PV array, which is greater than the inverter output power by the factor 1.16. In addition, the obtained PV array consists of two parallel strings each includes 12 PV modules connected in series while each PV module is rated at 290 W. The output voltage of the PV arrayvaries between 359 V to 564 Vat minimum and maximum temperature of 10 ˚C to 70 ˚C respectively. This PV array-inverter combination resulted by simulation an annual yield of 1600 kWh/kWp and an energy of 11197 kWh which corresponds to an energy gain of 1591 kWh/year more than using a PV array with a peak power of 6 kW as the inverter rated power.
- 8 April 2021
- Published by Center of Biomass and Renewable Energy Scientia Academy in International Journal of Renewable Energy Development
- Vol. 10 (4) , 687-697
Open AccessImprovement Approach for Matching PV-array and Inverter of Grid Connected PV Systems Verified by a Case Study
Correct matching between PV array and inverter improves the inverter efficiency, increases the annual produced energy, decreases the clipping losses of the inverter, and prevent to a large extent the inverter frequent shut downs during clear sunny days of high solar radiation and low ambient temperature. Therefore, this paper presents a new methodology for selecting the appropriate peak power of the PV array with respect to the inverter output AC rated power taking into account the local daily distribution of solar radiation and ambient temperature. In addition, the proposed methodology specifies the appropriate number of PV modules in each string and the number of parallel strings connected to the input of the inverteraccording to its specifications and to PV cell temperature. Mathematically modeling of system parameters and components are presented and used in the simulation to investigate the different scenarios. The paper presents also a case study using simulation to find the optimal matching parameters of a PV array connected to an inverter with the specifications: 6 kW rated output power, an input mpp voltage range of 333-500 V, 6.2 kW maximum input DC power, and an output AC voltage of 230 Vrms. Considering the local climate conditions in West Bank, the simulation resulted a peak power of 7 kW for the PV array, which is greater than the inverter output power by the factor 1.16. In addition, the obtained PV array consists of two parallel strings each includes 12 PV modules connected in series while each PV module is rated at 290 W. The output voltage of the PV arrayvaries between 359 V to 564 Vat minimum and maximum temperature of 10 ˚C to 70 ˚C respectively. This PV array-inverter combination resulted by simulation an annual yield of 1600 kWh/kWp and an energy of 11197 kWh which corresponds to an energy gain of 1591 kWh/year more than using a PV array with a peak power of 6 kW as the inverter rated power.
- Open Access
- 17 February 2019
- Published by Wiley in International Journal of Photoenergy
- Vol. 2019, 1-9
Design and Simulation of a PV System Operating in Grid-Connected and Stand-Alone Modes for Areas of Daily Grid Blackouts
The electricity in Gaza, Palestine, is limited and scheduled for 4-10 hours per day due to political reasons. This status represents a real problem for different sectors. This paper presents an effective solution especially for the energy supply problem in the residential sector by using an unconventional PV system which operates in stand-alone and grid-connected modes. The system includes a storage battery block with a proper capacity to secure for continuous power supply of a residential house with a daily energy load of 10 kWh. It was found that an unconventional PV system of 3.2 kWp and a storage battery block of 19.2 kWh will be able to cover the total daily energy demands of the house including the outlined electricity cutoff hours. The design of this system and specifics of its components are presented in this paper. The system was simulated by Matlab software, where the daily load curve, grid cutoff hours, and the monthly solar radiation are considered. The obtained simulation results show that the produced PV energy exceeds the load demands during nine months of the year, and thereby, a high battery state of charge (SOC) in the range of 73-84% is achieved. During the three months of the lowest solar radiation (Dec.-Feb.), the produced PV energy is equal to the load demand while the battery state of charge varies in the range of 40-49% which verifies the appropriateness of the proposed PV system. The daily energy yield of the PV system varies between 2.6 and 5.4 kWh/kWp in January and July, respectively, which corresponds to a performance ratio of 90% and 66.25%, respectively.
- 17 February 2019
- Published by Wiley in International Journal of Photoenergy
- Vol. 2019, 1-9
Open AccessDesign and Simulation of a PV System Operating in Grid-Connected and Stand-Alone Modes for Areas of Daily Grid Blackouts
The electricity in Gaza, Palestine, is limited and scheduled for 4-10 hours per day due to political reasons. This status represents a real problem for different sectors. This paper presents an effective solution especially for the energy supply problem in the residential sector by using an unconventional PV system which operates in stand-alone and grid-connected modes. The system includes a storage battery block with a proper capacity to secure for continuous power supply of a residential house with a daily energy load of 10 kWh. It was found that an unconventional PV system of 3.2 kWp and a storage battery block of 19.2 kWh will be able to cover the total daily energy demands of the house including the outlined electricity cutoff hours. The design of this system and specifics of its components are presented in this paper. The system was simulated by Matlab software, where the daily load curve, grid cutoff hours, and the monthly solar radiation are considered. The obtained simulation results show that the produced PV energy exceeds the load demands during nine months of the year, and thereby, a high battery state of charge (SOC) in the range of 73-84% is achieved. During the three months of the lowest solar radiation (Dec.-Feb.), the produced PV energy is equal to the load demand while the battery state of charge varies in the range of 40-49% which verifies the appropriateness of the proposed PV system. The daily energy yield of the PV system varies between 2.6 and 5.4 kWh/kWp in January and July, respectively, which corresponds to a performance ratio of 90% and 66.25%, respectively.
- 1 February 2018
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 82, 2490-2497
Grid connected PV- home systems in Palestine: A review on technical performance, effects and economic feasibility
- 1 February 2018
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 82, 2490-2497
Grid connected PV- home systems in Palestine: A review on technical performance, effects and economic feasibility
- 17 July 2017
- Published by Wiley in Materialwissenschaft und Werkstofftechnik
- Vol. 48 (7) , 731-736
Abrasion resistance of blended polymers filled with metallic powders
- 17 July 2017
- Published by Wiley in Materialwissenschaft und Werkstofftechnik
- Vol. 48 (7) , 731-736
Abrasion resistance of blended polymers filled with metallic powders
- 6 March 2015
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 37 (7) , 687-695
Optimal Sizing of Hybrid PV/Wind Systems for Malaysia Using Loss of Load Probability
Optimization of hybrid photovoltaic/wind system for Kuala Terengganu, Malaysia has been implemented by considering optimal sizing of photovoltaic array, wind turbine, and battery. The optimization technique is done based on loss of load probability and system cost. Simulation models of hybrid photovoltaic/wind system are developed by using daily solar energy and wind speed records and considering many configurations of photovoltaic array, wind turbine, and storage battery. The optimization performed in this research aims to select the optimal capacities of photovoltaic array and wind turbine, which give minimum system cost.
- 6 March 2015
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 37 (7) , 687-695
Optimal Sizing of Hybrid PV/Wind Systems for Malaysia Using Loss of Load Probability
Optimization of hybrid photovoltaic/wind system for Kuala Terengganu, Malaysia has been implemented by considering optimal sizing of photovoltaic array, wind turbine, and battery. The optimization technique is done based on loss of load probability and system cost. Simulation models of hybrid photovoltaic/wind system are developed by using daily solar energy and wind speed records and considering many configurations of photovoltaic array, wind turbine, and storage battery. The optimization performed in this research aims to select the optimal capacities of photovoltaic array and wind turbine, which give minimum system cost.
- 25 February 2015
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 37 (6) , 606-613
Optimization of the Tilt Angle of Solar Panels for Malaysia
This article presents a method for optimizing the tilt angle of photovoltaic module/array installed in the five sites in Malaysia. The optimization method is based on the Liu and Jordan model for solar energy incident on a tilt surface considering monthly and seasonal tilt angles. The optimization results showed that a seasonal optimum tilt angle change is recommended for the peninsular Malaysia, while a monthly optimum tilt angle change is recommended for east Malaysia comprising the states of Sabah and Sarawak. By applying the monthly optimum tilt angle, the collected yields by the PV module/array in Kuala Lumpur, Johor Bharu, Ipoh, Kuching, and Alor Setar increased by 5.03, 5.02, 5.65, 7.96, and 6.13%, respectively. On the other hand, applying the seasonal optimum tilt angle for the same regions increased the collected yields by 4.54, 4.58, 5.70, 4.11, and 5.85%, respectively.
- 25 February 2015
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 37 (6) , 606-613
Optimization of the Tilt Angle of Solar Panels for Malaysia
This article presents a method for optimizing the tilt angle of photovoltaic module/array installed in the five sites in Malaysia. The optimization method is based on the Liu and Jordan model for solar energy incident on a tilt surface considering monthly and seasonal tilt angles. The optimization results showed that a seasonal optimum tilt angle change is recommended for the peninsular Malaysia, while a monthly optimum tilt angle change is recommended for east Malaysia comprising the states of Sabah and Sarawak. By applying the monthly optimum tilt angle, the collected yields by the PV module/array in Kuala Lumpur, Johor Bharu, Ipoh, Kuching, and Alor Setar increased by 5.03, 5.02, 5.65, 7.96, and 6.13%, respectively. On the other hand, applying the seasonal optimum tilt angle for the same regions increased the collected yields by 4.54, 4.58, 5.70, 4.11, and 5.85%, respectively.
- 1 January 2013
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 10 (1) , 41-52
Optimal Sizing of the Energy Sources in Hybrid PV/Diesel Systems: A Case Study for Malaysia
This article presents optimization of hybrid photovoltaic (PV)/diesel systems for five regions in Malaysia. The PV array, storage battery, and diesel generator capacities are the variables to be optimized, considering very low loss of load probability. In the proposed optimization method, a hybrid PV/diesel system model is developed using a long-term solar energy series and a defined load demand. The objective of the optimization problem is to minimize the system cost and to determine the optimal sizing of PV array, storage battery, and diesel generator in terms of its unit cost. As a result, for an optimal sizing of hybrid PV/diesel generator for Malaysia, the PV array capacity must be 1.12 times the load demand, the diesel generator capacity must be 0.3 times the load demand, and the optimum storage battery size must be 0.29 times the load demand. The proposed PV/diesel system is validated by comparing it with a benchmark system. This system supplies the load demand of a school located in the state of Sabah. The load demand of this school is 1012 kWh/day during working days and 812 kWh/day during weekends and holidays. This load is supplied by a 150 kW diesel generator and a 35 kWp PV array without backup batteries. The comparison is based on the lifetime cost of the system that leads to the kWh unit price.
- 1 January 2013
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 10 (1) , 41-52
Optimal Sizing of the Energy Sources in Hybrid PV/Diesel Systems: A Case Study for Malaysia
This article presents optimization of hybrid photovoltaic (PV)/diesel systems for five regions in Malaysia. The PV array, storage battery, and diesel generator capacities are the variables to be optimized, considering very low loss of load probability. In the proposed optimization method, a hybrid PV/diesel system model is developed using a long-term solar energy series and a defined load demand. The objective of the optimization problem is to minimize the system cost and to determine the optimal sizing of PV array, storage battery, and diesel generator in terms of its unit cost. As a result, for an optimal sizing of hybrid PV/diesel generator for Malaysia, the PV array capacity must be 1.12 times the load demand, the diesel generator capacity must be 0.3 times the load demand, and the optimum storage battery size must be 0.29 times the load demand. The proposed PV/diesel system is validated by comparing it with a benchmark system. This system supplies the load demand of a school located in the state of Sabah. The load demand of this school is 1012 kWh/day during working days and 812 kWh/day during weekends and holidays. This load is supplied by a 150 kW diesel generator and a 35 kWp PV array without backup batteries. The comparison is based on the lifetime cost of the system that leads to the kWh unit price.
- Open Access
- 24 June 2012
- Published by Hindawi Limited in International Journal of Photoenergy
- Vol. 2012, 1-7
Assessment of Artificial Neural Networks for Hourly Solar Radiation Prediction
This paper presents an assessment for the artificial neural network (ANN) based approach for hourly solar radiation prediction. The Four ANNs topologies were used including a generalized (GRNN), a feed-forward backpropagation (FFNN), a cascade-forward backpropagation (CFNN), and an Elman backpropagation (ELMNN). The three statistical values used to evaluate the efficacy of the neural networks were mean absolute percentage error (MAPE), mean bias error (MBE) and root mean square error (RMSE). Prediction results show that the GRNN exceeds the other proposed methods. The average values of the MAPE, MBE and RMSE using GRNN were 4.9%, 0.29% and 5.75%, respectively. FFNN and CFNN efficacies were acceptable in general, but their predictive value was degraded in poor solar radiation conditions. The average values of the MAPE, MBE and RMSE using the FFNN were 23%, −.09% and 21.9%, respectively, while the average values of the MAPE, MBE and RMSE using CFNN were 22.5%, −19.15% and 21.9%, respectively. ELMNN fared the worst among the proposed methods in predicting hourly solar radiation with average MABE, MBE and RMSE values of 34.5%, −11.1% and 34.35%. The use of the GRNN to predict solar radiation in all climate conditions yielded results that were highly accurate and efficient.
- 24 June 2012
- Published by Hindawi Limited in International Journal of Photoenergy
- Vol. 2012, 1-7
Open AccessAssessment of Artificial Neural Networks for Hourly Solar Radiation Prediction
This paper presents an assessment for the artificial neural network (ANN) based approach for hourly solar radiation prediction. The Four ANNs topologies were used including a generalized (GRNN), a feed-forward backpropagation (FFNN), a cascade-forward backpropagation (CFNN), and an Elman backpropagation (ELMNN). The three statistical values used to evaluate the efficacy of the neural networks were mean absolute percentage error (MAPE), mean bias error (MBE) and root mean square error (RMSE). Prediction results show that the GRNN exceeds the other proposed methods. The average values of the MAPE, MBE and RMSE using GRNN were 4.9%, 0.29% and 5.75%, respectively. FFNN and CFNN efficacies were acceptable in general, but their predictive value was degraded in poor solar radiation conditions. The average values of the MAPE, MBE and RMSE using the FFNN were 23%, −.09% and 21.9%, respectively, while the average values of the MAPE, MBE and RMSE using CFNN were 22.5%, −19.15% and 21.9%, respectively. ELMNN fared the worst among the proposed methods in predicting hourly solar radiation with average MABE, MBE and RMSE values of 34.5%, −11.1% and 34.35%. The use of the GRNN to predict solar radiation in all climate conditions yielded results that were highly accurate and efficient.
- Open Access
- 3 June 2012
- Published by Hindawi Limited in International Journal of Photoenergy
- Vol. 2012, 1-16
Solar Energy Prediction for Malaysia Using Artificial Neural Networks
This paper presents a solar energy prediction method using artificial neural networks (ANNs). An ANN predicts a clearness index that is used to calculate global and diffuse solar irradiations. The ANN model is based on the feed forward multilayer perception model with four inputs and one output. The inputs are latitude, longitude, day number, and sunshine ratio; the output is the clearness index. Data from 28 weather stations were used in this research, and 23 stations were used to train the network, while 5 stations were used to test the network. In addition, the measured solar irradiations from the sites were used to derive an equation to calculate the diffused solar irradiation, a function of the global solar irradiation and the clearness index. The proposed equation has reduced the mean absolute percentage error (MAPE) in estimating the diffused solar irradiation compared with the conventional equation. Based on the results, the average MAPE, mean bias error and root mean square error for the predicted global solar irradiation are 5.92%, 1.46%, and 7.96%. The MAPE in estimating the diffused solar irradiation is 9.8%. A comparison with previous work was done, and the proposed approach was found to be more efficient and accurate than previous methods.
- 3 June 2012
- Published by Hindawi Limited in International Journal of Photoenergy
- Vol. 2012, 1-16
Open AccessSolar Energy Prediction for Malaysia Using Artificial Neural Networks
This paper presents a solar energy prediction method using artificial neural networks (ANNs). An ANN predicts a clearness index that is used to calculate global and diffuse solar irradiations. The ANN model is based on the feed forward multilayer perception model with four inputs and one output. The inputs are latitude, longitude, day number, and sunshine ratio; the output is the clearness index. Data from 28 weather stations were used in this research, and 23 stations were used to train the network, while 5 stations were used to test the network. In addition, the measured solar irradiations from the sites were used to derive an equation to calculate the diffused solar irradiation, a function of the global solar irradiation and the clearness index. The proposed equation has reduced the mean absolute percentage error (MAPE) in estimating the diffused solar irradiation compared with the conventional equation. Based on the results, the average MAPE, mean bias error and root mean square error for the predicted global solar irradiation are 5.92%, 1.46%, and 7.96%. The MAPE in estimating the diffused solar irradiation is 9.8%. A comparison with previous work was done, and the proposed approach was found to be more efficient and accurate than previous methods.
- Open Access
- 27 February 2012
- Published by Hindawi Limited in International Journal of Photoenergy
- Vol. 2012, 1-7
A New Approach for Optimal Sizing of Standalone Photovoltaic Systems
This paper presents a new method for determining the optimal sizing of standalone photovoltaic (PV) system in terms of optimal sizing of PV array and battery storage. A standalone PV system energy flow is first analysed, and the MATLAB fitting tool is used to fit the resultant sizing curves in order to derive general formulas for optimal sizing of PV array and battery. In deriving the formulas for optimal sizing of PV array and battery, the data considered are based on five sites in Malaysia, which are Kuala Lumpur, Johor Bharu, Ipoh, Kuching, and Alor Setar. Based on the results of the designed example for a PV system installed in Kuala Lumpur, the proposed method gives satisfactory optimal sizing results.
- 27 February 2012
- Published by Hindawi Limited in International Journal of Photoenergy
- Vol. 2012, 1-7
Open AccessA New Approach for Optimal Sizing of Standalone Photovoltaic Systems
This paper presents a new method for determining the optimal sizing of standalone photovoltaic (PV) system in terms of optimal sizing of PV array and battery storage. A standalone PV system energy flow is first analysed, and the MATLAB fitting tool is used to fit the resultant sizing curves in order to derive general formulas for optimal sizing of PV array and battery. In deriving the formulas for optimal sizing of PV array and battery, the data considered are based on five sites in Malaysia, which are Kuala Lumpur, Johor Bharu, Ipoh, Kuching, and Alor Setar. Based on the results of the designed example for a PV system installed in Kuala Lumpur, the proposed method gives satisfactory optimal sizing results.